Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centroid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Giant resonances in 40,48 Ca, 68 Ni, 90 Zr, 116 Sn, 144 Sm, and 208 Pb

We present results of centroid energies E CEN , of the isoscalar (T = 0) and isovector (T = 1) giant resonances of multipolarities L = 0–3 in 40,48 Ca, 68 Ni, 90 Zr, 116 Sn, 144 Sm, and 208 Pb, calculated within the fully self-consistent Hartree-Fock-based random phase approximation theory, using 33 different Skyrme-type effective nucleon-nucleon interactions of the standard form commonly adopted in the literature. We compare the results of our theoretical calculations with the available experimental data. We also study the sensitivity of the calculated ECEN to physical properties of nuclear matter (NM), such as effective mass m*/m, nuclear matter incompressibility coefficient KNM, enhancement coefficient κ of the energy weighted sum rule for the isovector giant dipole resonance and symmetry energy at saturation density, associated with the Skyrme interactions used in the calculations. Furthermore, this is done by determining the Pearson linear correlation coefficient between the calculated ECEN and a certain NM property. Constraining the values of the NM properties, by comparing the calculated values of E CEN to the experimental data, we find that interactions associated with the values of K NM = 210–240 MeV and κ = 0.25–0.70 best reproduce the experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evolution of E 2 strength in the rare-earth isotopes Hf 174 , 176 , 178 , 180

Mean lifetimes of yrast states of the isotopes 174,176,178,180 Hf have been measured using fast-electronic scintillation timing. Excited states of 174,176,178 Hf were populated via β decay, while 180 Hf was populated via Coulomb excitation. The lifetimes of the 2 + 1 and 4 + 1 states of all isotopes and the lifetimes of the 6 + 1 states of 174,178 Hf were measured, using the slope and the centroid shift methods. The mean lifetime, τ(4 + 1 ) = 85 (13) ps, of 178 Hf has been determined for the first time. In addition, the mean lifetimes of the 2 – 1 and the 3 – 1 states of 176 Hf have been determined. Systematic uncertainties on the evolution of data as a function of neutron number were reduced by using the same setup for all the isotopes of interest. The data are in agreement with other recent lifetime measurements where available and shows a shift of the maximum of collectivity for the Hf isotopic chain from neutron midshell at N = 104 to N = 100.

150 ≤ A ≤ 189↗

Gravitational lensing by rotating naked singularities

We model massive compact objects in galactic nuclei as stationary, axially symmetric naked singularities in the Einstein-massless scalar field theory and study the resulting gravitational lensing. In the weak deflection limit we study analytically the position of the two weak field images, the corresponding signed and absolute magnifications as well as the centroid up to post-Newtonian order. We show that there are static post-Newtonian corrections to the signed magnification and their sum as well as to the critical curves, which are functions of the scalar charge. The shift of the critical curves as a function of the lens angular momentum is found, and it is shown that they decrease slightly for the weakly naked and vastly for the strongly naked singularities with the increase of the scalar charge. The pointlike caustics drift away from the optical axis and do not depend on the scalar charge. In the strong deflection limit approximation, we compute numerically the position of the relativistic images and their separability for weakly naked singularities. All of the lensing quantities are compared to particular cases as Schwarzschild and Kerr black holes as well as Janis-Newman-Winicour naked singularities.

79 ASTRONOMY AND ASTROPHYSICS↗

Bobbing and kicks in electromagnetism and gravity

We study systems analogous to binary black holes with spin in order to gain some insight into the origin and nature of 'bobbing' motion and 'kicks' that occur in this system. Our basic tool is a general formalism for describing the motion of extended test bodies in an external electromagnetic field in curved spacetime and possibly subject to other forces. We first show that bobbing of exactly the type as observed in numerical simulations of the binary black hole system occurs in a simple system consisting of two spinning balls connected by an elastic band in flat spacetime. This bobbing may be understood as arising from the difference between a spinning body's 'lab frame centroid' and its true center of mass, and is purely 'kinematical' in the sense that it will appear regardless of the forces holding two spinning bodies in orbit. Next, we develop precise rules for relating the motion of charged bodies in a stationary external electromagnetic field in flat spacetime with the motion of bodies in a weakly curved stationary spacetime. We then consider the system consisting of two orbiting charges with magnetic dipole moment and spin at a level of approximation corresponding to 1.5 post-Newtonian order. Here we find that considerable amounts of momentum are exchanged between the bodies and the electromagnetic field; however, the bodies store this momentum entirely as ''hidden'' mechanical momentum, so that the interchange does not give rise to any net bobbing. The net bobbing that does occur is due solely to the kinematical spin effect, and we therefore argue that the net bobbing of the electromagnetic binary is not associated with possible kicks. We believe that this conclusion holds in the gravitational case as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discretization of the induced-charge boundary integral equation.

Boundary-element methods (BEMs) for solving integral equations numerically have been used in many fields to compute the induced charges at dielectric boundaries. In this paper, we consider a more accurate implementation of BEM in the context of ions in aqueous solution near proteins, but our results are applicable more generally. The ions that modulate protein function are often within a few angstroms of the protein, which leads to the significant accumulation of polarization charge at the protein-solvent interface. Computing the induced charge accurately and quickly poses a numerical challenge in solving a popular integral equation using BEM. In particular, the accuracy of simulations can depend strongly on seemingly minor details of how the entries of the BEM matrix are calculated. We demonstrate that when the dielectric interface is discretized into flat tiles, the qualocation method of Tausch et al. [IEEE Trans Comput.-Comput.-Aided Des. 20, 1398 (2001)] to compute the BEM matrix elements is always more accurate than the traditional centroid-collocation method. Qualocation is not more expensive to implement than collocation and can save significant computational time by reducing the number of boundary elements needed to discretize the dielectric interfaces.

36 MATERIALS SCIENCE↗

First Measurement of the Giant Monopole and Quadrupole Resonances in a Short-Lived Nucleus: {sup 56}Ni

The isoscalar giant monopole resonance (GMR) and giant quadrupole resonance (GQR) have been measured in the {sup 56}Ni unstable nucleus by inducing the {sup 56}Ni(d,d{sup '}) reaction at 50A MeV in the Maya active target at the GANIL facility. The GMR and GQR centroids are measured at 19.3{+-}0.5 MeV and 16.2{+-}0.5 MeV, respectively. The corresponding angular distributions are extracted from 3 deg. to 7 deg. A multipole decomposition analysis using distorted wave Born approximation with random phase approximation transition densities shows that both the GMR and the GQR exhaust a large fraction of the energy-weighted sum rule. The demonstration of this new method opens a broad range of giant resonance studies at intermediate-energy radioactive beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Measurement of the Mass of the h{sub c}({sup 1}P{sub 1}) State of Charmonium

A precision measurement of the mass of the h{sub c}({sup 1}P{sub 1}) state of charmonium has been made using a sample of 24.5x10{sup 6} {psi}(2S) events produced in e{sup +}e{sup -} annihilation at the Cornell Electron Storage Ring (CESR). The reaction used was {psi}(2S){yields}{pi}{sup 0}h{sub c}, {pi}{sup 0}{yields}{gamma}{gamma}, h{sub c}{yields}{gamma}{eta}{sub c}, and the reaction products were detected in the CLEO-c detector. Data have been analyzed both for the inclusive reaction and for the exclusive reactions in which {eta}{sub c} decays are reconstructed in 15 hadronic decay channels. Consistent results are obtained in the two analyses. The averaged results of the present measurements are M(h{sub c})=3525.28{+-} 0.19(stat.){+-}0.12(syst.) MeV, and B({psi}(2S){yields}{pi}{sup 0}h{sub c})xB(h{sub c}{yields}{gamma}{eta}{sub c})=(4.19{+-}0.32{+-}0.45)x10{sup -4}. Using the {sup 3}P{sub J} centroid mass, {delta}M{sub hf}(1P){identical_to}<M({chi}{sub cJ})>-M(h{sub c})=+0.02{+-}0.19{+-}0.13 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dislocation Structure and Mobility in hcp He 4

We assess the core structure and mobility of the screw and edge basal-plane dislocations in hcp 4 He using path-integral Monte Carlo simulations. Our findings provide key insights into recent interpretations of giant plasticity and mass flow junction experiments. First, both dislocations are dissociated into nonsuperfluid Shockley partial dislocations separated by ribbons of stacking fault, suggesting that they are unlikely to act as one-dimensional channels that may display Lüttinger-liquid-like behavior. Second, the centroid positions of the partial cores are found to fluctuate substantially, even in the absence of applied shear stresses. This implies that the lattice resistance to motion of the partial dislocations is negligible, consistent with the recent experimental observations of giant plasticity. Our results indicate that both the structure of the partial cores and the zero-point fluctuations play a role in this extreme mobility.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure and Reactions of Be 11 : Many-Body Basis for Single-Neutron Halo

The exotic nucleus 11 Be has been extensively studied and much experimental information is available on the structure of this system. Treating, within the framework of empirically renormalised nuclear field theory in both configuration and 3D-space, the mixing of bound and continuum single-particle states through the coupling to collective particle-hole (p,h) and pairing vibrations of the 10 Be core, as well as Pauli principle acting not only between the particles explicitly considered and those participating in the collective states, but also between fermions involved in two-phonon virtual states it is possible, for the first time, to simultaneously and quantitatively account for the energies of the 1/2 + ,1/2 - low-lying states, the centroid and line shape of the 5/2 + resonance, the one-nucleon stripping and pickup absolute differential cross sections involving 11 Be as either target or residual nucleus, and the dipole transitions connecting the 1/2 + and 1/2 - parity inverted levels as well as the charge radius, thus providing a unified and exhaustive characterisation of the many-body effects which are at the basis of this paradigmatic one-neutron halo system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses

X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. As a result, this was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw and by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrabright Electron Bunch Injection in a Plasma Wakefield Driven by a Superluminal Flying Focus Electron Beam

Here, we propose a new method for self-injection of high-quality electron bunches in the plasma wakefield structure in the blowout regime utilizing a “flying focus” produced by a drive beam with an energy chirp. In a flying focus the speed of the density centroid of the drive bunch can be superluminal or subluminal by utilizing the chromatic dependence of the focusing optics. We first derive the focal velocity and the characteristic length of the focal spot in terms of the focal length and an energy chirp. We then demonstrate using multidimensional particle-in-cell simulations that a wake driven by a superluminally propagating flying focus of an electron beam can generate GeV-level electron bunches with ultralow normalized slice emittance (~30 nm rad), high current (~17 kA), low slice energy spread (~0.1%), and therefore high normalized brightness (> 10 19 A/ m 2 /rad 2 ) in a plasma of density ~10 19 cm –3 . The injection process is highly controllable and tunable by changing the focal velocity and shaping the drive beam current. Nearterm experiments at FACET II where the capabilities to generate tens of kA, < 10 fs drivers are planned, could potentially produce beams with brightness near 10 20 A / m 2 / rad 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Barrier Distributions Derived from Quasielastic Backscattering of {sup 48}Ti, {sup 54}Cr, {sup 56}Fe, {sup 64}Ni, and {sup 70}Zn Projectiles on a {sup 208}Pb Target

In order to study the nucleus-nucleus interaction in Pb-based cold fusion, we have measured excitation functions for quasielastic scattering of {sup 48}Ti, {sup 54}Cr, {sup 56}Fe, {sup 64}Ni, and {sup 70}Zn projectiles on a {sup 208}Pb target at backward angles. The barrier distributions were derived from the first derivative of measured quasielastic scattering cross sections relative to the Rutherford scattering cross section. The centroids of the barrier distributions show a deviation from several predicted barrier heights toward the low energy side. The shape of the barrier distributions is well reproduced by the results of a coupled-channel calculation taking account of the coupling effects of two phonon excitations of the quadrupole vibration for the projectiles and of the octupole vibration for the {sup 208}Pb target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

(2,2-Bipyridyl)bis(eta5-1,2,3,4,5-pentamethylcyclopentadienyl)Strontium(II)

In the title compound, the Sr-N distances are 2.624 (3) and 2.676 (3) Angstroms. The Sr-centroid distances are 2.571 and 2.561 Angstroms. The N-C-C-N torsion angle in the bipyridine ligand is 2.2 (4){sup o}. Interestingly, the bipyridine ligand is tilted. The angle between the plane defined by Sr1, N1 and N2 and the plane defined by the 12 atoms of the bipyridine ligand is 10.7{sup o}.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Precision lattice parameter determination from transmission diffraction of thick specimens with irregular cross sections

Accurate determination of lattice parameters from X-ray diffraction requires that the diffraction angles be measured very precisely, and significant errors result if the sample–detector separation differs from that assumed. Transmission diffraction from bones, which have a complex cross section and must be left intact, is a situation where this separation is difficult to measure and it may differ from position to position across the specimen. Here, this article describes a method for eliminating the effect of variable sample cross section. Diffraction patterns for each position on the specimen are collected before and after 180° rotation about an axis normal to the cross section of interest. This places the centroid of the diffracting mass at the center of rotation and provides the absolute lattice parameters from the average apparent lattice parameters at the two rotation angles. Diffraction patterns were collected across the cross section of three specimens: a 3D-printed elliptical cylinder of Hyperelastic Bone (HB), which is composed primarily of synthetic hydroxyapatite (hAp), a 3D-printed HB model of the second metacarpal bone (Mc2), and a modern human Mc2 containing nanocrystalline carbonated apatite (cAp). Rietveld refinement was used to determine precise unit-cell parameters a apparent and c apparent for each pattern of each scan, and these values determined the actual average < a > and < c > for each sample. In conclusion, the results indicate that the 0°/180° rotation method works well enough to uncover variations approaching 1 × 10 -3 Å in cAp unit-cell parameters in intact bones with irregular cross sections.

36 MATERIALS SCIENCE↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation↗

Qualitative and quantitative validation of the SINBAD code on complex HPGe gamma-ray spectra

Radionuclides identification and quantification is a serious concern for many applications as safety or security of nuclear power plant or fuel cycle facility, CBRN risk identification, environmental radioprotection and waste measurements. High resolution gamma-ray spectrometry based on HPGe detectors is a performing solution for all these topics. During last decades, a great number of software has been developed to improve gamma spectra analysis. However, some difficulties remain in the analysis when photoelectric peaks are folded together with a high ratio between theirs amplitudes, when the Compton background is much larger compared to the signal of a single peak and when spectra are composed of a great number of peaks. This study deals with the comparison between conventional methods in radionuclides identification and quantification and the code called SINBAD ('Spectrometrie par Inference Non parametrique Bayesienne Deconvolutive'). For many years, SINBAD has been developed by CEA LIST for unfolding complex spectra from HPGe detectors. Contrary to conventional methods using fitting procedures, SINBAD uses a probabilistic approach with Bayesian inference to describe spectrum data. This conventional fitting method founded for example in Genie 2000 is compared with the nonparametric SINBAD approach regarding some key figures of merit as the peak centroid evaluation (identification) and peak surface evaluation (quantification). Unfriendly cases are studied for nuclides detection with closed gamma-rays energies and high photoelectric peak intensity differences. Tests are performed with spectra from the International Atomic Energy Agency (IAEA) for gamma spectra analysis software benchmark and with spectra acquired at the laboratory. Results show that SINBAD and Genie 2000 performances are quite similar with sometimes best results for SINBAD with the important difference that to achieve same performances the nonparametric method is user-friendly compared to the conventional method which need an expert parameters adjustment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗