Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIBER OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Recent Advances in Machine Learning for Fiber Optic Sensor Applications

Over the last three decades, fiber optic sensors (FOS) have gained a lot of attention for their wide range of monitoring applications across many industries, including aerospace, defense, security, civil engineering, and energy. FOS technologies hold great promise to form the backbone for next‐generation intelligent sensing platforms that offer long‐distance, high‐accuracy, distributed measurement capabilities and multiparametric monitoring with resilience to harsh environmental conditions. The major limitations posed by FOS are 1) cross‐sensitivity, 2) enormous volume and large data generation, 3) low data processing speed, 4) degradation of signal‐to‐noise ratio over the fiber length, and 5) overall cost of sensor and interrogator systems. These challenges can be overcome by building advanced data analytics engines enabled by recent breakthroughs in machine learning (ML) and artificial intelligence (AI). This article presents a comprehensive review of recent studies that integrate ML and AI algorithms with FOS technologies. This review also highlights several FOS technology development directions that promise a significant impact on widespread use for several industrial applications, with an emphasis on energy systems monitoring. A perspective on future directions for further research development is also provided.

97 MATHEMATICS AND COMPUTING↗

Test Port for Fiber-Optic-Coupled Laser Altimeter

A test port designed as part of a fiber optic coupled laser altimeter receiver optical system allows for the back-illumination of the optical system for alignment verification, as well as illumination of the detector(s) for testing the receiver electronics and signal-processing algorithms. Measuring the optical alignment of a laser altimeter instrument is difficult after the instrument is fully assembled. The addition of a test port in the receiver aft-optics allows for the back-illumination of the receiver system such that its focal setting and boresight alignment can be easily verified. For a multiple-detector receiver system, the addition of the aft-optics test port offers the added advantage of being able to simultaneously test all the detectors with different signals that simulate the expected operational conditions. On a laser altimeter instrument (see figure), the aft-optics couple the light from the receiver telescope to the receiver detector(s). Incorporating a beam splitter in the aft-optics design allows for the addition of a test port to back-illuminate the receiver telescope and/or detectors. The aft-optics layout resembles a T with the detector on one leg, the receiver telescope input port on the second leg, and the test port on the third leg. The use of a custom beam splitter with 99-percent reflection, 1-percent transmission, and a mirrored roof can send the test port light to the receiver telescope leg as well as the detector leg, without unduly sacrificing the signal from the receiver telescope to the detector. The ability to test the receiver system alignment, as well as multiple detectors with different signals without the need to disassemble the instrument or connect and reconnect components, is a great advantage to the aft-optics test port. Another benefit is that the receiver telescope aperture is fully back-illuminated by the test port so the receiver telescope focal setting vs. pressure and or temperature can be accurately measured (as compared to schemes where the aperture is only partially illuminated). Fiber-optic coupling the test port also allows for the modularity of testing the receiver detectors with a variety of background and signal laser sources without the need of using complex optical set-ups to optimize the efficiency of each source.

Ramos Izquierdo, Luis↗

A unified materials approach to mitigating optical nonlinearities in optical fiber. III. Canonical examples and materials road map

Abstract This paper, Part III in the Trilogy (Ballato, Cavillon, Dragic, 2018; Dragic, Cavillon, Ballato, et al ., 2018a,b), provides a road map for the development of simple core/clad optical fibers whose enhanced performance—in particular, marked reductions in optical nonlinearities—is achieved materially and not through the more conventional present routes of geometrically complex fiber design. More specifically, the material properties that give rise to Brillouin, Raman and Rayleigh scattering, transverse mode instabilities ( TMI ), and n 2 ‐mediated nonlinear effects are compiled and results on a wide range of optical fibers are discussed with a focus on trends in performance with glass composition. Furthermore, optical power scaling estimations as well as binary and ternary property diagrams associated with Rayleigh scattering, the Brillouin gain coefficient ( BGC ) and the thermo‐optic coefficient (d n /d T ) are developed and employed to graphically represent general trends with composition along with compositional targets for a single intrinsically low nonlinearity, silica‐based optical fiber that can achieve the power scaling goals of future high energy fiber laser applications. A foundational finding of this work is that the high‐silica content optical fibers fabricated using conventional chemical vapor deposition methods will not suffice to meet the power scaling demands of future high‐power and high‐energy fiber lasers.

36 MATERIALS SCIENCE↗

Note: Simple vacuum feedthrough for optical fiber with SubMiniature version A connectors at both ends

We present a simple way to insert an optical fiber, with existing standard SubMiniature version A connectors on both ends into a vacuum system. The fitting is tested in scanning electron microscope, at working pressures down to 2 × 10{sup −5} mbar for cathodoluminescent measurements. With slight modifications this fitting could be successfully adapted for optical fiber insertion into pressurized systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conservation of the photon number in the generalized nonlinear Schroedinger equation in axially varying optical fibers

We reexamine the derivation of the generalized nonlinear Schroedinger equation in the case of nonaxially uniform optical fibers, taking into account the longitudinal and spectral evolutions of all pertinent linear parameters. Our theory leads to an improved form of this equation that highlights an additional term, which ensures the conservation of the total photon number in nonuniform optical fibers in the absence of attenuation. Numerical simulations confirm the validity of this theory in the context of a Raman-induced soliton self-frequency shift, emission of Cherenkov radiation, and a soliton blue shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SMART conductor on round core (CORC ® ) wire via integrated optical fibers

Superconducting cables based on high temperature superconductors (HTS) are necessary for applications requiring large currents and low inductance, such as compact fusion reactors. In this paper, we report the proof-of-concept of a SMART Conductor on Round Core (CORC ® ) wire realized via integration of optical fibers into the copper core. A SMART CORC ® wire with integrated optical fibers was manufactured and its capabilities have been experimentally demonstrated. Results show that by interrogating the optical fibers via Rayleigh backscattering, a Spectral Shift signal as a function of time and position along the cable can be used to detect and locate hot-spots that are developed within the wire or its terminations. It has been found that highly localized current injection into the terminations could initiate hot-spots within the cable at locations where current redistribution between tapes occur. This effect is virtually eliminated when adequate current connections are used that inject current evenly along the cable terminations. Normal zone propagation velocities have been calculated as a function of time using Spectral Shift data for a heater-induced quench as well as a quench induced by overcurrent. In both cases the normal zone propagation velocity was about 6 cm s -1 , but in the heater-induced experiment it was preceded by 500 ms of slower propagation at 2.5 cm s -1 .

Physics↗

Integrability aspects with optical solitons of a generalized variable-coefficient N-coupled higher order nonlinear Schroedinger system from inhomogeneous optical fibers

For describing the long-distance communication and manufacturing problems of N fields propagation in inhomogeneous optical fibers, we consider a generalized variable-coefficient N-coupled nonlinear Schroedinger system with higher order effects such as the third-order dispersion, self-steepening and self-frequency shift. Using the Painleve singularity structure analysis, we obtain two cases for this system to admit the Painleve property. Then for case (1) we derive the optical dark solitons via solving the Hirota bilinear equations; and based on the obtained (2N+1)x(2N+1) Lax pair, we construct the Darboux transformation to obtain the optical bright solitons (including the multisoliton profiles) for case (2). Finally, the features of optical solitons (both dark and bright ones) in inhomogeneous optical fibers are analyzed and graphically discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum sized Ag nanocluster assisted fluorescence enhancement in Tm{sup 3+}-Yb{sup 3+} doped optical fiber beyond plasmonics

We report a process for enhancing fluorescence emission from conventional rare earth ions in optical fiber by metal nanocluster (MNC) in nonresonant indirect pumping. The process is completely different from formal metal enhanced fluorescence phenomenon as the MNCs are too small in size to support localized surface plasmon and the excitation wavelength is far from plasmon resonance frequency. We used an established theory of two coupled oscillators to explain the simultaneous enhancement of Ytterbium (Yb{sup 3+}) and Thulium (Tm{sup 3+}) emission by silver (Ag) NCs under nonresonant pumping in optical fiber. The fiber is pumped with a 980 nm fiber pigtailed laser diode with input power of 20–100 mW to excite the Yb{sup 3+}. Four times enhancement of Yb{sup 3+} emission of 900–1100 nm and Tm{sup 3+} upconversion emission around 474 nm, 650 nm, and 790 nm is observed in the fiber with Ag NCs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical fiber voltage sensors for broad temperature ranges

We describe the development of an optical fiber ac voltage sensor for aircraft and spacecraft applications. Among the most difficult specifications to meet for this application is a temperature stability of +/- 1 percent from -65 C to +125 C. This stability requires a careful selection of materials, components, and optical configuration with further compensation using an optical-fiber temperature sensor located near the sensing element. The sensor is a polarimetric design, based on the linear electro-optic effect in bulk Bi4Ge3O12. The temperature sensor is also polarimetric, based on the temperature dependence of the birefringence of bulk SiO2. The temperature sensor output is used to automatically adjust the calibration of the instrument.

Rose, A. H.↗

Indium tin oxide and silver based fiber optic SPR sensor: an experimental study

Fabrication and characterization of SPR based fiber optic sensor utilizing bi-layers of ITO-Ag is presented. Effects of thicknesses of ITO and Ag layers on the sensitivity of sensor are studied experimentally. Sensitivity ascends as the thickness of Ag layer is enhanced till 30 nm and it starts decreasing as the thickness of Ag layers is further increased beyond 30 nm. SPR sensor based on 40 nm thick ITO layer-30 nm thick Ag layer demonstrates highest sensitivity.

36 MATERIALS SCIENCE↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fiber optic sensor for ophthalmic refractive diagnostics

This paper demonstrates the application of a lensless fiber optic spectrometer (sensor) to study the onset of cataracts. This new miniaturized and rugged fiber optic probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for cold-induced cataract in excised bovine eye lenses, and aging effects in excised human eye lenses. The device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics.

Ansari, Rafat R.↗

Development of plasma bolometers using fiber-optic temperature sensors

Measurements of radiated power in magnetically confined plasmas are important for exhaust studies in present experiments and expected to be a critical diagnostic for future fusion reactors. Resistive bolometer sensors have long been utilized in tokamaks and helical devices but suffer from electromagnetic interference (EMI). Results are shown from initial testing of a new bolometer concept based on fiber-optic temperature sensor technology. A small, 80 μm diameter, 200 μm long silicon pillar attached to the end of a single mode fiber-optic cable acts as a Fabry–Pérot cavity when broadband light, λ{sub o} ∼ 1550 nm, is transmitted along the fiber. Changes in temperature alter the optical path length of the cavity primarily through the thermo-optic effect, resulting in a shift of fringes reflected from the pillar detected using an I-MON 512 OEM spectrometer. While initially designed for use in liquids, this sensor has ideal properties for use as a plasma bolometer: a time constant, in air, of ∼150 ms, strong absorption in the spectral range of plasma emission, immunity to local EMI, and the ability to measure changes in temperature remotely. Its compact design offers unique opportunities for integration into the vacuum environment in places unsuitable for a resistive bolometer. Using a variable focus 5 mW, 405 nm, modulating laser, the signal to noise ratio versus power density of various bolometer technologies are directly compared, estimating the noise equivalent power density (NEPD). Present tests show the fiber-optic bolometer to have NEPD of 5-10 W/m{sup 2} when compared to those of the resistive bolometer which can achieve <0.5 W/m{sup 2} in the laboratory, but this can degrade to 1-2 W/m{sup 2} or worse when installed on a tokamak. Concepts are discussed to improve the signal to noise ratio of this new fiber-optic bolometer by reducing the pillar height and adding thin metallic coatings, along with improving the spectral resolution of the interrogator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical fiber cable chemical stripping fixture

An elongated fixture handle member is connected to a fixture body member with both members having interconnecting longitudinal central axial bores for the passage of an optical cable therethrough. The axial bore of the fixture body member, however, terminates in a shoulder stop for the outer end of a jacket of the optical cable covering both an optical fiber and a coating therefor, with an axial bore of reduced diameter continuing from the shoulder stop forward for a predetermined desired length to the outer end of the fixture body member. A subsequent insertion of the fixture body member including the above optical fiber elements into a chemical stripping solution results in a softening of the exposed external coating thereat which permits easy removal thereof from the optical fiber while leaving a desired length coated fiber intact within the fixture body member.

Kolasinski, John R.↗

Fiber-Optic Micrometeoroid/Orbital Debris Impact Detector System

A document describes a reliable, lightweight micrometeoroid/orbital debris (MMOD) detection system that can be located at strategic positions of "high consequence" to provide real-time warning of a penetration, its location, and the extent of the damage to a spacecraft. The concept is to employ fiber-optic sensors to detect impact damage and penetration of spacecraft structures. The fibers are non-electrical, employ light waves, and are immune to electromagnetic interference. The fiber-optic sensor array can be made as a stand-alone product, being bonded to a flexible membrane material or a structure that is employed as a MMOD shield material. The optical sensors can also be woven into hybrid MMOD shielding fabrics. The glass fibers of the fiber-optic sensor provide a dual purpose in contributing to the breakup of MMOD projectiles. The grid arrays can be made in a modular configuration to provide coverage over any area desired. Each module can be connected to a central scanner instrument and be interrogated in a continuous or periodic mode.

Christiansen, Eric L.↗

WE-DE-201-07: Measurement of Real-Time Dose for Tandem and Ovoid Brachytherapy Procedures Using a High Precision Optical Fiber Radiation Detector

Purpose: Development of a novel on-line dosimetry tool is needed to move toward patient-specific quality assurance measurements for Ir-192 HDR brachytherapy to verify accurate dose delivery to the intended location. This work describes the development and use of a nano-crystalline yttrium oxide inorganic scintillator based optical-fiber detector capable of acquiring real-time high-precision dose measurements during tandem and ovoid (T&O) gynecological (GYN) applicator Ir-192 HDR brachytherapy procedures. Methods: An optical-fiber detector was calibrated by acquiring light output measurements in liquid water at 3, 5, 7, and 9cm radial source-detector-distances from an Ir-192 HDR source. A regression model was fit to the data to describe the relative light output per unit dose (TG-43 derived) as a function of source-detector-distance. Next, the optical-fiber detector was attached to a vaginal balloon fixed to a Varian Fletcher-Suit-Delclos-style applicator (to mimic clinical setup), and localized by acquiring high-resolution computed tomography (CT) images. To compare the physical point dose to the TPS calculated values (TG-43 and Acuros-BV), a phantom measurement was performed, by submerging the T&O applicator in a liquid water bath and delivering a treatment template representative of a clinical T&O procedure. The fiber detector collected scintillation signal as a function of time, and the calibration data was applied to calculate both real-time dose rate, and cumulative dose. Results: Fiber cumulative dose values were 100.0cGy, 94.3cGy, and 348.9cGy from the tandem, left ovoid, and right ovoid dwells, respectively (total of 443.2cGy). A plot of real time dose rate during the treatment was also acquired. The TPS values at the fiber location were 458.4cGy using TG-43, and 437.6cGy using Acuros-BV calculated as Dm,m (per TG-186). Conclusion: The fiber measured dose value agreement was 3% vs TG-43 and −1% vs Acuros-BV. This fiber detector opens up new possibilities for performing patient-specific quality assurance for Ir-192 HDR GYN procedures. Funding from Coulter Foundation, Duke Bio-medical Engineering. Company is being created around the detector technology. Duke holds patents on the technology.

60 APPLIED LIFE SCIENCES↗

Apparatus and Method for Measuring Strain in Optical Fibers using Rayleigh Scatter

An apparatus and method for measuring strain in an optical fiber using the spectral shift of Rayleigh scattered light. The interference pattern produced by an air gap reflector and backscattered radiation is measured. Using Fourier Transforms, the spectrum of any section of fiber can be extracted. Cross correlation with an unstrained measurement produces a correlation peak. The location of the correlation peak indicates the strain level in the selected portion of optical fiber.

Froggatt, Mark E.↗