Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cyber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BioSecure Digital Twin: Manufacturing Innovation and Cybersecurity Resilience

U.S. national security, prosperity, economy, and well-being require secure, flexible, and resilient Biopharmaceutical Manufacturing. The COVID-19 pandemic reaffirmed that the biomedical production value-chain is vulnerable to disruption and has been under attack from sophisticated nation-state adversaries. Current cyber defenses are inadequate, and the integrity of critical production systems and processes are inherently vulnerable to cyber-attacks, human error, and supply chain disruptions. The following chapter explores how a BioSecure Digital Twin will improve U.S. manufacturing resilience and preparedness to respond to these hazards by significantly improving monitoring, integrity, security, and agility of our manufacturing infrastructure and systems. The BioSecure Digital Twin combines a scalable manufacturing framework with a robust platform for monitoring and control to increase U.S. biopharma manufacturing resilience. Then, the chapter discusses some of the inherent vulnerabilities and challenges at the nexus of health and advanced manufacturing. Next, the chapter highlights that as the Pandemic evolves, we need agility and resilience to overcome significant obstacles. This section highlights an innovative application of Cyber Informed Engineering to developing and deploying a BioSecure Digital Twin to improve the resilience and security of the biopharma industrial supply chain and production processes. Finally, the chapter concludes with a process framework to complement the Digital Twin platform, called the Biopharma (Observe, Orient, Decide, Act) OODA Loop Framework (BOLF), a four-step approach to decision-making outputs from the Digital Twin. The BOLF will help end users leverage twin technology by distilling the available information, focusing the data on context, and rapidly making the best decision while remaining cognizant of changes that can be made as more data becomes available.

99 GENERAL AND MISCELLANEOUS↗

Cybersecurity concerns for the energy sector in the maritime domain

The world has seen a number of high-profile maritime disasters in recent months and years, and has felt the impact of them. At the same time, the world has also seen a number of high-profile cyberattacks. It has felt their impact, as well. And, likely no sector has been more affected by the maritime and cyber incidents than the energy sector, as fuel prices often spike or trough, and access to energy resources can become an instant source of concern, tension, or even conflict. As energy sectors—in all their forms—continue to rely on the maritime domain or even increase that reliance, they must be mindful that traditional maritime threats—like piracy, theft, and weather events—are not the only threats they face today. Maritime cybersecurity concerns are among the most potentially disruptive to energy-sector interests and, yet, are among the least understood and least addressed. This paper identifies nine areas in which the energy sector faces harmful cyber vulnerabilities in the maritime domain, to provide enough insight and examples to allow for action to be taken to reduce the risk of harm from these different vulnerabilities. The paper develops the example of offshore wind energy to model how to assess cyber considerations more fully. Ultimately, it concludes with a series of recommendations that offer policymakers, energy-sector actors, and security and law-enforcement professionals steps to minimize the exposure of the maritime energy sector to harmful cyberattacks.

99 GENERAL AND MISCELLANEOUS↗

Power and Communications Hardware-in-the-Loop CPS Architecture and Platform for DER Monitoring and Control Applications: Preprint

The rapid growth of distributed energy resources (DERs) has prompted increasing interest in the monitoring and control of DERs through hybrid smart grid communications. The deployment of communications and computation has transformed the traditional physical power grid into a smart cyber-physical system (CPS). To fully understand the interdependency between physical grid and cyber netowrks, this study designed a power and communications hardware-in-the-loop (PCommHIL) CPS architecture, which enables the flexible verification of DER monitoring and control with hybrid communications architectures and Internet protocols. Design, development and case study of a PCommHIL testbed for the DER coordination are discussed in detail, and the proposed platform integrates DER devices, Advanced Metering Infrastructures (AMIs), and a suite of hybrid communications networks for distribution automation applications. Case study on DER situational awareness and Volt-Var control validates the efficacy of this proposed PCommHIL platform with hybrid communications designs. Results show that the HAN communication technologies play a critical role in hybrid designs and it is the bottleneck for DER applications. High performance communication technologies are highly recommended to be applied in the HAN for enhanced monitoring and real-time control of DERs.

AMIs↗

Mental Models for Managing Grid Cybersecurity Risk - ARC Industry Forum, Cybersecurity and Energy Transition

A proper mental model of the concepts of cyber risk and its components of threat and exploitability and consequence is necessary to allocate limited resources to different security activities, especially when considered alongside reliability and regulatory and economic risks. Understanding the consequence and frequency different risks are realized also helps align the right mitigations to the right risks. Cyber-informed engineering (CIE) is an emerging method to “engineer out” cyber risk across product and system lifecycles, and INL has a portfolio of programs operationalizing CIE’s principles for the energy sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Idaho National Laboratory Energy Cybersecurity Programs Update

This brief presentation provides a status update on three Idaho National Laboratory energy cybersecurity programs of particular interest to NERC Reliability and Security Technical Committee annual in-person Security Groups summit. Public information on the following three programs is included: Cybersecurity for Operational Technology Environments (CyOTE™) program Cyber-Informed Engineering (CIE) Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, and associated high-level information on the Energy Software Bill of Materials POC, Executive Order 14017, and the Energy Cyber Sense Act

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing

Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.

Aguayo, Jared M.↗

PMU and Communication Infrastructure Restoration for Post-Attack Observability Recovery of Power Grids

This paper is concerned about recovering the observability of cyber-physical power grids after massive cyber attacks, which helps to achieve the cyber-physical resilience of the grids. For recovering the observability of the grid, the measurability of the Phasor Measurement Units (PMUs) and the connectivity of the communication network are needed to be restored. The PMU and communication infrastructure restoration problem is jointly formulated as a Mixed Integer Linear Programming (MILP) problem to minimize the observability loss of the grid over time after a cyber attack while considering the constraint of limited resources. The efficacy of the proposed optimal restoration strategy is verified by comparing with heuristic methods on the IEEE 57-bus system.

cyber security↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation: Preprint

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyber attacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyber attack scenarios on matrix completion. Realistic cyber attack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Integrating Cybersecurity Risk Assessment with Process Safety in Chemical Process Industries

This dissertation bridges the gap between industrial cybersecurity and traditional process safety by introducing an integrated Cyber-LOPA framework that combines the Purdue Enterprise Reference Architecture, Cyber Kill Chain, and CVSS v4.0 metrics. Demonstrated on a High-Density Polyethylene slurry process, the work illustrates how cyber threats targeting automation systems can bypass physical protection layers, proving the necessity of unified risk assessments to prevent cyber-induced physical incidents in chemical manufacturing plants.

Cyber-LOPA (CLOPA)↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Load altering attack-tolerant defense strategy for load frequency control system

Cyber attacks are emerging threats to every information-oriented energy management system. By violating the cyber systems, the hacker can disrupt the security and stability due to the strong coupling between the cyber and physical facilities. In this paper, one type of cyber attacks designated as the load altering attack is studied for the power system frequency control, and corresponding defense strategies are proposed to improve the frequency control performance. Considering the difficulty of the application of model-based controller into large-scale power systems, a novel model-free defense framework is for the first time presented. Under this framework, both active defense and passive defense strategies are designed. The former assumes that the defender has the initiative to learn different attack scenarios. Adaptive defense strategies are implemented using the online attack identification information and off-line trained strategy pool. The latter assumes that the defender passively tolerates various attack scenarios via the pre-trained off-line strategy. Both approaches prove to be effective through validation based on the IEEE benchmark systems. The proposed defense framework and defense strategies can be extended to other energy control systems to enhance their attack tolerance capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible visualization of a 3rd party Intrusion Prevention (Security) tool: A use case with the ELK stack

A difficult aspect of cyber security is the ability to achieve automated real time intrusion prevention across various sets of systems. To this extent, several companies are offering comprehensive solutions that leverage an "accuracy of scale" and moving much of the intelligence and detection on the Cloud, relying on an ever-growing set of data and analytics to increase decision accuracy. Often, they provide tools to visualize the decision workflows in attack prevention (as well as tune the algorithm) but those solutions are not always practical as companies see the problem as "global" that is, from a unified Cyber-security standpoint. However, a key to a successful Cyber-security program is transparency and trust: from an experimental team viewpoint, this specifically means having the ability to immediately see what and from where, who has been blocked and being able to inform the community in case of a revoked access without the need for filing a "ticket" (that may eventually be answered) – in other words, rapid response to their user-base is essential but solutions targeting "sub-groups" in an organization are not often available. We have come up with a versatile solution leveraging the ELK stack (Elasticsearch, Logstash, & Kibana) and an IPS (Intrusion Prevention System) based WAF (Web Application Firewall) from Signal Sciences. Signal Science allows the streaming of detailed logs in a Logstash format suitable for custom solutions for visualization. By combining these two tools, we have strengthened our security posture and enabled individual experiments to monitor their own traffic. Specifically, the IPS WAF provides unique data such as country of origin, protocol, response code, source IP, and paths accessed. In this contribution, we will show how we engineered a visualization solution so experiment groups could access a dashboard with predefined graphs but also, where they can create individual customizable dashboards used to display blocked traffic and troubleshoot latency issues. We will discuss the details and procedures for developing and configuring these tools and how it benefits cyber security postures across our scientific based environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distributed Detection of Malicious Attacks on Consensus Algorithms with Applications in Power Networks

Consensus-based distributed algorithms are well suited for coordination among agents in a cyber-physical system. These distributed schemes, however, suffer from their vulnerability to cyber attacks that are aimed at manipulating data and control ow. In this article, we present a novel distributed method for detecting the presence of such intrusions for a distributed multi-agent system following ratio consensus. We employ a Max-Min protocol to develop low cost, easy to implement detection strategies where each participating node detects the intrusion independently, eliminating the need for a trusted certifying agent in the network. The effectiveness of the detection method is demonstrated by numerical simulations on a 1000 node network to demonstrate the efficacy and simplicity of implementation.

27 ARPA - Advanced Research Projects Agency-Energy↗

Enhancing Network Anomaly Detection Using Graph Neural Networks

In the world of Internet of Things (IoT) networks, where devices are constantly communicating, keeping them secure from cyber threats is critical. This paper introduces a novel approach to detecting unusual and potentially harmful activities in these networks using graph neural networks (GNNs). We combine two specific types of GNNs-GraphSAGE and graph attention networks (GAT)-to create a model that understands and represents the behaviors and interactions in a network. GraphSAGE creates an embedding of network activities by examining local data interactions, while GAT directs the model's focus to the most critical interactions. By integrating these two methods in a single model that considers different types of interactions (both host and flow nodes), we aim to create a system that accurately represents the current state of a network and can also spot anomalies effectively while reducing false positives and negatives. Our innovative approach has demonstrated promising results, achieving an accuracy of 98% on the UNSW-NB15 dataset, significantly outperforming standalone GraphSAGE and GAT models. This underscores its potential as a robust framework for securing IoT networks against cyber threats and anomalies.

Marfo, William↗

Leveraging High-Fidelity Datasets for Machine Learning-based Anomaly Detection in Smart Grids

Data-driven intrusion detection systems are increasingly becoming essential for protecting critical cyber-physical infrastructure, such as the power grid, against the growing number of sophisticated cyber-attacks. The development of such tools is reliant on the availability of high-fidelity cyber-physical datasets that cover a diverse variety of potential cyber events. In this work, a high-fidelity smart grid platform is utilized to develop an extensive dataset, which is used to train and test a machine learning-based intrusion detection system. The evaluation of the developed IDS shows robust performance even when tested with statistically diverse test data not used in training.

Hyder, Burhan↗

Improved microgrid resiliency through distributionally robust optimization under a policy-mode framework

Critical energy infrastructure are constantly under stress due to the ever increasing disruptions caused by wildfires, hurricanes, other weather related extreme events and cyber-attacks. Hence it becomes important to make critical infrastructure resilient to threats from such cyber-physical events. However, such events are hard to predict and numerous in nature and type and it becomes infeasible to make a system resilient to every possible such cyber-physical event. Such an approach can make the system operation overly conservative and impractical to operate. Furthermore, distributions of such events are hard to predict and historical data available on such events can be very sparse, making the problem even harder to solve. To deal with these issues, in this paper we present a policy-mode framework that enumerates and predicts the probability of various cyber-physical events and then a distributionally robust optimization (DRO) formulation that is robust to the sparsity of the available historical data. The proposed algorithm is illustrated on an islanded microgrid example: a modified IEEE 123-node feeder with distributed energy resources (DERs) and energy storage. Simulations are carried to validate the resiliency metrics under the sampled disruption events.

Nazir, Mohammad Nawaf↗