Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Corrosion Analysis of 121103072 (SAVY-4000)

A surveillance feedlist for fiscal year (FY) 2022 was developed with the intent to target containers with contents known to generate corrosive gasses. One SAVY-4000 (hereafter “SAVY”) container with a serial number 121103072 was selected due to the reasonable wattage and known molten salt extraction (MSE) material corrosive behavior. The material was measured at 3.08 W with approximately 200 g of material placed inside of the SAVY for 6.07 years. The inner packaging configuration included a ¼ Qt stainless steel slip top inner container and a sPVC bag-out bag enclosing the inner container. Visual observations of the container during retrieval revealed several concerning features on the exterior of the container, notably on the lid. Fig. 1 shows the container lid along with an inset image further magnifying the features of interest. The corroded tamper indicating device (TID) wire and the corroded radioactive material tag wire indicated that corrosive gas species for steel were produced during storage. Although the TID wire and rad tag wire are not the same composition as the SAVY body and lid, these are often used as an indicator of potential corrosion inside of the SAVY container. The oxide residing inside of the filter holes and significant buildup around one hole provided further evidence supporting the presence of corrosive species inside of the container.

36 MATERIALS SCIENCE↗

Multi-Parameter Optical Fiber for Distributed Sensing of Humidity, CH4, CO2, and Corrosion

This work describes the use of the optical fiber sensor (OFS) for successful monitoring of humidity, CH4, and CO2 based on the strain produced along the single-mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases onto the commercially available polyacrylate coated jacketed portion of the fiber resulting in a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different relative humidity (RH) conditions. The strain response of the SMF under various mixed gas composition and different RH conditions were also measured and made calibration curves accordingly. Linear regression and principal component analysis of the strain datasets provided deconvolution of the impact of strain from H2O, N2, CH4, and CO2. Additionally, modified OFS comprised of the Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion of Fe occurs. Also, corrosion of Fe was studied under soil by installing the fiber in soil with protective measures which would prevent the sensor being mechanically disturbed or broken during installation. The corrosion rates were studied by monitoring the rate at which the intensity of backscattered light amplitude attains a steady state value when complete corrosion of Fe with a specific coating thickness occurs.

Mainali, Badri↗

Applied Research and Development to Support Open Water Testing at PacWave – Task 5: Development of additively manufactured, functionally graded, corrosion resistant clads for wave energy applications

In this task, we focused on developing corrosion-resistant claddings for wave energy applications. Wave energy systems are exposed to saline conditions, which are corrosive to many metallic structural materials (e.g., carbon steel). Corrosion-resistant (stainless) steels are typically alloyed with >18% chromium (Cr) and >8% nickel (Ni), which dramatically raises material costs and can hinder the development of wave energy systems; thus, coatings are a necessary corrosion protection method for most. Non-metallic coatings (paint, epoxy) have shorter service lives, limited resistance to mechanical stress and wear, plus additional costs of inspection and eventual replacement. Therefore, overlay stainless steel (SS) claddings have a cost-effective use case for protecting components from corrosion, particularly for those that may be subject to mechanical stress / wear and with long service lives.

16 TIDAL AND WAVE POWER↗

Degradation science: Integrating modeling and experiments to predict localized corrosion processes (Annual Progress Report)

Additively manufactured (AM) eutectic high-entropy alloys (EHEAs), such as nano-lamellar AlCoCrFeNi 2.1 , have excellent strength, ductility, and wear resistance even at elevated temperatures, but their corrosion behavior in aggressive acids at different length scales remain poorly understood. This work investigates the corrosion behavior of laser powder bed–fused (L-PBF) AlCoCrFeNi 2.1 as a function of annealing temperatures, probing degradation mechanisms from nanoscopic to macroscopic length scales. The alloy is dual phase consisting of a ductile FCC L1 2 phase and a high-strength BCC B2 phase. Rapid solidification during L-PBF produces a far-from-equilibrium nano-lamellar structure with nearly homogeneous elemental distribution, which tends to evolve upon annealing toward Cr/Co/Fe-enriched FCC and Al/Ni-enriched B2. Three conditions were studied: as-printed, 600 °C/5 h, and 1000 °C/1 h, over which B2 lamellae coarsen, lamellar spacing increases, and elemental segregation becomes more prominent. Microstructure and chemistry were characterized by scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS), while in-situ electrochemical atomic force microscopy (EC-AFM) was used to link early (<5 h) local dissolution to microstructure after exposure in sulfuric acid. EC-AFM highlights preferential dissolution of the BCC/B2 phase where the surrounding matrix is Cr-depleted and directly quantifies the dissolution rates within individual phases, tracks the transition from early nano-scale attack to partial repassivation, to correlate height differences with current and impedance responses. To monitor longer-term behavior (up to 96 h), ex-situ AFM, SEM, and confocal imaging were combined with conventional bulk electrochemical tests, bridging nanoscale observations to micro/meso-scale damage morphologies. At the meso-scale, the deepest dissolution channels align with the build-direction lamellae and melt-pool boundaries, indicating that printing directionality guides the propagation of these localized corrosion sites. Annealing modifies corrosion by restructuring BCC/FCC phase fractions, lamellar spacing, and Cr/Al segregation, thereby changing the cathode/anode ratio and passive film stability. The results clarify how as-printed and annealed nano-lamellar architectures differ in their susceptibility to selective dissolution; how elemental segregation competes with residual stresses along the build direction. With these insights, future work will use CALPHAD-guided alloy modification to stabilize higher Cr contents in the B2 phase while retaining a dominant FCC+B2/BCC microstructure, with the goal of designing mechanically robust, corrosion-resistant EHEAs for safety-critical applications to leverage the LLNL’s broader national and global security mission.

36 MATERIALS SCIENCE↗

ZM-21 magnesium alloy corrosion properties and cryogenic to elevated temperature mechanical properties

The mechanical properties of bare ZM-21 magnesium alloy flat tensile specimens were determined for test temperatures of +400 F, +300 F, +200 F, +80 F, 0 F, -100 F, -200 F, and -320 F. The ultimate tensile and yield strengths of the material increased with decreasing temperature with a corresponding reduction in elongation values. Stress corrosion tests performed under: (1) MSFC atmospheric conditions; (2) 95% relative humidity; and (3) submerged in 100 ppm chloride solution for 8 weeks indicated that the alloy is not susceptible to stress corrosion. The corrosion tests indicated that the material is susceptible to attack by crevice corrosion in high humidity and chemical type attack by chloride solution. Atmospheric conditions at MSFC did not produce any adverse effects on the material, probably due to the rapid formation of a protective oxide coating. In both the mechanical properties and the stress corrosion evaluations the test specimens which were cut transverse to the rolling direction had superior properties when compared to the longitudinal properties.

Montana, J. W.↗

Apollo experience report: The problem of stress-corrosion cracking

Stress-corrosion cracking has been the most common cause of structural-material failures in the Apollo Program. The frequency of stress-corrosion cracking has been high and the magnitude of the problem, in terms of hardware lost and time and money expended, has been significant. In this report, the significant Apollo Program experiences with stress-corrosion cracking are discussed. The causes of stress-corrosion cracking and the corrective actions are discussed, in terminology familiar to design engineers and management personnel, to show how stress-corrosion cracking can be prevented.

Johnson, R. E.↗

Effect of a chromium-containing fuel additive on hot corrosion

Four cast superalloys (one cobalt-base and three nickel-base) were tested at 900 C for 100 h in Mach 0.3 combustion gases. 5 ppm of synthetic sea salt were added to the gases in the combustion chamber. Several types of thermal cycle and washing procedures were employed. Similar tests were made with the addition of 300 ppm of a chromium-containing fuel additive. In both sets of tests the extent of hot corrosion was evaluated by specific weight change and metal recession. In general, the chromium additive in the fuel reduced the extent of hot (salt) corrosion but did not eliminate it. The percentage reduction of hot corrosion attack was similar for all four alloys. As great a reduction of hot corrosion was achieved by reducing the number of thermal cycles during the test from 100 to 5 or 6. The effect of washing the alloys every ten cycles as opposed to the end of the test was erratic; some alloys were attacked slightly more, others somewhat less. A NiCrAlY coating was found to be more effective in reducing hot corrosion than either the fuel additive or the washing schedule.

Lowell, C. E.↗

Chemical processes involved in the initiation of hot corrosion of B-1900 and NASA-TRW VIA

Sodium surface-induced hot corrosion of B-1900 and NASA-TRW VIA alloys at 900 C has been studied, with special attention to the chemical reactions during and immediately after the induction period. Thermogravimetric tests were run and data were obtained by chemical analysis of water soluble metal salts and of residual sulfate. Surface analyses of hot corroded samples were obtained by spectroscopic techniques (ESCA). A chemical mechanism for elucidating Na2SO4-induced hot corrosion is proposed indicating that hot corrosion is initiated by basic fluxing of the protective Al2O3 scale. The sequential, catastrophic corrosion results from molybdenum content. The self-sustaining feature is a consequence of the cyclic nature of the acidic fluxing. It is believed that the mechanism is applicable not only to laboratory results, but also to the practical problem of hot corrosion encountered in gas turbine engines.

Fryburg, G. C.↗

Corrosion of 310 stainless steel in H2-H2O-H2S gas mixtures: Studies at constant temperature and fixed oxygen potential

Corrosion of SAE 310 stainless steel in H2-H2O-H2S gas mixtures was studied at a constant temperature of 1150 K. Reactive gas mixtures were chosen to yield a constant oxygen potential of approximately 6 x 10 to the minus 13th power/cu Nm and sulfur potentials ranging from 0.19 x 10 to the minus 2nd power/cu Nm to 33 x 10 to the minus 2nd power/cu Nm. The kinetics of corrosion were determined using a thermobalance, and the scales were analyzed using metallography, scanning electron microscopy, and energy dispersive X-ray analysis. Two corrosion regimes, which were dependent on sulfur potential, were identified. At high sulfur potentials (p sub S sub 2 less than or equal to 2.7 x 10 to the minus 2nd power/cu Nm) the corrosion rates were high, the kinetics obeyed a linear rate equation, and the scales consisted mainly of sulfide phases similar to those observed from pure sulfication. At low sulfur potentials (P sub S sub 2 less than or equal to 0.19 x 10 to the minus 2nd power/cu Nm) the corrosion rates were low, the kinetics obeyed a parabolic rate equation, and scales consisted mainly of oxide phases.

Rao, D. B.↗

High temperature alkali corrosion in high velocity gases

The effects of potential impurities in coal derived liquids such as Na, K, Mg, Ca and Cl on the accelerated corrosion of IN-100, U-700, IN-792 and Mar-M509 were investigated using a Mach 0.3 burner rig for times to 1000 hours in one hour cycles. These impurities were injected in combination as aqueous solutions into the combustor of the burner rig. The experimental matrix utilized was designed statistically. The extent of corrosion was determined by metal recession. The metal recession data were fitted by linear regression to a polynomial expression which allows both interpolation and extrapolation of the data. As anticipated, corrosion increased rapidly with Na and K, and a marked maximum in the temperature response was noted for many conditions. In contrast, corrosion decreased somewhat as the Ca, Mg and Cl contents increased. Extensive corrosion was observed at concentrations of Na and K as low as 0.1 PPM at long times.

Lowell, C. E.↗

Corrosion inhibitors for water-base slurry in multiblade sawing

The use of a water-base slurry instead of the standard PC oil vehicle was proposed for multiblade sawing (MBS) silicon wafering technology. Potential cost savings were considerable; however, significant failures of high-carbon steel blades were observed in limited tests using a water-based slurry during silicon wafering. Failures were attributed to stress corrosion. A specially designed fatigue test of 1095 steel blades in distilled water with various corrosion inhibitor solutions was used to determine the feasibility of using corrosion inhibitors in water-base MBS wafering. Fatigue tests indicate that several corrosion inhibitors have significant potential for use in a water-base MBS operation. Blade samples tested in these specific corrosion-inhibitor solutions exhibited considerably greater lifetime than those blades tested in PC oil.

Chen, C. P.↗

The relative stress-corrosion-cracking susceptibility of candidate aluminum-lithium alloys for aerospace applications

Stress corrosion tests of Al-Li-Cu powder metallurgy alloys are described. Alloys investigated were Al-2.6% Li-1.4% and Al-2.6% Li-1.4% Cu-1.6% Mg. The base properties of the alloys were characterized. Process, heat treatment, and size/orientational effects on the tensile and fracture behavior were investigated. Metallurgical and electrochemical conditions are identified which provide reproducible and controlled parameters for stress corrosion evaluation. Preliminary stress corrosion test results are reported. Both Al-Li-Cu alloys appear more susceptible to stress corrosion crack initiation than 7075-T6 aluminum, with the magnesium bearing alloy being the most susceptible. Tests to determine the threshold stress intensity for the base and magnesium bearing alloys are underway. Twelve each, bolt loaded DCB type specimens are under test (120 days) and limited crack growth in these precracked specimens has been observed. General corrosion in the aqueous sodium chloride environment is thought to be obscuring results through crack tip blunting.

Pizzo, P. P.↗

Mechanism of corrosion of Ni base superalloys by molten Na2MoO4 at elevated temperatures

The corrosion of nickel base superalloy, U-700, by molten Na2MoO4 was studied in the temperature range of 750 deg to 950 deg C. After an induction period, the rate of corrosion is linear and catastrophic corrosion is observed. It is shown that the induction period is associated with the attainment of a minimum MoO3 activity in the melt, which corresponds to the equilibrium MoO3 activity for the reaction, 2MoO3(l) + Mo = 3MoO2(s). A mechanism is proposed to describe the catastrophic nature of corrosion, which involves transport of Ni++ through the melt resulting in formulation of NiO at the melt gas interface and basic fluxing of Cr2O3. The effect of the amount of Na2MoO4 on the corrosion kinetics was also studied. It is found that evaporation and the thermodynamic calculations for the Na2MoO4 - MoO3 system the activity of MoO3 is reduced considerably when dissolved in Na2MoO4, which causes a sharp decrease in the rate of evaporation of MoO3 from a Na2MoO4 - MoO3 melt.

Misra, A. K.↗

Oxidation and hot corrosion of hot-pressed Si3N4 at 1000 deg C

The oxidation and hot corrosion of a commercial, hot-pressed Si3N4 were investigated at 1000 C under an atmosphere of flowing O2. For the hot corrosion studies, thin films of Na2SO4 were airbrushed on the Si3N4 surface. The hot corrosion attack was monitored by the following techniques: continuous weight measurements, SO2 evolution, film morphology, and chemical analyses. Even though the hot corrosion weight changes after 25 hr were relatively small, the formation of SiO2 from oxidation of Si3N4 was an order of magnitude greater in the presence of molten Na2SO4. The formation of a protective SiO2 phase at the Si3N4 surface is minimized by the fluxing action of the molten Na2SO4 thereby allowing the oxidation of the Si3N4 to proceed more rapidly. A simple process is proposed to account for the hot corrosion process.

Fielder, W. L.↗

Corrosion behavior of magnetron sputter-deposited (Mo/0.6/Ru/0.4/)82B18 and Mo82B18 amorphous metal films

Amorphous metallic films of Mo49Ru33B18 and Mo82B18 have been prepared by magnetron sputtering, and their corrosion behavior was investigated and compared with amorphous liquid-quenched Mo49Ru33B18 and crystalline Mo i acidic and basic solutions. Sputtered Mo49Ru33B18 showed lower corrosion rates compared with liquid-quenched Mo49Ru33B18, owing to the superior surface smoothness and uniformity of the former. Amorphous Mo82B18 showed low corrosion rates in both acidic and basic aqueous solutions. Comparison of the corrosion properties of Mo49Ru33B18 with Mo82B18 and Mo demonstrates the roles of the alloys' constituents. Ru significantly extends the passive region to high-anodic potentials, but, at less-anodic potentials, Mo82B18 has the lowest corrosion rate.

Williams, R. M.↗

Role of molybdenum in the Na sub 2SO sub 4 induced corrosion of superalloys at high temperatures

Sodium sulfate induced corrosion of a molybdenum containing nickel-base superalloy, Udimet 700, was studied in laboratory furnace tests and in a high velocity (Mach 0.3) burner rig. The effect of SO2 content in the atmosphere on the corrosion behavior in the laboratory furnace tests was determined. Catastrophic corrosion occurs only when the melt contains MoO3 in addition to Na2SO4 and Na2MoO4. The conditions under which catastrophic corrosion occurs are identified and a mechanism is described to explain the catastrophic corrosion.

Misra, A. K.↗

Aqueous sodium chloride induced intergranular corrosion of Al-Li-Cu alloys

Two methods have been explored to assess the susceptibility of Al-Li-Cu alloys to intergranular corrosion in aqueous sodium chloride solution. They are: (1) constant extension rate testing with and without alternate-immersion preexposure and (2) metallographic examination after exposure to a NaCl-H2O2 corrosive solution per Mil-H-6088F. Intergranular corrosion was found to occur in both powder and ingot metallurgy alloys of similar composition, using both methods. Underaging rendered the alloys most susceptible. The results correlate to stress-corrosion data generated in conventional time-to-failure and crack growth-rate tests. Alternate-immersion preexposure may be a reliable means to assess stress corrosion susceptibility of Al-Li-Cu alloys.

Pizzo, P. P.↗