Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cell Line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Analog Nonvolatile Computer Memory Circuits

In nonvolatile random-access memory (RAM) circuits of a proposed type, digital data would be stored in analog form in ferroelectric field-effect transistors (FFETs). This type of memory circuit would offer advantages over prior volatile and nonvolatile types: In a conventional complementary metal oxide/semiconductor static RAM, six transistors must be used to store one bit, and storage is volatile in that data are lost when power is turned off. In a conventional dynamic RAM, three transistors must be used to store one bit, and the stored bit must be refreshed every few milliseconds. In contrast, in a RAM according to the proposal, data would be retained when power was turned off, each memory cell would contain only two FFETs, and the cell could store multiple bits (the exact number of bits depending on the specific design). Conventional flash memory circuits afford nonvolatile storage, but they operate at reading and writing times of the order of thousands of conventional computer memory reading and writing times and, hence, are suitable for use only as off-line storage devices. In addition, flash memories cease to function after limited numbers of writing cycles. The proposed memory circuits would not be subject to either of these limitations. Prior developmental nonvolatile ferroelectric memories are limited to one bit per cell, whereas, as stated above, the proposed memories would not be so limited. The design of a memory circuit according to the proposal must reflect the fact that FFET storage is only partly nonvolatile, in that the signal stored in an FFET decays gradually over time. (Retention times of some advanced FFETs exceed ten years.) Instead of storing a single bit of data as either a positively or negatively saturated state in a ferroelectric device, each memory cell according to the proposal would store two values. The two FFETs in each cell would be denoted the storage FFET and the control FFET. The storage FFET would store an analog signal value, between the positive and negative FFET saturation values. This signal value would represent a numerical value of interest corresponding to multiple bits: for example, if the memory circuit were designed to distinguish among 16 different analog values, then each cell could store 4 bits. Simultaneously with writing the signal value in the storage FFET, a negative saturation signal value would be stored in the control FFET. The decay of this control-FFET signal from the saturation value would serve as a model of the decay, for use in regenerating the numerical value of interest from its decaying analog signal value. The memory circuit would include addressing, reading, and writing circuitry that would have features in common with the corresponding parts of other memory circuits, but would also have several distinctive features. The writing circuitry would include a digital-to-analog converter (DAC); the reading circuitry would include an analog-to-digital converter (ADC). For writing a numerical value of interest in a given cell, that cell would be addressed, the saturation value would be written in the control FFET in that cell, and the non-saturation analog value representing the numerical value of interest would be generated by use of the DAC and stored in the storage FFET in that cell. For reading the numerical value of interest stored in a given cell, the cell would be addressed, the ADC would convert the decaying control and storage analog signal values to digital values, and an associated fast digital processing circuit would regenerate the numerical value from digital values.

MacLeod, Todd↗

Hyperfine structure of excited states and quadrupole moment of Ne-21 using laser-induced line-narrowing techniques.

Observation results are presented on the optical hyperfine structure in Ne-21 obtained with the aid of laser-induced line-narrowing techniques. The output from a long stabilized single-mode 1.15-micron He-Ne laser focused into an external sample cell containing Ne-21 was used in implementing these techniques. Their applicability is demonstrated for optical hyperfine structure observation in systems whose features are ordinarily masked by Doppler broadening.

Ducas, T. W.↗

Photonic Diagnostic Technique For Thin Photoactive Films

Photonic diagnostic technique developed for use in noninvasive, rapid evaluation of thin paraelectric/ferroelectric films. Method proves useful in basic research, on-line monitoring for quality control at any stage of fabrication, and development of novel optoelectronic systems. Used to predict imprint-prone memory cells, and to study time evolution of defects in ferroelectric memories during processing. Plays vital role in enabling high-density ferroelectric memory manufacturing. One potential application lies in use of photoresponse for nondestructive readout of polarization memory states in high-density, high-speed memory devices. In another application, extension of basic concept of method makes possible to develop specially tailored ferrocapacitor to act as programmable detector, wherein remanent polarization used to modulate photoresponse. Large arrays of such detectors useful in optoelectronic processing, computing, and communication.

Thakoor, Sarita↗

Active Control of Inlet Noise on the JT15D Turbofan Engine

This report presents the key results obtained by the Vibration and Acoustics Laboratories at Virginia Tech over the year from November 1997 to December 1998 on the Active Noise Control of Turbofan Engines research project funded by NASA Langley Research Center. The concept of implementing active noise control techniques with fuselage-mounted error sensors is investigated both analytically and experimentally. The analytical part of the project involves the continued development of an advanced modeling technique to provide prediction and design guidelines for application of active noise control techniques to large, realistic high bypass engines of the type on which active control methods are expected to be applied. Results from the advanced analytical model are presented that show the effectiveness of the control strategies, and the analytical results presented for fuselage error sensors show good agreement with the experimentally observed results and provide additional insight into the control phenomena. Additional analytical results are presented for active noise control used in conjunction with a wavenumber sensing technique. The experimental work is carried out on a running JT15D turbofan jet engine in a test stand at Virginia Tech. The control strategy used in these tests was the feedforward Filtered-X LMS algorithm. The control inputs were supplied by single and multiple circumferential arrays of acoustic sources equipped with neodymium iron cobalt magnets mounted upstream of the fan. The reference signal was obtained from an inlet mounted eddy current probe. The error signals were obtained from a number of pressure transducers flush-mounted in a simulated fuselage section mounted in the engine test cell. The active control methods are investigated when implemented with the control sources embedded within the acoustically absorptive material on a passively-lined inlet. The experimental results show that the combination of active control techniques with fuselage-mounted error sensors and passive control techniques is an effective means of reducing radiated noise from turbofan engines. Strategic selection of the location of the error transducers is shown to be effective for reducing the radiation towards particular directions in the farfield. An analytical model is used to predict the behavior of the control system and to guide the experimental design configurations, and the analytical results presented show good agreement with the experimentally observed results.

Smith, Jerome P.↗

Implementation of Self-Align Local Poly Interconnection on 0.25 Micron Flash Memory

For ETOX Flash technology. the self-aligned source module plays a critical role in minimizing cell size. For advanced Flash technology using the shallow-trench isolation (STI) scheme, however, it is difficult to form a stable source line. The Flash process in this experiment features an ETOX structure and with SIN spacer. Poly-Si (implanted poly) is used as the local interconnection material connecting the source line and was successfully implemented in the ETOX flash array in this paper.

C H Lee↗

Precise Laboratory Measurement of LINR Frequencies Useful to Studies of Star and Planet Formation

In March 2002, we began a program in laboratory spectroscopy to provide accurate molecular line frequencies essential to studies of the motions and abundances in star-froming dense cores and planet-forming circumstellar disks. The CN radical is one of the most important tracers of dynamical motions in protoplanetary disks around low mass pre-main sequence stars. The millimeter-wave spectrum of CN consists of rotational transitions every 113 GHz which are split into many resolved hyperfine components. Very narrow and fairly bright lines of SiO in the ground vibrational state have been observed in regions where protostellar outflows interact with the cold ambient gas. In support of future astronomical observations in these regions, 10 successive rotational lines in the ground vibrational state of Si0 between 86 and 500 GHz, and two lines near 800 GHz were measured in the laboratory to an accuracy of a few kHz. A negative glow discharge spectrometer that will allow the determination of accurate line frequencies of molecular ions has been constructed. We are presently modifying the method for cooling the magnetic field enhanced (negative glow) discharge cell to 77 K.

Myers, Philip C.↗

Design and Performance Assessment of a Stable Astigmatic Herriott Cell for Trace Gas Measurements on Airborne Platforms

The present paper discusses a new, more stable, astigmatic Herriott cell employing carbon fiber stabilizing rods. Laboratory tests using a near-IR absorption feature of CO at 1564.168-nm revealed a factor of two improvement in measurement stability compared with the present commercial design when the sampling pressure was changed by +/-2 Torr around 50 Torr. This new cell should significantly enhance our efforts to measure trace gases employing pathlengths of 100 to 200-meters on airborne platforms with minimum detectable line center absorbances of less than 10(exp -6).

Dyroff, Christoph↗

Enabling Single Cell Research in Hollow Hydrogel Microparticles

Studying biology at the single cell level enables novel discoveries through ultra-high throughput identification and isolation of rare cells and interesting subpopulations. Encapsulation of single cells in hollow hydrogel microparticles, or PicoShells, enables easy visualization, manipulation, and assaying of single cells. The PicoShell’s porous hydrogel shell allows diffusion of nutrients and wastes into and out of the hollow liquid core, allowing uninhibited cell growth. The porous shell also allows diffusion of assay reagents, enabling solution changes, and multi-step assays. Finally, single cells and their progeny can be tracked through time, for example to measure single cell growth rates. However, PicoShells are fabricated using microfluidic techniques, which require specialized expertise, equipment, and facilities. This limits PicoShell’s widespread utility for single cell biology. For Saccharomyces cerevisiae and other desiccation-tolerant microbes, desiccating PicoShells containing cells of interest offers a solution, enabling those without microfluidic capabilities to obtain dried, shelf-stable PicoShells containing their cells of interest from a specialized microfluidics facility. Researchers could then rehydrate the PicoShells and perform their single cell assays, bypassing the microfluidic steps. Desiccated PicoShells could also be flown in space, where desiccation is already a common practice for microbes (i.e. BioSentinel and BioNutrients), bringing single cell analysis capabilities to space. In this work, we develop a method to desiccate PicoShells containing S. cerevisiae while maintaining characteristics similar to fresh, non-desiccated PicoShells. We show good microparticle morphology and hydrogel pore size as well as high yeast viability in line with previous studies. We also demonstrate sorting of a fast-growing yeast population using size-based filtration, as S. cerevisiae in PicoShells are able to physically stretch the microparticle as they grow, increasing the PicoShell diameter. These efforts contribute to the feasibility of leveraging microparticle PicoShells for single cell space biology research on Earth and in space.

Simon Ng↗

Light shift and light broadening in the Rb-87 maser.

A description of measurements of light-shift and light-broadening parameters for an Rb-87 maser operating between the field independent levels is reported. A parallel study of the spectral profile of the D1 pumping line is described. Comparison between the experimental results and theoretical calculations, taking into account the spatial inhomogeneity of the pumping light in the absorption cell, is presented.

Busca, G.↗

The preliminary design of an orbiting observatory - The Space Telescope

The systems and subsystems of the Space Telescope proposed for an orbiting observatory to be launched by the Space Shuttle in the 1980s are described. The structural design is simple and based on existing technologies for high reliability. Provisions are made for on-orbit servicing and maintenance. All deployable appendages are designed for manual override to insure retrieval and return of the Space Telescope to earth for major refurbishing, which should occur at intervals of not less than six years. Low performance risk, passive techniques are used in the thermal control subsystem to provide a cold-biased design with thermostatically controlled heaters to adjust temperature. The electrical power system utilizes NASA Standard Hardware - 50 ampere hour nickel-cadmium battery cells, a standard power regulator unit, and a flight-proven flexible rollup solar array with high-efficiency (12.5 per cent) silicon solar cells. The communication subsystem is designed for compatibility with the Tracking and Data Relay Satellite System. The pointing control system will have a maximum line of sight variation of 0.007 arc seconds. The telescope optics are a Ritchey-Chretien version of the Cassegrain configuration.

Timmons, K. P.↗

A gas filter correlation monitor for CO, CH4, and HCl

A fast response instrument for monitoring the atmospheric constituents CO, CH4, and HCl, using a modified nondispersive infrared technique, was designed, assembled, and tested. This gas filter correlation method uses a sample of gas to provide a selective filter for radiation absorbed in a gas mixture containing the specified gas. Depending on the spectral line broadening, temperature, and optical depth of the gas selected, exceptionally high spectral resolution may be attained. A description of the single beam rotating cell system and its specific application is presented along with the signal processing circuit. Calibrations of the instrument show that the technique can be used to measure CO, CH4, and HCl concentrations as small as 5 ppm-m. A field version was employed to measure diurnal variations of CO and CH4 and the interfering effects of other atmospheric gases were analyzed.

Sebacher, D. I.↗

The automated array assembly task of the low-cost silicon solar array project, phase 2

Several specific processing steps as part of a total process sequence for manufacturing silicon solar cells were studied. Ion implantation was identified as the preferred process step for impurity doping. Unanalyzed beam ion implantation was shown to have major cost advantages over analyzed beam implantation. Further, high quality cells were fabricated using a high current unanalyzed beam. Mechanically masked plasma patterning of silicon nitride was shown to be capable of forming fine lines on silicon surfaces with spacings between mask and substrate as great as 250 micrometers. Extensive work was performed on advances in plated metallization. The need for the thick electroless palladium layer was eliminated. Further, copper was successfully utilized as a conductor layer utilizing nickel as a barrier to copper diffusion into the silicon. Plasma etching of silicon for texturing and saw damage removal was shown technically feasible but not cost effective compared to wet chemical etching techniques.

Coleman, M. G.↗

Neutral buoyancy test results of a deployable space beam

Large erectable and deployable space structures have been studied extensively in the past few years with a view toward usage in the near future for space platforms. The paper covers in particular the operational testing of a double-cell, double-folding cubic aluminum module at the Marshall Space Flight Center Neutral Buoyancy Simulator. Joining methods, deployment kinematics, configurations and operation time lines were analyzed using the Shuttle Remote Manipulator System (RMS) and EVA crewmen. Results of the test were considered successful, with crew tasks accomplished and the structural design adequate for flight design.

Stokes, J. W.↗

Detection of rotating thunderstorms using satellite imagery

In the case of the Carolina tornadoes, researchers prepared visible and IR GOES imagery covering the period 2000 Z when the storm entered South Carolina from Georgia until it exited North Carolina at 0200 Z into Virginia. The GOES IR imagery clearly demonstrated that this storm was imbedded in a continuously propagating mesolow with a well defined cold dome. The ground damage track paralleled exactly with the cold dome throughout the storm's life across the Carolinas. There were no advanced very high resolution radiometer (AVHRR) data during the period to allow researchers to inspect the cloud top for warm temperature anomalies. The Carolina storm did exhibit rightward deviating outflow which was oriented about 60 degrees to the 300 mb streamlines. The tornadoes of April 27, 1984 were part of a tornado producing cold front which stretched from Oklahoma to Minnesota. As the front moved eastward it touched off numerous tornadoes in eastern Wisconsin. GOES imagery for this data was prepared and it was strikingly clear that all along the North-South oriented squall line, the individual tunderstorms had cirrus plumes which had remarkable right deviation to the upper air flow. Unlike the Carolina long track supercell cell-mesolow system, these storms were isolated individual thunderstorms which touched off at least 16 tornadoes in eastern Wisconsin stretching from the Milwaukee area on the south to Vilas County in the north. The monster tornado of June 8, 1984 which leveled 90 percent of the village of Barneveld, Wisconsin and killed 9 persons is also discussed.

Anderson, C. E.↗

Nickel-hydrogen separator development

The separator technology is a critical element in the nickel-hydrogen (Ni-H2) systems. Previous research and development work carried out at NASA Lewis Research Center has determined that separators made from zirconium oxide (ZrO2) and potassium titanate (PKT) fibers will function satisfactorily in Ni-H2 cells without exhibiting the problems associated with the asbestos separators. A program has been established to transfer the separator technology into a commercial production line. A detailed plan of this program will be presented and the preliminary results will be discussed.

Gonzalez-Sanabria, O. D.↗

Recent developments in refractive concentrators for space photovoltaic power systems

Since SPRAT 11, significant progress has been made in the development of refractive concentrator elements and components designed specifically for space applications. The status of the mini-dome Fresnel lens concentrator array is discussed and then the results of work recently completed in the area of prismatic cell covers for concentrator systems are summarized. This is followed by a brief discussion of some work just starting in the area of line-focus refractive concentrators for space.

Piszczor, Michael F.↗

Enhanced Microbial Detection Capabilities by a Rapid Portable Instrument

We present data describing a progression of continuing technology development - from expanding the detection capabilities of the current PTS unit to re-outfitting the instrument with a protein microarray increasing the number of detectable compounds. To illustrate the adaptability of the cartridge format, on-orbit operations data from the ISS demonstrate the detection of the fungal cell wall compound beta-glucan using applicable LOCAD-PTS cartridges. LOCAD-PTS is a handheld device consisting of a spectrophotometer, an onboard pumping mechanism, and data storage capabilities. A suite of interchangeable cartridges lined with four distinct capillaries allow a hydrated sample to mix with necessary reagents in the channels before being pumped to the optical well for spectrophotometric analysis. The reagents housed in one type of cartridge trigger a reaction based on the Limulus Amebocyte Lysate (LAL) assay, which results in the release of paranitroaniline dye. The dye is measured using a 395 nm filter. The LAL assay detects the Gram-negative bacterial cell wall molecule, endotoxin or lipopolysaccharide (LPS). The more dye released, the greater the concentration of endotoxin in the sample. Sampling, quantitative analysis, and data retrieval require less than 20 minutes. This is significantly faster than standard culture-based methods, which require at least a 24 hour incubation period.Using modified cartridges, we demonstrate the detection of Gram negative bacteria with protein microarray technology. Additionally, we provide data from multiple field tests where both standard and advanced PTS technologies were used. These tests investigate the transfer of target microbial molecules from one surface to another. Collectively, these data demonstrate that the new cartridges expand the number of compounds detected by LOCAD-PTS, while maintaining the rapid, in situ analysis characteristic of the instrument. The unit provides relevant data for verifying sterile sample collection protocols, which are critical for conducting accurate scientific experiments during future missions to the Moon and Mars.

Morris, Heather↗