Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COLLIMATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Sketch of a unifying auroral theory

On the basis of field and particle observations, it is suggested that a bright auroral display is a part of a magnetosphere-ionosphere current system which is fed by a charge-separation process in the outer magnetosphere (or the solar wind). The upward magnetic-field-aligned current is flowing out of the display, carried mainly by down-flowing electrons from the hot-particle populations in the outer magnetosphere (the ambient cold electrons being depleted at high altitudes). As a result of the magnetic mirroring of these downflowing current carriers, a large potential drop is set up along the magnetic field, increasing both the number flux and the kinetic energy of the precipitating electrons. It is found that this simple basic model, when combined with wave-particle interactions, may be able to explain a highly diversified selection of auroral particle observations. It may thus be possible to explain both inverted-V events and auroral rays in terms of a static parallel electric field, and the electric field may be compatible with a strongly variable pitch-angle distribution of the precipitating electrons, including distributions peaked at 90 deg as well as 0 deg. This model may also provide a simple explanation of the simultaneous precipitation of electrons and collimated positive ions.

Lennartsson, W.↗

Pulsed X-ray observations of Cen X-3 from Ariel-5

The 4.8 second X-ray pulsations from Centaurus X-3 were monitored by the MSSL collimated proportional counter on board Ariel-5 between 18-27 January 1975. Analysis of the source Doppler effect shows that the pulsation period of Cen X-3 decreased by 3.70 + or - 0.04 milliseconds during the preceding 2.3 years. The Doppler analysis also yields updated values for the binary phase and period of Cen X-3. Phase zero occurred at JD 2442438.628 + or - 0.003, and the average heliocentric binary period between October 1972 and January 1975 was 2.087129 + or - 0.000007 days. Light curves of the 4.8 second pulsations in the 3-9 keV band are characterized by two pronounced peaks, in contrast with the single peak profiles observed by Uhuru.

Tuohy, I. R.↗

Observations of A0620-00 by SAS-3

The transient X-ray source A0620-00 was observed by the SAS-3 group with the SAS-3 X-ray observatory. At maximum X-ray luminosity limits of 2% were placed on periodic variations from 0.2 ms - 2,000 sec. A precise position was obtained with the rotating modulation collimator. This led directly to radio and optical identification by groups at the NRAO, Arecibo, and McGraw Hill Observatories. The low energy (0.15-0.9 keV) system was pointed at the source, and a spectrum was derived. Hardness ratios are presented, as well as detailed light curves.

Bradt, H.↗

An estimate of the influence of sediment concentration and type on remote sensing penetration depth for various coastal waters

Under the assumptions of collimated light, a homogenous water column, zero molecular scattering, and constant ratio of volume scattering function to scattering coefficient, estimates of the remote sensing depth parameter, Z90, are made for various coastal waters at 540 nm. Calculations indicate that sediment concentration and type have a strong influence on remote sensing depth when concentrations are below 5 mg/theta. Above 5 mg/theta, the absorption coefficient of the sediments becomes large in comparison to that of water, causing Z90 values to be less than 2 m with only small differences between various sediment types.

Whitlock, C. H.↗

Apollo 16 far-ultraviolet imagery and spectra of the Large Magellanic Cloud

The Large Magellanic Cloud was observed by the far ultraviolet camera spectrograph from the lunar surface during the Apollo 16 mission 22 April 1972. Images were obtained with about 3 arc min resolution, in the 1,050 to 1,600 and 1,250 to 1,600 A wavelength ranges, of nearly the entire LMC. Spectra were also obtained in the 1,050 to 1,600 and 900 to 1,600 A ranges along a strip 1/4 deg wide (determined by the instrument's grid collimator) passing across the LMC. The images and spectra have been scanned with a PDS microdensitometer, and isodensity contour plots have been prepared using the Univac 1108 computer.

Page, T.↗

Instrumental technique in X-ray astronomy

A detailed review of the development of instruments for X-ray astronomy is given with major emphasis on nonfocusing high-sensitivity counter techniques used to detect cosmic photons in the energy range between 0.20 and 300 keV. The present status of X-ray astronomy is summarized together with significant results of the Uhuru observations, and photon interactions of importance for the detection of X-rays in space are noted. The three principal devices used in X-ray astronomy (proportional, scintillation, and solid-state counters) are described in detail, data-processing systems for these devices are briefly discussed, and the statistics of nuclear counting as applied to X-ray astronomy is outlined analytically. Effects of the near-earth X-ray environment and atmospheric gamma-ray production on X-ray detection by low-orbit satellites are considered. Several contemporary instruments are described (proportional-counter systems, scintillation-counter telescopes, modulation collimators), and X-ray astronomical satellite missions are tabulated.

Peterson, L. E.↗

The Apollo 15 and 16 X-ray fluorescence experiment

An X-ray fluorescence spectrometer was flown aboard the Apollo 15 and 16 spacecrafts orbiting the moon. The X-ray instrument was used to produce a chemical map of that portion of the moon covered by the projected ground tracks and illuminated by the sun during the period of flight. The instrument includes three thin windowed proportional counters, two of which have selected X-ray filters. The field of view of the surface is determined by a collimator, while a detector on the opposite side of the spacecraft provides a continuous monitoring of the solar X-ray output. While the number of chemical elements determined was limited to Mg, Al, and Si, these proved to be very important diagnostic elements.

Adler, I.↗

Atmospheric X-ray Emission Experiment for Shuttle

The Atmospheric X-ray Emission Experiment (AXEE) for Shuttle is designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons. It will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. The instrument concept is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. It will be mounted on an instrument pointing system to provide the required attitude control and is operated by the Spacelab payload specialist who has full control over its observing and data taking modes.

Goldberg, R. A.↗

The Hard X-ray experiment on the Astronomical Netherlands Satellite

The Hard X-ray Experiment flown on the Astronomical Netherlands Satellite is described. The instrument consists of two parts. One is a large-area detector of about 60 sq cm in total area, sensitive in the energy range between 1.5 and 30 keV. Two counters comprise this detector, each collimated 10 min by 3 deg and offset in the narrow direction by 4 min. The other part is a Bragg-crystal assembly consisting of two PET crystals and counters aligned to search for the silicon emission lines near 2 keV. Instrument characteristics and orbital operations are described.

Gursky, H.↗

X-ray nova A0620-00 - Celestial position and low-energy flux

The X-ray nova A0620-00 (Nova Monocerotis 1975) has been observed with the SAS-3 satellite. The 1-10 keV intensity was observed to increase by a factor of 2.3 from August 8 to August 11, 1975. It reached and maintained a constant intensity of 1.7 by 10 to the -6 power erg/sq cm/sec from August 11 to August 13. Limits on periodicities of not more than 2 per cent of the power were obtained for periods from 0.2 ms to 435 s. A precise position was obtained with the SAS-3 modulation collimators on August 15. This led directly to optical and radio identifications. Observations with the SAS-3 low-energy concentrator system on August 27 showed an intense 0.4-0.8 keV flux emanating from the nova. A hydrogen column density of 3.5 (plus or minus 0.3) by 10 to the 21st power per sq cm was inferred from these data.

Doxsey, R.↗

Multistream and Monte Carlo calculations of the sun's aureole

The scattered UV intensities in the sun's aureole are calculated using both a multi-stream scattering method and a Monte Carlo approach. Angular distributions for both Rayleigh and aerosol scatterings are obtained with a realistic atmospheric model. Moderate- and sharply-forward-peaked phase functions of aerosol scattering, corresponding to realistic analytic size distributions, are incorporated. Results from the two independent calculations are in reasonable agreement for a realistic atmospheric model. The results indicate that the scattered UV intensity in the sun's aureole is about four orders smaller than the transmitted intensity while the scattered intensity for pure Rayleigh scattering is only 1-10 millionths times that of the transmitted sun. Based on these intensity ratios, we estimate that the integrated scattered contributions from the aureole to a well-collimated sun photometer of acceptance aperture 2-3 deg are below about 1% of the direct contribution.

Furman, D. R.↗

Visual space perception on a computer graphics night visual attachment

A series of experiments was conducted to compare five psychophysical methods of measuring how people perceive visual space in simulators. Psychologists have used such methods traditionally to measure visual space perception in the real world. Of the five tasks - objective-size judgments, angular-size judgments, shape judgments, slant judgments, and distance judgments - only the angular-size judgment task proved to be of potential use as a measure of simulator realism. In this experiment pilots estimated the relative angular size of triangles placed at various distances along a simulated runway. Estimates made when the display was collimated were closer to real-world performance than estimates made with an uncollimated display.

Palmer, E.↗

Difference thresholds for judgments of sink rate during the flare

Past studies have shown that touchdown rates of descent (sink rates) are higher in aircraft simulators than in aircraft under similar conditions. The objective of this paper was to use a psychophysical technique to investigate a pilot's ability to distinguish between two different sink rates close to the ground. The pilots observed a collimated computer graphics display of a typical runway with edge, zone, and centerline lights. The results showed that with a forward velocity of 120 knots, pilots could reliably distinguish between a sink rate of 0.5 m/sec (1.7 ft/sec) and 0.9 m/sec (2.9 ft/sec). The results also showed that the absolute rate of sink did not significantly affect the perception of sink rate. Time of sink and total height drop during the sink did affect the minimum detectable difference between sink rates (the differential threshold). The effects were such that a greater time of sink and greater height drop produced lower thresholds

Palmer, E.↗

An X-ray survey of BL Lacertae objects

Results are reported for X-ray observations and nearly simultaneous photographic photometry of four BL Lacertae objects (BL Lac, W Com, ON 325, and AP Lib). The X-ray data were obtained in the band from 2.5 to 7.5 keV using a collimated proportional counter aboard OAO-C. Although none of the sources was detected above background at a statistically significant level, two-sigma upper limits on the X-ray flux incident at earth are given for each object. The photometric data indicate that all four objects were near the faint end of their visibility ranges during the time of the X-ray observations. The X-ray upper limits and B magnitudes are employed to calculate upper limits on the brightness temperatures and angular sizes of the radio synchrotron sources; upper limits on the distances to the objects are obtained from limits on the physical source sizes deduced from the radio variabilities. The strictest distance limit is 240 Mpc for BL Lac. Substantial evidence is noted for variability of ON 325 on a timescale of hours.

Margon, B.↗

Recurrent brief X-ray bursts from the globular cluster NGC 6624

Observational data are presented on ten brief X-ray bursts, recurrent at nearly equal time intervals, recorded during a two-day observation of 3U 1820-30 in the globular cluster NGC 6624 with the wide-field modulation collimator detectors on the SAS-3 X-ray observatory. The occurrence times were fitted by least squares to a linear sequence with an rms deviation of 621 sec, corresponding to a phase jitter of 3.9%. The bursts were observed in two energy channels. For a sequence of five of the most clearly observed bursts, the 2-6 keV rate rose to its peak value in about 1 sec and then decayed to preburst level in about 10 sec. The 6-11 keV rate rose more slowly and decayed similarly. The smooth decay of their averaged light curve suggests the temporal evolution may have a geometrical origin, where Compton scattering in a surrounding cloud of hot plasma stretches the pulse out and causes a progressive hardening of the spectrum.

Clark, G. W.↗

A coherent light scanner for optical processing of large format transparencies

A laser scanner is discussed in which the scanning beam is random-access addressable and perpendicular to the image input plane and the irradiance of the scanned beam is controlled so that a constant average irradiance is maintained after passage through the image plane. The scanner's optical system and design are described, and its performance is evaluated. It is noted that with this scanner, data in the form of large-format transparencies can be processed without the expense, space, maintenance, and precautions attendant to the operation of a high-power laser with large-aperture collimating optics. It is shown that the scanned format as well as the diameter of the scanning beam may be increased by simple design modifications and that higher scan rates can be achieved at the expense of resolution by employing acousto-optic deflectors with different relay optics.

Callen, W. R.↗

Dust-contamination monitor

Compact instrument gives instantaneous reading of accumulation of small particles on glass plate. Instrument is sensitive to particles as small as one hundred microns and should be adaptable to monitoring particulate air pollution or dust levels in semiconductor clean rooms. Dual collimated light sources produce highly monochromatic radiation direct at grazing single angle onto glass plate.

Claysmith, C. R.↗

Industrial ion source technology

A 30 cm electron bombardment ion source was designed and fabricated for micromachining and sputtering applications. This source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. An average ion current density of 1 ma/sq cm with 500 eV argon ions was selected as a design operating condition. The ion beam at this operating condition was uniform and well collimated, with an average variation of plus or minus 5 percent over the center 20 cm of the beam at distances up to 30 cm from the ion source. A variety of sputtering applications were undertaken with a small 10 cm ion source to better understand the ion source requirements in these applications. The results of these experimental studies are also included.

Kaufman, H. R.↗