Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRAMING CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 {mu}m thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state-of-art flat panel detector (FPD).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time heterodyne speckle pattern interferometry using the correlation image sensor

A real-time method for heterodyne speckle pattern interferometry using the correlation image sensor (CIS) is proposed. The CIS demodulates the interference phase of heterodyned speckle wavefronts pixelwise at an ordinary video frame rate. The proposed method neither suffers loss of spatial resolution nor requires a high frame rate. Interferometers for out-of-plane and in-plane deformation are developed with a 200x200 pixel CIS camera. Experimental results confirm that the proposed method realizes real-time imaging of a rough-surfaced object under deformation. The average standard deviations of demodulated phase-difference images for the out-of-plane and in-plane interferometers are 0.33 and 0.13 rad, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technique increases storage capacity in camera tube target

Technique increases the signal current, where direct beam readout is used, in Secondary Electron Conduction /SEC/ camera tubes. Increasing the storage capacity and therefore the dynamic range of the SEC target permits satisfactory operation at reduced frame rates.

Boll, K. F.↗

Aeroelastic Deformation Measurements of Flap, Gap, and Overhang on a Semispan Model

Single-camera, single-view videogrammetry has been used to determine static aeroelastic deformation of a slotted flap configuration on a semispan model at the National Transonic Facility (NTF). Deformation was determined by comparing wind-off to wind-on spatial data from targets placed on the main element, shroud, and flap of the model. Digitized video images from a camera were recorded and processed to automatically determine target image plane locations that were then corrected for sensor, lens, and frame grabber spatial errors. The videogrammetric technique has been established at NASA facilities as the technique of choice when high-volume static aeroelastic data with minimum impact on data taking is required. The primary measurement at the NTF with this technique in the past has been the measurement of static aeroelastic wing twist on full span models. The first results using the videogrammetric technique for the measurement of component deformation during semispan testing at the NTF are presented.

Burner, A. W.↗

Dynamic Deformation Measurements of an Aeroelastic Semispan Model

The techniques used to acquire, reduce, and analyze dynamic deformation measurements of an aeroelastic semispan wind tunnel model are presented. Single-camera, single-view video photogrammetry (also referred to as videogrammetric model deformation, or VMD) was used to determine dynamic aeroelastic deformation of the semispan 'Models for Aeroelastic Validation Research Involving Computation' (MAVRIC) model in the Transonic Dynamics Tunnel at the NASA Langley Research Center. Dynamic deformation was determined from optical retroreflective tape targets at five semispan locations located on the wing from the root to the tip. Digitized video images from a charge coupled device (CCD) camera were recorded and processed to automatically determine target image plane locations that were then corrected for sensor, lens, and frame grabber spatial errors. Videogrammetric dynamic data were acquired at a 60-Hz rate for time records of up to 6 seconds during portions of this flutter/Limit Cycle Oscillation (LCO) test at Mach numbers from 0.3 to 0.96. Spectral analysis of the deformation data is used to identify dominant frequencies in the wing motion. The dynamic data will be used to separate aerodynamic and structural effects and to provide time history deflection data for Computational Aeroelasticity code evaluation and validation.

Graves, Sharon S.↗

Aeroelastic Deformation Measurements of Flap, Gap, and Overhang on a Semispan Model

Single-camera, single-view videogrammetry has been used for the first time to determine static aeroelastic deformation of a slotted flap configuration on a semispan model at the National Transonic Facility (NTF). Deformation was determined by comparing wind-off to wind-on spatial data from targets placed on the main element, shroud, and flap of the model. Digitized video images from a camera were recorded and processed to automatically determine target image plane locations that were then corrected for sensor, lens, and frame grabber spatial errors. The videogrammetric technique used for the measurements presented here has been established at NASA facilities as the technique of choice when high-volume static aeroelastic data with minimum impact on data taking is required. However, the primary measurement at the NTF with this technique in the past has been the measurement of the static aeroelastic wing twist of the main wing element on full span models rather than for the measurement of component deformation. Considerations for using the videogrammetric technique for semispan component deformation measurements as well as representative results are presented.

Burner, A. W.↗

Measurement of material recession and shock standoff in plasma windtunnel using neural nets

Arcjets are plasma wind tunnels used to test the performance of heatshield materials for spacecraft atmospheric entry. These facilities present an extremely harsh flow environment with heat fluxes up to 10^9 W/m^2 for up to 30 minutes. The plasma is low-temperature (~1 eV) but high pressure (> 10 kPa) creating high-enthalpy supersonic flows similar to atmospheric entry conditions. Typically, material samples are measured before and after a test to characterize the total recession. However, this does not capture time-dependent effects such as material expansion and non-linear recession. This work will present new analysis of arcjet test videos which measure both the time-dependent 2D recession of the material samples and the shock standoff distance. New results showing non-linear material erosion rates will be highlighted. The material and shock edges are extracted from the videos by training and applying a convolutional neural network. Due to the consistent camera settings, the machine learning model achieves high accuracy (~99%) on new data with only a small number of training frames (~80). The new results will be discussed in the context of temperature dependent plasma-surface interaction.

Magnus A Haw↗

Towards An Autonomous sUAS Operating in UTM TCL4+ and STEReO Fire Scenario

This study presents two sUAS payload point designs for enabling autonomous BVLOS flight in UTM TCL4+ urban environments and STEReO fire responses. The payload components for the first payload include an onboard computer and a 360 LIDAR. The second payload, which is a continuation of the first, adds a range finder altimeter, downward-facing monocular camera, forward-facing thermal and visible light dual camera, vehicle-to-vehicle radio modem, and Li-ion smart battery. The components are mounted on enclosed structural frames that were designed in-house. Placing the autonomy components onboard leverages the advantages of sUAS over manned aircraft such as low-cost, quick response time, and increased scalability. Autonomous capabilities include embedded processing, SLAM, object and fire detection, and V2V communication. Data processing is conducted onboard the aircraft to eliminate the dependency on a groundstation downlink. The first iteration of the payload is tested in both simulation and flight tests while the continuing iteration is in development.

Autonomous UAS↗

The CG-1D neutron imaging beamline at the Oak Ridge National Laboratory High Flux Isotope Reactor

The Oak Ridge National Laboratory Neutron Sciences Directorate has installed a neutron imaging beamline at the High Flux Isotope Reactor (HFIR) cold guide hall. CG-1D is one of the three instruments that make up the CG1 instrument suite. The beamline optics and detector have recently been upgraded to meet the needs of the neutron imaging community (better smoothing of guide system artifacts, higher flux or spatial resolution). These upgrades comprise a new diffuser/aperture system, two new detectors, a He-filled flight tube and silicon (Si) windows. Shielding inside the flight tube, beam scrapers and a beam stop ensure that biological dose is less than 50 Sv/hr outside of the radiation boundary. A set of diffusers and apertures (pinhole geometry) has been installed at the exit of the guide system to allow motorized L/D variation. Samples sit on a translation/rotation stage for alignment and tomography purposes. Detectors for the CG-1D beamline are (1) an ANDOR DW936 charge coupled device (CCD) camera with a field of view of approximately 7 cm x 7 cm and ~ 80 microns spatial resolution and 1 frame per second time resolution, (2) a new Micro-Channel Plate (MCP) detector with a 2.8 cm x 2.8 cm field of view and 55 microns spatial resolution, and 5 s timing capability. 6LiF/ZnS scintillators of thickness varying from 50 to 200 microns are being used at this facility. An overview of the beamline upgrade and preliminary data is presented here.

Santodonato, Louis J↗

Experimental Investigation of a Graphite-Composite Intertank Section for a Reusable Launch Vehicle

The use of graphite-composites as primary structure is essential for the development of a cost effective single-stage-to-orbit reusable launch vehicle (RLV). A full-scale segment of a graphite-composite intertank was designed and fabricated by an industry team and tested at NASA Langley Research Center as a part of the RLV technology development program. The intertank test component was approximately 3.0 m long by 6.7 m wide and included slightly less than a 90deg section of a cylindrical intertank. The test article was fabricated using graphite-bismaelimide composite material and consisted of a hat-stiffened skin with five ring frames. The stiffeners were secondarily bonded to the panel skin and the ring frames were mechanically attached. The test article was loaded to failure with a uniform compression load applied by 21 individually controlled hydraulic actuators. Resistance strain gages, linear variable differential transformers and video cameras were used to measure and record the test results. A linear f d t e element analysis of the test article and test fixture was performed. The test results verified the structural integrity cf the intertank test article up to the design limit load. However, the test article failed in general skin buckling between the ring frames at a load 1.08 times design limit load. This load was considerably lower than the expected failure load. The cause of premature failure is being investigated. Good correlation of the test and analysis results was obtained for loads up to the design limit load.

Sawyer, James Wayne↗

Astrometry of the omega Centauri Hubble Space Telescope Calibration Field

Astrometry, on the International Celestial Reference Frame (epoch J2000.0), is presented for the Walker (1994, PASP, 106, 828) stars in the omega Centauri (=NGC 5139=C 1323-1472) Hubble Space Telescope Wide Field/Planetary Camera (WF/PC) calibration field of Harris et al. (1993, AJ, 105, 1196). Harris et al. stars were first identified on a WFPC2 observation of the omega Cen HST calibration field. Relative astrometry of the Walker stars in this field was then obtained using Walker's CCD positions and astrometry derived using the STSDAS METRIC task on the positions of the Harris et al. stars on the WFPC2 observation. Finally, the relative astrometry, which was based on the HST Guide Star Catalog, is placed on the International Celestial Reference Frame with astrometry from the USNO-A2.0 catalog. An ASCII text version of the astrometric data of the Walker stars in the omega Cen HST calibration field is available electronically in the online version of the article.

Mighell, Kenneth J.↗

Camera Image Transformation and Registration for Safe Spacecraft Landing and Hazard Avoidance

Inherent geographical hazards of Martian terrain may impede a safe landing for science exploration spacecraft. Surface visualization software for hazard detection and avoidance may accordingly be applied in vehicles such as the Mars Exploration Rover (MER) to induce an autonomous and intelligent descent upon entering the planetary atmosphere. The focus of this project is to develop an image transformation algorithm for coordinate system matching between consecutive frames of terrain imagery taken throughout descent. The methodology involves integrating computer vision and graphics techniques, including affine transformation and projective geometry of an object, with the intrinsic parameters governing spacecraft dynamic motion and camera calibration.

Jones, Brandon M.↗

An experimental study on the motion, deformation and electrical charging of water drops falling in oil in the presence of high voltage D.C. electric field

The motion, deformation and electrical charging of conducting water drops falling in an insulating liquid subjected to various electric fields strength were studied experimentally. The drop motion was recorded contentiously by high speed camera and their responses to deformation under the influence of electric field were digitally extracted by image processing of the sequential frames. Two parameters were defined for describing the deviation and deformation of the drops under the electric forces. Outcomes depicted that the deviation of the drops from the vertical line would be increased by adding to the applied electrical potential as well as reduction of drop size. Moreover, regarding to deformation diagram, the results revealed a dissimilar deformation manner between large and small drops, which can be helpful in describing the drop-drop electro coalescence phenomena and in design of electrically driven droplet-based systems. (author)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First measurements of D{sub α} spectrum produced by anisotropic fast ions in the gas dynamic trap

Angled injection of eight deuterium beams in gas dynamic trap (GDT) plasmas builds up the population of fast ions with the distribution function, which conserves a high degree of initial anisotropy in space, energy, and pitch angle. Unlike the Maxwellian distribution case, the fast ion plasma component in GDT cannot be exhaustively characterized by the temperature and density. The instrumentation complex to study of fast ions is comprised of motional Stark effect diagnostic, analyzers of charge exchange atoms, and others. The set of numerical codes using for equilibrium modeling is also an important tool of analysis. In the recent campaign of summer 2014, we recorded first signals from the new fast ion D-alpha diagnostic on GDT. This paper presents the diagnostic description and results of pilot measurements. The diagnostic has four lines of sight, distributed across the radius of an axially symmetric plasma column in GDT. In the present setup, a line-integrated optical signal is measured in each channel. In the transverse direction, the spatial resolution is 18 mm. Collected light comes to the grating spectrometer with the low-noise detector based on a charge-coupled device matrix. In the regime of four spectra stacked vertically on the sensor, the effective spectral resolution of measurements is approximately 0.015 nm. Exposure timing is provided by the fast optical ferroelectric crystal shutter, allowing frames of duration down to 70 μs. This number represents the time resolution of measurements. A large dynamic range of the camera permits for a measurement of relatively small light signals produced by fast ions on top of the bright background emission from the bulk plasma. The fast ion emission has a non-Gaussian spectrum featuring the characteristic width of approximately 4 nm, which can be separated from relatively narrow Gaussian lines of D-alpha and H-alpha coming from the plasma periphery, and diagnostic beam emission. The signal to noise ratio varies from approximately ten for the central channel to approximately five for the outermost channel. We used the special set of Monte Carlo codes to fit the measured spectra. The shape of model fit shows a good agreement with the experimental fast ion D-alpha spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AKARI NEAR- AND MID-INFRARED SPECTROSCOPY OF APM 08279+5255 AT z = 3.91

We present rest-frame optical/near-infrared spectra of the gravitationally lensed quasar APM 08279+5255 at z = 3.91 that has been taken using the Infrared Camera (IRC) onboard the AKARI infrared satellite. The observed continuum consists of two components; a power-law component dominating optical wavelengths which is the direct light from the central source and thermal emission dominating near-infrared wavelengths which is attributed to the emission from hot dust in the circumnuclear region. The thermal emission well represents optically thick emission by hot dust at T {approx} 1300 K with {tau}{sub 2{mu}}{sub m} > 2 and apparent mass, M {sub hot} > 10 M {sub sun}. Thus, our observations directly detected the optically thick region of hot dust in APM 08279+5255. H I recombination lines of H{alpha} (0.656 {mu}m), Pa{alpha} (1.875 {mu}m), and Pa{beta} (1.282 {mu}m) are clearly detected at 3.2, 6.3, and 9.3 {mu}m. Simulations with the photoionization models suggest that APM 08279+5255 has broad-line region (BLR) clouds characterized by log n {sub H} {approx} 12-14 for the gas density, log U {approx} -2 to -6 for the ionization parameter, and E(B - V) {approx} 0.3-0.6 for the BLR. Thus, optically thick emission of hot dust supports an idea on nonspherical distribution of dust near the central source, consistent with the active galactic nuclei model with the dust torus. The temperature of hot dust and flux ratios of these H I lines are similar to those observed in low-redshift quasars. There are significant time variations in the H I lines, which are probably caused by variations in the brightness of the central source.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of Cosmic Gamma Ray Bursts in the Experiments Onboard Lomonosov and Vernov Satellites

The study of cosmic gamma ray bursts (GRBs) is one of the main goals of the Lomonosov space mission. The main advantage of this mission is simultaneous multiwavelength observations of GRBs covering the optical, X-ray and gamma-ray ranges. The mission payload includes the GRB monitor BDRG, wide-field optical cameras SHOK, and the UFFO instrument. Data are recorded mainly by the event trigger provided by the BDRG instrument, which measures the spectral and temporal properties of the burst in the energy range 10–3000 keV. The BDRG instrument also provides estimation of the source coordinates by comparing the readings of three differently directed detectors with an accuracy of several degrees. Wide-field SHOK optical cameras have a field of view of ~20° × 40°. They fix a set of images with a frequency of about five frames per second prior to the trigger and another set immediately after the trigger. The UFFO instrument includes the UBAT telescope with a coded mask for measurements in hard X-ray and soft gamma-ray ranges and an optical telescope with a slewing mirror (SMT) that can be directed on the GRB source for a time ~1 s for measuring GRB prompt emission in the early stages. In response to an BDRG trigger signal, the real-time data on a detected GRB are transmitted to the Earth via Globalstar network to the Gamma-ray Coordinates Network (GCN) and ground-based observatories. During observations on the Lomonosov satellite, 20 gamma-ray bursts were detected and catalogued. Several gamma-ray bursts were also detected in the Vernov satellite experiment. An example of such an event is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fiducial reference for the HIPPARCOS reference system

The groundwork was prepared for observations by the Hubble Space Telescope (HST) to tie the coordinate system of the European Astrometry Satellite HIPPARCOS to an extragalactic (VLBI) reference frame, and to determine the rotation of the HIPPARCOS frame with respect to the extragalactic frame. A total of 90 Extragalactic Optical Objects (EGOs) were determined in the vicinity (angular separation less than 18 arcminutes) of 160 HIPPARCOS stars (brighter than about 11.0 magnitude, mostly SAO stars brighter than 10.5), evenly distributed over the sky, to be used to tie the HIPPARCOS system to the Extragalactic Reference Frame. The pairs are to be observed with the HST Fine Guidance Sensors (FGS), sometimes in conjunction with the HST Planetary Camera, in order to determine the relative positions and motions of the individual HIPPARCOS stars with respect to the EGOs. The data base which contains the optical information used to generate the HST Guaranteed Observing Time (GTO) proposal is included.

Duncombe, R. L.↗

Targeting an asteroid - The Galileo spacecraft's encounter with 951 Gaspra

On 1991 October 29, the Galileo spacecraft provided the first in situ observations of an asteroid. To a significant degree, the successful encounter with asteroid 951 Gaspra was made possible by the high accuracy of the ground-based Gaspra ephemeris and the refinement to this initial ephemeris provided by the use of optical navigation images taken on board the spacecraft itself. The success of these celestial navigation efforts was dramatically demonstrated when Gaspra appeared in the central frame of the large mosaic of CCD images-less than one asteroid diameter from Gaspra's expected location in the camera's field of view. The corrections to Gaspra's ground-based ephemeris, based upon the optical on-board navigation images, were less than 80 km. The ground-based observation program that went into this ephemeris development is discussed and the accuracy of the ephemeris is used to validate the assumptions that went into the error analysis studies.

Yeomans, D. K.↗