Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Data Acquisition System for RF Cavity Hadron Monitor

As Fermilab pursues intensity frontier physics, the conventional detectors are not up to the challenge of higher radiation exposure. The detectors in the NuMI beamline rely on knowing the angular distribution of the secondary hadrons in order to infer properties of the resultant neutrino beam. A novel gas-filled RF cavity beam detector is proposed that will be simple and radiation robust in high-radiation environments. Charged particles passing through the cavity produce ionized plasma, which changes the permittivity of the gas and modulate the stored RF field in the cavity. The preliminary beam test of an RF cavity demonstrates the proof of principle of the beam detector. In an effort to acquire a large amount of data for various cavity parameters, an automatic data acquisition (DAQ) system is designed in LabVIEW. The DAQ system utilizes a Real-Time Power meter from Boonton to acquire RF power data from the cavity.

43 PARTICLE ACCELERATORS↗

Identifying and evaluation of contamination sources during clean room preparation of SRF cavities

Particles are one possible cause of field emission issues in SRF cavity operations. During clean room cavity preparation, several processes could contribute to the generation of particles. One of them is friction between hardware during assembly and disassembly. It is important to understand the behaviours that generate and propagate particles into cavities. Using a single cell cavity, particle shedding between flanges and other materials have been tested. The number of particles is recorded with an airborne particle counter, and the generated particles are examined with microscope. The migration of particles into a cavity due to different movements is studied. Suggestions are made to reduce particle generation and prevent contamination of the cavity interior area.

Zhao, Liang↗

Progress With Multi-Cell Nb3Sn Cavity Development Linked With Sample Materials Characterization

Exploiting both the new Nb3Sn coating system and the materials characterization tools nearby, we report our progress in low-loss Nb3Sn films development. Nb3Sn films a few micrometers thick were grown on Nb coupons as well as single- and multi-cell cavities by the Sn-diffusion technique. Films structure and composition were investigated on coated samples and cavity cutouts with characterization tools including SEM/EDS/EBSD, AFM, XPS, SIMS towards correlating film growth and RF loss to material properties and deposition parameters. Cavity coating efforts focused on establishing techniques for coating progressively more complicated RF structures, and understanding limiting mechanisms in coated cavities. Nb3Sn coated 1.5 GHz 1-cell and 1.3 GHz 2-cell cavities have shown quality factors of 1010 at 4.3 K, with several cavities reaching above Eacc = 10 MV/m. The dominant limiting mechanisms were low field quenches and quality factor degradation above 8 MV/m. The surface data indicates a near-stoichiometric Nb3Sn consistent with the transition temperature and gap measurements. The Nb3Sn layer is covered with Nb2O5 and SnO2 native oxides and has little memory of the pre-coating surface.

Eremeev, Grigory V.↗

RF Performance of Ingot Niobium Cavities of Medium-Low Purity

Superconducting radio-frequency cavities made of ingot niobium with residual resistivity ratio (RRR) greater than 250 have proven to have similar or better performance than fine-grain Nb cavities of the same purity, after standard processing. The high purity requirement contributes to the high cost of the material. As superconducting accelerators operating in continuous-wave typically require cavities to operate at moderate accelerating gradients, using lower purity material could be advantageous not only to reduce cost but also to achieve higher Q0-values, because of the well-known dependence of the BCS-surface resistance on mean free path. In this contribution we present the results from cryogenic RF tests of 1.3-1.5 GHz single-cell cavities made of ingot Nb of medium (RRR=100-150) and low (RRR=60) purity from different suppliers. Cavities made of medium-purity ingots routinely achieved peak surface magnetic field values greater than 70 mT with Q0-values above 1.5·1010 at 2 K. The performance of cavities made of low-purity ingots were affected by significant pitting of the surface after chemical etching.

Ciovati, Gianluigi↗

Identification and Evaluation of Contamination Sources During Clean Room Preparation of SRF Cavities

Particles are one possible cause of field emission issues in SRF cavity operations. During clean room cavity preparation, several processes could contribute to the generation of particles. One of them is friction between hardware during assembly and disassembly. It is important to understand the behaviours that generate and propagate particles into cavities. Using a single cell cavity, particle shedding between flanges and other materials have been tested. The number of particles is recorded with an airborne particle counter, and the generated particles are examined with microscope. The migration of particles into a cavity due to different movements is studied. Suggestions are made to reduce particle generation and prevent contamination of the cavity interior area.

Zhao, Liang↗

Magnetic Flux Generated by Thermal Current in CEBAF 5-Cell Cavity System

The unloaded quality factor Q0 of many 5-cell CEBAF cavities were lowered by a factor of ~2 from their vertical qualification testing to their beam operation in CEBAF tunnel. Causes of this Q0 degradation were studied previously, including a more recent one addressing static fluxes arising from magnetic components near a 5-cell cavity. This paper reports on a preliminary study of the dynamic fluxes generated by a thermal current. Such a thermal current arises from the Seebeck effect and flows in closed loops formed by a niobium cavity and its surrounding tuner rods and liquid helium vessel that are made of stainless-steel. The behaviors of magnetic fluxes in response to various thermal profiles on a 5-cell CEBAF cavity with integrated tuner rods were studied in a JLAB VTA dewar. An outcome of this study is a proposed cool-down procedure for eliminating the thermal current generated magnetic fluxes around 5-cell cavities placed in CEBAF tunnels. This procedure may be useful to improve cavity Q0 in a cost-effective manner, which in turn saves cryogenic expenditures for sustaining CEBAF operation.

Geng, Rongli↗

Optimal Thermal Gradient for Flux Expulsion in 600°C Heat-treated CEBAF 12 GeV Upgrade Cavities

We will present results on measurement of flux expulsion in CEBAF 12 GeV upgrade cavities and original CEBAF cavities and the search for optimal thermal gradient for reducing the trapped flux in cavities installed in CEBAF linacs. Preliminary measurements of one C100 cavities has shown that a nearly perfect flux expulsion can be achieved at an optimal thermal gradient - a surprising result contrary to the expectation of zero flux expulsion for 600°C heat treated niobium cavities. These results could lead to a cost-effective path for improving the quality factor of cavities installed in CEBAF and ultimately saving accelerator operation cost.

Geng, R.↗

Study on Electropolishing Conditions for 650 MHz Niobium SRF Cavity

The PIP II linear accelerator includes different types of niobium SRF cavities including 650 MHz elliptical low (0.61) and high (0.92) beta cavities. The elliptical cavity surface is processed with the electropolishing method. The elliptical cavities especially the low-$\beta$ 650 MHz cavities showed a rough equator surface after the EP was per-formed with the standard EP conditions. This work was focused to study the effect of different EP parameters, including cathode surface area, temperature and voltage, and optimize them to improve the cavity surface.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

INVESTIGATION AND OPTIMIZATION OF A NEW COMPACT SUPERCONDUCTING CAVITY FOR DEFLECTING AND CRABBING APPLICATIONS

Deflecting and crabbing structures have many applications in current accelera?tor systems. The primary use of a deflecting cavity is to separate a single beam into multiple beams. A crabbing cavity enables the head-on collision at the inter?action point in particle colliders in order to increase the luminosity. The early uses of the deflecting structures have been in the early 1960s; these structures were disk loaded structures operating at room temperature. The crabbing structure which was installed at the KEK electron-positron collider was the first and only operational superconducting cavity of that kind. The most common design of superconduct?ing deflecting and crabbing cavities is a squashed-elliptical geometry operating in a TM110-like mode; at low frequencies these structures become challenging due to the large geometrical shapes. Recently, compact deflecting and crabbing structures have been studied for numerous accelerator applications not limited to deflecting or crabbing of beams, but also for beam diagnostics, emittance exchange etc. The rf?dipole design, which is presented here, has evolved from the parallel-bar design and is a new compact deflecting and crabbing design with attractive properties at low frequencies and is operating in a TE11-like mode. The parallel-bar design has been optimized into the rf-dipole design primarily to maximize the net deflection with low and balanced peak surface fields and also to maximize the shunt impedance. The geometries have also been modified to increase the separation between the higher or?der modes, suppress multipacting conditions and reduce multipole components. The design geometries have been improved for mechanical stability in order to withstand thermal and pressure fluctuations under operating conditions. Two superconducting rf-dipole deflecting and crabbing cavities have been designed and optimized at 499 MHz for the Jefferson Lab 12 GeV Upgrade and at 400 MHz for a crabbing cavity for the LHC Luminosity Upgrade. The design optimization, fabrication, and test results of the first prototypes of both designs are presented in detail.

De Silva, Subashini Uddika↗

Temperature Mapping analysis of Nitrogen-doped Niobium Radio Frequency Cavity

Nitrogen-doping of niobium superconducting radio-frequency (SRF) cavity has been shown to significantly improve the quality factors as compared to the standard treated niobium cavities. However, the nitrogen-doped cavities generally quench at lower accelerating gradients. To understand the possible sources of rf losses in nitrogen-doped cavities that could reduce the quench field, we used 576 thermometer sensors to map the temperature distribution of the outer cavity surface while increasing the accelerating field. Our measurements have revealed a strong effect of the cavity cooldown rate on the intensity of hot spots and their spatial distribution, indicating a significant contribution from trapped vortices on the RF losses.

Makita, Junki↗

Measurements of Magnetic Field Penetration of Materials for Superconducting Radiofrequency Cavities

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently high purity niobium is the material of choice for SRF cavities which have been optimized to operate near their theoretical field limits. This brings about the need for significant R&D efforts to develop next generation superconducting materials which could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate in a supercon- ductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements which are strongly influenced by the film orientation and shape and edge effects. The applied magnetic field is also needed to be parallel to the one side of the superconductor to resemble the magnetic field profile at the surface of the SRF cavities operating at fundamental accelerating mode. In this work we report the development of an experimental setup called Magnetic Field Penetration (MFP) magnetometer to measure the field of full flux penetration through bulk, thin films and multilayered superconductors. Our system combines a small superconducting solenoid which can generate the magnetic field up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the planner superconductor with 2 inch diameter. This setup was used to study alternative materials which could potentially outperform niobium, as well as SIS multilayer coatings on niobium.

Senevirathne, Iresha↗

Flux Expulsion and Material Properties of Niobium Explored in 644-650 MHz Cavities

Upcoming projects requiring high-Q ~650 MHz medium-to-high-${\beta}$ elliptical cavities drive a need to understand magnetic RF loss mechanisms and mitigations in greater detail. High-temperature annealing and fast-cooldowns have proven effective techniques for promoting magnetic flux expulsion in cavities, however the extent of their effectiveness has been observed to vary between niobium material lot and vendor. We explore the fast-cooldown method, and high-temperature annealing (900{\deg}C) in 644-650 MHz cavities fabricated from two different niobium vendors: Tokyo-Denkai, and Ningxia. which promote flux-expulsion efficiency. Using EBSD and PPMS methods, we aim to trace cavity flux expulsion efficiency to specific, measurable properties of the bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication, and can enable fine-tuning of cavity temperature treatments.

43 PARTICLE ACCELERATORS↗

Mode Damping Measurement for the APS Deflecting Cavity

The Advanced Photon Source has considered using a deflecting-cavity-based scheme to produce short pulse xrays. A deflecting cavity design has been completed. To verify the simulation result on this cavity, a copper prototype of the design has been fabricated for bench measurement. In this paper, we report our measurement results on this cavity. All the cavity modes below 5 GHz were identified by comparing the field distributions with calculations along different beam paths. After adding the damper, the measured Qexts of those modes were consistent with calculated values, which demonstrated that the cavity damping scheme was sufficient to reduce the wake impedances well below the safety thresholds.

Nassiri, A.↗

Time-Resolved Temperature Mapping System for the APS Deflecting Cavity

Time-resolved temperature mapping of a superconducting cavity can give valuable information on the limiting process of the cavity performance. A fast temperature mapping system has been developed at Argonne National Laboratory (ANL) for a superconducting deflecting cavity test. The time resolution of the temperature mapping could be up to 50 us. Not only the spatial distribution of surface heating but also the thermodynamics can be recorded, which helps to understand the limitation mechanism. This new temperature mapping system has helped us to understand the rf performance limitations during the cavity vertical tests. Based on the findings from the temperature mapping, proper cavity treatment has been applied and the cavity performances have been improved.

Nassiri, A.↗

First Results From Nb3Sn Coatings of 2.6 GHz Nb SRF Cavities Using DC Cylindrical Magnetron Sputtering System

A DC cylindrical magnetron sputtering system has been commissioned and operated to deposit Nb3Sn onto 2.6 GHz Nb SRF cavities. After optimizing the deposition conditions in a mock-up cavity, Nb-Sn films are deposited first on flat samples by multilayer sequential sputtering of Nb and Sn, and later annealed at 950°C for 3 hours. X-ray diffraction of the films showed multiple peaks for the Nb3Sn phase and Nb (substrate). No peaks from any Nb- Sn compound other than Nb3Sn were detected. Later three 2.6 GHz Nb SRF cavities are coated with ~1 μm thick Nb3Sn. The first Nb3Sn coated cavity reached close to Eacc = 8 MV/m, demonstrating a quality factor Q0 of $3.2 \times 108$ at Tbath = 4.4 K and Eacc = 5 MV/m, about a factor of three higher than that of Nb at this temperature. Q0 was close to $1.1 \times 109$, dominated by the residual resistance, at 2 K and Eacc = 5 MV/m. The Nb3Sn coated cavities demonstrated Tc in the range of $17.9 -- 18$ K. Here we present the commissioning experience, system optimization, and the first results from the Nb3Sn fabrication on flat samples and SRF cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Results from Nb3Sn Coatings of 2.6 GHz Nb SRF Cavities Using DC Cylindrical Magnetron Sputtering System

A DC cylindrical magnetron sputtering system has been commissioned and operated to deposit Nb3Sn onto 2.6 GHz Nb SRF cavities. After optimizing the deposition conditions in a mock-up cavity, Nb-Sn films are deposited first on flat samples by multilayer sequential sputtering of Nb and Sn, and later annealed at 950 {\deg}C for 3 hours. X-ray diffraction of the films showed multiple peaks for the Nb3Sn phase and Nb (substrate). No peaks from any Nb3Sn compound other than Nb3Sn were detected. Later three 2.6 GHz Nb SRF cavities are coated with ~1 $\mu$m thick Nb3Sn. The first Nb3Sn coated cavity reached close to Eacc = 8 MV/m, demonstrating a quality factor Q0 of 3.2 x 108 at Tbath = 4.4 K and Eacc = 5 MV/m, about a factor of three higher than that of Nb at this temperature. Q0 was close to 1.1 x 109, dominated by the residual resistance, at 2 K and Eacc = 5 MV/m. The Nb3Sn coated cavities demonstrated Tc in the range of 17.9 - 18 K. Here we present the commissioning experience, system optimization, and the first results from the Nb3Sn fabrication on flat samples and SRF cavities.

43 PARTICLE ACCELERATORS↗

Optimization of Ar/CL2 plasma parameters used for SRF cavity etching

We are pursuing the development of environmentally friendly dry etching of superconducting radio frequency (SRF) cavities in Ar/CL2 discharges. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after plasma etchings are equal to or better than wet etching processes. The plasma properties inside the single cell SRF cavity depend significantly on frequency, pressure and power. To understand the plasma properties and chemical kinetics of plasma etching process inside a single cell cavity, we are using a specially-designed cavity with 20 sample holders symmetrically distributed over the cell. These holders are being used for niobium coupon etching as well as diagnostic ports for optical measurements. Multiple optical probes with optical fibers have been utilized for emission spectroscopy measurements. A power supply in the radio frequency regime (100 MHz) and another power supply in the microwave frequency regime (2.45 GHz) are used to produce plasma inside the cavity. The plasma parameters at different pressures and power levels in combination with the analysis of the niobium sample etched will be used to determine the adequate frequency regime for plasma etching of Nb cavities.

Upadhyay, J.↗

Ultimate-Gradient SRF Test Cavity and Low Loss Tangent Measurements in Ultra Pure Sapphire

A test cavity has been designed to test wafer samples of superconducting materials at 1.3 GHz. Operating in TE01 mode, this mushroom shaped cavity creates a unique distribution of surface fields. The surface magnetic field on the sample wafer is 3.75 times greater than elsewhere on the Niobium (Nb) cavity surface. This made possible by loading the cavity with an ultra-pure sapphire just above the sample wafer. The maximum field seen by the Nb wall is only 25% of the value deposited on the sample surface. Therefore, it should be possible to push the sample wafer well beyond the BCS limit for Nb while still obtaining a respectable Q. The sapphire’s loss tangent and dielectric constant must be measured to finalize the design for the Wafer Test Cavity. A sapphire loaded CEBAF cavity has been constructed and tested; these results on the dielectric constant and loss tangent will be presented.

Pogue, Nathaniel↗