Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Fully depleted charge‐coupled device design and technology development

Abstract We describe the advancement of fully depleted charge‐coupled device (CCD) technology for scientific applications. Recent efforts on 650–725 m‐thick CCDs for direct dark‐matter and radiation detection with single‐electron sensitivity are described, as well as the technology transfer of the fully depleted CCD technology to 200 mm‐wafer fabrication facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Surface Phenomena Created by Underground Chemical Explosions in Dry Alluvium and Granite Geology From Fully Polarimetric VideoSAR Data

Phase I of the Source Physics Experiment (SPE) series involved six underground chemical explosions, all of which were conducted at the same experimental pad. Research from the sixth explosion of the series (SPE-6) demonstrated that polarimetric synthetic aperture radar (PolSAR) is a viable technology for monitoring an underground chemical explosion when the geologic structure is Cretaceous granitic intrusive. It was shown that a durable signal is measurable by the H/A/α polarimetric decomposition parameters. After the SPE-6 experiment, the SPE program moved to the Phase II location, which is composed of dry alluvium geology (DAG). The loss of wavefront energy is greater through dry alluvium than through granite. In this article, we compare the SPE-6 analysis to the second DAG (DAG-2) experiment. We hypothesize that despite the geology at the DAG site being more challenging than at the Phase I location, combined with the DAG-2 experiment having a 3.37 times deeper scaled depth of burial than the SPE-6, a durable nonprompt signal is still measurable by a PolSAR sensor. We compare the PolSAR time-series measures from videoSAR frames, from the SPE-6 and DAG-2 experiments, with accelerometer data. We show which PolSAR measures are invariant to the two types of geology and which are geology dependent. We compare a coherent change detection (CCD) map from the DAG-2 experiment with the data from a fiber-optic distributed acoustic sensor to show the connection between the spatial extent of coherence loss in CCD maps and spallation caused by the explosion. Finally, we also analyze the spatial extent of the PolSAR measures from both explosions.

42 ENGINEERING↗

Low Activity Tritium Detection in CCDs Using Deep Learning Techniques

Here, this study explores the use of charge-coupled devices (CCDs) for detecting low-energy beta particles from tritium decay - a critical signal for nuclear safety, nuclear nonproliferation, and environmental monitoring. We employ a dual approach utilizing both measured CCD data and detailed Geant4 simulations. Our analysis compares classical techniques with advanced deep learning methods, including convolutional neural networks (CNNs), autoencoders trained exclusively on tritium data, and preliminary studies on boosted decision trees (BDTs). The CNN, trained on mixed signal/background datasets, demonstrates superior classification performance, while the autoencoder shows the potential of unsupervised, background-agnostic strategies when background characteristics are poorly defined. These results highlight the excellent sensitivity achievable thanks to the background rejection made possible by information-rich CCD data, paving the way for improved portable tritium monitoring.

Autoencoder↗

Determining Camera Gain in Room Temperature Cameras

James R. Janesick provides a method for determining the amplification of a CCD or CMOS camera when only access to the raw images is provided. However, the equation that is provided ignores the contribution of dark current. For CCD or CMOS cameras that are cooled well below room temperature, this is not a problem, however, the technique needs adjustment for use with room temperature cameras. This article describes the adjustment made to the equation, and a test of this method.

47 OTHER INSTRUMENTATION↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniaturized Electronic System for the Planetary Integrated Camera Spectrometer

This paper discusses the design and implementation of a miniaturized electronic system for the Planetary Integrated Camera-Spectrometer (PICS). The PICS electronics demonstrates the application of Field Programmable Gate Arrays (FPGAs) and of analog hybrid technology to space flight multispectral systems. A discussion of the electronic system design illustrates how a multisensor instrument consisting of an UV CCD, two visible CCDs, and a near-IR focal plane assembly can be processed through a common set of electronics. Following the system design discussion, the actual electronic design will be presented. Each miniaturized module will be discussed as to functionality and performance. The test setup for bench checkout of a cooled CCD and an IR FPA, including results with breadboard electronics and with the hybrids are also described.

CCD↗

Interlayer Design for Halide Electrolytes in All‐Solid‐State Lithium Metal Batteries

Abstract All‐solid‐state lithium‐metal batteries (ASSLMBs) are promising for transportation electrification due to their superior safety and high energy density. Lithium halide electrolytes provide excellent processing flexibility, high ionic conductivity, and anodic stability (>4.1 V), making them highly compatible with high‐voltage cathodes, surpassing sulfide electrolytes (<2.1 V). Nevertheless, halide electrolytes suffer from low cathodic stability and form an electronically conductive interphase with lithium, resulting in a critical current density (CCD) of nearly zero. Herein, Li 3 YbCl 6 electrolytes are synthesized that are kinetically stable with lithium by forming an electronic insulating solid electrolyte interphase. Guided by critical overpotential criteria, a PI 3 interlayer is designed that transforms into Li 6 PI 3 upon contact with lithium, substantially reducing the interfacial resistance of Li 3 YbCl 6 against lithium to 34 Ω and achieving a high critical overpotential of 114 mV. By substituting Yb with Lu, Li 3 LuCl 6 electrolytes with Li 6 PI 3 interlayers reach a CCD of 1.0 mA cm −2 at a capacity of 1.0 mAh cm −2 , comparable to sulfide electrolytes but with higher oxidation stability. Additionally, Li 6 PI 3 enables stable cycling of Li//Li cells with Li 3 LuCl 6 electrolytes at 0.5 mA cm −2 for 400 cycles and maintains 86.5% capacity in Li//LiCoO 2 cells after 220 cycles at 30 °C, paving the way for high‐performance ASSLMBs.

Chemistry↗

Chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic ( Allium ampeloprasum L.) by liquid chromatography tandem mass spectrometry

Abstract Introduction Giant garlic is a functional food that contains different kinds of bioactive molecules with beneficial effects on chronic noncommunicable diseases like diabetes and cardiovascular conditions. Considering biosynthesis pathways, abundance, and biological activity, alliin and S‐allyl‐cysteine were used as chemical markers of organosulphur compounds present in giant garlic. Objective To establish a chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic by liquid chromatography tandem mass spectrometry (LC–MS/MS). Methodology Samples were blanched (ca. 90°C for 10 min) to inactivate alliinase and γ‐glutamyl transpeptidase enzymes and then freeze‐dried. Chemometric optimisation was performed via response surface methodology based on central composite design (CCD). Organosulphur compound yields were determined applying a validated LC–MS/MS method in multiple reaction monitoring (MRM) mode using the following transitions: for alliin m/z 178 → 74 and for S‐allyl‐cysteine m/z 162 → 41. Results According to CCD results, under constant conditions of pressure (1500 psi) and time (20 min), the optimal conditions for pressurised liquid extraction of alliin and S‐allyl‐cysteine were 70.75 and 68.97% v/v of ethanol in extraction solvent and 76.45 and 98.88°C as extraction temperature, respectively. Multiple response optimisation for the simultaneous extraction of both organosulphur compounds was established via desirability function. Under these conditions, 2.70 ± 0.27 mg g −1 dry weight (DW) of alliin and 2.79 ± 0.22 mg g −1 DW of S‐allyl‐cysteine were extracted. Conclusions These results clearly demonstrated that pressurised liquid extraction is an efficient green technique to extract bioactive organosulphur compounds from giant garlic. Extraction yields were significantly ( p < 0.05) higher than those obtained with conventional ultra‐turrax extraction.

Peterssen‐Fonseca, Darlene↗

Removal of Congo Red from Aqueous Solution by Hydroxyapatite Nanoparticles Loaded on Zein as an Efficient and Green Adsorbent: Response Surface Methodology and Artificial Neural Network-Genetic Algorithm

This study is based on the application of hydroxyapatite nanoparticles loaded on Zein (Zein/nHAp) as an efficient adsorbent for the removal of Congo red from aqueous solutions. The properties of the adsorbent were characterized using various techniques including FT-IR, XRD, FE-SEM, and BET. The influence of five parameters such as pH, temperature, contact time, initial dye concentration, and adsorbent dosage on the removal percentage of the dye was investigated. The optimum conditions of 5.83, 34.32 °C, 5.20 min, 392.10 ppm, and 0.007 g were achieved for pH, temperature, contact time, initial dye concentration, and adsorbent dosage, respectively. The maximum removal percentage of 99.48% was obtained under the optimum condition that exhibited high adsorption potential of the used adsorbent. Central composite design (CCD) under response surface methodology and artificial neural network-genetic algorithm (ANN-GA) were utilized for optimization of parameters. Comparison of the results of the two models in terms of coefficient of determination (R{sup 2}) and mean absolute percentage error confirmed the prediction potential of CCD and ANN-GA. Higher ability and accuracy of ANN-GA in prediction was found based on given results. The experimental equilibrium data were studied by Langmuir, Freundlich, Temkin and Dubinin-Radushkevic isotherm models and explored that the data well presented by Langmuir model with maximum adsorption capacity of 416.66 mg/g. The adsorption kinetic was well-fitted by the pseudo-second-order model. The thermodynamics of the adsorption displayed spontaneous and endothermic nature of the process. Regeneration investigation showed that Zein/nHAp can impressively be reused, indicating that the adsorbent was a promising one for the removal of Congo red from aqueous solution. Graphical Abstract: .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low-rank factorization of electron integral tensors and its application in electronic structure theory

In this letter, we introduce the reverse Cuthill-McKee (RCM) algorithm, which is often used for the bandwidth reduction of sparse tensors, to transform the two-electron integral tensors to their block diagonal forms. By further applying the pivoted Cholesky decomposition (CD) on each of the diagonal blocks, we are able to represent the high-dimensional two-electron integral tensors in terms of permutation matrices and low-rank Cholesky vectors. This representation facilitates the low-rank factorization of the high-dimensional tensor contractions that are usually encountered in post-Hartree-Fock calculations. In this letter, we discuss the second-order Møller-Plesset (MP2) method and linear coupled- cluster model with doubles (L-CCD) as two simple examples to demonstrate the efficiency of the RCM-CD technique in representing two-electron integrals in a compact form.

electronic structure theory↗

Characterizing the Li–Li 7 La 3 Zr 2 O 12 interface stability and kinetics as a function of temperature and current density

The stability and kinetics of the Li–Li 7 La 3 Zr 2 O 12 (LLZO) interface were characterized as a function of temperature and current density. Polycrystalline LLZO was densified using a rapid hot-pressing technique achieving 97 ± 1% relative density, and <10% grain boundary resistance; effectively consisting of an ensemble of single LLZO crystals. It was determined that by heating to 175 °C, the room temperature Li-LLZO interface resistance decreases dramatically from 5822 (as-assembled) to 514 Ω cm 2 ; a > 10-fold decrease. In characterizing the maximum sustainable current density (or critical current density – CCD) of the Li-LLZO interface, several signs of degradation were observed. In DC cycling tests, significant deviation from Ohmic behavior was observed. In post-cycling tests, regions of metallic Li were observed; propagating parallel to the ionic current. For the cells cycled at 30, 70, 100, 130 and 160 °C, the CCD was determined to be 50, 200, 800, 3500, and 20000 μA cm –2 , respectively. As a result, the relationships and phenomena observed in this work can be used to better understand the Li-LLZO interface stability, enabling the use of batteries employing Li metal anodes.

36 MATERIALS SCIENCE↗

Plasmonic Ag/Ag2O nanoparticles anchored needle-like Bi2O3 as an efficient visible-light-driven nanocomposite photocatalyst

Highlights: • Deposition of plasmonic Ag/Ag{sub 2}O NPs on the surface of Bi{sub 2}O{sub 3}. • Synthesis of Ag/Ag{sub 2}O@Bi{sub 2}O{sub 3} by thermal-assisted precipitation. • SPR of Ag enhances use of solar energy and transfer of carriers. • Degradation of Reactive Black 5 by CCD model. - Abstract: In this study, a thermal-assisted precipitation method was applied for the uniform deposition of plasmonic Ag/Ag{sub 2}O nanoparticles on the surface of needle-like Bi{sub 2}O{sub 3} to synthesis Ag/Ag{sub 2}O@Bi{sub 2}O{sub 3} nanocomposite. The synthesized nanocomposite was characterized by different techniques including UV–vis spectrophotometry, X-ray diffraction (XRD), scanning electronic microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray mapping, and photoluminescence (PL). The visible-light-driven photocatalytic activities of Ag{sub 2}O@Bi{sub 2}O{sub 3} and Ag/Ag{sub 2}O@Bi{sub 2}O{sub 3} were evaluated on photo-degradation of Reactive Black 5 (RB 5) dye as model pollutant. The effect of process variables including the initial dye concentration, reaction time, and pH on the photo-degradation of RB 5 was studied by Central Composite Design (CCD) methodology. It was found that the photo-degradation rate of Ag/Ag{sub 2}O@Bi{sub 2}O{sub 3} was higher than that of the Ag{sub 2}O@Bi{sub 2}O{sub 3} and Bi{sub 2}O{sub 3}. The highly efficient photocatalytic activity of Ag/Ag{sub 2}O@Bi{sub 2}O{sub 3} nanocomposite is mainly ascribed to enhancing photogenerated electron-hole separation and the surface plasmon resonance (SPR) influence of silver-based nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15μm has been achieved, which is equivalent to a UCN energy resolution below 2 pico-electron-volts through the relation δE=m 0 gδx. Here, the symbols δE, δx, m 0 and g are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. As a result, this method allows different types of UCN spectroscopy and other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dispersive Fourier transformation for megahertz detection of coherent stokes and anti-stokes Raman spectra

In many fields of study, from coherent Raman microscopy on living cells to time-resolved coherent Raman spectroscopy of gas-phase turbulence and combustion reaction dynamics, the need for the capability to time-resolve fast dynamical and nonrepetitive processes has led to the continued development of high-speed coherent Raman methods and new high-repetition rate laser sources, such as pulse-burst laser systems. However, much less emphasis has been placed on our ability to detect shot to shot coherent Raman spectra at equivalently high scan rates, across the kilohertz to megahertz regime. This is beyond the capability of modern scientific charge coupled device (CCD) cameras, for instance, as would be employed with a Czerny-Turner type spectrograph. In this paper, as an alternative detection strategy with megahertz spectral detection rate, we demonstrate dispersive Fourier transformation detection of pulsed (~90 ps) coherent Raman signals in the time-domain. Instead of reading the frequency domain signal out using a spectrometer and CCD, the signal is transformed into a time-domain waveform through dispersive Fourier transformation in a long single-mode fiber and read-out with a fast sampling photodiode and oscilloscope. Molecular O- and S-branch rotational sideband spectra from both N 2 and H 2 were acquired employing this scheme, and the waveform is fitted to show highly quantitative agreement with a molecular model. Finally, the total detection time for the rotational spectrum was 20 ns, indicating an upper limit to the detection frequency of ~50 MHz, significantly faster than any other reported spectrally-resolved coherent anti-Stokes Raman detection strategy to date.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polychromatic X-ray Micro- and Nanodiffraction for Spatially-Resolved Structural Studies

The availability of intense, focused synchrotron X-ray microbeams has enabled new techniques for materials investigations with sub-micron spatial resolution. The scanning microbeam setup we have developed at the XOR-UNI beamline at the Advanced Photon Source (APS) is versatile in that it provides 1D, 2D or 3D scans (including depth resolution), and can alternate between polychromatic- and monochromatic-beam modes. Focusing in both modes uses elliptical Kirkpatrick-Baez (K-B) reflecting mirrors. Beam diameters of {approx} 500 nm FWHM are now routine, and 90 nm focus has been demonstrated. In white-beam mode, a CCD detector records a complete Laue diffraction pattern, which is analyzed with an automated indexing program. These X-ray diffraction patterns provide real-space maps of the local lattice structure, crystal orientation, grain morphology, and strain tensor. Spatially-resolved X-ray microdiffraction studies are now providing previously unavailable measurements of local microstructures. These measurements, in turn, yield new insights in several classic fields of materials science. This paper will illustrate the application of polychromatic scanning X-ray microscopy with examples from 1D, 2D and 3D materials systems. In 1D systems, we have mapped the structure and orientation of an individual ZnO nanorod along with the associated Ge catalyst particle used to control the nanocrystal growth. In 2D systems, X-ray microdiffraction studies have revealed the mechanisms for local crystallographic tilting in epitaxial oxide films grown on textured Ni substrates for superconducting applications. In 3D systems, X-ray microscopy investigations have included in-situ studies of microstructural evolution during thermal grain growth in polycrystalline aluminum. In general, these spatially-resolved measurements provide important new insights and are valuable as input for theoretical and computer modeling studies of a wide range of material processes.

43 PARTICLE ACCELERATORS↗

Optimization of stabilized leachate treatment using ozone/persulfate in the advanced oxidation process

Highlights: ► Ozone and persulfate reagent (O{sub 3}/S{sub 2}O{sub 8}{sup 2-}) was used to treat stabilized leachate. ► Central composite design (CCD) with response surface methodology (RSM) was applied. ► Operating variables including ozone and persulfate dosage, pH variance, and reaction time. ► Optimum removal of COD, color, and NH{sub 3}–N was 72%, 96%, and 76%, respectively. ► A good value of ozone consumption (OC) obtained with 0.60 (kg O{sub 3}/kg COD). - Abstract: The objective of this study was to investigate the performance of employing persulfate reagent in the advanced oxidation of ozone to treat stabilized landfill leachate in an ozone reactor. A central composite design (CCD) with response surface methodology (RSM) was applied to evaluate the relationships between operating variables, such as ozone and persulfate dosages, pH, and reaction time, to identify the optimum operating conditions. Quadratic models for the following four responses proved to be significant with very low probabilities (<0.0001): COD, color, NH{sub 3}–N, and ozone consumption (OC). The obtained optimum conditions included a reaction time of 210 min, 30 g/m{sup 3} ozone, 1 g/1 g COD{sub 0}/S{sub 2}O{sub 8}{sup 2-} ratio, and pH 10. The experimental results were corresponded well with predicted models (COD, color, and NH{sub 3}–N removal rates of 72%, 96%, and 76%, respectively, and 0.60 (kg O{sub 3}/kg COD OC). The results obtained in the stabilized leachate treatment were compared with those from other treatment processes, such as ozone only and persulfate S{sub 2}O{sub 8}{sup 2-} only, to evaluate its effectiveness. The combined method (i.e., O{sub 3}/S{sub 2}O{sub 8}{sup 2-}) achieved higher removal efficiencies for COD, color, and NH{sub 3}–N compared with other studied applications. Furthermore, the new method is more efficient than ozone/Fenton in advanced oxidation process in the treatment of the same studied leachate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗