Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fracture control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Positive Surgical Margins in Soft Tissue Sarcoma Treated With Preoperative Radiation: Is a Postoperative Boost Necessary?

Purpose: For patients with an extremity soft tissue sarcoma (STS) treated with preoperative radiotherapy and surgically excised with positive margins, we retrospectively reviewed whether a postoperative radiation boost reduced the risk of local recurrence (LR). Methods and Materials: A total of 216 patients with positive margins after resection of an extremity STS treated between 1986 and 2003 were identified from our institution's prospectively collected database. Patient demographics, radiation therapy parameters including timing and dose, classification of positive margin status, reasons for not administering a postoperative boost, and oncologic outcome were collected and evaluated. Results: Of the 216 patients with a positive surgical margin, 52 patients were treated with preoperative radiation therapy alone (50 Gy), whereas 41 received preoperative radiation therapy plus a postoperative boost (80% received 16 Gy postoperatively for a total of 66 Gy). There was no difference in baseline tumor characteristics between the two groups. Six of 52 patients in the group receiving preoperative radiation alone developed a LR compared with 9 of 41 in the boost group. Five-year estimated LR-free survivals were 90.4% and 73.8%, respectively (p = 0.13). Conclusions: We found that including the postoperative radiation boost after preoperative radiation and a margin-positive excision did not provide an advantage in preventing LR for patients treated with external beam radiotherapy. Given that higher radiation doses placed patients at greater risk for late complications such as fracture, fibrosis, edema, and joint stiffness, judicious avoidance of the postoperative boost while maintaining an equivalent rate of local control can reduce the risk of these difficult-to-treat morbidities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Performance of III-V Solar Cells Grown on Spalled Germanium with Ex Situ Substrate Planarization

Controlled spalling allows removal of devices and provides an opportunity for cost reduction through substrate reuse. However, the fracture-based process can leave behind morphological surface features, notably river lines, that can disrupt epitaxial growth and degrade device performance. We investigate the viability of various wet etch chemistries to planarize river lines to ensure high-quality device growth and performance without mechanical repolishing, and so maintain a route towards cost-effective reuse. Etching in a HF: HNO 3 :CH 3 COOH solution effectively planarizes river lines and produces a surface that yields devices with equivalent performance to those grown on epi-ready Ge wafer surfaces. Further studies will focus on optimizing etch composition, temperature, and time to minimize material removal while maintaining a suitable surface for high-quality epitaxy.

germanium↗

Impaired osteoblast differentiation in Annexin A2- and -A5-deficient cells

Annexins are a class of calcium-binding proteins with diverse functions in the regulation of lipid rafts inflammation,fibrinolysis, transcriptional programming and ion transport. Within bone, they are well-characterized as components of mineralizing matrix vesicles, although little else is known as to their function during osteogenesis. We generated annexin A2 (AnxA2)- or annexin A5 (AnxA5)-knockdown pre-osteoblasts, and asked whether proliferation or osteogenic differentiation was altered in knockdown cells, compared to vector controls. We report that DNA content, a marker of proliferation, was significantly reduced in both AnxA2 and AnxA5 knockdown cells. Alkaline phosphatase expression and staining activity were also suppressed in AnxA2- or AnxA5-knockdown after 14 days of culture. The pattern of osteogenic gene expression was altered in knockdown cells, with Col1a1 expressed more rapidly in knock-down cells, compared to controls. In contrast, Runx2, Ibsp, and Bglap all revealed decreased expression after 14 days of culture. Using a murine fracture model, we demonstrate that AnxA2 and AnxA5 are rapidly expressed within the fracture callus. These data demonstrate that AnxA2 and AnxA5 can influence bone formation via regulation of osteoprogenitor proliferation and differentiation in addition to their well-studied function in matrix vesicles.

annexin, bone, gene expression↗

Risk Assessment for Titanium Pressure Vessels Operating Inside the ARES I's Liquid Hydrogen Tank Environment

Titanium alloy (Ti-6-4) is currently being proposed for the manufacturing of pressure vessels (PV) for storage of compressed helium gas, which are mounted inside the ARES I's liquid hydrogen (LH2) tank. At cryogenic temperature, titanium alloys usually have the highest strength-to-weight ratio property and have been considered as the metallic materials of choice for lightweight PV operating in LH2 environment. Titanium PV s are also considered as heritage hardware because they have been used by NASA for the Saturn IV-B rocket s LH2 tank in the mid 1960 s. However, hydrogen embrittlement is possible if Ti-6-4 alloy is exposed to gaseous hydrogen at certain pressure and temperature during the LH2 tank filling and draining operations on the launch pad, and during the J2X engine burn period for the ARES I s upper stage. Additionally, the fracture toughness and ductility properties of Ti-6-4 are significantly decreased at cryogenic temperature. These factors do not necessary preclude the use of titanium PV in hydrogen or at cryogenic applications; however, their synergistic effects and the material damage tolerance must be accounted for in the mission life assessment for PV s, which are considered as fracture critical hardware. In this paper, an overview of the risk assessment for Ti-6-4 alloy, strategy to control hydrogen embrittlement and brief metallic material trade study for PV operating in LH2 tank will be presented.

Lee, Jonathan A.↗

LANL Activities: FY12-Q2 National Risk Assessment Partnership (NRAP): Industrial Carbon Capture Program (Quarterly Report)

This report summarizes progress of LANL activities related to the tasks performed under the LANL FWP FE102-002-FY10, National Risk Assessment Partnership (NRAP): Industrial Carbon Capture Program. This FWP is funded through the American Recovery and Reinvestment Act (ARRA). Overall, the NRAP activities are focused on understanding and evaluating risks associated with large-scale injection and long-term storage of CO 2 in deep geological formations. One of the primary risks during large-scale injection is due to changes in geomechanical stresses to the storage reservoir, to the caprock/seals and to the wellbores. These changes may have the potential to cause CO 2 and brine leakage and geochemical impacts to the groundwater systems. While the importance of these stresses is well recognized, there have been relatively few quantitative studies (laboratory, field or theoretical) of geomechanical processes in sequestration systems. In addition, there are no integrated studies that allow evaluation of risks to groundwater quality in the context of CO 2 injection-induced stresses. The work performed under this project is focused on better understanding these effects. LANL approach will develop laboratory and computational tools to understand the impact of CO 2 -induced mechanical stress by creating a geomechanical test bed using inputs from laboratory experiments, field data, and conceptual approaches. The Geomechanical Test Bed will be used for conducting sensitivity and scenario analyses of the impacts of CO 2 injection. The specific types of questions will relate to fault stimulation and fracture inducing stress on caprock, changes in wellbore leakage due to evolution of stress in the reservoir and caprock, and the potential for induced seismicity. In addition, the Geomechanical Test Bed will be used to investigate the coupling of stress-induced leakage pathways with impacts on groundwater quality. LANL activities are performed under two tasks: (1) develop laboratory and computational tools to understand CO 2 -induced mechanical impacts and (2) use natural analog sites to determine potential groundwater impacts. We are using the Springerville-St. John Dome as a field site for collecting field data on CO 2 migration through faults and groundwater impacts as well as developing and validating computational models. During the FY12 second quarter we have been working with New England Research Company to construct a tri-axial core-holder. We have built fluid control system for the coreflood system that can be ported to perform in-situ imaging of core. We have performed numerical simulations for groundwater impacts of CO 2 and brine leakage using the reservoir model for Springerville-St John's Dome site. We have analyzed groundwater samples collected from Springerville site for major ion chemistry and isotopic composition. We are currently analyzing subsurface core and chip samples acquired for mineralogical composition.

25 ENERGY STORAGE↗

Unified cohesive zone model (UCZM) for fracturing and fragmenting solids

Here, a Unified Cohesive Zone Model (UCZM), which inherits most of the advantages while overcoming the shortcomings of existing Cohesive Zone Models (CZMs), is proposed. Similar to the traditional extrinsic CZM approach, UCZM dynamically inserts the cohesive elements into the system based on local material states (e.g., stress, strain). However, the transition from continua to discontinua is smoothly achieved, thereby eliminating the “time-discontinuous” issue seen in the extrinsic CZM. Moreover, within the novel UCZM framework, the point of transition from continua to discontinua is controllable through the introduction of crack initialization criteria. As a result, the UCZM allows any material models (e.g., elastic, plastic, damage models) for continuum solids and for discrete fracture behavior to work together. In essence, both an enhanced extrinsic cohesive zone model and an intrinsic cohesive zone model can be represented by the proposed unified model. The proposed UCZM has been verified through different numerical examples. The work demonstrates that the UCZM is a highly effective approach for modeling fracture and fragmentation processes in solids.

42 ENGINEERING↗

Challenges and opportunities for fractured rock imaging using 3D cross-borehole electrical resistivity

There is an increasing need to characterize discrete fractures away from boreholes to better define fracture distributions and monitor solute transport. We performed a 3D evaluation of static and time-lapse cross-borehole electrical resistivity tomography (ERT) data sets from a limestone quarry in which flow and transport are controlled by a bedding-plane feature. Ten boreholes were discretized using an unstructured tetrahedral mesh, and 2D panel measurements were inverted for a 3D distribution of conductivity. We evaluated the benefits of 3D versus 2.5D inversion of ERT data in fractured rock while including the use of borehole regularization disconnects (BRDs) and borehole conductivity constraints. High-conductivity halos (inversion artifacts) surrounding boreholes were removed in static images when BRDs and borehole conductivity constraints were implemented. Furthermore, applying these constraints focused transient changes in conductivity resulting from solute transport on the bedding plane, providing a more physically reasonable model for conductivity changes associated with solute transport at this fractured rock site. Assuming bedding-plane continuity between fractures identified in borehole televiewer data, we discretized a planar region between six boreholes and applied a fracture regularization disconnect (FRD). Although the FRD appropriately focused conductivity changes on the bedding plane, the conductivity distribution within the discretized fracture was nonunique and dependent on the starting homogeneous model conductivity. Synthetic studies performed to better explain field observations showed that inaccurate electrode locations in boreholes resulted in low-conductivity halos surrounding borehole locations. These synthetic studies also showed that the recovery of the true conductivity within an FRD depended on the conductivity contrast between the host rock and fractures. Our findings revealed that the potential exists to improve imaging of fractured rock through 3D inversion and accurate modeling of boreholes. However, deregularization of localized features can result in significant electrical conductivity artifacts, especially when representing features with a high degree of spatial uncertainty.

resistivity, fractured rock, inversion, imaging, g↗

Poromechanical cohesive interface element with combined Mode I-II cohesive zone elastoplasticity for simulating fracture in fluid-saturated porous media

A combined Mode I-II cohesive zone (CZ) elasto-plastic constitutive model, and a two-dimensional (2D) cohesive interface element (CIE) are formulated and implemented at small strain within an ABAQUS User Element (UEL) for simulating 2D crack nucleation and propagation in fluid-saturated porous media. Here, the CZ model mitigates problems of convergence for the global Newton-Raphson solver within ABAQUS, which when combined with a viscous stabilization procedure allows for simulation of post-peak response under load control for coupled poromechanical finite element analysis, such as concrete gravity dam stability analysis. Verification examples are presented, along with a more complex ambient limestone-concrete wedge fracture experiment, water-pressurized concrete wedge experiment, and concrete gravity dam stability analyses. A calibration procedure for estimating the CZ parameters is demonstrated with the limestone-concrete wedge fracture process. For the water-pressurized concrete wedge fracture experiment it is shown that the inherent time-dependence of the poromechanical CIE analysis provides a good match with experimental force versus displacement results at various crack mouth opening rates, yet misses the pore water pressure evolution ahead of the crack tip propagation. This is likely a result of the concrete being partially-saturated in the experiment, whereas the finite element analysis assumes fully water saturated concrete. For the concrete gravity dam analysis, it is shown that base crack opening and associated water uplift pressure leads to a reduced Factor of Safety, which is confirmed by separate analytical calculations.

97 MATHEMATICS AND COMPUTING↗

Fracture Networks Imaging in CO2 Injection Zones in IBDP Site: An Unsupervised Machine Learning Application with Multiple Datasets

Poster presented at the 17th International Conference on Greenhouse Gas Control Technologies GHGT-17 held in Calgary, Canada, October 20-24, 2024. This poster highlights the integration of unsupervised machine learning (ML) techniques as a transformative tool for advancing understanding of CO2 injection into reservoirs that could potentially contribute to optimizing injection strategies and reservoir management, ultimately bolstering the efficacy and sustainability of CO2 storage.

Kumar, Abhash↗

Some fundamental aspects of the fatigue and fracture response of composite materials

A simple analytical model, based on the concept that the constraining plies surrounding cracks through the thickness of a given ply or plies control the spacing of those cracks by controlling the surrounding stress state, appears to agree well with experimental data. Such a model can be used to evaluate critically various constraint situations including the prediction of the ability of a given constraint layer to arrest flaw development. The analytical model, which uses an equilibrium element approach in the present case, is sensitive to lamina and laminate elastic properties, flaw size, stacking sequence, and an interlaminar stress transfer distance which is estimated from experimental observations. The analysis is easily extended to study flaw growth and plastic region formation.

Reifsnider, K. L.↗

An arc-length method for controlled cohesive crack propagation using high-order XFEM and Irwin’s crack closure integral

Numerical modeling of cohesive crack growth in quasi-brittle materials is challenging, primarily due to the combination of (i) nonlinearity associated with the fracture process zone (FPZ), (ii) arbitrary directions to which a crack may propagate, and (iii) snap-back or snap-through instabilities encountered in the response of the structure. To address these challenges, here we propose a novel arc-length method that can follow the equilibrium path of cohesive crack propagation. The proposed approach is based on the extended finite element method (XFEM) with scalar high-order enrichment functions and Irwin’s crack closure integral, which allows for direct control of the applied loads necessary to propagate cohesive cracks. This is achieved by augmenting a constraint equation written in terms of stress intensity factors (SIFs), and expressed explicitly in terms of the enriched degrees of freedom, which is an attractive feature achieved with Irwin’s integral, since SIFs can be written in closed-form. Note that singular enrichments are active in an unstable crack propagation state and automatically vanish in stable crack configurations. Furthermore, to propagate cracks in arbitrary directions, we employ a maximum circumferential stress criterion implemented by (i) direct usage of the SIFs, and by (ii) a new stress-based nonlocal implementation of this principle. Various benchmark problems including pure mode I and mixed-mode fracture are solved to demonstrate the predictive capability of the present framework for cohesive crack modeling.

42 ENGINEERING↗

The EGS Collab Project – Stimulations at Two Depths

The EGS Collab project, supported by the US Department of Energy, is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory to address challenges in implementing enhanced geothermal systems (EGS). Data and observations from the field tests are compared to simulations to understand processes and build confidence in numerical modeling of the processes. We have completed Experiment 1 (of 3), which examined hydraulic fracturing in a well-characterized underground fractured phyllite test bed at a depth of approximately 1.5 km at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. Testbed characterization included fracture mapping, borehole acoustic and optical televiewers, full waveform sonic, conductivity, resistivity, temperature, campaign p- and s-wave investigations and electrical resistance tomography. Borehole geophysical techniques including passive seismic, continuous active source seismic monitoring, electrical resistance tomography, fiber-based distributed strain, distributed temperature, and distributed acoustic monitoring, were used to carefully monitor stimulation events and flow tests. More than a dozen stimulations and nearly one year of flow tests were performed. Quality data and detailed observations were collected and analyzed during stimulation and water flow tests using ambient temperature and chilled water. We achieved adaptive control of the tests using real-time monitoring and rapid dissemination of data and near-real-time simulation. More detailed numerical simulation was performed to answer key experimental design questions, forecast fracture propagation trajectories and extents, and analyze and evaluate results. Data are freely available from the Geothermal Data Repository. Experiment 2 examines the potential for hydraulic shearing in amphibolite at a depth of about 1.25 km at SURF. This site has a different set of stress and fracture conditions than Experiment 1. The Experiment 2 testbed consists of nine subhorizontal boreholes configured in two fans of two boreholes which surround the testbed and contain grouted-in electrical resistance tomography, seismic sensors, active seismic sources and distributed fiber sensors. A “five-spot” set of test wells that extends from a custom mined alcove includes an injection well and four production/monitoring wells. The testbed was characterized geophysically and hydrologically, and three stimulations have been performed using the Step-Rate Injection Method for Fracture In-Situ Properties (SIMFIP) tool to measure strains, and a new strain quantifying tool (downhole robotic strain analysis tool -DORSA) was deployed in a monitoring hole during stimulation. Real-time data were broadcast during stimulations to allow real-time response to arising issues.

EGS Collab, Enhanced Geothermal Systems, EGS, fiel↗

Long-Term Results Following Postoperative Radiotherapy for Soft Tissue Sarcomas of the Extremity

Purpose: To review long-term outcomes following postoperative radiotherapy (RT) for extremity soft tissue sarcoma (STS) and identify variables affecting the therapeutic ratio. Methods and Materials: Between 1970 and 2008, 173 patients with localized extremity STS were treated with postoperative radiation. No patients received prior irradiation. Sixteen percent of tumors had recurred after initial surgery alone; 89% of tumors were high grade. The median patient age was 57 years (range, 18-86 years). Sixty-one percent underwent >1 surgery before RT in an attempt to achieve wide negative margins. Final margin status was negative in 70% and marginal or microscopically positive in 30%. The median time between final surgery and start of RT was 40 days. The median RT dose was 65 Gy (range, 49-74 Gy). The median follow-up for all patients was 10.4 years and 13.2 years among survivors. Results: At 10 years, local control (LC), cause-specific survival (CSS), and overall survival (OS) rates were 87%, 80%, and 70%, respectively, with 89% of local failures occurring within 3 years after treatment. On multivariate analysis, age >55 years (82% vs 93%, P<.05) and recurrent presentation (67% vs 91%, P<.05) were associated with inferior 10-year LC. The LC according to final margin status was 90% for wide negative margins vs 79% for marginal/microscopically positive margins (P=.08). Age >55 years and local recurrence were associated with inferior CSS and OS on multivariate analysis. Twelve percent of patients experienced grade 3+ toxicity; 12 of these occurred in patients with tumors of the proximal lower extremity, with the most common toxicity of pathologic fracture occurring in 6.3%. Conclusions: This large single-institution series confirms that postoperative RT for STS of the extremities provides good long-term disease control with acceptable toxicity. Our experience supports recurrent presentation and older age as adverse prognostic factors for LC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operating and Maintaining the JWST Cleanroom attached to JSC's Chamber A during preparations for the OTIS Cryogenic Thermal Vacuum Test

In order to maintain cleanliness during preparations for JWST’s OTIS (Optical Telescope Element-Integrated Science Instrument Module) Cryogenic Thermal Vacuum Test, a cleanroom was built that attached directly to the 60-year-old Chamber A. The cleanroom and chamber were outfitted with independent environmental control systems each providing ISO Class 71 air cleanliness. To maintain balanced, positive pressure in both the cleanroom and chamber volumes, a special control protocol was developed and successfully implemented. Dual back-up environmental control units (one each for the chamber and cleanroom) were installed just outside the building to provide environmental control redundancy due to a single source chilled water supply and weather threats. In addition, lack of a dedicated cleanroom airlock facilitating clean ingress and egress made it necessary to perform additional cleaning and packaging, as well as augment the uncontrolled truck lock space with small clean tents for pre-cleaning. Special procedures were developed to allow ingress of extra-large support equipment required for load testing of the cleanroom crane, installation of optical equipment in Chamber A and accommodation of the OTIS shipping container. A thorough bake-out and cleaning of Chamber A was also necessary to reduce volatiles from the shroud’s black thermal paint and to reduce particle fallout. Acrylic adhesive fracture discovered during early cryo-testing represented a significant challenge that was successfully mitigated prior to OTIS testing. A dedicated team of Contamination Control (CC) Technicians was specifically trained to clean support equipment and screen materials entering the cleanroom and chamber to ensure cleanliness and vacuum compatibility.

Optics↗

Operating and Maintaining the JWST Cleanroom attached to JSC's Chamber A during preparations for the OTIS Cryogenic Thermal Vacuum Test

In order to maintain cleanliness during preparations for JWST’s OTIS (Optical Telescope Element-Integrated Science Instrument Module) Cryogenic Thermal Vacuum Test, a cleanroom was built that attached directly to the 60-year-old Chamber A. The cleanroom and chamber were outfitted with independent environmental control systems each providing ISO Class 71 air cleanliness. To maintain balanced, positive pressure in both the cleanroom and chamber volumes, a special control protocol was developed and successfully implemented. Dual back-up environmental control units (one each for the chamber and cleanroom) were installed just outside the building to provide environmental control redundancy due to a single source chilled water supply and weather threats. In addition, lack of a dedicated cleanroom airlock facilitating clean ingress and egress made it necessary to perform additional cleaning and packaging, as well as augment the uncontrolled truck lock space with small clean tents for pre-cleaning. Special procedures were developed to allow ingress of extra-large support equipment required for load testing of the cleanroom crane, installation of optical equipment in Chamber A and accommodation of the OTIS shipping container. A thorough bake-out and cleaning of Chamber A was also necessary to reduce volatiles from the shroud’s black thermal paint and to reduce particle fallout. Acrylic adhesive fracture discovered during early cryo-testing represented a significant challenge that was successfully mitigated prior to OTIS testing. A dedicated team of Contamination Control (CC) Technicians was specifically trained to clean support equipment and screen materials entering the cleanroom and chamber to ensure cleanliness and vacuum compatibility.

James Webb Space Telescope↗

Avoiding Fracture in a Conversion Battery Material through Reaction with Larger Ions

Conversion and alloying electrode materials offer high specific capacity for emerging sodium- and potassium-ion batteries, but the larger volume changes compared to reaction with lithium are thought to limit cyclability. The reaction mechanisms of many materials with Na + and K + are unknown, however, and this knowledge is key for engineering mechanically resilient materials. Here, in situ transmission electron microscopy is used to uncover the nanoscale transformations during the reaction of FeS 2 electrode materials with Li + , Na + , and K + . Surprisingly, despite larger volume changes during the conversion reaction with Na + and K + , the FeS 2 crystals only fracture during lithiation. Modeling of reaction-induced deformation shows that the shape of the two-phase reaction front influences stress evolution, and unique behavior during lithiation causes stress concentrations and fracture. The larger volume changes in Na- and K-ion battery materials may therefore be managed through understanding and control of reaction mechanisms, ultimately leading to better alkali-ion batteries.

25 ENERGY STORAGE↗

Low-Rate Cycling Regeneration Sustains NMC811–Graphite Battery Performance through Extreme Ultrafast Charging

Urban air mobility (UAM) systems, such as electric vertical takeoff and landing (eVTOL) aircraft, require batteries capable of extreme ultrafast charging to support high-frequency operations. Here, in this work, we evaluate the electrochemical stability of NMC811–graphite full cells using a complex mixed-modal protocol designed to simulate the aggressive turnaround demands of UAM missions. We demonstrate that incorporating a periodic low-rate (0.3C) “regeneration” cycle enables cells to maintain 96% capacity retention over 900 cycles, despite repeated exposure to ultrafast pulses. To validate the efficacy of this regeneration mechanism, we performed simplified control experiments comparing continuous 10C charging against a 10C–0.3C interleaved protocol. Advanced characterization reveals that while mechanical particle fracture is pervasive at these rates, the regeneration cycles decelerate the electrochemical degradation by resolving spatially heterogeneous Ni oxidation states and relaxing lithium-ion concentration gradients. These findings provide a vital mechanistic framework for battery operation, proving that restorative charging can effectively delay and mitigate failure in demanding UAM applications.

batteries↗

Stress and Strain Heterogeneity and Persistence in Uniaxially‐ and Triaxially‐Loaded Sandstone

Two critical questions in brittle rock mechanics are how rocks developed localized strains and to what extent internal stress heterogeneity controls this localization and subsequent macroscopic failure. Definitive answers have not yet been found, but would provide insight into rock fracture mechanics as relevant to hydrocarbon extraction and sequestration. Here, we use synchrotron X‐ray tomography (XRT) and 3D X‐ray diffraction (3DXRD) during uniaxial and triaxial tests on Nugget and Bentheimer sandstones to examine strain and stress localization prior to mechanical failure. 3DXRD was used to measure intra‐granular lattice strains which were used to compute elastic stress tensors of each grain. Digital volume correlation (DVC) was applied to XRT images to determine the strain field in the sample. Both samples featured marked spatial heterogeneity, localization, and temporal persistence of elevated stresses and strains during their mechanical deformation toward failure. Both samples featured a majority of grains with at least one principal stress component that was tensile, a signature of the influence of heterogeneity on stress transmission. Measurements further revealed that compressive stress orientations and statistics evolved in a similar manner to those of inter‐particle forces in loose granular materials, with triaxially‐compressed rock exhibiting enhanced grain stress heterogeneity compared to uniaxially‐compressed rock. Our results complement recent work by others who employed XRT and scanning 3DXRD to study triaxially‐compressed sandstone, but extend those results to uniaxial compression, sandstones of varied porosity, and grain stress measurements throughout the 3D full extent of the samples rather than in a single layer examined with scanning 3DXRD.

58 GEOSCIENCES↗