Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Account”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Arctic tundra shrubification: a review of mechanisms and impacts on ecosystem carbon balance

Abstract Vegetation composition shifts, and in particular, shrub expansion across the Arctic tundra are some of the most important and widely observed responses of high-latitude ecosystems to rapid climate warming. These changes in vegetation potentially alter ecosystem carbon balances by affecting a complex set of soil–plant–atmosphere interactions. In this review, we synthesize the literature on (a) observed shrub expansion, (b) key climatic and environmental controls and mechanisms that affect shrub expansion, (c) impacts of shrub expansion on ecosystem carbon balance, and (d) research gaps and future directions to improve process representations in land models. A broad range of evidence, including in-situ observations, warming experiments, and remotely sensed vegetation indices have shown increases in growth and abundance of woody plants, particularly tall deciduous shrubs, and advancing shrublines across the circumpolar Arctic. This recent shrub expansion is affected by several interacting factors including climate warming, accelerated nutrient cycling, changing disturbance regimes, and local variation in topography and hydrology. Under warmer conditions, tall deciduous shrubs can be more competitive than other plant functional types in tundra ecosystems because of their taller maximum canopy heights and often dense canopy structure. Competitive abilities of tall deciduous shrubs vs herbaceous plants are also controlled by variation in traits that affect carbon and nutrient investments and retention strategies in leaves, stems, and roots. Overall, shrub expansion may affect tundra carbon balances by enhancing ecosystem carbon uptake and altering ecosystem respiration, and through complex feedback mechanisms that affect snowpack dynamics, permafrost degradation, surface energy balance, and litter inputs. Observed and projected tall deciduous shrub expansion and the subsequent effects on surface energy and carbon balances may alter feedbacks to the climate system. Land models, including those integrated in Earth System Models, need to account for differences in plant traits that control competitive interactions to accurately predict decadal- to centennial-scale tundra vegetation and carbon dynamics.

54 ENVIRONMENTAL SCIENCES↗

Temporal Wind Pairs for Space Launch Vehicle Capability Assessment and Risk Mitigation

Space launch vehicles incorporate upper-level wind assessments to determine wind effects on the vehicle and for a commit to launch decision. These assessments make use of wind profiles measured hours prior to launch and may not represent the actual wind the vehicle will fly through. Uncertainty in the winds over the time period between the assessment and launch introduces uncertainty in assessment of vehicle controllability and structural integrity that must be accounted for to ensure launch safety. Temporal wind pairs are used in engineering development of allowances to mitigate uncertainty. Five sets of temporal wind pairs at various times (0.75, 1.5, 2, 3 and 4-hrs) at the United States Air Force Eastern Range and Western Range, as well as the National Aeronautics and Space Administration's Wallops Flight Facility are developed for use in upper-level wind assessments on vehicle performance. Historical databases are compiled from balloon-based and vertically pointing Doppler radar wind profiler systems. Various automated and manual quality control procedures are used to remove unacceptable profiles. Statistical analyses on the resultant wind pairs from each site are performed to determine if the observed extreme wind changes in the sample pairs are representative of extreme temporal wind change. Wind change samples in the Eastern Range and Western Range databases characterize extreme wind change. However, the small sample sizes in the Wallops Flight Facility databases yield low confidence that the sample population characterizes extreme wind change that could occur.

Decker, Ryan K.↗

Temporal Wind Pairs for Space Launch Vehicle Capability Assessment and Risk Mitigation

Space launch vehicles incorporate upper-level wind assessments to determine wind effects on the vehicle and for a commit to launch decision. These assessments make use of wind profiles measured hours prior to launch and may not represent the actual wind the vehicle will fly through. Uncertainty in the winds over the time period between the assessment and launch introduces uncertainty in assessment of vehicle controllability and structural integrity that must be accounted for to ensure launch safety. Temporal wind pairs are used in engineering development of allowances to mitigate uncertainty. Five sets of temporal wind pairs at various times (0.75, 1.5, 2, 3 and 4-hrs) at the United States Air Force Eastern Range and Western Range, as well as the National Aeronautics and Space Administration's Wallops Flight Facility are developed for use in upper-level wind assessments on vehicle performance. Historical databases are compiled from balloon-based and vertically pointing Doppler radar wind profiler systems. Various automated and manual quality control procedures are used to remove unacceptable profiles. Statistical analyses on the resultant wind pairs from each site are performed to determine if the observed extreme wind changes in the sample pairs are representative of extreme temporal wind change. Wind change samples in the Eastern Range and Western Range databases characterize extreme wind change. However, the small sample sizes in the Wallops Flight Facility databases yield low confidence that the sample population characterizes extreme wind change that could occur.

Decker, Ryan K.↗

RAMP - A fault tolerant distributed microcomputer structure for aircraft navigation and control

Design methodologies for realizing future high authority autoflight control systems are being investigated, taking into account also the study of distributed microcomputer architectures. Attention is given to the redundant asynchronous microprocessor (RAMP) structure. RAMP comprises a connected network of microcomputers which has as input command and sensor information, and which generates servo information to drive actuators, and thrust linkages. Tolerance to hardware failures is achieved by static redundancy. Results of a failed microcomputer are simply rejected. This is done in lieu of dynamic redundancy wherein the distributed computer system performs real time fault detection and reconfiguration of the system. Attention is given to the RAMP network structure and operation, flight control with parallel asynchronous computers, and intermittent fault tolerance.

Dunn, W. R.↗

Optimal Water-Power Flow Problem: Formulation and Distributed Optimal Solution

This paper formalizes an optimal water-power flow (OWPF) problem to optimize the use of controllable assets across power and water systems while accounting for the couplings between the two infrastructures. Tanks and pumps are optimally managed to satisfy water demand while improving power grid operations; {for the power network, an AC optimal power flow formulation is augmented to accommodate the controllability of water pumps.} Unfortunately, the physics governing the operation of the two infrastructures and coupling constraints lead to a nonconvex (and, in fact, NP-hard) problem; however, after reformulating OWPF as a nonconvex, quadratically-constrained quadratic problem, a feasible point pursuit-successive convex approximation approach is used to identify feasible and optimal solutions. In addition, a distributed solver based on the alternating direction method of multipliers enables water and power operators to pursue individual objectives while respecting the couplings between the two networks. The merits of the proposed approach are demonstrated for the case of a distribution feeder coupled with a municipal water distribution network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chilled water temperature set-point reset based on outdoor air temperature and its cooling energy performance in an office building

Here, in this study, the cooling energy performance of two strategies for controlling ChWT (chilled water temperature) are compared: the conventional control strategy of constantly fixing ChWT and the OAT (outdoor air temperature) compensation control strategy that adjusts ChWT according to the changes in OAT. OAT compensation control strategy was modeled and realized based on Appendix G of ASHRAE Standard 90.1. It was confirmed that applying OAT compensation control strategy can significantly reduce chiller energy consumption, which accounts for the largest portion of total cooling energy consumption. It was found that the difference in total cooling energy consumption between applying the conventional control of constantly fixing ChWT to 6 °C and applying the OAT compensation control was approximately 8 % and 3 % during spring (March to May) and summer (June to August), respectively. Additionally, during the fall (September–November) period, about 7 % of total cooling energy consumption could be saved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-driven efficient network and surveillance-based immunization

Given a contact network and coarse-grained diagnostic information such as electronic Healthcare Reimbursement Claims (eHRC) data, can we develop efficient intervention policies from data to control an epidemic? Immunization is an important problem in multiple areas, especially epidemiology and public health. However, most existing studies rely on assuming prior epidemiological models to develop pre-emptive strategies, which may fail to adapt to the change in new epidemiological patterns and the availability of rich data such as eHRC. In practice, disease spread is usually complicated, hence assuming an underlying model may deviate from true spreading patterns, leading to possibly inaccurate interventions. Additionally, the abundance of health care surveillance data (such as eHRC) makes it possible to study data-driven strategies without too many restrictive assumptions. Therefore, such a data-driven intervention approach can help public-health experts take more practical decisions. In this work, we take into account propagation log and contact networks for controlling propagation. Furthermore, different from previous model-based approaches, our solutions are solely data driven in a sense that we develop immunization strategies directly from the network and eHRC without assuming classical epidemiological models. In particular, we formulate the novel and challenging data-driven immunization problem. To solve it, we first propose an efficient sampling approach to align surveillance data with contact networks, then develop an efficient algorithm with the provably approximate guarantee for immunization. Finally, we show the effectiveness and scalability of our methods via extensive experiments on multiple datasets, and conduct case studies on nation-wide real medical surveillance data.

60 APPLIED LIFE SCIENCES↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Reinforcement Learning for Volt- Var Control: A Novel Two-stage Progressive Training Strategy

This paper develops a reinforcement learning (RL) approach to solve a cooperative, multi-agent Volt-Var Control (VVC) problem for high solar penetration distribution systems. The ingenuity of our RL method lies in a novel two-stage progressive training strategy that can effectively improve training speed and convergence of the machine learning algorithm. In Stage 1 (individual training), while holding all the other agents inactive, we separately train each agent to obtain its own optimal VVC actions in the action space: fconsume, generate, do-nothingg. In Stage 2 (cooperative training), all agents are trained again coordinatively to share VVC responsibility. Rewards and costs in our RL scheme include (i) a system-level reward (for taking an action), (ii) an agent-level reward (for doing-nothing), and (iii) an agent-level action cost function. This new framework allows rewards to be dynamically allocated to each agent based on their contribution while accounting for the trade-off between control effectiveness and action cost. The proposed methodology is tested and validated in a modified IEEE 123-bus system using realistic PV and load profiles. Simulation results confirm that the proposed approach is robust and computationally efficient; and it achieves desirable volt-var control performance under a wide range of operation conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Flexible Evolvable Architecture for Constellation Mission Systems User Applications

While simulating a complex set of repair tasks to be performed by EVA crewmembers on an upcoming mission, flight controllers and astronauts determine that the repair will take much longer than originally anticipated. All equipment in the vicinity of the worksite must be powered off to maintain a safe environment for the astronauts. Because heater power will be unavailable, several critical components will now be at risk of freezing and permanent damage. If an impending thermal violation is detected, Mission Control will have very limited time to react. Therefore, flight controllers must not only modify their procedures to account for these risks, they must also incorporate into their displays outputs from thermal models, alternate temperature measurements, new alarm limits, and emergency power-on commands to enable the detection and response to freezing conditions. Current software for mission control systems makes scenarios like this difficult to address. Given the time frame for modifying software, operations teams are left with labor-intensive operational workarounds as their only options. NASA Ames Research Center (ARC) and NASA Johnson Space Center (JSC) are collaborating on the development of a flexible software system for mission operations that will enable greater user flexibility than has been available to date. Using composable software, end users in the scenario described above could recompose procedures and command and control displays to allow flight controllers to monitor temperature measurements, identify time-critical conditions, and execute the procedures required to respond to these conditions before flight hardware is permanently damaged.

Trimble, Jay P.↗

Quantification of reactivity margin in BWR spent fuel pools

Boiling water reactor (BWR) spent fuel pool (SFP) criticality safety analyses typically use the in-core k{sub inf} criterion methodology to demonstrate margin to safety. This method models all the fuel in the SFP with a limiting lattice design at a peak reactivity just above a specific in-core k{sub inf} limit. To bound all the fuel in the pool and future fuel with reasonable margin, these limits are often set conservatively high compared to the peak reactivities of actual BWR bundle designs. When current regulatory expectations are met for the quantification of bias and uncertainty adders to the criticality analyses, some results are quantified that are close to the 0.95 in-rack reactivity limit required by 10CFR50.68. The small margins being calculated in the criticality safety analyses have resulted in concerns that SFPs have less margin to safety than was present in the past; however, inherent in the peak reactivity in-core k{sub inf} criterion methodology used to assess these margins is a very conservative model of the fuel. While it is known that all the fuel in a BWR SFP is typically burned well past its peak reactivity exposure, it has been unknown how much reactivity margin could be quantified if bundles were modeled more realistically by accounting for their actual discharge exposure profiles, operational void fractions, control histories, and depletion fuel temperatures. In this study, fuel bundles were depleted to their explicit nodal discharge exposure while accounting for actual operational conditions defined by GEH/GNF's core simulator code, PANACEA. The use of these depleted isotopics in the criticality safety analysis is commonly referred to as taking 'burn-up credit' in the analysis. This paper provides a quantification of the reactivity margin available from burn-up credit in two currently operating BWR spent fuel pools. The evaluation demonstrates that many of the bundles in these storage configurations are significantly below the in-rack reactivity limit, even with the necessary bias and uncertainty adders included. The utilization of BWR burnup credit appears to be an attractive solution to consider when evaluating options for reduced neutron absorber credit or for quantifying additional margin to the regulatory in-rack k{sub eff} limit. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nonlinear control of safety factor gradient in tokamaks using spatially variable electron cyclotron current drives

Active control of plasma properties may be necessary to achieve stable operation of next-generation tokamaks over large time scales. Such control algorithms can regulate the plasma properties to avoid the onset of magnetohydrodynamic (MHD) instabilities. For instance, the global and local properties of the safety factor profile are linked to the onset of neoclassical tearing modes (NTMs). This work proposes a model-based control approach for deterring/delaying NTMs through active modulation of one of the safety factor properties - the gradient of the safety factor profile at a particular rational safety factor surface. In particular, a novel control-oriented model for the local safety factor gradient is developed. The nonlinear control model is governed by a nonautonomous ordinary differential equation that accounts for a given rational safety factor surface’s spatial variation over time. Further, to improve the controllability of the spatially evolving parameter, the control model treats ECH&CD positions, along with noninductive powers, as controllable variables. A nonlinear control algorithm based on feedback linearization with optimization is synthesized to achieve the objective of regulating the safety factor gradient around a given target. The proposed algorithm allocates optimal ECH&CD positions, in addition to auxiliary powers, at each time instant as the rational safety factor surface drifts to locations with a low control authority. Stability guarantees of the proposed control law are also discussed in this work. The proposed algorithm is tested for a DIII-D tokamak scenario in nonlinear simulations carried out using the Control Oriented Transport SIMulator (COTSIM). Both fixed and moving ECH&CD cases are studied, and their outcomes are compared. Simulation results demonstrate that enthusiastic regulation of the safety factor gradient can be achieved during the ramp-up and flat-top phases of tokamak operation in both fixed and moving ECH&CD cases. However, real-time updates of ECH&CD positions can prevent the saturation of auxiliary powers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced regulatory control and coordinated plant-wide control strategies for IGCC targeted towards improving power ramp-rates

As part of ongoing R&D activities at the National Energy Technology Laboratory's (NETL) Advanced Virtual Energy Simulation Training & Research (AVESTAR™) Center, this paper highlights strategies for enhancing low-level regulatory control and system-wide coordinated control strategies implemented in a high-fidelity dynamic simulator for an Integrated Gasification Combined Cycle (IGCC) power plant with carbon capture. The underlying IGCC plant dynamic model contains 20 major process areas, each of which is tightly integrated with the rest of the power plant, making individual functionally-independent processes prone to routine disturbances. Single-loop feedback control although adequate to meet the primary control objective for most processes, does not take into account in advance the effect of these disturbances, making the entire power plant undergo large offshoots and/or oscillations before the feedback action has an opportunity to impact control performance. In this paper, controller enhancements ranging from retuning feedback control loops, multiplicative feed-forward control and other control techniques such as split-range control, feedback trim and dynamic compensation, applicable on various subsections of the integrated IGCC plant, have been highlighted and improvements in control responses have been given. Compared to using classical feedback-based control structure, the enhanced IGCC regulatory control architecture reduces plant settling time and peak offshoots, achieves faster disturbance rejection, and promotes higher power ramp-rates. In addition, improvements in IGCC coordinated plant-wide control strategies for “Gasifier-Lead”, “GT-Lead” and “Plantwide” operation modes have been proposed and their responses compared. The paper is concluded with a brief discussion on the potential IGCC controller improvements resulting from using advanced process control, including model predictive control (MPC), as a supervisory control layer.

97 MATHEMATICS AND COMPUTING↗

Enhanced IGCC regulatory control and coordinated plant-wide control strategies for improving power ramp rates

As part of ongoing R&D activities at the National Energy Technology Laboratory’s (NETL) Advanced Virtual Energy Simulation Training & Research (AVESTAR™) Center, this paper highlights strategies for enhancing low-level regulatory control and system-wide coordinated control strategies implemented in a high-fidelity dynamic simulator for an Integrated Gasification Combined Cycle (IGCC) power plant with carbon capture. The underlying IGCC plant dynamic model contains 20 major process areas, each of which is tightly integrated with the rest of the power plant, making individual functionally-independent processes prone to routine disturbances. Single-loop feedback control although adequate to meet the primary control objective for most processes, does not take into account in advance the effect of these disturbances, making the entire power plant undergo large offshoots and/or oscillations before the feedback action has an opportunity to impact control performance. In this paper, controller enhancements ranging from retuning feedback control loops, multiplicative feed-forward control and other control techniques such as split-range control, feedback trim and dynamic compensation, applicable on various subsections of the integrated IGCC plant, have been highlighted and improvements in control responses have been given. Compared to using classical feedback-based control structure, the enhanced IGCC regulatory control architecture reduces plant settling time and peak offshoots, achieves faster disturbance rejection, and promotes higher power ramp-rates. In addition, improvements in IGCC coordinated plant-wide control strategies for “Gasifier-Lead”, “GT-Lead” and “Plantwide” operation modes have been proposed and their responses compared. The paper is concluded with a brief discussion on the potential IGCC controller improvements resulting from using advanced process control, including model predictive control (MPC), as a supervisory control layer.

20 FOSSIL-FUELED POWER PLANTS↗

Examination of Icing Induced Loss of Control and Its Mitigations

Factors external to the aircraft are often a significant causal factor in loss of control (LOC) accidents. In today s aviation world, very few accidents stem from a single cause and typically have a number of causal factors that culminate in a LOC accident. Very often the "trigger" that initiates an accident sequence is an external environment factor. In a recent NASA statistical analysis of LOC accidents, aircraft icing was shown to be the most common external environmental LOC causal factor for scheduled operations. When investigating LOC accident or incidents aircraft icing causal factors can be categorized into groups of 1) in-flight encounter with super-cooled liquid water clouds, 2) take-off with ice contamination, or 3) in-flight encounter with high concentrations of ice crystals. As with other flight hazards, icing induced LOC accidents can be prevented through avoidance, detection, and recovery mitigations. For icing hazards, avoidance can take the form of avoiding flight into icing conditions or avoiding the hazard of icing by making the aircraft tolerant to icing conditions. Icing detection mitigations can take the form of detecting icing conditions or detecting early performance degradation caused by icing. Recovery from icing induced LOC requires flight crew or automated systems capable of accounting for reduced aircraft performance and degraded control authority during the recovery maneuvers. In this report we review the icing induced LOC accident mitigations defined in a recent LOC study and for each mitigation describe a research topic required to enable or strengthen the mitigation. Many of these research topics are already included in ongoing or planned NASA icing research activities or are being addressed by members of the icing research community. These research activities are described and the status of the ongoing or planned research to address the technology needs is discussed

Reehorst, Andrew L.↗

The organization of perception and action in complex control skills

An attempt was made to describe the perceptual, cognitive, and action processes that account for highly skilled human performance in complex task environments. In order to study such a performance in a controlled setting, a laboratory task was constructed and three experiments were performed using human subjects. A general framework was developed for describing the organization of perceptual, cognitive, and action process.

Miller, Richard A.↗

Evaluation Report on "The Department's Unclassified Cyber Security Program"

Industry experts report that security challenges and threats are continually evolving as malicious activity has become more web-based and attackers are able to rapidly adapt their attack methods. In addition, the number of data breaches continues to rise. In an effort to mitigate and address threats and protect valuable information, the Department of Energy anticipated spending about $275 million in Fiscal Year (FY) 2009 to implement cyber security measures necessary to protect its information technology resources. These systems and data are designed to support the Department's mission and business lines of energy security, nuclear security, scientific discovery and innovation, and environmental responsibility. The Federal Information Security Management Act of 2002 (FISMA) provides direction to agencies on the management and oversight of information security risks, including design and implementation of controls to protect Federal information and systems. As required by FISMA, the Office of Inspector General conducts an annual independent evaluation to determine whether the Department's unclassified cyber security program adequately protects its information systems and data. This memorandum and the attached report present the results of our evaluation for FY 2009. The Department continued to make incremental improvements in its unclassified cyber security program. Our evaluation disclosed that most sites had taken action to address weaknesses previously identified in our FY 2008 evaluation report. They improved certification and accreditation of systems; strengthened configuration management of networks and systems; performed independent assessments; and, developed and/or refined certain policies and procedures. In addition, the Department instituted a centralized incident response organization designed to eliminate duplicative efforts throughout the Department. As we have noted in previous reports, the Department continued to maintain strong network perimeter defenses against malicious intruders and other externals threats. These are positive accomplishments. However, in our judgment, additional action is required to further enhance the Department's unclassified cyber security program and help reduce risks to its systems and data. For example, our current review identified opportunities for improvements in areas such as security planning and testing, systems inventory, access controls, and configuration management. In particular, we issued a number of findings at sites managed by the National Nuclear Security Administration (NNSA). We also identified weaknesses across various Department program elements. Issues that warrant further attention include: (1) Weaknesses such as outdated security plans and not completing annual security control self-assessments were identified at several sites; (2) The Department had not yet resolved systems inventory issues and had yet to deploy a complex-wide automated asset management tool to help track information technology resources and identify interfaces between systems or networks; (3) Although certain improvements had been made to enhance access controls, we noted deficiencies such as a lack of periodic account reviews and inadequate password management at a number of sites; and (4) Previously identified weaknesses in configuration management had been corrected, however, we found problems related to weak administrator account settings and failure to install software patches, as well as incomplete implementation of the Federal Desktop Core Configuration. These internal control weaknesses existed, at least in part, because certain cyber security roles and responsibilities were not clearly delineated. Program officials also had not effectively performed monitoring and review activities essential for evaluating the adequacy of cyber security performance. In some cases, officials had not ensured that weaknesses discovered during audits and other evaluations were recorded and tracked to resolution in the organizations' Plans of Action and Milestones. Our testing disclosed that about 39 percent of existing corrective action milestones had missed estimated remediation dates, with many exceeding planned completion dates by at least one year. As a consequence, the risk of compromise to the Department's information and systems remained higher than necessary. To assist the continuing efforts to improve, we made several recommendations designed to help the Department's managers to strengthen the unclassified cyber security program and, thereby, protect its computer resources from unauthorized modification, loss, or disclosure of information. Due to security considerations, information on specific vulnerabilities and locations has been omitted from this report. Management officials at the sites evaluated were provided with detailed information regarding identified vulnerabilities, and, in many instances, initiated corrective actions.

99 GENERAL AND MISCELLANEOUS↗

Consideration of dynamic loads on the vertical tail by the theory of flat yawing maneuvers

Dynamic yawing effects on vertical tail loads are considered by a theory of flat yawing maneuvers. A comparison is shown between computed loads and the loads measured in flight in a fighter airplane. The dynamic effects were investigated on a large flying boat for both an abrupt rudder deflection and a sinusoidal rudder deflection. Only a moderate amount of control deflection was found to be necessary to attain the ultimate design load on the tail. In order to take into account dynamic effects in design, specifications of yawing maneuverability or control movement are needed.

Boshar, John↗