At least 739 records · Page 41

Monolayer CrCl 3 as an Ideal Test Bed for the Universality Classes of 2D Magnetism

The monolayer halides CrX 3 (X=Cl, Br, I) attract significant attention for realizing 2D magnets with genuine long-range order (LRO), challenging the Mermin-Wagner theorem. In this work, we show that monolayer CrCl 3 has the unique benefit of exhibiting tunable magnetic anisotropy upon applying a compressive strain. This opens the possibility to use CrCl 3 for producing and studying both ferromagnetic and antiferromagnetic 2D Ising-type LRO as well as the Berezinskii-Kosterlitz-Thouless (BKT) regime of 2D magnetism with quasi-LRO. Using state-of-the-art density functional theory, we explain how realistic compressive strain could be used to tune the monolayer's magnetic properties so that it could exhibit any of these phases. Building on large-scale quantum Monte Carlo simulations, we compute the phase diagram of strained CrCl 3 , as well as the magnon spectrum with spin-wave theory. Our results highlight the eminent suitability of monolayer CrCl 3 to achieve very high BKT transition temperatures, around 50 K, due to their singular dependence on the weak easy-plane anisotropy of the material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatiotemporal Crossover between Low- and High-Temperature Dynamical Regimes in the Quantum Heisenberg Magnet

The stranglehold of low temperatures on fascinating quantum phenomena in one-dimensional quantum magnets has been challenged recently by the discovery of anomalous spin transport at high temperatures. Whereas both regimes have been investigated separately, no study has attempted to reconcile them. For instance, the paradigmatic quantum Heisenberg spin-$1/2$ chain falls at low-temperature within the Tomonaga-Luttinger liquid framework, while its high-temperature dynamics is superdiffusive and relates to the Kardar-Parisi-Zhang universality class in $1+1$ dimensions. This work aims at reconciling the two regimes. Building on large-scale matrix product state simulations, we find that they are connected by a temperature-dependent spatiotemporal crossover. In this work, as the temperature $T$ is reduced, we show that the onset of superdiffusion takes place at longer length and time scales $\propto 1/T$. This prediction has direct consequences for experiments including nuclear magnetic resonance: it is consistent with earlier measurements on the nearly ideal Heisenberg $S=1/2$ chain compound Sr$_2$CuO$_3$ yet calls for new and dedicated experiments.

1-dimensional spin chains↗

Deeper Fluids

A framework for building and training neural network surrogates for CFD simulation, with a focus on quickly simulating volume fraction dynamics for carbon capture efficiency prediction. Augments the Deep Fluids (Kim et al., 2019) approach as described in our paper "Latent Space Simulation for Carbon Capture Design Optimization" (Bartoldson et al., 2021).

Nguyen, PhuocChanh N↗

ctrl-flow v0.0.1

ctrl-flow is a software that assists users in selecting a building control sequence from a library of control sequences that are implemented in the Modelica Buildings Library. The software allows selecting, configuring and editing the control sequences. It also allows exporting the sequence for use in building project design documents in Modelica-based simulations. The export will be in a json intermediate format, in the Modelica Language, in the Control Description Language and in English language format, such as in a Word document. The software functions as a web based application that includes a graphical user interface.

Wetter, Michael↗

hybridlane (fka CV-DV Quantum Circuit API)

This software package will abstract building a CV-DV quantum circuit for simulation and running on hardware. Existing simulation software each has their own API. This software intends to define a common API to be executed on several simulation and physical hardware backends.

Stavenger, Tim [Pacific Northwest National Laborat↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results and Responses for the 2022 User Forum Survey [Slides]

This presentation discusses the results of a MCNP user survey. Example of questions asked include: "Which MCNP particle types do you typically use?," "What sort of simulations do you run most often?," "Do you build the code?," "Which variance reduction methods do you use?," "Opinions on HDF5," with frequent discussions regarding each question.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Numerical Modeling & Optimization of the iProTech Pitching Inertial Pump (PIP) Wave Energy Converter (WEC) (CRADA Final Report)

This project represents a continuation of the collaboration between iProTech and NLR to simulate, optimize and design the iProTech Pitching Inertial Pump (PIP) device. The objectives of this TEAMER project are twofold: 1. Refining the physical characteristics of the existing iProTech PIP WEC-Sim model to enhance the model’s fidelity and include controllable components. Key model enhancements target the inclusion of Coulomb friction, the introduction of a controllable bypass valve, and the replacement of traditional check valves with advanced motorized ones. 2. Exploring traditional and advanced control algorithms. From traditional methods like latching control to cutting-edge reinforcement learning (RL) algorithms, the goal is to ensure the PIP device's adaptability and optimal performance across a range of ocean conditions. NLR is tasked with augmenting the WEC-Sim model and implementing the control algorithms, culminating in performance comparison analyses. iProTech will update their existing 3D models, advise on model improvements, and determine crucial system metrics. WEC-Sim, developed in MATLAB/SIMULINK with Simscape Multibody, is the main piece of software that will be used in this project. Coupled with the MATLAB RL Toolbox, it offers a robust platform for in-depth simulation and optimization of the iProTech PIP device. Building on previous work to explore the PIP design space and optimize its geometry, mass distribution, center of gravity and other key parameters, this project aims to refine iProTech’s existing numerical models and develop effective control algorithms that can seamlessly integrate into their future hardware testing campaigns.

16 TIDAL AND WAVE POWER↗

LBNL Fault Detection and Diagnostics Datasets

These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equipment (rooftop unit, single-duct air handler unit, dual-duct air handler unit, variable air volume box, fan coil unit, chiller plant, and boiler plant). Each dataset includes a .pdf file to document key information necessary to understand the content and scope, multiple csv files containing all the time-series data for faults at different severity levels and one fault-free case, and a ttl file to visualize the data according to BRICK schema. The dataset was created by LBNL, PNNL, NREL, ORNL and Drexel University.

AC↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL

The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of gallium nitride vertical fin-shaped field effect transistor for use as thermal neutron detector

Through the use of a radiation detection system simulation framework, a gallium nitride vertical fin-shaped field effect transistor (FinFET) was studied for output response when utilized as a thermal neutron detector. The FinFET was assumed to had been backfilled with boron carbide, reactive to thermal neutrons. The GaN FinFET was modeled with radiation transport from MCNP, and the electronic transport from COMSOL Multiphysics. Fabricated FinFET devices (not neutron reactive) were tested to aid in the tuning of the COMSOL FinFET model. Through time-depenent studies, the drain current response pulse to simulated ionization due to single events lead to building of a database of device responses to radiation. By integrating the current pulses over time, the induced charge was calculated. Using the results of the radiation transport PTRAC file in combination with the induced charge database, an integrated charge spectrum was calculated.

Davidson, Bryce L.↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Changes in polarization dictate necessary approximations for modeling electronic deexcitation intensity: Application to x-ray emission

Accurate simulation of electronic excitations and deexcitations are critical for complementing complex spectroscopic experiments and can provide validation to theoretical approaches. Here, using a generalized framework, we contrast the accuracy and validity of orbital-constrained and linear-response approaches that build upon Kohn-Sham density functional theory (DFT) to simulate emission spectra of electronic origin and propose an efficient approximation, named many-body x-ray emission spectroscopy or MBXES, for simulating such processes. We show analytically as well as with computed examples that for electronic (de)excitation leading to an appreciable change in polarization (i.e., density rearrangement), the adiabatic approximation in a response-based formalism will be inadequate for the calculation of oscillator strength. Thus, such a change (e.g., in the net electrostatic dipole moment of a finite system) can be used as a metric for evaluating the applicability of the adiabatic response-based approach and can be particularly valuable in x-ray emission spectroscopy. On the other hand, MBXES, the flexible method introduced in this paper, can compute oscillator strengths accurately at a much lower computational expense on the basis of two DFT-based self-consistent field calculations. Using illustrative examples of emission spectra, the efficacy of the MBXES method is demonstrated by comparison with its parent theory, orbital-optimized DFT, and with experiments.