Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Mercuric iodine room temperature gamma-ray detectors

high resolution mercuric iodide room temperature gamma-ray detectors have excellent potential as an essential component of space instruments to be used for high energy astrophysics. Mercuric iodide detectors are being developed both as photodetectors used in combination with scintillation crystals to detect gamma-rays, and as direct gamma-ray detectors. These detectors are highly radiation damage resistant. The list of applications includes gamma-ray burst detection, gamma-ray line astronomy, solar flare studies, and elemental analysis.

Patt, Bradley E.↗

RFI Risk Reduction Activities Using New Goddard Digital Radiometry Capabilities

The Goddard Radio-Frequency Explorer (GREX) is the latest fast-sampling radiometer digital back-end processor that will be used for radiometry and radio-frequency interference (RFI) surveying at Goddard Space Flight Center. The system is compact and deployable, with a mass of about 40 kilograms. It is intended to be flown on aircraft. GREX is compatible with almost any aircraft, including P-3, twin otter, C-23, C-130, G3, and G5 types. At a minimum, the system can function as a clone of the Soil Moisture Active Passive (SMAP) ground-based development unit [1], or can be a completely independent system that is interfaced to any radiometer, provided that frequency shifting to GREX's intermediate frequency is performed prior to sampling. If the radiometer RF is less than 200MHz, then the band can be sampled and acquired directly by the system. A key feature of GREX is its ability to simultaneously sample two polarization channels simultaneously at up to 400MSPS, 14-bit resolution each. The sampled signals can be recorded continuously to a 23 TB solid-state RAID storage array. Data captures can be analyzed offline using the supercomputing facilities at Goddard Space Flight Center. In addition, various Field Programmable Gate Array (FPGA) - amenable radiometer signal processing and RFI detection algorithms can be implemented directly on the GREX system because it includes a high-capacity Xilinx Virtex-5 FPGA prototyping system that is user customizable.

Bradley, Damon↗

Design Enhancements of the Fourier Kelvin Stellar Interferometer to Enable Detection of Earth Twins

During the last few years, considerable effort has been directed towards very large-scale (> $5 billion) missions to detect and characterize Mars-radius to Earth-radius planets around nearby stars; such as the Terrestrial Planet Finder Interferometer and Darwin missions. However, technological issues such as formation flying and control of systematic noise sources will likely prevent these missions from entering Phase A until at least the end of the next decade. Presently more than 350 planets have been discovered by a variety of techniques, and little is known about the majority of them other than their approximate mass. However, a simplified nulling interferometer operating in the near- to mid-infrared (e.g. approx. 5-15 microns), like the enhanced version of the Fourier Kelvin Stellar Interferometer (FKSI), can characterize the atmospheres of a large sample of the known planets - including Earth twins. Many other scientific problems can be addressed with a system like FKSI, including the studies of debris disks, active galactic nuclei, and low mass companions around nearby stars. We report results of a recent engineering study on an enhanced version of FKSI that includes 1-meter primary mirrors, 20-meter boom length, and an advanced sun shield that will provide a 45-degree FOR and 40K operating temperature for all optics including siderostats.

Barry, Richard K.↗

A Search for Butane in Titan’s Atmosphere using Cassini CIRS Infrared Spectra

The atmosphere of Saturn’s moon, Titan, is unlike any other. Photochemistry and ion chemistry in the upper atmosphere process the major atmospheric constituents, molecular nitrogen (N2) and methane (CH4), into larger and more complex molecules including hydrocarbons and nitriles. To date there are ten hydrocarbons heavier than methane that have been detected, including large quantities of the saturated hydrocarbons (alkanes) ethane (C2H6) and propane (C3H8). In addition to being significant trace gases of the atmosphere, these species condense, rain out and add to the volume of Titan’s hydrocarbon lakes and seas. The fourth lightest alkane, butane (C4H10),comes in two structural forms: an unbranched carbon chain (n-butane) and a branched chain (i-butane). The relative production rates of both these isomers are presently unknown, although the circumstantial case for butane to be present in detectable amounts is strong, based on photochemical models and from Cassini low-resolution mass spectrometry of the ionosphere. Butane, like its lighter siblings ethane and propane, is thought to be present in Titan’s lakes and seas where it may be active in forming molecular ‘co-crystals’ with acetylene (C2H2). We report on our recent attempts to detect both forms of butane in Titan’s atmosphere by analysis of Cassini infrared spectra collected during 2004-2017 by the Composite Infrared Spectrometer(CIRS) instrument. This multi-year effort has encompassed the collection of new laboratory spectra of both isomers at several institutions, followed by a concerted attempt to find their signatures in CIRS spectra. We search for butane by high precision modeling and removal of overlying emissions due to other, already-known gases to reveal signatures that match those of the butane isomers. The current status of the search will be discussed, including improved upper limits for both isomers, and directions of future research to detect both species.

Conor Nixon↗

Observation of gamma ray bursts and flares by the EGRET telescope on the Compton Gamma Ray Observatory

The Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory has observed energetic gamma ray bursts and flares. On May 3, 1991, EGRET detected a gamma ray burst both in the energy measuring NaI (Tl) scintillator and independently in the spark chamber imaging assembly. The NaI spectra were accumulated by a special BURST mode of EGRET. The spectra were measured over a range from 1 to 200 MeV, in three sequential spectra of 1,2, and 4 seconds. During the peak of the burst, six individual gamma rays were detected in the spark chamber, allowing a determination of the burst arrival direction. The intense flares of June were also detected. A solar flare on June 4 was observed to last for several minutes and for a brief time, less than a minute, had significant emission of gamma rays exceeding 150 MeV.

Schneid, E. J.↗

Detection of bearing failure in mechanical devices using neural networks

We present a novel time-domain method for the detection of faulty bearings that has direct applicability to monitoring the health of the turbo pumps on the Space Shuttle Main Engine. A feed-forward neural network was trained to detect modelled roller bearing faults on the basis of the periodicity of impact pulse trains. The network's performance was dependent upon the number of pulses in the network's input window and the signal-to-noise ratio of the input signal. To test the model's validity, we fit the model's parameters to an actual vibration signal generated by a faulty roller element bearing and applied the network trained on this model to detect faults in actual vibration data. When this network was tested on the actual vibration data, it correctly identified the vibration signal as a fault condition 76 percent of the time.

Burne, Richard A.↗

Laser Time-of-Flight Mass Spectrometry for Future In Situ Planetary Missions

Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) is a versatile, low-complexity instrument class that holds significant promise for future landed in situ planetary missions that emphasize compositional analysis of surface materials. Here we describe a 5kg-class instrument that is capable of detecting and analyzing a variety of analytes directly from rock or ice samples. Through laboratory studies of a suite of representative samples, we show that detection and analysis of key mineral composition, small organics, and particularly, higher molecular weight organics are well suited to this instrument design. A mass range exceeding 100,000 Da has recently been demonstrated. We describe recent efforts in instrument prototype development and future directions that will enhance our analytical capabilities targeting organic mixtures on primitive and icy bodies. We present results on a series of standards, simulated mixtures, and meteoritic samples.

Getty, S. A.↗

Photometric and CCD direct image observation of comet Encke

Attempted detection of periodic variations in brightness of the comet Encke is described. Viewing problems due to the position, faintness, and rate of motion of the comet are discussed. The failure of attempts to perform photoelectric photometry and CCD imaging is described. Photometric observations of the prototype Earth crosser, (1862) Apollo, are described and a photoelectric light curve of observations made during a four-hour period is presented.

Mccrosky, R. E.↗

Stellar Bragg crystal X-ray spectrometry on OSO-1

A high sensitivity crystal X-ray spectrometer for use on the Orbiting Solar Observatory (mission 1) satellite is described. This instrument will be used to obtain both solar and stellar spectra in the energy range 2 to 8 keV. In the stellar mode, the shape of the continua, the strength of lines, and the strength of recombination and absorption edge were determined. If lines or edges are detected, such data will provide direct evidence regarding the physical conditions in the emitting and absorbing regions. If only upper bounds are established, the data can be used to constrain theoretical models. In any case, precise continuum shapes will be established for a number of the brighter X-ray sources. Numerical estimates of the sensitivity of the instrument for these various purposes are given.

Landecker, P. B.↗

Decision-directed detector for overlapping PCM/NRZ signals.

A decision-directed (DD) technique for the detection of overlapping PCM/NRZ signals in the presence of white Gaussian noise is investigated. The performance of the DD detector is represented by probability of error Pe versus input signal-to-noise ratio (SNR). To examine how much improvement in performance can be achieved with this technique, Pe's with and without DD feedback are evaluated in parallel. Further, analytical results are compared with those found by Monte Carlo simulations. The results are in good agreement.

Wang, C. D.↗

A flash photolysis-resonance fluorescence study of the formation of O(D-1) in the photolysis of water and reaction of O(D-1) with H2, Ar and He

The relative importance of two primary processes in the photolyis of water: (1) H2O + h (nu) yields H + OH, and (2) H2O + h (nu) yields H2 + OD-1 were determined in a direct manner by time resolved detection (via resonance fluorescence) of H and O formed in processes 1 and 2 respectively. The initially formed OD-1 was deactivated to ground state OP-3 prior to detection via resonance fluorescence. The relative quantum yields for processes 1 and 2 are 0.89 and 0.11 for the wavelength interval 105 to 145nm and = to or greater than 0.99, and = to or less than 0.01 for the wavelength interval 145 to 185nm. Rate constants at 300 K for the reactions OD-1 + H2, + Ar, and + He are presented.

Stief, L. J.↗

Effluent sampling of Titan 3 C vehicle exhaust

Downwind in situ ground-level measurements of the exhaust from a Titan 3 C launch vehicle were made during a normal launch. The measurement activity was conducted as part of an overall program to obtain field data for comparison with the multilayer dispersion model currently being used to predict the behavior of rocket vehicle exhaust clouds. All measurements were confined to land, ranging from the launch pad to approximately 2 kilometers downwind from the pad. Measurement systems included detectors for hydrogen chloride (HCl), carbon dioxide (CO2), and particulates (Al2O3). Airborne and ground-based optical systems were employed to monitor exhaust cloud rise, growth, and movement. These measurement systems, located along the ground track (45 deg azimuth from the launch pad) of the exhaust cloud, showed no effluents attributable to the launch. Some hydrogen chloride and aluminum oxide were detected in the surface wind direction (15 deg azimuth) from the pad. Comparisons with the model were made in three areas: (1) assumption of cloud geometry at stabilization; (2) prediction of cloud stabilization altitude; and (3) prediction of the path of cloud travel. In addition, the importance of elemental analyses of the particulate samples is illustrated.

Gregory, G. L.↗

Shadow mask for X-ray spectrometer

Imaging technique may be used in series with flat or conical Bragg crystals to separate spatial/spectral convolution when spectrometer is scanned across extended source emitting at more than one wavelength. Technique allows line direction and continuum to be detected and provides data for spatial mapping of source.

Woodgate, B. E.↗

Acceleration of H, He, and heavy ions observed in the magnetosheath, magnetotail, and near-by interplanetary space

Pulses of electrons and ions composed of H, He, and heavier elements were observed in the magnetosheath, magnetotail, and near-by interplanetary space. From the spatial positions where these particles were detected and the ion flow directions, it is concluded that they were accelerated at the bow shock near the sub-solar point and in the near-earth region of the neutral sheet of the magnetotail.

Fan, C. Y.↗

Polymers in solar energy utilization

A laser photoacoustic technique (LPAT) has been verified for performing accelerated life testing of outdoor photooxidation of polymeric materials used in solar energy applications. Samples of the material under test are placed in a chamber with a sensitive microphone, then exposed to chopped laser radiation. The sample absorbs the light and converts it to heat by a nonradiative deexcitation process, thereby reducing pressure fluctuations within the cell. The acoustic signal detected by the microphone is directly proportional to the amount of light absorbed by the specimen. Tests were performed with samples of ethylene/methylacrylate copolymer (EMA) reprecipitated from hot cyclohexane, compressed, and molded into thin (25-50 microns) films. The films were exposed outdoors and sampled by LPAT weekly. The linearity of the light absorbed with respect to the acoustic signal was verified.Correlations were established between the photoacoustic behavior of the materials aged outdoors and the same kinds of samples cooled and heated in a controlled environment reactor. The reactor tests were validated for predicting outdoor exosures up to 55 days.

Liang, R. H.↗

Timing performance of phased-locked loops in optical pulse position modulation communication systems

An optical digital communication system requires that an accurate clock signal be available at the receiver for proper synchronization with the transmitted signal. Phase synchronization is especially critical in M-ary pulse position modulation (PPM) systems where the optimum decision scheme is an energy detector which compares the energy in each of M time slots to decide which of M possible words was sent. Timing errors cause energy spillover into adjacent time slots (a form of intersymbol interference) so that only a portion of the signal energy may be attributed to the correct time slot. This effect decreases the effective signal, increases the effective noise, and increases the probability of error. A timing subsystem for a satellite-to-satellite optical PPM communication link is simulated. The receiver employs direct photodetection, preprocessing of the detected signal, and a phase-locked loop for timing synchronization. The variance of the relative phase error is examined under varying signal strength conditions as an indication of loop performance, and simulation results are compared to theoretical calculations.

Lafaw, D. A.↗