Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILTRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Does Renal Artery Supply Indicate Treatment Success of Renal Denervation?

PurposeRenal denervation (RDN) emerged as an innovative interventional antihypertensive therapy. With the exception of pretreatment blood pressure (BP) level, no other clear predictor for treatment efficacy is yet known. We analyzed whether the presence of multiple renal arteries has an impact on BP reduction after RDN.MethodsFifty-three patients with treatment-resistant hypertension (office BP {>=} 140/90 mmHg and 24-h ambulatory BP monitoring ({>=}130/80 mmHg) underwent bilateral catheter-based RDN. Patients were stratified into one-vessel (OV) (both sides) and at least multivessel (MV) supply at one side. Both groups were treated on one vessel at each side; in case of multiple arteries, only the dominant artery was treated on each side.ResultsBaseline clinical characteristics (including BP, age, and estimated glomerular filtration rate) did not differ between patients with OV (n = 32) and MV (n = 21). Office BP was significantly reduced in both groups at 3 months (systolic: OV -15 {+-} 23 vs. MV -16 {+-} 20 mmHg; diastolic: OV -10 {+-} 12 vs. MV -8 {+-} 11 mmHg, both p = NS) as well as 6 months (systolic: OV -18 {+-} 18 vs. MV -17 {+-} 22 mmHg; diastolic: OV -10 {+-} 10 vs. -10 {+-} 12 mmHg, both p = NS) after RDN. There was no difference in responder rate (rate of patients with office systolic BP reduction of at least 10 mmHg after 6 months) between the groups.ConclusionIn patients with multiple renal arteries, RDN of one renal artery-namely, the dominant one-is sufficient to induce BP reduction in treatment-resistant hypertension.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization with a Mixture of Absolute Ethanol and Iodized Oil for Poorly Visualized Endophytic Renal Masses Prior to CT-Guided Percutaneous Cryoablation

PurposeTo retrospectively evaluate the feasibility of transcatheter arterial embolization (TAE) using a mixture of absolute ethanol and iodized oil to improve localization of endophytic renal masses on unenhanced computed tomography (CT) prior to CT-guided percutaneous cryoablation (PCA).Materials and MethodsOur institutional review board approved this retrospective study. From September 2011 to June 2015, 17 patients (mean age, 66.8 years) with stage T1a endophytic renal masses (mean diameter, 26.5 mm) underwent TAE using a mixture of absolute ethanol and iodized oil to improve visualization of small and endophytic renal masses on unenhanced CT prior to CT-guided PCA. TAE was considered successful that accumulated iodized oil depicted whole of the tumor edge on CT. PCA was considered successful when the iceball covered the entire tumor with over a 5 mm margin. Oncological and renal functional outcomes and complications were also evaluated.ResultsTAE was successfully performed in 16 of 17 endophytic tumors. The 16 tumors were performed under CT-guided PCA with their distinct visualization of localization and safe ablated margin. During the mean follow-up period of 15.4 ± 5.1 months, one patient developed local recurrence. Estimated glomerular filtration rate declined by 8 % with statistical significance (P = 0.01). There was no procedure-related significant complication.ConclusionTAE using a mixture of absolute ethanol and iodized oil to improve visualization of endophytic renal masses facilitated tumor localization on unenhanced CT, permitting depiction of the tumor edge as well as a safe margin for ablation during CT-guided PCA, with an acceptable decline in renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon dioxide Angiography-Guided Renal-Related Interventions in Patients with Takayasu Arteritis and Renal Insufficiency

BackgroundUse of iodinated contrast agents for angiography in patients with renal insufficiency risks further deterioration of renal function and its adverse sequelae.ObjectiveTo study the effectiveness and safety of carbon dioxide (CO{sub 2}) angiography in guiding percutaneous renal-related interventions in patients with Takayasu arteritis and renal insufficiency.MethodsData on CO{sub 2} angiography-guided interventions were obtained from a 23-year database of 692 Takayasu arteritis patients who underwent percutaneous interventions and were analyzed retrospectively. Follow-up data were also obtained. The CO{sub 2} angiography system used was developed in-house and was pressure-driven.ResultsSeven patients (6 female, age 16–59 years, baseline serum creatinine 1.62–4.55 mg/dl, estimated glomerular filtration rate 12.2–36.9 ml/min/1.73 m{sup 2}) underwent CO{sub 2} angiography-guided interventions: five underwent angioplasty or stenting to treat six stenotic/occluded renal arteries, one underwent extensive endovascular repair for spontaneous focal abdominal aortic dissection with false lumen aneurysm and aorto-iliac true lumen narrowing, and one underwent balloon dilatation of previously deployed aortic stents used to treat aortic occlusion at two levels. Follow-up (median 5 years, range 2 months–16 years) was obtained in all patients. All the procedures were successful and resulted in relief of symptoms, better blood pressure control, improvement in left ventricular systolic function and recovery or stabilization of renal function. There were no early or late complications related to CO{sub 2} angiography. Three renal lesions that had restenosis at follow-up were managed successfully by repeat intervention.ConclusionCO{sub 2} angiography-guided renal-related interventions are effective and safe in patients with Takayasu arteritis and renal insufficiency; they significantly improve the care of such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of a Pretreatment CT-Based Modified RENAL Nephrometry Score in Predicting Renal Function After Cryotherapy for T1a Renal Mass

Purpose: We investigated the usefulness of the modified RENAL nephrometry (mRN) scoring system for predicting post-cryotherapy renal function in patients with T1a renal mass. Patients and Methods: A total of 75 patients with a T1a renal mass were enrolled. The mRN score was determined based on the tumor size, the tumor’s exophytic/endophytic properties, the tumor’s nearness to the collecting system, and the anterior/posterior location of the kidney. The change in the estimated glomerular filtration rate (ΔeGFR) was calculated as follows: ΔeGFR = 100 × ([pretreatment eGFR − eGFR at 6 months after cryotherapy]/pretreatment eGFR). Based on the ΔeGFR results, we classified the patients into two groups: a preserved renal function group (ΔeGFR < 10%) and an impaired renal function group (ΔeGFR ≥ 10%). We then analyzed the relationships between the mRN score and ΔeGFR and between the mRN score and the chronic kidney disease (CKD) stage. Results: The mean ΔeGFR for all patients was 5.5%. The mRN scores of the preserved renal function group (5.8 ± 0.3) were significantly lower than those of the impaired group (7.4 ± 0.3) (p < 0.001). When the mRN score cutoff value was set at 7 points, the mRN had 67.7% sensitivity, 72.7% specificity, 61.8% positive predictive value (PPV), 76.1% negative predictive value (NPV), and 70.7% accuracy for predicting impaired renal function. For predicting a deterioration of CKD stage, the mRN had 92.9% sensitivity, 67.2% specificity, 39.4% PPV, 97.6% NPV, and 72% accuracy. Conclusion: Our newly proposed modified RENAL nephrometry score was suggested to be useful for predicting renal function after renal cryotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Promising Technology for Reprocessing Complex Uranium Ores from the Elkon Deposit

The results of research on reprocessing of complex uranium ores from the Elkon deposit with recovery of uranium, gold, silver, and vanadium by methods of radiometric sorting, combining of autoclave and atmospheric leaching of ore followed by sorption and extraction recovery of valuable components, are presented. The capacity was 90 mg/g in sorption of uranium on strongly basic anionite and the uranium concentration ≤0.003 g/dm{sup 3} in sorption filtrates. The choice of eluent is determined by the formulation of the problem of obtaining the finished uranium product of the requisite form and quality. A fundamentally new composition of the extracting agent is proposed for direct extraction of uranium from nitrate-containing solutions. An iron-vanadium concentrate with vanadium and iron content 2.58 and 22.8%, respectively, suitable for subsequent reprocessing, was obtained. The anionite PuroGold S-992 is recommended for recovery of gold and silver. The gold and silver concentrations in the commercial desorbate were 270 and 380 mg/dm{sup 3}, respectively; a gold-containing concentrate was obtained.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Potential biological control agents of Geosmithia morbida restrict fungal pathogen growth via mycoparasitism and antibiosis

Abstract Thousand cankers disease of Juglans (walnut) and Pterocarya (wingnut) spp. (Fagales: Juglandaceae) is caused by the fungal pathogen Geosmithia morbida Kolarík, Freeland, Utley, and Tisserat (Hypocreales: Bionectriaceae) and bark beetle pest/vector, Pityophthorus juglandis Blackman (Coleoptera: Curculionidae). To further the development of biological management strategies for thousand cankers disease, we assessed the ability of 14 endophytic Trichoderma (Hypocreales: Hypocreaceae) isolates and the commercially available isolate T. afroharzianum strain KRL-AG2 to inhibit the in vitro growth of three different G. morbida isolates via mycoparasitism and antibiosis. To identify factors that may affect field success of candidate biological control agents, we quantified the growth responses of Trichoderma spp. and the commercially available entomopathogenic fungus, Beauveria bassiana (Bals.-Criv.) Vuill. (Hypocreales: Cordycipitaceae) strain GHA, to the plant secondary metabolite and antimicrobial compound, juglone in vitro. A total of 12 Trichoderma isolates (from six different Trichoderma species) demonstrated antagonistic activity towards G. morbida in dual-plate assays. Juglone consistently reduced the growth of B. bassiana strain GHA and 14 of the 15 screened Trichoderma isolates in vitro. Additionally, one metabolite-producing Trichoderma isolate, TN4-47, completely inhibited the growth of all three G. morbida isolates across all tested metabolite concentrations and had comparatively greater tolerance to juglone compared to other Trichoderma isolates. Future lines of research should focus on characterizing the active antagonistic compound present in the metabolite filtrates, determine the mode of action of the active component(s), and elucidate how abiotic and biotic factors may influence the growth, persistence, and antagonistic activity of candidate biological control agents in planta .

59 BASIC BIOLOGICAL SCIENCES↗

Fischer–Tropsch Synthesis: Effect of Reducing Agent for Aqueous-Phase Synthesis Over Ru Nanoparticle and Supported Ru Catalysts

The effect of the reducing agent on the performance of a ruthenium nanoparticle catalyst was investigated during aqueous-phase Fischer–Tropsch synthesis using a 1 L stirred tank reactor in the batch mode of operation. For the purpose of comparison, the activity and selectivity of NaY zeolite supported Ru catalyst were also studied. NaBH 4 and hydrogen were used as reducing agents in our study, and hydrogen reduced catalysts exhibited higher activities than the NaBH 4 reduced catalysts, because of higher extent of reduction and a relatively lower tendency toward agglomeration of Ru particles. The Ru nanoparticle catalyst displayed higher activities than the NaY zeolite supported Ru catalyst for both reducing agents. NaBH 4 reduced catalysts are less active and the carbon dioxide selectivity is higher than the hydrogen reduced catalysts. The activity of the supported Ru catalyst (Ru/NaY) was 75 % of that of the Ru nanoparticle catalyst, and has the benefit of easy wax/catalyst slurry separation by filtration. Finally, the hydrogen reduced supported Ru catalyst exhibited superior selectivity towards hydrocarbons (higher C 5+ selectivity and lower selectivity to methane) than all other catalysts tested.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

PVDF/PAN Blend Membrane: Preparation, Characterization and Fouling Analysis

Ultrafiltration membranes were prepared from blend of the poly(vinylidene fluoride) (PVDF) with polyacrylonitrile (PAN) via phase inversion method induced by immersion precipitation. N,N-dimethylacetamide (DMAc) and water were used as solvent and coagulant (non-solvent), respectively. The effect of blending ratio on the morphology and antifouling behavior of the prepared membranes was investigated. The performance of the membranes was evaluated by using cross flow filtration of pure water and buffered bovine serum albumin (BSA) solution as feed. Contact angle measurements indicated that the hydrophilicities of the PVDF/PAN membranes increased by increasing PAN concentration in the casting solution. The minimum BSA rejection was obtained for the membrane with 10% of PAN. However, higher values of PAN result in pore blockage of the membrane and an increase in the irreversible fouling resistance.

36 MATERIALS SCIENCE↗

Electrospinning: Polymer Nanofibre Adsorbent Applications for Metal Ion Removal

In recent decades, electrospun nanofibres have been applied to different potential fields such as sensor devices, tissue engineering scaffolds, wound dressing, filtration, drug delivery, etc. and significant review papers have been published in these fields. However, the use of electrospun nanofibres in metal ion adsorption is emerging and comparatively innovative. Nanofibre materials hold great potential in advancing the growth of metallurgical technologies and progress for the separation of metallic ions from various sources. The physico-chemical removal processes of adsorption use nanofibres due to their large surface area to volume ratio and the availability of a wide variety of chemical and morphological modification methods. In this review paper, research and developments related to electrospun polymer nanofibre for metal ion removal is presented. The review highlights the emerging and increasing use of electrospun nanofibres for metal ion adsorption especially for hazardous metals. Fundamental understanding of the electrospinning fabrication process, working parameters as they affect fibre morphologies, solvents and polymers used in electrospinning is discussed. This work summarizes the current status of process technique development and ideas in the research and use of electrospun nanofibres in heavy metal ion adsorption to address environmental problems from contaminated water.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Isolation and Characterization of Cellulose Micro/Nanofibrils from Douglas Fir

Cellulose micro/nanofibrils were successfully extracted from softwood Douglas fir in three distinct stages. Initially raw Douglas fir wood chips were subjected to a hot water extraction (HWE) treatment. Then HWE treated cellulosic fibers underwent a bleaching process followed by a mild ultrasonication. Chemical composition analysis according to ASTM standards confirmed that most of hemicelluloses and nearly all lignin were removed during the first two stages, respectively. Microscopy studies showed formation of nanofibrils during the ultrasonication process, and increasing ultrasonication time led to generation of greater percentage of nanofibrils. With the removal of the matrix materials, the crystallinity of the cellulosic fibers was increased, whereas thermal stability was maintained. HWE opened up the cell wall structure, thereby facilitating the subsequent fractionation into micro/nanofibrils. The obtained cellulose micro/nanofibrils could serve as reinforcing material in composite products or raw material for other applications, such as filtration membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Development of Eco-Friendly Dye Microcapsules for Wool Fabric Dyeing Application

There is an urgent need to reduce the environmental impacts of wool fabrics dyeing process while maintain its dyeing effects. Microcapsule technology is a potential option which could be used to move towards cleaner production process and to cope with ever-increasing demands for wool fiber dyeing efficiency. Reactive dyestuff microcapsules were prepared via reverse-phase evaporation methods and then auxiliary-free dye microcapsules were used to dye the wool fabrics. Transmission electron microscope images and fourier transform infrared showed that dye microcapsules possessed a spherical core–shell structure with a diameter of about 500 ± 5 nm. The processing factors were analyzed and optimized by using response surface methodology to improve the encapsulation rate. Higher fixation rate (80.13% vs. 72.03%) of dyed wool fabric, while lower absorbance of dyestuff (0.071 vs. 0.96), chemical oxygen demand (COD, 190 mg/L vs. 1395 mg/L) and biological oxygen demand (BOD{sub 5}, 83.5 mg/L vs. 649.3 mg/L) of residual wastewater were observed by using microcapsule dyeing, compared with conventional dyeing process. In addition, the results also demonstrated that the filtrated wastewater of microcapsule dyeing can be recycled as dyebath to replace distill water. Thus, we innovatively produced a novel dye microcapsule for wool fabric dyeing application, advancing greatly in reducing the discharge of contaminants to environment, but also in economizing water and energy resources.

36 MATERIALS SCIENCE↗

Enhanced Magnetoresistance in In-Plane Monolayer MoS{sub 2} with CrO{sub 2} Electrodes

Magnetoresistance of monolayer MoS{sub 2} is reported to increase when used in in-plane configuration with CrO{sub 2} half-metal ferromagnet (HMF) electrodes. Density functional theory (DFT)- and non-equilibrium Green’s function (NEGF)-based simulations show that high magnetoresistance (MR) values of ∼860% can be achieved in in-plane monolayer MoS{sub 2} with CrO{sub 2} electrodes, which is much higher than the MR value of ∼300% for nine-layer and the MR value of ∼70% for single-layer out-of-plane MoS{sub 2} reported in Dolui et al., Phys. Rev. B 90(R), 041401 (2014) past by other researchers. High spin-injection efficiency ∼100% is also obtained at high bias voltages. High MR and perfect spin filtration suggests the importance of this configuration in spintronics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temporally and Spatially Resolved x-ray Fluorescence Measurements of in-situ Drug Concentration in Metered-Dose Inhaler Sprays

Drug concentration measurements in MDI sprays are typically performed using particle filtration or laser scattering. These techniques are ineffective in proximity to the nozzle, making it difficult to determine how factors such as nozzle design will affect the precipitation of co-solvent droplets in solution-based MDIs, and the final particle distribution. In optical measurements, scattering from the constituents is difficult to separate. We present a novel technique to directly measure drug distribution. A focused x-ray beam was used to stimulate x-ray fluorescence from the bromine in a solution containing 85% HFA, 15% ethanol co-solvent, and 1 / IPBr. Instantaneous concentration measurements were obtained with 1 ms temporal resolution and 5 spatial resolution, providing information in a region that is inaccessible to many other diagnostics. The drug remains homogeneously mixed over time, but was found to be higher at the centerline than at the periphery. This may have implications for oropharyngeal deposition in vivo. Measurements in the dynamic, turbulent region of MDIs allow us to understand the physical links between formulation, inspiration, and geometry on final particle size and distribution. This will ultimately lead to a better understanding of how MDI design can be improved to enhance respirable fraction.

fluorescence↗

Multiscale Persistent Functions for Biomolecular Structure Characterization

Here in this paper, we introduce multiscale persistent functions for biomolecular structure characterization. The essential idea is to combine our multiscale rigidity functions (MRFs) with persistent homology analysis, so as to construct a series of multiscale persistent functions, particularly multiscale persistent entropies, for structure characterization. To clarify the fundamental idea of our method, the multiscale persistent entropy (MPE) model is discussed in great detail. Mathematically, unlike the previous persistent entropy (Chintakunta et al. in Pattern Recognit 48(2):391–401, 2015; Merelli et al. in Entropy 17(10):6872–6892, 2015; Rucco et al. in: Proceedings of ECCS 2014, Springer, pp 117–128, 2016), a special resolution parameter is incorporated into our model. Various scales can be achieved by tuning its value. Physically, our MPE can be used in conformational entropy evaluation. More specifically, it is found that our method incorporates in it a natural classification scheme. This is achieved through a density filtration of an MRF built from angular distributions. To further validate our model, a systematical comparison with the traditional entropy evaluation model is done. Additionally, it is found that our model is able to preserve the intrinsic topological features of biomolecular data much better than traditional approaches, particularly for resolutions in the intermediate range. Moreover, by comparing with traditional entropies from various grid sizes, bond angle-based methods and a persistent homology-based support vector machine method (Cang et al. in Mol Based Math Biol 3:140–162, 2015), we find that our MPE method gives the best results in terms of average true positive rate in a classic protein structure classification test. More interestingly, all-alpha and all-beta protein classes can be clearly separated from each other with zero error only in our model. Finally, a special protein structure index (PSI) is proposed, for the first time, to describe the “regularity” of protein structures. Basically, a protein structure is deemed as regular if it has a consistent and orderly configuration. Our PSI model is tested on a database of 110 proteins; we find that structures with larger portions of loops and intrinsically disorder regions are always associated with larger PSI, meaning an irregular configuration, while proteins with larger portions of secondary structures, i.e., alpha-helix or beta-sheet, have smaller PSI. Essentially, PSI can be used to describe the “regularity” information in any systems.

59 BASIC BIOLOGICAL SCIENCES↗

Cellulolytic and Xylanolytic Potential of High β-Glucosidase-Producing Trichoderma from Decaying Biomass

Availability, cost and efficiency of microbial enzymes for lignocellulose bioconversion are central to sustainable biomass ethanol technology. Fungi enriched from decaying biomass and surface soil mixture displayed an array of strong cellulolytic and xylanolytic activities. Strains SG2 and SG4 produced a promising array of cellulolytic and xylanolytic enzymes including β-glucosidase, usually low in cultures of Trichoderma species. Nucleotide sequence analysis of internal transcribed spacer 2 (ITS2) region of rRNA gene revealed that strains SG2 and SG4 are closely related to Trichoderma inhamatum, Trichoderma piluliferum and Trichoderma aureoviride. Trichoderma sp. SG2 correspondingly displayed as much as 9.84±1.12, 48.02±2.53 and 30.10±1.11 units mL-1 of cellulase, xylanase and β-glucosidase. Ten times dilution of culture supernatant of strain SG2 revealed that activities were about 5.34, 8.45, and 2.05 orders of magnitude higher than observed in crude culture filtrate for cellulase, xylanase, and β-glucosidase respectively, indicating that more enzymes are present to contact with substrates in biomass sacharification. In parallel experiments Trichoderma species SG2 and SG4 produced more β-glucosidase than the industrial strain Trichoderma reesei RUT-C30. Results indicate that strains SG2 and SG4 have potential for low cost in-house production of primary lignocellulose-hydrolyzing enzymes for production of biomass saccharides and biofuel in the field.

09 BIOMASS FUELS↗

Modification of a Superficial X-Ray Therapy Machine for Rectal Contact Therapy

X-ray therapy of superficial rectal cancers using a hand-held 50 kV contact unit (Philips RT-50) in a technique first described by Papillon had reached a point of widening clinical acceptability when the manufacturer of this equipment discontinued its production. To pursue this endocavitary approach to rectal therapy, technical modifications have to be made to conventional superficial x-ray therapy machines. Advantages over the original Papillon method include remote viewing of the lesion through the proctoscopic cone and a lower radiation exposure for the operator. We have evaluated a Bucky Combination Therapy Unit under conditions in which the operating voltage (65 kV), target skin distance (23.6 cm), and added filtration (0.39 mm Al) were selected in order to match as closely as possible the beam penetration characteristics of the “standard” (Papillon) technique. With this equipment, the thermal characteristics of the tube anode and housing limit the amount of radiation that can be delivered before a “rest period” for the machine is needed. In practice, 3 minutes of irradiation at an exposure rate of 500 R/min can be performed followed by an interval of 3 minutes before irradiation can be resumed.

61 RADIATION PROTECTION AND DOSIMETRY↗