Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLOSURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Qualification of Processing Batches for Tank Closure Cesium Removal Through In-Tank Batch Contact Testing - 20470

The Tank Closure Cesium Removal (TCCR) process at the Savannah River Site (SRS) is currently processing waste from Tank 10H, generating decontaminated salt solution that is sent to Tank 11H. Transfers out of Tank 11H are then disposed of on site as a grout wasteform in the SRS Saltstone Processing Facility. This is a full-scale demonstration of the use of Crystalline Silicotitanate (CST) for the decontamination of aqueous nuclear waste supernate. CST primarily removes cesium from the high sodium alkaline feed, but also adsorbs strontium, actinides, and some other trace metals. The TCCR unit is an at-tank set of four ion exchange columns, with two typically being operated in series during waste processing. Tank 10H is serving a dual function as both the salt dissolution tank as well as the feed tank for the TCCR system. Prior to operation of TCCR, Tank 10H must undergo dissolution campaigns, dissolving the salt cake to form an aqueous salt solution (supernate). After each dissolution campaign, the supernate created must be qualified prior to processing through the TCCR system. Qualification includes detailed characterization of the supernate as well as in-tank batch contact tests to determine the equilibrium loading of Cs-137 on the CST ion exchange media (IONSIV{sup TM} R9120-Ba). In support of the in-tank batch contact testing, Savannah River National Laboratory (SRNL) developed a CST sample holder, also referred to as a 'tea-bag', to hold a measured amount (∼0.1 grams) of pretreated CST between stainless steel screens. The tea-bag fits within a standard stainless steel sample vial that has been modified to allow the flow of supernate to the CST. This sample holder is then immersed in the waste tank allowing free contact between the CST beads and the surrounding liquid, at an effectively infinite liquid-to-solid phase ratio. A pair of tea-bags are deployed in the tank for a period of 10 days for each batch, after which the CST is recovered, digested, and analyzed to determine the loading of cesium isotopes on the CST. This result then supports the TCCR column thermal loading limits for processing as part of the TCCR safety basis. This paper will discuss the design and testing of the CST sample holder, as well as results from the first few batches of waste qualified and subsequently processed through the TCCR system. In addition, results from analyses of Tank 11H samples, showing decontamination of the product will be included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of CTF Droplet Entrainment and Annular/Mist Closure Models using Riso Steam/Water Experiments

This document summarizes the work to validate the droplet entrainment and de-entrainment models, as well as two-phase closure models in the CTF (Coolant Boiling in Rod Arrays - Two Fluids) code by comparison with experimental data obtained at Risoe National Laboratory. CTF is the modernized version of the subchannel code, COBRA-TF, being jointly developed by Oak Ridge National Laboratory and North Carolina State University for applications in the Consortium for Advanced Simulation of Light Water Reactors (CASL). The Risoe data included a series of more than 250 steam/water experiments that were performed in both tube and annulus geometries over a range of various pressures and outlet qualities. Experimental conditions were set so that the majority of cases was in the annular/mist flow regime. Measurements included liquid film flow rate, droplet flow rate, film thickness, and two-phase pressure drop. CTF was used to model 180 of the tubular geometry cases, matching experimental geometry, outlet pressure, and outlet flow quality to experimental values. CTF results were compared to the experimental data at the outlet of the test section in terms of vapor flow fractions, and entrained liquid flow fractions, and pressure drop per unit length.

42 ENGINEERING↗

Evaluating Liquid Waste Transfers and their Impacts to the SRS Tank Farm to Support Operations and Closure

The Liquid Waste (LW) contractor at the Savannah River Site, Savannah River Mission Completion (SRMC), supports the storage, processing, and safe disposition of legacy, radioactive liquid waste. The LW Tank Farms contain approximately 127 million liters (33.5 million gallons) of liquid waste within 43 active, underground waste tanks. To meet mission critical milestones for the closure of waste tanks and processing of 34 million liters (9 million gallons) of salt waste per year by the LW Salt Waste Processing Facility (SWPF), an increase in Tank Farm operations, including waste tank transfers, is required. Waste is compiled in salt and sludge batches in the Tank Farms and transferred to SWPF and the Defense Waste Processing Facility (DWPF) for treatment. All waste tank transfers, such as waste removal and batch compilation transfers, must be pre-evaluated to ensure Documented Safety Analysis (DSA) requirements are met via Evaluated Transfer Approval Forms (ETAFs). Facility conditions and configurations may change as a result of a waste transfer. These changes must be reflected in the Tank Farms Emergency Response Datasheet (ERD), which contains data utilized for operation and emergency situations.

Peterson, Shelby R.↗

DROP TESTS RESULTS OF REVISED CLOSURE BOLT CONFIGURATION OF THE STANDARD WASTE BOX, STANDARD LARGE BOX 2, AND TEN DRUM OVERPACK PACKAGINGS

The Transuranic (TRU) Disposition Project at Savannah River Site will require numerous transfers of radioactive materials within the site boundaries for sorting and repackaging. The three DOT Type A shipping packagings planned for this work have numerous bolts for securing the lids to the body of the packagings. In an effort to reduce operator time to open and close the packages during onsite transfers, thus reducing personnel exposure and costs, an evaluation was performed to analyze the effects of reducing the number of bolts required to secure the lid to the packaging body. The evaluation showed the reduction to one-third of the original number of bolts had no effect on the packagings capability to sustain vibratory loads, shipping loads, internal pressure loads, and the loads resulting from a 4-ft drop. However, the loads caused by the 4-ft drop are difficult to estimate and the study recommended each of the packages be dropped to show the actual effects on the package closure. Even with reduced bolting, the packagings were still required to meet the 49 CFR 178.350 performance criteria for Type A packaging. This paper discusses the effects and results of the drop testing of the three packagings.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closure Report for Corrective Action Unit 134: Aboveground Storage Tanks, Nevada Test Site, Nevada

Corrective Action Unit (CAU) 134 is identified in the Federal Facility Agreement and Consent Order (FFACO) as “Aboveground Storage Tanks” and consists of the following four Corrective Action Sites (CASs), located in Areas 3, 15, and 29 of the Nevada Test Site: · CAS 03-01-03, Aboveground Storage Tank · CAS 03-01-04, Tank · CAS 15-01-05, Aboveground Storage Tank · CAS 29-01-01, Hydrocarbon Stain

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transcatheter Closure of Bilateral Multiple Huge Pulmonary Arteriovenous Malformations with Homemade Double-Umbrella Occluders

A 28-year-old man underwent successful transcatheter occlusion of three huge pulmonary arteriovenous malformations (PAVMs) using homemade double-umbrella occluders and stainless steel coils. Thoracic CT with three-dimensional reconstruction and pulmonary angiography were used for treatment planning and follow-up. The diameters of the feeding vessels were 11 mm, 13 mm, and 14 mm, respectively. This report demonstrates the novel design and utility of the double-umbrella occluder, an alternative tool for treatment of large PAVMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of an inhomogeneous turbulent mixing model for conditional moment closure applied to autoignition

The present paper examines the case of autoignition of high pressure methane jets in a shock tube over a range of pre-heated air temperatures in engine-relevant conditions. The two objectives of the present paper are: (i) to examine the effect of the inhomogeneous mixing model on the autoignition predictions relative to the results obtained using homogeneous mixing models and (ii) to see if the magnitude of the change can explain the discrepancy between the predictions of ignition delay previously obtained with homogeneous mixing models and the experimental data. The governing equation of the scalar dissipation rate is solved for transient conditions and two different formulations of the same model are tested and compared: one using the linear model for the conditional velocity and one including the gradient diffusion model. The predicted ignition kernel location and time delay over a range of pre-combustion air temperatures are compared with results obtained using two homogeneous turbulent mixing models and available experimental data. The profiles of conditional velocity and the conditional scalar dissipation rate are examined. Issues related to the conditional velocity model are discussed. It is found that the differences in the predictions are due to the mixing model only. The inhomogeneous model using the gradient conditional velocity model produces much larger ignition delays compared to the other models, whereas the inhomogeneous form including the linear model does not produce any significant differences. The effect of the turbulent inhomogeneous model is larger at high air temperatures and decreases with decreasing air temperatures. In comparison with the measured ignition delays, the inhomogeneous-Gradient model brings a small improvement at high air temperatures over the results from the turbulent homogeneous models. At low air temperatures, other parameters need to be investigated in order to bring the predicted ignition delays and locations within the experimental data scatter. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improvement of two-phase closure models in CTF using Bayesian inference

Under the Consortium for Advanced Simulation of Light Water Reactors (CASL) program, extensive capabilities have been developed in CTF to analyze light-water reactors (LWRs) for normal operating conditions, departure from nucleate boiling (DNB), and system transients. However, further improvements are required in the modeling and simulation of boiling water reactors (BWRs), which is a focus of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this work, CTF validation results were used to optimize selected modeling coefficients by calibrating to experimental data using a Bayesian inference approach. Here, calibration studies were conducted to improve (vapor) void fraction prediction without worsening the two-phase pressure drop prediction, as well as to improve the two-phase pressure drop prediction. Calibration was performed for interfacial drag and wall shear models. Surrogates were developed to alleviate the computational expense required for sampling the parameter space using Markov chain Monte Carlo (MCMC). An assessment performed with calibrated models demonstrated an improvement of CTF in its prediction of key parameters such as void fraction and two-phase pressure drop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Approaching the N=82 shell closure with mass measurements of Ag and Cd isotopes

Mass measurements of neutron-rich Cd and Ag isotopes were performed with the Penning trap mass spectrometer ISOLTRAP. The masses of {sup 112,114-124}Ag and {sup 114,120,122-124,126,128}Cd, determined with relative uncertainties between 2x10{sup -8} and 2x10{sup -7}, resulted in significant corrections and improvements of the mass surface. In particular, the mass of {sup 124}Ag was previously unknown. In addition, other masses that had to be inferred from Q values of nuclear decays and reactions have now been measured directly. The analysis includes various mass differences, namely the two-neutron separation energies, the applicability of the Garvey-Kelson relations, double differences of masses deltaV{sub pn}, which give empirical proton-neutron interaction strengths, as well as a comparison with recent microscopic calculations. The deltaV{sub pn} results reveal that for even-even nuclides around {sup 132}Sn the trends are similar to those in the {sup 208}Pb region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗