Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

The Wendelstein 7-X phase contrast imaging diagnostic

We report a phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. The PCI diagnostic provides a line-integrated measurement of turbulent electron density fluctuations, which is essential for understanding high performance scenarios that can lead to improved confinement at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, which arise from Alfvén eigenmodes or other MHD activity. This paper provides an overview of the hardware and the optical system and presents an example PCI measurement from the W7-X OP1.2b experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated assessment model diagnostics: key indicators and model evolution

Integrated assessment models (IAMs) form a prime tool in informing climate mitigation strategies. Diagnostic indicators that allow to compare these models can help to describe and explain differences in model projections. This also increases transparency and comparability. Earlier, the IAM community has developed an approach to diagnose models (Kriegler et al., 2015). Here we build on this, by proposing a selected set of well-defined indicators as a community standard, similar to metrics used for other modeling communities such as climate models. These indicators are the relative abatement index (RAI), emission reduction type index (ERT), inertia timescale (IT), fossil fuel reduction (FFR), transformation index (TI) and cost per abatement value (CAV). We apply the approach to 17 IAMs, including both older version as well as their latest versions, as applied in the IPCC 6th Assessment Report (AR6). The study shows that the approach can be easily applied and allows for comparison of model versions in time. The indicators and their trends can often be explained in terms of model characteristics and changes. We show that together, the set of six indicators can provide an useful indication of the main traits of the model and can roughly indicate the general model behavior. The results also show that there is often a considerable spread across the models. Interestingly, the diagnostic values often change for different model versions, but there does not seem to be a distinct trend across the different models.

54 ENVIRONMENTAL SCIENCES↗

SOLAR TRANSITION REGION LINES OBSERVED BY THE INTERFACE REGION IMAGING SPECTROGRAPH: DIAGNOSTICS FOR THE O IV AND Si IV LINES

The formation of the transition region O IV and Si IV lines observable by the Interface Region Imaging Spectrograph (IRIS) is investigated for both Maxwellian and non-Maxwellian conditions characterized by a κ-distribution exhibiting a high-energy tail. The Si IV lines are formed at lower temperatures than the O IV lines for all κ. In non-Maxwellian situations with lower κ, the contribution functions are shifted to lower temperatures. Combined with the slope of the differential emission measure, it is possible for the Si IV lines to be formed at very different regions of the solar transition region than the O IV lines; possibly close to the solar chromosphere. Such situations might be discernible by IRIS. It is found that photoexcitation can be important for the Si IV lines, but is negligible for the O IV lines. The usefulness of the O IV ratios for density diagnostics independently of κ is investigated and it is found that the O IV 1404.78 Å/1399.77 Å ratio provides a good density diagnostics except for very low T combined with extreme non-Maxwellian situations.

79 ASTRONOMY AND ASTROPHYSICS↗

SPITZER IRAC COLOR DIAGNOSTICS FOR EXTENDED EMISSION IN STAR-FORMING REGIONS

The infrared data from the Spitzer Space Telescope are an invaluable tool for identifying physical processes in star formation. In this study, we calculate the Infrared Array Camera (IRAC) color space of UV fluorescent H{sub 2} and polycyclic aromatic hydrocarbon (PAH) emission in photodissociation regions (PDRs) using the Cloudy code with PAH opacities from Draine and Li. We create a set of color diagnostics that can be applied to study the structure of PDRs and to distinguish between FUV-excited and shock-excited H{sub 2} emission. To test this method, we apply these diagnostics to Spitzer IRAC data of NGC 2316. Our analysis of the structure of the PDR is consistent with previous studies of the region. In addition to UV excited emission, we identify shocked gas that may be part of an outflow originating from the cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Line identification of boron and nitrogen emissions in EUV and VUV wavelength ranges in the impurity powder dropping experiments of LHD and its application to spectroscopic diagnostics

An impurity powder dropper was installed in the 21st campaign of the Large Helical Device experiment (Oct. 2019–Feb. 2020) under a collaboration between the National Institute for Fusion Science and the Princeton Plasma Physics Laboratory for the purposes of real-time wall conditioning and edge plasma control. In order to assess the effective injection of the impurity powders, spectroscopic diagnostics were applied to observe line emission from the injected impurity. Therefore, extreme-ultraviolet (EUV) and vacuum-ultraviolet (VUV) emission spectra were analyzed to summarize observable impurity lines with B and BN powder injection. Emission lines released from B and N ions were identified in the EUV wavelength range of 5–300 Å measured using two grazing incidence flat-field EUV spectrometers and in the VUV wavelength range of 300–2400 Å measured using three normal incidence 20 cm VUV spectrometers. BI–BV and NIII–NVII emission lines were identified in the discharges with the B and BN powder injection, respectively. Useful B and N emission lines which have large intensities and are isolated from other lines were successfully identified as follows: BI (1825.89, 1826.40) Å (blended), BII 1362.46 Å, BIII (677.00, 677.14, 677.16) Å (blended), BIV 60.31 Å, BV 48.59 Å, NIII (989.79, 991.51, 991.58) Å (blended), NIV 765.15 Å, NV (209.27, 209.31) Å (blended), NVI 1896.80 Å, and NVII 24.78 Å. Applications of the line identifications to the advanced spectroscopic diagnostics were demonstrated, such as the vertical profile measurements for the BV and NVII lines using a space-resolved EUV spectrometer and the ion temperature measurement for the BII line using a normal incidence 3 m VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microscale and Nanoscale Electrophotonic Diagnostic Devices

Detecting and identifying infectious agents and potential pathogens in complex environments and characterizing their mode of action is a critical need. Traditional diagnostics have targeted a single characteristic, e.g. spectral response, surface receptor, mass, intrinsic conductivity, etc. However, advances in detection technologies have identified emerging approaches in which multiple modes of action are combined to obtain enhanced performance characteristics. Particularly appealing in this regard, electrophotonic devices capable of coupling light to electron translocation have experienced rapid recent growth and offer significant advantages for diagnostics. In this chapter, we explore three specific promising approaches that combine electronics and photonics: (a) assays based on closed bipolar electrochemistry coupling electron transfer to color or fluorescence (b) sensors based on localized surface plasmon resonances, and (c) emerging nanophotonics approaches, such as those based on zero-mode waveguides and metamaterials.

60 APPLIED LIFE SCIENCES↗

Demonstration of x-ray fluorescence spectroscopy as a sensitive temperature diagnostic for high-energy-density physics experiments

We present the use of x-ray fluorescence spectroscopy (XFS) to a sensitive temperature diagnostic in shocked foams at temperatures of 30–75 eV. Cobalt-doped foams were shock compressed using a planar drive at the OMEGA laser facility and photo-pumped with a Zn He⁢𝛼 x-ray source. Analysis of the resulting cobalt 𝐾⁢𝛽 x-ray fluorescence spectra using collisional radiative codes allows the temperature to be determined in the shocked foams. Furthermore, this method provides a sensitive and robust technique to determine temperatures in high-energy-density physics experiments in the tens of electronvolts temperature range. In these experiments, we find that radiation hydrodynamic simulations predict a lower temperature in the shocked foams compared to analysis of the XFS data using collisional radiative models. Although additional experiments with an independent temperature diagnostic to absolutely calibrate XFS spectra for these conditions will be required to resolve this discrepancy, these results demonstrate the excellent temperature sensitivity of XFS spectra for high-energy-density physics experiments.

Atomic spectra↗

Dirac $R$-matrix calculations for the electron-impact excitation of neutral tungsten providing noninvasive diagnostics for magnetic confinement fusion

Neutral tungsten is the primary candidate as a wall material in the divertor region of the International Thermonuclear Experimental Reactor (ITER). The efficient operation of ITER depends heavily on precise atomic physics calculations for the determination of reliable erosion diagnostics, helping to characterize the influx of tungsten impurities into the core plasma. The following paper presents detailed calculations of the atomic structure of neutral tungsten using the multiconfigurational Dirac-Fock method, drawing comparisons with experimental measurements where available, and includes a critical assessment of existing atomic structure data. We investigate the electron-impact excitation of neutral tungsten using the Dirac R-matrix method, and by employing collisional-radiative models, we benchmark our results with recent Compact Toroidal Hybrid measurements. The resulting comparisons highlight alternative diagnostic lines to the widely used 400.88-nm line.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Diagnostics, Control and Performance Parameters for the BELLA High Repetition Rate Petawatt Class Laser

A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This study discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. The spatial profile was measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9 . The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. Finally, the capabilities described in this paper are essential for generation of high quality electron beams.

47 OTHER INSTRUMENTATION↗

PANDA-FES: Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science

Nuclear fusion is a potential source of carbon-free electricity with many concepts in development. The Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science (PANDA-FES) suite has been deployed since 2021 to measure neutron yield, energy, and spatiotemporal source location at two different Z-pinch fusion devices. This diagnostic can be used at a variety of facilities pursuing fusion in the magnetic, inertial, and magneto-inertial regimes. These different regimes have a wide range of time scales from less than 100 ns to a few μ s, neutron yields from 10 6 to 10 11 , and noise environments. Neutron yield is measured through activation of 79 Br and 89 Y with calibrated detectors. Temporal, spatial, and energy dependence of neutrons is measured with scintillators coupled to photomultiplier tubes (PMTs). Experimental setups and data analysis methods have been developed for these conditions. Finally, neutron yield, neutron energy anisotropy, and spatiotemporal evolution of the source have been measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pleural homocysteine for malignant pleural effusion: A prospective and double‐blind diagnostic test accuracy study

Abstract Objective To assess the accuracy of pleural fluid homocysteine for discriminating malignant pleural effusion (MPE) and benign pleural effusion (BPE). Methods A total of 194 patients from two cohorts (Hohhot and Changshu) with undiagnosed pleural effusion were prospectively enrolled. Their pleural homocysteine was measured, and its diagnostic accuracy and net benefit for MPE were analyzed by receiver operating characteristic (ROC) curve analysis and decision curve analysis, respectively. Results In the Hohhot cohort ( n = 136) and the Changshu cohort ( n = 58), MPE patients had significantly higher homocysteine levels than BPE patients. The areas under the ROC curves of homocysteine for the diagnosis of MPE were 0.61 ( p = 0.027) and 0.59 ( p = 0.247), respectively. The decision curves of homocysteine were close to the reference line in both the Hohhot cohort and the Changshu cohort. Conclusion The diagnostic accuracy of pleural fluid homocysteine for MPE was low.

Cao, Xi‐Shan↗

Rayleigh-Taylor Instability: A Status Review of Experimental Designs and Measurement Diagnostics

The focus of experiments and the sophistication of diagnostics employed in Rayleigh-Taylor instability (RTI) induced mixing studies have evolved considerably over the past seven decades. The first theoretical analysis by Taylor and the two-dimensional experimental results by Lewis on RTI in 1950 examined single-mode RTI using conventional imaging techniques. Over the next 70 years, several experimental designs have been used to creating an RTI unstable interface between two materials of different densities. These early experiments though innovative, were arduous to diagnose and provided little information on the internal, turbulent structure and initial conditions of the RT mixing layer. Coupled with the availability of high-fidelity diagnostics, the experiments designed and developed in the last three decades allow detailed measurements of various turbulence statistics that have allowed broadly to validate and verify late-time nonlinear models and mix-models for buoyancy-driven flows. Besides, they have provided valuable insights to solve several long-standing disagreements in the field. Herein, this review serves as an opportunity to discuss the understanding of the RTI problem and highlight valuable insights gained into the RTI driven mixing process with a focus on low to high Atwood number (> 0.1) experiments.

42 ENGINEERING↗

SU-E-I-65: The Joint Commission's Requirements for Annual Diagnostic Physics Testing of Nuclear Medicine Equipment, and a Clinically Relevant Methodology for Testing Low-Contrast Resolution

Purpose: To introduce the Joint Commission's requirements for annual diagnostic physics testing of all nuclear medicine equipment, effective 7/1/2014, and to highlight an acceptable methodology for testing lowcontrast resolution of the nuclear medicine imaging system. Methods: The Joint Commission's required diagnostic physics evaluations are to be conducted for all of the image types produced clinically by each scanner. Other accrediting bodies, such as the ACR and the IAC, have similar imaging metrics, but do not emphasize testing low-contrast resolution as it relates clinically. The proposed method for testing low contrast resolution introduces quantitative metrics that are clinically relevant. The acquisition protocol and calculation of contrast levels will utilize a modified version of the protocol defined in AAPM Report #52. Results: Using the Rose criterion for lesion detection with a SNRpixel = 4.335 and a CNRlesion = 4, the minimum contrast levels for 25.4 mm and 31.8 mm cold spheres were calculated to be 0.317 and 0.283, respectively. These contrast levels are the minimum threshold that must be attained to guard against false positive lesion detection. Conclusion: Low contrast resolution, or detectability, can be properly tested in a manner that is clinically relevant by measuring the contrast level of cold spheres within a Jaszczak phantom using pixel values within ROI's placed in the background and cold sphere regions. The measured contrast levels are then compared to a minimum threshold calculated using the Rose criterion and a CNRlesion = 4. The measured contrast levels must either meet or exceed this minimum threshold to prove acceptable lesion detectability. This research and development activity was performed by the authors while employed at West Physics Consulting, LLC. It is presented with the consent of West Physics, which has authorized the dissemination of the information and/or techniques described in the work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Nanometric organic photovoltaic thin film detectors for dose monitoring in diagnostic x-ray imaging

Purpose: To fabricate organic photovoltaic (OPV) cells with nanometric active layers sensitive to ionizing radiation and measure their dosimetric characteristics in clinical x-ray beams in the diagnostic tube potential range of 60–150 kVp. Methods: Experiments were designed to optimize the detector’s x-ray response and find the best parameter combination by changing the active layer thickness and the area of the electrode. The OPV cell consisted of poly (3-hexylthiophene-2,5-diyl): [6,6]-phenyl C{sub 61} butyric acid methyl ester photoactive donor and acceptor semiconducting organic materials sandwiched between an aluminum electrode as an anode and an indium tin oxide electrode as a cathode. The authors measured the radiation-induced electric current at zero bias voltage in all fabricated OPV cells. Results: The net OPV current as a function of beam potential (kVp) was proportional to kVp{sup −0.5} when normalized to x-ray tube output, which varies with kVp. Of the tested configurations, the best combination of parameters was 270 nm active layer thicknesses with 0.7 cm{sup 2} electrode area, which provided the highest signal per electrode area. For this cell, the measured current ranged from approximately 0.7 to 2.4 nA/cm{sup 2} for 60–150 kVp, corresponding to about 0.09 nA–0.06 nA/mGy air kerma, respectively. When compared to commercial amorphous silicon thin film photovoltaic cells irradiated under the same conditions, this represents 2.5 times greater sensitivity. An additional 40% signal enhancement was observed when a 1 mm layer of plastic scintillator was attached to the cells’ beam-facing side. Conclusions: Since both OPVs can be produced as flexible devices and they do not require external bias voltage, they open the possibility for use as thin film in vivo detectors for dose monitoring in diagnostic x-ray imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the local diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.

60 APPLIED LIFE SCIENCES↗

SU-E-I-06: A Dose Calculation Algorithm for KV Diagnostic Imaging Beams by Empirical Modeling

Purpose: To develop accurate three-dimensional (3D) empirical dose calculation model for kV diagnostic beams for different radiographic and CT imaging techniques. Methods: Dose was modeled using photon attenuation measured using depth dose (DD), scatter radiation of the source and medium, and off-axis ratio (OAR) profiles. Measurements were performed using single-diode in water and a diode-array detector (MapCHECK2) with kV on-board imagers (OBI) integrated with Varian TrueBeam and Trilogy linacs. The dose parameters were measured for three energies: 80, 100, and 125 kVp with and without bowtie filters using field sizes 1×1–40×40 cm2 and depths 0–20 cm in water tank. Results: The measured DD decreased with depth in water because of photon attenuation, while it increased with field size due to increased scatter radiation from medium. DD curves varied with energy and filters where they increased with higher energies and beam hardening from half-fan and full-fan bowtie filters. Scatter radiation factors increased with field sizes and higher energies. The OAR was with 3% for beam profiles within the flat dose regions. The heal effect of this kV OBI system was within 6% from the central axis value at different depths. The presence of bowtie filters attenuated measured dose off-axis by as much as 80% at the edges of large beams. The model dose predictions were verified with measured doses using single point diode and ionization chamber or two-dimensional diode-array detectors inserted in solid water phantoms. Conclusion: This empirical model enables fast and accurate 3D dose calculation in water within 5% in regions with near charge-particle equilibrium conditions outside buildup region and penumbra. It considers accurately scatter radiation contribution in water which is superior to air-kerma or CTDI dose measurements used usually in dose calculation for diagnostic imaging beams. Considering heterogeneity corrections in this model will enable patient specific dose calculation.

60 APPLIED LIFE SCIENCES↗

SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrix was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.

60 APPLIED LIFE SCIENCES↗