Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detect And Avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

NORM Concentration Determination in Common Materials in an Urban Environment

The United States government performs searches for illicit radiation sources before and during large special events, such as State of the Union addresses, presidential inaugurations, or the recent papal visit. Clear detection of sources is difficult due to natural background radiation, which can vary greatly throughout a given search area. Background radiation is mostly a function of the materials used in roadways, sidewalks, and building exteriors. A team of scientists from Oak Ridge National Laboratory (ORNL), Lawrence Livermore National Laboratory (LLNL), the Remote Sensing Laboratory (RSL), and Lawrence Berkeley National Laboratory (LBNL) is exploring the nature and variability of background count rates in order to improve the performance of searches in urban areas. A series of background measurements have been and will continue to be taken at a Military Operations on Urban Terrain (MOUT) environment at the Fort Indiantown Gap (FTIG) National Guard training facility in Pennsylvania. This site replicates a small town with asphalt roads, concrete intersections, buildings, sidewalks, curbs, and gravel parking areas. Unlike an actual urban area, traffic and pedestrian access can be easily controlled to avoid interference with measurements. This paper documents the efforts focused on characterizing the various concentrations of radioactive material found in these materials at the site. The NORM concentrations determined from this work will be incorporated in to a large-scale simulation (a 'virtual test-bed') that can be used to investigate various search techniques and algorithms, detector suite configurations, and to produce representative synthetic data for future work. A combination of measurement and simulation was used to determine the concentration of {sup 40}K and the radioactive nuclides in the uranium series and the thorium series in several materials at the FTIG MOUT site. The predicted concentrations are consistent with other published results, and they matched favorably with synthetic data generated with MCNP6 models using the determined NORM concentrations and estimates of the FTIG environment as described by available construction plans and using standard material assumptions. Future measurements will incorporate lessons learned from this study. More measurements will be made of the concrete intersections at the site. The methodology explained in this report will also be carried out on building materials in an effort to characterize NORM concentrations in these background sources. Other modeling and simulation work that should be conducted includes a robust sensitivity analysis in which the effects of small changes to the model (and measurement) system can be characterized to help bound the uncertainty on the final NORM concentration predictions. (authors)

54 ENVIRONMENTAL SCIENCES↗

Noise robust detection of quantum phase transitions

Quantum computing allows for the manipulation of highly correlated states whose properties quickly go beyond the capacity of any classical method to calculate. Thus one natural problem which could lend itself to quantum advantage is the study of ground-states of condensed matter models, and the transitions between them. However, current levels of hardware noise can require extensive application of error-mitigation techniques to achieve reliable computations. In this work, we use several IBM devices to explore a finite-size spin model with multiple “phaselike” regions characterized by distinct ground-state configurations. Using preoptimized Variational Quantum Eigensolver (VQE) solutions, we demonstrate that in contrast to calculating the energy, where zero-noise extrapolation is required in order to obtain qualitatively accurate yet still unreliable results, calculations of the energy derivative, two-site spin correlation functions, and the fidelity susceptibility yield accurate behavior across multiple regions, even with minimal or no application of error-mitigation approaches. Taken together, these sets of observables could be used to identify level crossings in a simple, noise-robust manner which is agnostic to the method of ground state preparation. This work shows promising potential for near-term application to identifying quantum phase transitions, including avoided crossings and nonadiabatic conical intersections in electronic structure calculations. Published by the American Physical Society 2024

Lively, Kevin (ORCID:0000000320981494)↗

Design and development of Gamma-ray Burst Monitor for the CALET Mission

We propose to provide a gamma-ray burst monitor (GBM) for the CALET mission to monitor gamma-ray bursts (GRBs) together with the CALET Imaging Calorimeter detector. The major purpose is to derive a wide-band energy spectrum of GRBs over an unprecedented 9 decades of energy (from a few keV to a few TeV) in combination with the CALET tower detector. Hence it is desirable to have the CALET-GBM covering an energy range from a few keV to about 20 MeV to avoid a gap in the observational energy bands. The design of GBM is underway to fulfill this requirement. The current detector candidate is BGO, and a LaBr (Ce) scintillator which has a superior energy resolution to that of NaI(Tl). In this paper, design and expected performance of the CALET-GBM is shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TEMPERATURE MONITORING OPTIONS AVAILABLE AT THE IDAHO NATIONAL LABORATORY ADVANCED TEST REACTOR

As part of the Advanced Test Reactor National Scientific User Facility (ATR NSUF) program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced sensors for irradiation testing. To meet recent customer requests, an array of temperature monitoring options is now available to ATR users. The method selected is determined by test requirements and budget. Melt wires are the simplest and least expensive option for monitoring temperature. INL has recently verified the melting temperature of a collection of materials with melt temperatures ranging from 100 to 1000 C with a differential scanning calorimeter installed at INL’s High Temperature Test Laboratory (HTTL). INL encapsulates these melt wires in quartz or metal tubes. In the case of quartz tubes, multiple wires can be encapsulated in a single 1.6 mm diameter tube. The second option available to ATR users is a silicon carbide temperature monitor. The benefit of this option is that a single small monitor (typically 1 mm x 1 mm x 10 mm or 1 mm diameter x 10 mm length) can be used to detect peak irradiation temperatures ranging from 200 to 800 C. Equipment has been installed at INL’s HTTL to complete post-irradiation resistivity measurements on SiC monitors, a technique that has been found to yield the most accurate temperatures from these monitors. For instrumented tests, thermocouples may be used. In addition to Type-K and Type-N thermocouples, a High Temperature Irradiation Resistant ThermoCouple (HTIR-TC) was developed at the HTTL that contains commercially-available doped molybdenum paired with a niobium alloy thermoelements. Long duration high temperature tests, in furnaces and in the ATR and other MTRs, demonstrate that the HTIR-TC is accurate up to 1800 C and insensitive to thermal neutron interactions. Thus, degradation observed at temperatures above 1100 C with Type K and N thermocouples and decalibration due to transmutation with tungsten-rhenium and platinum rhodium thermocouples can be avoided. INL is also developing an Ultrasonic Thermometry (UT) capability. In addition to small size, UT’s offer several potential advantages over other temperature sensors. Measurements may be made near the melting point of the sensor material, potentially allowing monitoring of temperatures up to 3000 C. In addition, because no electrical insulation is required, shunting effects are avoided. Most attractive, however, is the ability to introduce acoustic discontinuities to the sensor, as this enables temperature measurements at several points along the sensor length. As discussed in this paper, the suite of temperature monitors offered by INL is not only available to ATR users, but also to users at other MTRs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distribution Atlas of Proliferating Bone Marrow in Non-Small Cell Lung Cancer Patients Measured by FLT-PET/CT Imaging, With Potential Applicability in Radiation Therapy Planning

Purpose: Proliferating bone marrow is exquisitely sensitive to ionizing radiation. Knowledge of its distribution could improve radiation therapy planning to minimize unnecessary marrow exposure and avoid consequential prolonged myelosuppression. [18F]-Fluoro-3-deoxy-3-L-fluorothymidine (FLT)–positron emission tomography (PET) is a novel imaging modality that provides detailed quantitative images of proliferating tissues, including bone marrow. We used FLT-PET imaging in cancer patients to produce an atlas of marrow distribution with potential clinical utility. Methods and Materials: The FLT-PET and fused CT scans of eligible patients with non-small cell lung cancer (no distant metastases, no prior cytotoxic exposure, no hematologic disorders) were reviewed. The proportions of skeletal FLT activity in 10 predefined bony regions were determined and compared according to age, sex, and recent smoking status. Results: Fifty-one patients were studied: 67% male; median age 68 (range, 31-87) years; 8% never smokers; 70% no smoking in the preceding 3 months. Significant differences in marrow distribution occurred between sex and age groups. No effect was detected from smoking in the preceding 3 months. Using the mean percentages of FLT uptake per body region, we created an atlas of the distribution of functional bone marrow in 4 subgroups defined by sex and age. Conclusions: This atlas has potential utility for estimating the distribution of active marrow in adult cancer patients to guide radiation therapy planning. However, because of interindividual variation it should be used with caution when radiation therapy risks ablating large proportions of active marrow; in such cases, individual FLT-PET scans may be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of atmospheric parameters on radon measurements using alpha-track detectors

The calibration factors of alpha-track radon detectors (ATDs) are essential for accurate determination of indoor radon concentrations. In this paper, the effects of atmospheric parameters on the calibration factors were theoretically studied and partially testified. Based on the atmospheric thermodynamics theory and detection characteristics of the allyl diglycol carbonate (CR-39), the calibration factors for 5 types of ATDs were calculated through Monte Carlo simulations under different atmospheric conditions. Simulation results showed that the calibration factor increased by up to 31% for the ATDs with a decrease of air pressure by 35.5 kPa (equivalent to an altitude increase of 3500 m), and it also increased by up to 12% with a temperature increase from 5 °C to 35 °C, but it was hardly affected by the relative humidity unless the water-vapor condensation occurs inside the detectors. Furthermore, it was also found that the effects on calibration factors also depended on the dimensions of ATDs. It indicated that variations of the calibration factor with air pressure and temperature should be considered for an accurate radon measurement with a large dimensional ATD, and water-vapor condensation inside the detector should be avoided in field measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

DELAYED ONSET OF HIGH-ENERGY EMISSIONS IN LEPTONIC AND HADRONIC MODELS OF GAMMA-RAY BURSTS

The temporal-spectral evolution of the prompt emission of gamma-ray bursts is simulated numerically for both leptonic and hadronic models. For weak enough magnetic fields, leptonic models can reproduce the few seconds delay of the onset of GeV photon emission observed by Fermi-LAT, due to the slow growth of the target photon field for inverse Compton scattering. For stronger magnetic fields, the GeV delay can be explained with hadronic models, due to the long acceleration timescale of protons and the continuous photopion production after the end of the particle injection. While the FWHMs of the MeV and GeV light curves are almost the same in one-zone leptonic models, the FWHMs of the 1-30 GeV light curves in hadronic models are significantly wider than those of the 0.1-1 MeV light curves. The amount of the GeV delay depends on the importance of the Klein-Nishina effect in both the leptonic and hadronic models. In our examples of hadronic models the energies of the escaped neutrons are comparable to the gamma-ray energy, although their contribution to the ultra high-energy cosmic rays is still subdominant. The resulting neutrino spectra are hard enough to avoid the flux limit constraint from IceCube. The delay of the neutrino emission onset is up to several times longer than the corresponding delay of the GeV photon emission onset. The quantitative differences in the light curves for various models may be further tested with future atmospheric Cerenkov telescopes whose effective area is larger than that of Fermi-LAT, such as CTA.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging Fluorescence-Correlation Spectroscopy for Measuring Fast Surface Diffusion at Liquid/Solid Interfaces

The development of techniques to probe interfacial molecular transport is important for understanding and optimizing surface-based analytical methods including surface-enhanced spectroscopies, biological assays, and chemical separations. Single-molecule-fluorescence imaging and tracking has been used to measure lateral diffusion rates of fluorescent molecules at surfaces, but the technique is limited to the study of slower diffusion, where molecules must remain relatively stationary during acquisition of an image in order to build up sufficient intensity in a spot to detect and localize the molecule. Although faster time resolution can be achieved by fluorescence-correlation spectroscopy (FCS), where intensity fluctuations in a small spot are related to the motions of molecules on the surface, long-lived adsorption events arising from surface inhomogeneity can overwhelm the correlation measurement and mask the surface diffusion of the moving population. Here, we exploit a combination of these two techniques, imaging-FCS, for measurement of fast interfacial transport at a model chromatographic surface. This is accomplished by rapid imaging of the surface using an electron-multiplied-charged-coupled-device (CCD) camera, while limiting the acquisition to a small area on the camera to allow fast framing rates. The total intensity from the sampled region is autocorrelated to determine surface diffusion rates of molecules with millisecond time resolution. Here, the technique allows electronic control over the acquisition region, which can be used to avoid strong adsorption sites and thus minimize their contribution to the measured autocorrelation decay and to vary the acquisition area to resolve surface diffusion from adsorption and desorption kinetics. As proof of concept, imaging-FCS was used to measure surface diffusion rates, interfacial populations, and adsorption–desorption rates of 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine (DiI) on planar C18- and C1-modified surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Advanced Safeguards Technology Demonstration at Pacific Northwest National Laboratory

The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-grade nuclear material are not diverted over a specified time frame. Currently, methods to verify that the facilities are operating under adequate safeguard-declared conditions require time consuming sampling and expensive, destructive analysis. The time delay between sampling and subsequent analysis provides a potential opportunity to divert the material out of the appropriate chemical stream. One way to avoid this problem is to use process monitoring equipment that is capable of on-line and in near-real time monitoring of the flowsheet radiochemical streams to rapidly identify deviations from normal operating conditions. Three integrated systems for flowsheet monitoring are currently being developed at PNNL including: 1) Multi-Isotope Process Monitor (MIP), 2) a spectroscopy-based monitor utilizing UV-Vis-NIR (Ultra Violet-Visible-Near Infrared) and Raman spectrometers, and 3) Electrochemically Modulated Separations (EMS). MIP uses gamma spectroscopy and pattern recognition software to identify off-normal conditions in process streams. The UV-Vis-NIR and Raman spectroscopic monitoring continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major cold flowsheet chemicals. EMS provides an on-line means for pre-separating and preconcentrating elements of interest out of complex matrices prior to detection via non-destructive assay by gamma spectroscopy or destructive analysis with mass spectrometry. PNNL previously reported some of its initial modeling work as proof of principle. Here we will provide a general overview of the technologies and the ongoing demonstrations that utilize actual spent fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Poly(3,4-ethylenedioxypyrrole) Modified Emitter Electrode for Substitution of Homogeneous Redox Buffer Agent Hydroquinone in Electrospray Ionization Mass Spectrometry

The electrolysis inherent to the operation of the electrospray ionization (ESI) source used with mass spectrometry (MS) is a well-known attendant effect of generating unipolar spray droplets and may affect the analysis of the analyte of interest. Undesirable electrolysis of an analyte may be prevented by limiting the emitter electrode current and/or the mass transport characteristics of the system. However, these ways to avoid analyte electrolysis may not be applcable in all ESI-MS experiments. For example, in the case of specific nanospray systems (e.g. the wire-in-a-capillary bulk-loaded or chip-based tip-loaded nanospray configurations), the solution flow rate is fixed in the 50-500 nL/min range and the electrode surface to volume ratio is large presenting a very effcient analyte to electrode mass transport configuration. In these situations, control over the interfacial potential of the working electrode via homogeneous or traditional heterogeneous (sacrificial metal) redox buffering is a possible way to prevent analyte electrolysis. However, byproducts of these redox buffering approaches can appear in the mass spectra and/or they can chemically alter the analyte. For example, the main reason for using hydroquinone as a homogeneous redox buffer, in addition to its relatively low oxidation potential, is that neither the original compound nor its oxidation product benzoquinone can be detected directly by ESI-MS. However, benzoquinone can alter analytes with thiol functional groups by reacting with those groups via a 1,4-Michael addition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emission of volatile sulfur compounds during composting of municipal solid waste (MSW)

Highlights: ► We compare the volatile sulfur compounds (VSCs) emissions during three types of municipal solid wastes (MSWs) composting. ► The VSCs released from the kitchen waste composting was significantly higher than that from 15–80 mm fraction of MSW. ► Among the five VSCs, H{sub 2}S was the most abundant compound with 39.0–43.0% of total VSCs released. ► Addition of 20% cornstalks could significantly reduce the VSCs emissions during kitchen waste composting. - Abstract: Volatile sulfur compounds (VSCs) are the main source for malodor from composting plants. In this study, the VSCs generated from composting of 15–80 mm municipal solid waste (T0), kitchen waste (T1) and kitchen waste mixed dry cornstalks (T2) were measured in 60 L reactors with forced aeration for a period of 30 days. The VSCs detected in all treatments were hydrogen sulfide (H{sub 2}S), methyl mercaptan (MM), dimethyl sulfide (DMS), carbon bisulfide (CS{sub 2}) and dimethyl disulfide (DMDS). Over 90% of the VSCs emissions occurred during the first 15 days, and reached their peak values at days 4–7. The emission profiles of five VSCs species were significantly correlated with internal materials temperature and outlet O{sub 2} concentration (p < 0.05). Total emissions of the VSCs were 216.1, 379.3 and 126.0 mg kg{sup −1} (dry matter) for T0, T1 and T2, respectively. Among the five VSCs, H{sub 2}S was the most abundant compound with 39.0–43.0% of total VSCs released. Composting of kitchen waste from separate collection posed a negative influence on the VSC and leachate production because of its high moisture content. An addition of dry cornstalks at a mixing ratio of 4:1 (wet weight) could significantly reduce the VSCs emissions and avoid leachate. Compared to pure kitchen waste, VSCs were reduced 66.8%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DESI 2024 III: baryon acoustic oscillations from galaxies and quasars

We present the DESI 2024 galaxy and quasar baryon acoustic oscillations (BAO) measurements using over 5.7 million unique galaxy and quasar redshifts in the range 0.1 < z < 2.1. Divided by tracer type, we utilize 300,017 galaxies from the magnitude-limited Bright Galaxy Survey with 0.1 < z < 0.4, 2,138,600 Luminous Red Galaxies with 0.4 < z < 1.1, 2,432,022 Emission Line Galaxies with 0.8 < z < 1.6, and 856,652 quasars with 0.8 < z < 2.1, over a ∼ 7,500 square degree footprint. The analysis was blinded at the catalog-level to avoid confirmation bias. All fiducial choices of the BAO fitting and reconstruction methodology, as well as the size of the systematic errors, were determined on the basis of the tests with mock catalogs and the blinded data catalogs. We present several improvements to the BAO analysis pipeline, including enhancing the BAO fitting and reconstruction methods in a more physically-motivated direction, and also present results using combinations of tracers. We employ a unified BAO analysis method across all tracers. We present a re-analysis of SDSS BOSS and eBOSS results applying the improved DESI methodology and find scatter consistent with the level of the quoted SDSS theoretical systematic uncertainties. With the total effective survey volume of ∼ 18 Gpc3, the combined precision of the BAO measurements across the six different redshift bins is ∼0.52%, marking a 1.2-fold improvement over the previous state-of-the-art results using only first-year data. We detect the BAO in all of these six redshift bins. The highest significance of BAO detection is 9.1σ at the effective redshift of 0.93, with a constraint of 0.86% placed on the BAO scale. We find that our observed BAO scales are systematically larger than the prediction of the Planck 2018-ΛCDM at z < 0.8. We translate the results into transverse comoving distance and radial Hubble distance measurements, which are used to constrain cosmological models in our companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

THE UDF05 FOLLOW-UP OF THE HUBBLE ULTRA DEEP FIELD. III. THE LUMINOSITY FUNCTION AT z {approx} 6

In this paper, we present a derivation of the rest-frame 1400 A luminosity function (LF) at redshift six from a new application of the maximum likelihood method by exploring the five deepest Hubble Space Telescope/Advanced Camera for Surveys (HST/ACS) fields, i.e., the Hubble Ultra Deep Field, two UDF05 fields, and two Great Observatories Origins Deep Survey fields. We work on the latest improved data products, which makes our results more robust than those of previous studies. We use unbinned data and thereby make optimal use of the information contained in the data set. We focus on the analysis to a magnitude limit where the completeness is larger than 50% to avoid possibly large errors in the faint end slope that are difficult to quantify. We also take into account scattering in and out of the dropout sample due to photometric errors by defining for each object a probability that it belongs to the dropout sample. We find the best-fit Schechter parameters to the z {approx} 6 LF are {alpha} = 1.87 {+-} 0.14, M{sub *} = -20.25 {+-} 0.23, and {phi}{sub *} = 1.77{sup +0.62}{sub -0.49} x 10{sup -3} Mpc{sup -3}. Such a steep slope suggests that galaxies, especially the faint ones, are possibly the main sources of ionizing photons in the universe at redshift six. We also combine results from all studies at z {approx} 6 to reach an agreement in the 95% confidence level that -20.45 < M{sub *} < -20.05 and -1.90 < {alpha} < -1.55. The luminosity density has been found not to evolve significantly between z {approx} 6 and z {approx} 5, but considerable evolution is detected from z {approx} 6 to z {approx} 3.

79 ASTRONOMY AND ASTROPHYSICS↗

In which shell-type SNRs should we look for gamma-rays and neutrinos from P-P collisions?

We present a simple analytic model for the various contributions to the non-thermal emission from shell-type SNRs and show that this model's results reproduce well the results of previous detailed calculations. We show that the {>=}1 TeV gamma ray emission from the shell type SNRs RX J1713.7-3946 and RX J0852.0-4622 is dominated by inverse-Compton scattering of CMB photons (and possibly infrared ambient photons) by accelerated electrons. Pion decay (due to proton-proton collisions) is shown to account for only a small fraction, {approx}<10{sup -2}, of the observed flux, as assuming a larger fractional contribution would imply non-thermal radio and x-ray synchrotron emission and thermal x-ray bremsstrahlung emission that far exceed the observed radio and x-ray fluxes. Models where pion decay dominates the {>=}1 TeV flux avoid the implied excessive synchrotron emission (but not the implied excessive thermal x-ray bremsstrahlung emission) by assuming an extremely low efficiency of electron acceleration, K{sub ep}{approx}<10{sup -4} (where K{sub ep} is the ratio of the number of accelerated electrons to the number of accelerated protons at a given energy). We argue that observations of SNRs in nearby galaxies imply a lower limit of K{sub ep}{approx}>10{sup -3}, and thus rule out K{sub ep} values {approx}<10{sup -4} (assuming that SNRs share a common typical value of K{sub ep}). It is suggested that SNRs with strong thermal x-ray emission, rather than strong non-thermal x-ray emission, are more suitable candidates for searches of gamma rays and neutrinos resulting from proton-proton collisions. In particular, it is shown that the neutrino flux from the SNRs above is probably too low to be detected by current and planned neutrino observatories. Finally, we note that the magnetic field value implied by the comparison of x-ray to gamma-ray emission, {approx}10 Micro-Sign G, can be used to constrain magnetic field amplification.

79 ASTRONOMY AND ASTROPHYSICS↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-eddington accretion in the ultraluminous x-ray source NGC 1313 X-2: An ephemeral feast

We investigate the X-ray spectrum, variability, and the surrounding ionized bubble of NGC 1313 X-2 to explore the physics of super-Eddington accretion. Beyond the Eddington luminosity, the accretion disk of NGC 1313 X-2 is truncated at a large radius (∼50 times the innermost stable circular orbit), and displays the similar evolution track with both luminous Galactic black-hole and neutron star X-ray binaries (XRBs). In super-critical accretion, the speed of radiatively driven outflows from the inner disk is mildly relativistic. Such ultra-fast outflows would be overionized and might produce weak Fe K absorption lines, which may be detected by the coming X-ray mission Astro-H. If NGC 1313 X-2 is a massive stellar XRB, the high luminosity indicates that an ephemeral feast is held in the source. That is, the source must be accreting at a hyper-Eddington mass rate to give the super-Eddington emission over ∼10{sup 4}-10{sup 5} yr. The expansion of the surrounding bubble nebula with a velocity of ∼100 km s{sup –1} might indicate that it has existed over ∼10{sup 6} yr and is inflated by the radiatively driven outflows from the transient with a duty cycle of activity of ∼ a few percent. Alternatively, if the surrounding bubble nebula is produced by line-driven winds, less energy is required than the radiatively driven outflow scenario, and the radius of the Strömgren radius agrees with the nebula size. Our results are in favor of the line-driven winds scenario, which can avoid the conflict between the short accretion age and the apparently much longer bubble age inferred from the expansion velocity in the nebula.

79 ASTRONOMY AND ASTROPHYSICS↗

AlloSHP: deconvoluting single homeologous polymorphism for phylogenetic analysis of allopolyploids

Background The genomic and evolutionary study of allopolyploid organisms involves multiple copies of homeologous chromosomes, making their assembly, annotation, and phylogenetic analysis challenging. Bioinformatics tools and protocols have been developed to study polyploid genomes, but sometimes require the assembly of their genomes, or at least the genes, limiting their use. Results We have developed AlloSHP, a command-line tool for detecting and extracting single homeologous polymorphisms (SHPs) from the subgenomes of allopolyploid species. This tool integrates three main algorithms, WGA, VCF2ALIGNMENT and VCF2SYNTENY, and allows the detection of SHPs for the study of diploid-polyploid complexes with available diploid progenitor genomes, without assembling and annotating the genomes of the allopolyploids under study. AlloSHP has been validated on three diploid-polyploid plant complexes, Brachypodium, Brassica, and Triticum-Aegilops, and a set of synthetic hybrid yeasts and their progenitors of the genus Saccharomyces. The results and congruent phylogenies obtained from the four datasets demonstrate the potential of AlloSHP for the evolutionary analysis of allopolyploids with a wide range of ploidy and genome sizes. Conclusions AlloSHP combines the strategies of simultaneous mapping against multiple reference genomes and syntenic alignment of these genomes to call SHPs, using as input data a single VCF file and the reference genomes of the known or closest extant diploid progenitor species. This novel approach provides a valuable tool for the evolutionary study of allopolyploid species, both at the interspecific and intraspecific levels, allowing the simultaneous analysis of a large number of accessions and avoiding the complex process of assembling polyploid genomes.

Allopolyploids↗