Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIALIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Laboratory Evaluation of Tunable White LEDs for Circadian Lighting in Commercial Offices

Tunable white Light-Emitting Diode (LED) systems that allow users to control Correlated Color Temperature (CCT) are often marketed for circadian health, which is an emerging priority in commercial office lighting. However, the energy impacts of meeting circadian criteria with standard non-tunable LEDs and with tunable white LEDs are not well understood. The goals of this project were to implement select commercial lighting systems, including tunable white LEDs, to meet visual and circadian criteria in an office environment, and to quantify lighting performance and energy usage. Most recent studies on tunable white LEDs, circadian lighting strategies, and energy impacts have relied on computer simulations and models. While little research has directly measured tunable LED energy usage for circadian criteria, EPRI has recently published results from a lab-based evaluation of illuminance, spectral output, and energy consumption for several LED products marketed for circadian performance. The research presented here contributes to the field by quantifying the performance of market-available technologies through detailed monitoring of performance parameters (such as illuminance, spectral output, glare, and energy consumption) in a physical space (an office environment).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quality Optimization of Commercial FeCrAl Tube Production

The objectives of this report are to summarize the various process parameters and conditions that trigger premature failures during the production steps for Generation II ATF FeCrAl seamless tubes in commercially available manufacturing processes, and to suggest optimized processing routes and parameters to improve the quality and the material yield of commercial tube production. The production process steps include (1) the heat production process, (2) the master bar production process, and (3) the tube reduction process. For heat production, not only chemical composition control but also elimination of solidification defects in the vacuum induction–melted ingot are key. A hot-isostatic press helped in reducing and eliminating the internal, preexisting cracks in the ingot, which could be a source of premature failure (e.g., crack initiation from oxide particles) in the latter part of the tube production process. The master bars were produced by a hot-extrusion process. The area reduction ratio and the extrusion temperature are key to controlling the quality of the master bars and the grain structure. Because of the limited deformation ability of FeCrAl alloys, especially at ambient temperatures, a controlled, uniform grain structure with relatively small grains (<100 µm) is required at the beginning of the tube reduction process. Furthermore, a relatively small amount of area reduction per pass, combined with controlled inter-pass annealing, is important to achieve a reduction in failure events, a highly uniform wall thickness, concentricity, and a high-quality surface finish. Based on the knowledge obtained regarding process conditions, FeCrAl tube production with optimized process parameters is currently in progress. A portion of the final tube inventory was delivered in late June 2017. Cross-sectional microstructural characterization was completed for screening the quality of as-received tubes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters - CRADA 625 (Abstract)

Commercial heat pump water heater (CHPWH) systems significantly decarbonize the commercial and multifamily sectors by eliminating the reliance on gas-fired water heating. CHPWH systems are also well suited to include load shift controls that enable load-up and shed commands for supporting grid reliability and time-of-use pricing structure. However, they have not had wide adoption due to factors including price, complexity, and perceived risk. Although CHPWHs have been available in the US for decades, they have not made significant market gains in part because the systems have required significant and costly engineering design expertise and proved lackluster performance. Successful widespread market adoption requires a different approach; a shift from the current custom specialized expertise project design and installation to a repeatable approach that requires little specialized knowledge or expertise and can deliver persistent performance. Using this type of holistic systems approach requires effectively integrating four CHPWH system key components: primary air-to-water heat pumps; primary thermal storage tanks, a temperature maintenance system, and a control system which has capabilities to manage the primary heat pump cycles, any back-up, supplemental, or temperature maintenance heating, alarms, and grid connectivity allowing for demand response (DR), and/or load shifting. The project team has developed and will implement a suite of tools to support faster, less expensive, and more reliable field installations of CHPWH technology and with the resulting data used to further improve the tool set. These tools include: (1) A tool for optimizing system size and costs. (2) A tool that predicts annual energy use and overall system efficiency. (3) The Advanced Water Heater Specification (AWHS 8.0) defining the components of a full CHPWH system addressing performance requirements by climate zone. (4) The Qualified Products List: (QPL) of approved products that meet the specifications requirements. (5) Training materials including online on-demand modules, instructor-led training, and virtual interactive video tours of CHPWH installations in multifamily buildings. Demonstration site identification in low-income buildings in underserved communities is currently underway. Preliminarily, the team anticipates having three demonstrations in the Pacific Northwest and three in the Northeast for a total of six sites. After the demonstration sites are finalized, and M&V instrumentation installations are complete, the team will gather performance data and confirm whether the CHPWH systems perform as predicted and use the data to improve the existing tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SHASTA: Task 2.2: Sensor Development for Subsurface Hydrogen Storage Monitoring Technology Maturation and Commercialization Plan (TMCP)

In Task 2.2 under the SHASTA program, NETL is developing in-situ optical fiber sensors for real-time monitoring of hydrogen, methane, and chemical parameters such as pH at subsurface hydrogen storage conditions. This Technology Maturation and Commercialization Plan report will provide the summary of NETL sensor development and test results under the SHASTA program to meet the subsurface application requirements and proposed technology maturation and deployment plan, and commercialization potential.

08 HYDROGEN↗

Development and Commercialization of a Nanosegrated Oxygen Evolution Reaction Electrocatalyst (CRADA)

This collaborative project leverages advanced characterization tools, catalyst treatment and electrochemical testing capabilities at LBNL to help commercialize a bimetallic nanosegrated catalysts for oxygen evolution reaction in proton-exchange membrane water electrolyzers. This project also has three industrial partners who are involved in catalyst scale-up synthesis, large electrode fabrication and large electrode electrochemical testing. This project investigates a broad range of topics including electrocatalysis, ink rheology and electrode fabrication and testing. This knowledge could help bridge the performance and durability gap from laboratory-developed materials (such as electrocatalysts) to applications in commercial devices. The research results also bring fundamental understanding of possible degradation mechanisms that occur under extremely oxidative potentials including material and morphological changes. The project will help accelerate the deployment of proton-exchange membrane water electrolyzers. The public benefits could include creating jobs and increasing public awareness of potential clean technologies for green hydrogen production. Ultimately, the project will help national wide effort of flighting climate change and achieving carbon neutrality by 2050.

30 DIRECT ENERGY CONVERSION↗

Technology Transfer from Fermi Research Alliance to Itasca Plastics for the purpose of Commercializing Scintillator Material

Researchers at the Fermi National Accelerator Laboratory (Fermilab) developed extruded plastic scintillator in the late 1990s, which was first used in the D-Zero experiment. Extruded plastic scintillator is currently produced at Fermilab and is used in particle detectors worldwide. The purpose of this CRADA is to transfer the knowledge related to the Fermilab extrusion process to Itasca Plastics, Inc. (Itasca Plastics). Much of this knowledge is contained in documentation that is in the public domain, although it is distributed over several communications (papers, conference records, etc.) and over several years. Under this CRADA Fermilab will assemble the information, provide it to Itasca Plastics and provide limited consulting to complete the knowledge transfer. If the transfer is successful, Itasca Plastics will be able to establish a U.S. commercial manufacturing capability for extruded scintillator material that can be used for high energy physics and commercial applications.

36 MATERIALS SCIENCE↗

Energy impacts of nationwide window upgrades in commercial buildings

This report presents comprehensive estimates of the energy impacts of nationwide commercial building window upgrades in the United States, using a conservative approach. Windows play a substantial role in determining building energy use and occupant experience. Estimates point to commercial building windows impacting loads that represent more than 6 quads (approximately 6%) of annual primary energy use in the U.S. (Harris, 2022). Beyond heating and cooling loads, windows also have effects on lighting and occupant comfort. The fastest route to improving the energy efficiency of windows in U.S. buildings is upgrading or replacing windows in existing buildings. This is due to poor performance of windows in older existing buildings compared to most new construction, low levels of window replacement, and long window service life compared to energy-using building components. Nationwide window upgrades were considered using the following technologies: • Secondary glazing systems • Double pane (clear and tinted) • Triple pane (clear and tinted) • Electrochromic glazing Nationwide upgrades provide on the order of 4%–6% site energy savings in typical buildings, or up to 26% in buildings with the highest savings potential. Electrochromic windows, with their ability to adapt dynamically to environmental conditions, can provide additional benefits, ranging from median savings of 7.2% in buildings with window to wall ratio (WWR) greater than 10% and up to 28% for some buildings. Savings increase substantially for buildings with higher WWR. This study’s approach focused on isolating the direct energy benefits from improvement in window performance, and does not take into account the following additional benefits from window retrofits, which are likely to be substantial: • Managing peak demand and enabling HVAC equipment downsizing. • Energy savings from customizing upgrades to building type and climate. • Energy savings and comfort improvements resulting from post-retrofit reductions in air leakage. • Non-energy benefits, such as occupant comfort and resilience during extreme weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Salt Tank Testbed: a Test Site Designed to Replicate Floor Buckles Observed in Commercial TES Tanks

A test site has been designed and is under construction to replicate the buckling failure ob-served in several in-service storage tanks for nitrate salts operating up to 565°C. In commercial tanks multiple factors have been identified that influence the floors susceptibility to buck-ling, including: the as-manufactured shape of the floor, high compressive stresses due to thermal gradients and/or friction, fluid inventory and absolute temperature. Based on exten-sive modeling analysis it was determined that similar buckles can be reproduced in a scaled test tank (approximately 9x smaller than a representative commercial tank design). To buckle the scaled tank a radial thermal gradient is generated in the tank with a low fluid level, the fluid level is then increased while maintaining the thermal gradient; based on the modeling results just one of these cycles can plastically deform the tank floor. The test site which is under construction is designed to replicate this damaging cycle at lower temperatures. The goal of testing will be to reproduce this damaging cycle and buckle the scaled test tank floor, allowing proper model validation and a methodology for comparing different tank designs at a smaller (and less costly) scale.

25 ENERGY STORAGE↗

Evaluation of DNA Extraction Efficiency in Diverse Algae Strains Using Commercial Kits and Lysis Approaches

Efficient DNA extraction is essential for accurately monitoring microalgae communities in large-scale cultivation systems such as raceway ponds and wastewater ponds. Traditional phenol chloroform extracts are a staple in microbiology but are obsolete for routine sampling due to its high toxicity reagents and time intensive setups. Commercial DNA extraction kits are more favorable for the microbes found in these ponds, but lack specific kits made for these communities. Little is known about which kits perform the best, leading researchers to use a variety of different kits with inconsistent results. This project compared one precipitation based commercial kit (Lucigen Masterpure) and five wash based kits (Monarch, Zymo Quick-DNA, and three Qiagen DNeasy kits) using four brackish algae strains to determine which methods yield the greatest quantity and quality of genomic DNA. Extractions were evaluated using the manufacturers protocol, and additional pretreatment options were administered before a single kit to compare its potential in being added routinely before extractions. Pretreatment options included both cryogenic freeze-thawing and heat incubation using enzymes. DNA was quantified using Qubit fluorometry and NanoDrop purity ratios. Overall, the Qiagen PowerWater kit provided the highest DNA yield and purity, but at a significantly higher cost then the precipitation-based kit (MasterPure). It was also noted that while the precipitation-based kit was significantly cheaper, provided similar results, it took significantly more time to complete a single run. Cryogenic pretreatment (6x cycles) increased average DNA yields by up to 80%, whereas enzymatic pretreatment most improved purity ratios without substantially improving quantity. The results suggest that it may be more cost and time efficient to use Qiagen kits with the addition of lysis pretreatments to procure better results. Future works includes developing a better system to efficiently collect multi variable data, and to upscale to artificial polycultures using similar methodologies alongside sequencing to confirm kit results.

59 BASIC BIOLOGICAL SCIENCES↗

Williston Basin Resource Study for Commercial-Scale Subsurface Hydrogen Storage

The Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), the EERC’s State Energy Research Center (SERC), MPLX Operations LLC, and TC Energy Development Holdings Inc. (a subsidiary of TC Energy Corporation), studied the potential for subsurface hydrogen storage and recovery in the Williston Basin of western North Dakota. The project’s goal was to evaluate the feasibility of large-scale, secure geologic H 2 storage to support future hydrogen generation, storage, and use. This work included laboratory testing, H 2 –rock–fluid exposure experiments, literature reviews on H 2 embrittlement, and reservoir modeling and simulations. The study included an assessment of storage potential across three types of storage reservoirs using both reservoir simulation and DOE’s web-based tool SHASTA-HELP (Subsurface Hydrogen Assessment, Storage, and Technology Acceleration – Hydrogen Estimator for Logistical Planning), as well as investigation of potential H 2 production and markets for commercial-scale deployment. Building on prior EERC gas storage research, three storage options were selected for detailed evaluation: the Broom Creek Formation (a clastic saline reservoir), the Dickinson Lodgepole Mounds (DLM) complex (carbonate mud mound structures) of the Lodgepole Formation (an active oil and gas producing reservoir), and the Dunham Salt Interval of the Piper Formation (to be used for engineered salt cavern development). These targets were prioritized based on prior EERC research using datasets related to seal capacity, reservoir quality, mechanical integrity, and injectivity. Exposure tests on Broom Creek and DLM samples showed mineral dissolution and precipitation that increased brine salinity and altered reservoir rock surfaces. Although these results provide useful insight, they are limited by small sample sizes and short-term (30-day) exposure, requiring further study to assess long-term storage integrity. Salt formations were not tested because of their known nonreactivity and established mechanical stability. Results of reservoir simulations performed for a single site demonstrated that the Broom Creek Formation may be capable of receiving up to 42,000 tonnes of injected H 2 over 7 months via one well. H 2 recovery took place over 5 months, resulting in approximately 26,000 tonnes (~62% without cushion gas [CG]). This work suggests water production may be important and subsequent cycles of injection and production may perform more efficiently; however, significant site-specific work in the future is needed to assess actual reservoir performance of injection and withdrawal of H 2 storage. For oil reservoir potential, a multiple-well model was used to simulate injection of approximately 32,000 tonnes of H 2 into a single wellbore while simultaneously producing in place reservoir fluids from four offset wells to maintain reservoir pressure. The simulation results suggested a high recovery (~98%); in addition, cost advantages through existing infrastructure could be realized. Challenges in this reservoir include vi managing gas purity and leakage risks. In both scenarios, production of H 2 takes place in a single-well scenario with 10 cycles (7 months of injection and 5 months of production) over 10 years. Finally, the use of engineered caverns in the Dunhan Salt was evaluated, and the results suggest that while they have a smaller capacity (<1000 tonnes per cavern), they exhibit nearly complete gas recovery (>99%), fast response times, and low purity risk. While caverns in North Dakota may be smaller in capacity, fields can be developed in galleries to accommodate the volumetric needs and rapid turnaround times necessary to meet market demands. Geographic limitations and thin salt intervals in North Dakota may represent less total storage potential than salt domes elsewhere, but significant opportunities exist to expand this market for gas storage in North Dakota. A basinwide assessment was performed to estimate a first-of-its-kind value for H 2 storage on a large scale. DOE’s SHASTA-HELP, combined with EERC simulation work, was used to perform the assessment. Estimated H 2 storage potential varied widely for each formation type. The Broom Creek saline formation was estimated to have a storage potential of approximately 1.7–90.5 million tonnes (MMt). The DLM oil reservoirs were estimated to have 0.07–0.19 MMt of capacity. Notably, each of these estimates relies on significant assumptions regarding reservoir thickness, porosity, permeability, and CG needed for operation. Much research is needed to understand the true site-specific storage resource potential of each formation. Using the Dunham Salt Interval for cavern development may result in as much as 4.79 MMt (up to 2.87 MMt working gas) of H 2 storage potential. An important note for consideration is that the values presented here need significantly more geological characterization and engineering assessments prior to gaining confidence in performance. This will be a focal point for future research and development needs. The basinwide evaluation also indicated that North Dakota has significant H 2 generation potential, with estimates up to a possible 13 MMt annually, suggesting a substantial opportunity for H 2 market development and thus the need for commercial-scale H 2 storage to facilitate growth and resilience. Key Recommendations 1. Conduct detailed site characterization (3D seismic, well logs, core sampling) to reduce geologic uncertainty. 2. Perform techno-economic analyses incorporating market, regulatory, and incentive frameworks. 3. Investigate long-term interactions among H 2 , CGs, well materials, and formations to assess risks. 4. Develop pilot- and field-scale demonstrations to validate models and establish best practices.

03 NATURAL GAS↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Subsurface H 2 Storage: A Williston Basin Commercial-Scale Resource Study

Poster for the 2024 NETL Resource Sustainability Project Review Meeting, Pittsburgh, Pennsylvania, April 2-4, 2024. This poster presents a commercial‑scale assessment of subsurface hydrogen storage potential in the North Dakota portion of the Williston Basin, evaluating saline formations, depleted oil and gas reservoirs, and salt formations. The study integrates laboratory characterization, reservoir simulation, and basinwide analysis to assess storage capacity, injectivity, recovery, and risks related to geochemical, microbial, and wellbore interactions. Results support the feasibility of large‑volume, secure hydrogen storage and provide a framework to guide future hydrogen commercialization and infrastructure development.

08 HYDROGEN↗

Scaling Sustainable Biochar Research & Commercialization for Agriculture & Conservation: A Summary from a Stakeholder Convening

Biochar is a carbon-rich substance with the potential to increase soil carbon sequestration, reduce greenhouse gas (GHG) emissions and improve soil health. When used as part of soil health management systems, biochar can provide multiple synergistic benefits for the agricultural sector and society, while also supporting the production of renewable, climate-neutral biofuels. Establishing a pyrolysis biochar bioenergy industry (PBBI) is necessary to harness the environmental benefits of biochar. To galvanize the necessary coordination to support a PBBI, the Foundation for Food & Agriculture Research (FFAR), the National Center for Appropriate Technology (NCAT), and American Farmland Trust (AFT) co-hosted a virtual convening event on biochar research and commercialization in March 2022. Participants represented a diverse set of stakeholders, including biochar producers, agricultural producers, and members of nonprofit, industry and government agencies. This whitepaper offers a summary of the convening, as well as insights from subsequent stakeholder engagement. Sustainably sourced, fit-for-purpose biochar can be a powerful tool in the soil health management systems and climate-smart toolbox, with decades of research supporting the soil, environment, production, and climate benefits. However, because biochar represents a range of feedstocks, processes and products, there is a critical need to: • Coordinate efforts to characterize and test the application of biochar types across locations with diverse soil and management conditions • Address research and decision-support gaps • Support the growing industry These objectives can be addressed or advanced through a coordinated strategy. To support establishment of this strategy, the convening participants identified key gaps in implementation and research. The experiences of foresters, ranchers, and farmers already using biochar, some of whom participated in the convening, helped inform priorities. Key gaps include: • Practical, applied on-farm research • Supporting management for agricultural productivity • Maximum benefits for conservation • Decision support • Life Cycle Assessment (LCA) • Quantification of climate mitigation potential Existing research gaps include: • Potential synergies among biochar, soil organic matter, and enhanced rock weathering • Development of new storage reservoirs for biochar in industrial products Convening participants further provided next steps for rapidly developing a PBBI to produce sustainable, fit-for-purpose biochars that increase soil health and mitigate climate change. Participants also stressed the need for actionable, coordinated, large-scale research relevant to commercial production in the next five years. To have a chance to reduce greenhouse gas emissions, we need an array of tools that would aid in mitigation; a coordinated strategy to enable biochar to be an effective tool in the climate-smart toolbox must be created; We cannot wait 50 years.

54 ENVIRONMENTAL SCIENCES↗

Regional Carbon Emission Reduction Prediction via Retrofits of Commercial Buildings with a Case Study of US School Buildings in Hot Climates

Retrofitting commercial buildings has great potential to reduce carbon emissions as demonstrated by previous studies in some specific cities, but their regional carbon emission reduction potential is still unknown. Thus, we develop a method to predict the long-term regional carbon emission reduction potential by retrofitting commercial buildings. School buildings in hot climate zones in the continental U.S. are selected as an example. The results show that the aggregated carbon emission reduction potential of school buildings in that region reduces from 3.33 to 2.01 megatons from 2024 to 2050 due to the increased penetration of renewable energy.

building energy simulation↗

Investigation of microorganisms in cannabis after heating in a commercial vaporizer

There are concerns about microorganisms present on cannabis materials used in clinical settings by individuals whose health status is already compromised and are likely more susceptible to opportunistic infections from microbial populations present on the materials. Most concerning is administration by inhalation where cannabis plant material is heated in a vaporizer, aerosolized, and inhaled to receive the bioactive ingredients. Heating to high temperatures is known to kill microorganisms including bacteria and fungi; however, microbial death is dependent upon exposure time and temperature. It is unknown whether the heating of cannabis at temperatures and times designated by a commercial vaporizer utilized in clinical settings will significantly decrease the microbial loads in cannabis plant material. To assess this question, bulk cannabis plant material supplied by National Institute on Drug Abuse (NIDA) was used to assess the impact of heating by a commercial vaporizer. Initial method development studies using a cannabis placebo spiked with Escherichia coli were performed to optimize culture and recovery parameters. Subsequent studies were carried out using the cannabis placebo, low delta-9 tetrahydrocannabinol (THC) potency and high THC potency cannabis materials exposed to either no heat or heating for 30 or 70 seconds at 190°C. Phosphate-buffered saline was added to the samples and the samples agitated to suspend the microorganism. Microbial growth after no heat or heating was evaluated by plating on growth media and determining the total aerobic microbial counts and total yeast and mold counts. Overall, while there were trends of reductions in microbial counts with heating, these reductions were not statistically significant, indicating that heating using standard vaporization parameters of 70 seconds at 190°C may not eliminate the existing microbial bioburden, including any opportunistic pathogens. When cultured organisms were identified by DNA sequence analyses, several fungal and bacterial taxa were detected in the different products that have been associated with opportunistic infections or allergic reactions including Enterobacteriaceae, Staphylococcus, Pseudomonas, and Aspergillus.

59 BASIC BIOLOGICAL SCIENCES↗