Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A mechanical, thermal and electrical packaging design for a prototype power management and control system for the 30 cm mercury ion thruster

A prototype Electric Power Management and Thruster Control System for a 30 cm ion thruster has been built and is ready to support a first mission application. The system meets all of the requirements necessary to operate a thruster in a fully automatic mode. Power input to the system can vary over a full two to one dynamic range (200 to 400 V) for the solar array or other power source. The Power Management and Control system is designed to protect the thruster, the flight system and itself from arcs and is fully compatible with standard spacecraft electronics. The system is designed to be easily integrated into flight systems which can operate over a thermal environment ranging from 0.3 to 5 AU. The complete Power Management and Control system measures 45.7 cm x 15.2 cm x 114.8 cm and weighs 36.2 kg. At full power the overall efficiency of the system is estimated to be 87.4 percent. Three systems are currently being built and a full schedule of environmental and electrical testing is planned.

Sharp, G. R.↗

Ion composition experiment

An investigation using a novel ion mass spectrometer for measuring the ionic composition of the solar wind from the ISEE-C spacecraft is described. The resolution and dynamic range of the instrument are sufficient to be able to resolve up to twelve individual ions or groups of ions. This will permit the solution of a number of fundamental problems related to solar abundances and the formation of the solar wind. The spectrometer is composed of a stigmatic Wien filter and hemispherical electrostatic energy analyzer. The use of curved electric field plates in the filter results in a substantial saving of weight with respect to a conventional filter of the same resolution and angular acceptance. The spectrometer is controlled by a microprocessor based on a special purpose computer which has three modes of operations: full and partial survey modes and a search mode. In the search mode, the instrument locks on to the solar wind. This allows four times the time resolution of the full survey mode and yields a full mass spectrum every 12.6 min.

Coplan, M. A.↗

Some effects of quantization on a noiseless phase-locked loop

If the VCO of a phase-locked receiver is to be replaced by a digitally programmed synthesizer, the phase error signal must be sampled and quantized. Effects of quantizing after the loop filter (frequency quantization) or before (phase error quantization) are investigated. Constant Doppler or Doppler rate noiseless inputs are assumed. The main result gives the phase jitter due to frequency quantization for a Doppler-rate input. By itself, however, frequency quantization is impractical because it makes the loop dynamic range too small.

Greenhall, C. A.↗

Analysis of squaring circuit mechanizations in Costas and squaring loops

The paper discusses implementations of the carrier recovery loop for suppressed carrier binary phase shift keyed signals. The tracking performance of a practical squaring loop where the times-two multiplier is mechanized as a limiter/multiplier combination is developed. This produces the absolute value of the arriving signal which is practical in terms of low signal-to-noise ratios, a wide dynamic range of signal level, and temperature variations. The approach is compared to the usual squaring loop whose squaring circuit is the times-two multiplier exhibiting a square law characteristic.

Lindsey, W. C.↗

Multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are described.

Timothy, J. G.↗

A progress report on multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are briefly described.

Timothy, J. G.↗

On-board data processing for the IRAS telescope system

Onboard data processing has been developed for the Infrared Astronomical Satellite (IRAS) telescope system to effectively utilize the RF bandwidth and minimize the ground-data processing costs. Use of filtering techniques, data deglitching circuits, and data encoding algorithms are combined with a microprocessor-controlled telescope system to achieve a system dynamic range of 100,000 with a noise equivalent flux density of no less than 10 to the minus 19th W/sq cm. Extraneous data, e.g., noise due to radiation hits, will be removed prior to transmission, thereby optimizing ground-data processing for the highest sensitivity and reliability. Simulation results are presented which demonstrate the advantages gained through the use of onboard data processing and illustrate the possible merging of these techniques with an array for the future evolution of 'smart' sensors.

Lum, H.↗

Small mass spectrometer with extended measurement capabilities at high pressures

For the in situ investigation of planetary atmospheres a small Mattauch-Herzog mass spectrometer has been developed. Its high-pressure performance has been improved by incorporating differential pumping between the ion source and the analyzing fields, shortening the path-length as well as increasing the extraction field in the ion source. In addition doubly ionized and dissociated ions are used for mass analysis. These measures make possible operation up to 0.01 millibars. Results of laboratory tests related to linearity, dynamic range, and mass resolution are presented, in particular for CO2.

Von Zahn, U.↗

Electron calibration of instrumentation for low energy, high intensity particle measurements at Mercury

Unique identification of the high intensity, impulsively accelerated charged particle fluxes discovered during Mariner 10's first encounter with Mercury (March 1974) requires a detailed knowledge of the responses of the two University of Chicago charged particle telescopes to low energy fluxes over a wide dynamic range of flux levels. The results of detailed analyses show that these telescopes can separate and identify unambiguously the presence of electron and proton fluxes for a wide range of electron spectra and intensities in the relevant overall range of about 30 keV to 2 MeV.

Christon, S. P.↗

The TIROS-N high resolution infrared radiation sounder

The high-resolution infrared radiation sounder (HIRS/2) was developed and flown on the Television and Infrared Observation Satellite, N Series (TIROS-N) as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow spectral channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel, and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic performance of the instrument in test is described. Early orbital information from the TIROS-N launched on October 13, 1978 are given and some observations on system quality are made.

Koenig, E. W.↗

Microprocessor control for phase-lock receiver

Subsystem facilities flexible data acquisition by combining hardware and software processing. Device controls complex signal acquisition sequence and assists in precise phase locking to received signal. Key features include software system and code-generator initialization routines, executive routine, utility subroutines, control sequence routines for each receiver acquisition state, control-command decoding routine, and look-up tables for code-generator configuration versus code-set number. Steps can be added to extend input signal dynamic range.

Carson, L. M.↗

Low power, compact charge coupled device signal processing system

A variety of charged coupled devices (CCDs) for performing programmable correlation for preprocessing environmental sensor data preparatory to its transmission to the ground were developed. A total of two separate ICs were developed and a third was evaluated. The first IC was a CCD chirp z transform IC capable of performing a 32 point DFT at frequencies to 1 MHz. All on chip circuitry operated as designed with the exception of the limited dynamic range caused by a fixed pattern noise due to interactions between the digital and analog circuits. The second IC developed was a 64 stage CCD analog/analog correlator for performing time domain correlation. Multiplier errors were found to be less than 1 percent at designed signal levels and less than 0.3 percent at the measured smaller levels. A prototype IC for performing time domain correlation was also evaluated.

Bosshart, P. W.↗

Spectroscopy of compact extragalactic X-ray sources

The X-ray spectra of compact extragalactic sources obtained from the HEAO-1 A-2 experiment and the solid-state spectrometer onboard HEAO-2 (the Einstein Observatory) are reviewed. Seyfert spectra are remarkably consistent with characteristic power-law spectra of energy index alpha = 0.7 + .1 over a dynamic range of almost 100 in both luminosity for the whole sample, and energy for individual members. Radio-quiet quasars have similar spectra, perhaps slightly steeper, for the limited sample available. New solid-state spectrometer results for NGC 4151 yield a consistent picture for the geometry of the broad-line clouds in both these related radio-quiet classes of galactic nuclei. Radio-loud objects, especially BL Lacs, are considerably more variable in spectrum as well as luminosity. Direct synchrotron and synchrotron-self-Compton components are consistent with what we observe from these objects. Finally, the role of spectroscopy in addressing the extent to which compact extragalactic nuclei might contribute to the diffuse X-ray background is discussed.

Holt, S. S.↗

Multiwavelength monolithic integrated fiber-optic terminal

The paper presents the Multiwavelength Monolithic Integrated Fiber Optic Terminal (MMIFOT) developed under NASA sponsorship. The program aims to utilize the advantage of optical fiber and integrated optical device technology to achieve parallel transmission of many data channels over the same optical fiber link, and to develop an eight channel wavelength multiplexed fiber optic link that transmits eight bit words in a parallel format at a nominal rate of 20 Mw/s; in the second phase of the program a transmitter/multiplexer chip will be developed. The MMIFOT configuration, the receiver/demultiplexer development, and the waveguide detector development are discussed, concluding that the first phase of the MMIFOT program will culminate in the demonstration of an eight channel receiver/demultiplexer chip with a four channel breadboard multiplexer with the data rate of 20 Mbps per channel with a dynamic range of minimum 20 dB.

Rice, R. R.↗

Charge injection device as a candidate sensor for stellar tracking

Charge transfer devices (CTDs) are superior to the image dissector as stellar tracking sensors, considering their low voltage requirements, insensitivity to magnetic fields, good linearity, and low weight and power. An analysis of one type of CTD, called the charge injection device (CID), revealed an X-Y addressing capability which provides exceptional flexibility in array readout and results in enhanced S/N capability, a surface channel device which produces a larger dynamic range of operation, and exceptional and unique tolerance to optical overloads. A 128 row by 128 column CID array processed on silicon was evaluated in a cooled breadboard camera, and measured results indicate projected performance parameters of a large area CID array as follows: 20 micron square sensing site, noise not greater than 25 carriers per pixel, quantum yield of approximately 40% from 0.4 to 1.0 micron, and cooling requirements on the order of 0 degrees C.

Jones, C. S., Jr.↗

Thermally induced response of flexible structures - A method for analysis

The phenomenon of a thermally induced spacecraft instability became apparent during the flight of the OGO-IV spacecraft in the late 1960s. The paper presents a generalized approach to the problem of obtaining a computationally practical simulation model for a thermally driven structure. The formulation is such that it can be utilized in a stand-along manner or be meshed into a general multibody simulation model such as that reported by Bodley et al. (1978). As presented, the formulation is restricted to the dynamic range for which linearized radiation is a valid assumption.

Frisch, H. P.↗

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.↗

A quadratic analog-to-digital converter

An analog-to-digital converter with a square root transfer function has been developed for use with a pair of CCD imaging detectors in the White Light Coronagraph/X-ray XUV Telescope experiment to be flown as part of the Internal Solar Polar Mission. It is shown that in background-noise-limited instrumentation systems a quadratic analog-to-digital converter will allow a maximum dynamic range with a fixed number of data bits. Low power dissipation, moderately fast conversion time, and reliability are achieved in the proposed design using standard components and avoiding nonlinear elements.

Harrison, D. C.↗