At least 739 records · Page 41

Fast Equilibration of Hadrons in an Expanding Fireball

Because of long chemical equilibration times for standard hadronic reactions in a hadron gas in relativistic heavy ion collisions, it was suggested that hadrons are born into equilibrium after the quark gluon plasma is formed. We develop a dynamical scheme, using master equations, in which Hagedorn states contribute to fast chemical equilibration times of baryons and kaons, just below the critical temperature, estimates of which are derived analytically. The hadrons quickly equilibrate for an initial over- or underpopulation of Hagedorn states. Our particle ratios compared to BNL Relativistic Heavy Ion Collider show a close match.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Perturbative QCD Calculations of Elliptic Flow and Shear Viscosity in Au+Au Collisions at {radical}(s{sub NN})=200 GeV

The elliptic flow v{sub 2} and the ratio of the shear viscosity over the entropy density, {eta}/s, of gluon matter are calculated from the perturbative QCD (pQCD) based parton cascade Boltzmann approach of multiparton scatterings. For Au+Au collisions at {radical}(s)=200A GeV the gluon plasma generates large v{sub 2} values measured at the BNL Relativistic Heavy Ion Collider. Standard pQCD yields {eta}/s{approx_equal}0.08-0.15 as small as the lower bound found from the anti-de Sitter/conformal field theory conjecture.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Magnetic Component of Quark-Gluon Plasma is also a Liquid

The magnetic scenario for strongly coupled quark-gluon plasma (sQGP) emphasizes the role of monopoles near or above the deconfinement temperature, and specifically predicts that they help reduce its viscosity by the 'magnetic bottle' effect. Here we present results for monopole-(anti)monopole correlation functions from our classical molecular dynamics simulations, which are in good agreement with the lattice results. By analysis of the correlation functions, we show that the magnetic Coulomb coupling runs in the direction opposite to the electric one. However, as T decreases to T{sub c}, the magnetic coupling never gets too weak, with the plasma parameter always large enough ({gamma}>1). This nicely agrees with empirical evidence from the BNL Relativistic Heavy Ion Collider experiments, implying that magnetic objects should also form a good liquid with low viscosity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Consistent Anti-de Sitter-Space/Conformal-Field-Theory Dual for a Time-Dependent Finite Temperature System

We propose a consistent setup for the holographic dual of the strongly coupled large-N{sub c} N=4 super Yang-Mills theory plasma which undergoes the Bjorken flow relevant to the quark-gluon plasma at BNL Relativistic Heavy Ion Collider and CERN LHC. The dual geometry is constructed order by order in a well-defined late-time expansion. The transport coefficients are determined by the regularity of the geometry. We prove, for the first time, that the dual geometry has an apparent horizon, hence, an event horizon, which covers a singularity at the origin. Further we prove that the dual geometry is regular to all orders in the late-time expansion under an appropriate choice of the transport coefficients. This choice is also shown to be unique. Our model serves as a concrete well-defined example of a time-dependent anti-de Sitter-space/conformal-field-theory dual.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Di-Jet Conical Correlations Associated with Heavy Quark Jets in anti-de Sitter Space/Conformal Field Theory Correspondence

We show that far zone Mach and diffusion wake 'holograms' produced by supersonic strings in anti-de Sitter space/conformal field theory (AdS/CFT) correspondence do not lead to observable conical angular correlations in the strict N{sub c}{yields}{infinity} supergravity limit if Cooper-Frye hadronization is assumed. However, a special nonequilibrium 'neck' zone near the jet is shown to produce an apparent sonic boom azimuthal angle distribution that is roughly independent of the heavy quark's velocity. Our results indicate that a measurement of the dependence of the away-side correlations on the velocity of associated identified heavy quark jets at the BNL Relativistic Heavy Ion Collider and CERN LHC will provide a direct test of the nonperturbative dynamics involved in the coupling between jets and the strongly coupled quark-gluon plasma implied by AdS/CFT correspondence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incoherent effect of space charge and electron cloud

Trapping by resonances or scattering off resonances induced by space charge (SC) or electron cloud (EC) in conjunction with synchrotron motion can explain observations of slow beam loss and emittance growth, which are often accompanied by changes in the longitudinal beam profile. In this paper we review the recent progress in understanding and modeling of the underlying mechanisms, highlight the differences and similarities between space charge and electron cloud, and discuss simulation results in the light of experimental observations, e.g., at GSI, CERN, and BNL. In particular, we address the role of the pinched electrons and describe in detail the complexity of the electron pinch formation. We present simulation results within a dipole or in a field-free region of the beam pipe, which reveal the morphology and main features of this phenomenon, explain the physical origin of the complex electron structures like stripe in either field configuration, and discuss the dependence on some key parameters.

43 PARTICLE ACCELERATORS↗

Results of the SLAC LCLS Gun High-Power RF Tests

The beam quality and operational requirements for the Linac Coherent Light Source (LCLS) currently being constructed at SLAC are exceptional, requiring the design of a new RF photocathode gun for the electron source. Based on operational experience at SLAC's GTF and SDL and ATF at BNL as well as other laboratories, the 1.6cell s-band (2856MHz) gun was chosen to be the best electron source for the LCLS, however a significant redesign was necessary to achieve the challenging parameters. Detailed 3-D analysis and design was used to produce near-perfect rotationally symmetric rf fields to achieve the emittance requirement. In addition, the thermo-mechanical design allows the gun to operate at 120Hz and a 140MV/m cathode field, or to an average power dissipation of 4kW. Both average and pulsed heating issues are addressed in the LCLS gun design. The first LCLS gun is now fabricated and has been operated with high-power RF. The results of these high-power tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

R&D Energy Recovery Linac at Brookhaven National Laboratory

Collider Accelerator Department at BNL is in the final stages of developing the 20-MeV R&D energy recovery linac with super-conducting 2.5 MeV RF gun and single-mode super-conducting 5-cell RF linac. This unique facility aims to address many outstanding questions relevant for high current (up to 0.5 A of average current), high brightness energy-recovery linacs with novel Zigzag-type merger. We present the performance of the R&D ERL elements and detailed commissioning plan.

43 PARTICLE ACCELERATORS↗

Final Development and test preparation of the first 3.7m long Nb3Sn quadrupole by LARP

The test of the first LARP (LHC Accelerator Research Program) Long Quadrupole is a significant milestone toward the development of Nb{sub 3}Sn quadrupoles for LHC (Large Hadron Collider) Luminosity Upgrades. These 3.7-m long magnets, scaled from the 1-m long Technological Quadrupoles, are used to develop our capabilities to fabricate and assemble Nb{sub 3}Sn coils and structures with lengths comparable to accelerator magnet dimensions. The long quadruples have a target gradient of 200 T/m in a 90-mm aperture. Pre-stress and support are provided by an Al-shell-based structure pre-loaded using bladders and keys. The coils were fabricated at BNL and FNAL, the shell-based structure was designed and assembled at LBNL, the test is performed at FNAL. In this paper we present the final steps of the development of the first model (LQS01), several upgrades to the test facility, the test results of witness cables, and the short sample limit.

43 PARTICLE ACCELERATORS↗

Effect of Barrel Material on Critical Current Measurements of High-Jc RRP Nb3Sn Wires

Nb{sub 3}Sn strands extracted from a 20-strand rectangular Rutherford cable were reacted on either stainless steel or Ti-alloy barrels and the critical current, I{sub c}, in the field range of 8-11.5 T was measured on ITER-type barrels made from Ti-6Al-4V alloy, 304 stainless steel and G-10. Measurements on the 'standard' Ti-alloy barrel using the test procedure employed at BNL are shown to reproduce I{sub c} for extracted strands to {+-}2%. The I{sub c} data for the sample mounted on the 'standard' Ti-alloy are fit to the deviatoric strain scaling model developed for Nb{sub 3}Sn by the University of Twente group using an arbitrary pre-strain. Using the parameters for this fit, the I{sub c} data for the other barrels are fitted by only adjusting the strain. Using this procedure, the strain difference due to the barrel material is determined. Assuming a thermal pre-strain of -0.2% for the sample measured on the Ti-alloy barrel, the use of stainless steel barrel increases the compressive strain by -0.07%, that of G-10 by -0.10%. With the wire soldered to the stainless steel barrel, the strain increases to -0.15%. Details of this study are presented.

36 MATERIALS SCIENCE↗

Hand-Held Gamma-Ray Spectrometer Based on High-Efficiency Frisch-Ring Cdznte Detectors

Frisch-ring CdZnTe detectors have demonstrated both good energy resolution, <1% FWHM at 662 keV, and good efficiency in detecting gamma rays, highlighting the strong potential of CdZnTe materials for such applications. We are designing a hand-held gamma-ray spectrometer based on Frisch-ring detectors at Brookhaven National Laboratory. It employs an 8 times 8 CdZnTe detector array to achieve a high volume of 19.2 cm3, so greatly improving detection efficiency. By using the front-end application-specific integrated circuits (ASICs) developed at BNL, this spectrometer has a small profile and high energy-resolution. It includes a signal processing circuit, digitization and storage circuits, a high-voltage module, and a universal serial bus (USB) interface. In this paper, we detail the system's structure and report the results of our tests with it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Small-Scale Readout System Prototype for the STAR PIXEL Detector

Development and prototyping efforts directed towards construction of a new vertex detector for the STAR experiment at the RHIC accelerator at BNL are presented. This new detector will extend the physics range of STAR by allowing for precision measurements of yields and spectra of particles containing heavy quarks. The innermost central part of the new detector is a high resolution pixel-type detector (PIXEL). PIXEL requirements are discussed as well as a conceptual mechanical design, a sensor development path, and a detector readout architecture. Selected progress with sensor prototypes dedicated to the PIXEL detector is summarized and the approach chosen for the readout system architecture validated in tests of hardware prototypes is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo dose enhancement studies in microbeam radiation therapy

Purpose: A radical radiation therapy treatment for gliomas requires extremely high absorbed doses resulting in subsequent deleterious side effects in healthy tissue. Microbeam radiation therapy (MRT) is an innovative technique based on the fact that normal tissue can withstand high radiation doses in small volumes without any significant damage. The synchrotron-generated x-ray beam is collimated and delivered to an array of narrow micrometer-sized planar rectangular fields. Several preclinical experiments performed at the Brookhaven National Laboratory (BNL) and at the European Synchrotron Radiation Facility (ESRF) confirmed that MRT yields a higher therapeutic index than nonsegmented beams of the same characteristics. This index can be greatly improved by loading the tumor with high atomic number (Z) contrast agents. The aim of this work is to find the high-Z element that provides optimum dose enhancement. Methods: Monte Carlo simulations (PENELOPE/penEasy) were performed to assess the peak and valley doses as well as their ratio (PVDR) in healthy tissue and in the tumor, loaded with different contrast agents. The optimization criteria used were maximization of the ratio between the PVDR values in healthy tissue respect to the PVDR in the tumor and minimization of bone and brain valley doses. Results: Dose enhancement factors, PVDR, and valley doses were calculated for different high-Z elements. A significant decrease of PVDR values in the tumor, accompanied by a gain in the valley doses, was found in the presence of high-Z elements. This enables the deposited dose in the healthy tissue to be reduced. The optimum high-Z element depends on the irradiation configuration. As a general trend, the best outcome is provided by the highest Z contrast agents considered, i.e., gold and thallium. However, lanthanides (especially Lu) and hafnium also offer a satisfactory performance. Conclusions: The remarkable therapeutic index in microbeam radiation therapy can be further improved by loading the tumor with a high-Z element. This study reports quantitative data on several dosimetric magnitudes in order to find the optimum contrast agent. Although the final choice of the element will also depend on possible cytotoxicity, three elements were found to be worthy of mention: gold, thallium, and lutetium.

61 RADIATION PROTECTION AND DOSIMETRY↗

Searches for heavy neutrinos in the decays of positively charged kaons

According to predictions of the {nu}MSM model, a heavy neutrino may exist in the mass range below 1 GeV. Searches for rare kaon decays make it possible to study the heavy-neutrino-mass range M{sub {pi}} < m{sub {nu}H} < M{sub K}. A preliminary analysis of data from the E949 experiment performed at the Brookhaven National Laboratory (BNL, USA) is performed in the present study. Basic background processes are studied, and it is shown that a sensitivity at a level of 4 Multiplication-Sign 10{sup -8} to the K{sup +} {yields} Micro-Sign {sup +}{nu}{sub H} branching ratio can be reached for the mass value of m{sub {nu}H} = 250 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Paving the way to personalized medicine: production of some theragnostic radionuclides at Brookhaven National Laboratory

This paper introduces a relatively novel paradigm that involves specific individual radionuclides or radionuclide pairs that have emissions that allow pre-therapy low-dose imaging plus higher-dose therapy in the same patient. We have made an attempt to sort out and organize a number of such theragnostic radionuclides and radionuclide pairs that may potentially bring us closer to the age-long dream of personalized medicine for performing tailored low-dose molecular imaging (SPECT/CT or PET/CT) to provide the necessary pre-therapy information on biodistribution, dosimetry, the limiting or critical organ or tissue, and the maximum tolerated dose (MTD), etc. If the imaging results then warrant it, it would be possible to perform higher-dose targeted molecular therapy in the same patient with the same radiopharmaceutical. A major problem that remains yet to be fully resolved is the lack of availability, in sufficient quantities, of a majority of the best candidate theragnostic radionuclides in a no-carrier-added (NCA) form. A brief description of the recently developed new or modified methods at BNL for the production of four theragnostic radionuclides, whose nuclear, physical, and chemical characteristics seem to show great promise for personalized cancer therapy are described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Report on INL Activities for UncertaintyReduction Analysis of FY10

The work scope of this project related to the Work Packages of “Uncertainty Reduction Analyses” with the goal of reducing nuclear data uncertainties is to produce a set of improved nuclear data to be used both for a wide range of validated advanced fast reactor design calculations, and for providing guidelines for further improvements of the ENDF/B files (i.e. ENDF/B-VII, and future releases). This report presents the status of activities performed at INL under the FC R&D Work Package previously mentioned. First an analysis of uncertainty evaluation is presented using the new covariance data (AFCI version 1.2) made available by BNL. Then, analyses of a number of experiments, among those selected in the previous fiscal year and available, are presented making use of ENDF/B-VII data. These experiments include: updating of the ZPR-6/7 assembly (improved model and spectral indices), ZPPR-9 assembly (only simplified model available), ZPPR-10 (full detailed model), and irradiation experiments. These last experiments include PROFIL-1 were a new methodology has been employed in the Monte Carlo calculations, and also a deterministic analysis has been performed. This is the first time the Monte Carlo approach and ENDF/B-VII have been used for the PROFIL experiments. The PROFIL-2 and TRAPU experiments have been for the moment only modeled and a full analysis of the irradiation results will be finalized next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

R&D PROPOSAL FOR THE NATIONAL MUON ACCELERATOR PROGRAM

This document contains a description of a multi-year national R&D program aimed at completing a Design Feasibility Study (DFS) for a Muon Collider and, with international participation, a Reference Design Report (RDR) for a muon-based Neutrino Factory. It also includes the supporting component development and experimental efforts that will inform the design studies and permit an initial down-selection of candidate technologies for the ionization cooling and acceleration systems. We intend to carry out this plan with participants from the host national laboratory (Fermilab), those from collaborating U.S. national laboratories (ANL, BNL, Jlab, LBNL, and SNAL), and those from a number of other U.S. laboratories, universities, and SBIR companies. The R&D program that we propose will provide the HEP community with detailed information on future facilities based on intense beams of muons--the Muon Collider and the Neutrino Factory. We believe that these facilities offer the promise of extraordinary physics capabilities. The Muon Collider presents a powerful option to explore the energy frontier and the Neutrino Factory gives the opportunity to perform the most sensitive neutrino oscillation experiments possible, while also opening expanded avenues for the study of new physics in the neutrino sector. The synergy between the two facilities presents the opportunity for an extremely broad physics program and a unique pathway in accelerator facilities. Our work will give clear answers to the questions of expected capabilities and performance of these muon-based facilities, and will provide defensible ranges for their cost. This information, together with the physics insights gained from the next-generation neutrino and LHC experiments, will allow the HEP community to make well-informed decisions regarding the optimal choice of new facilities. We believe that this work is a critical part of any broad strategic program in accelerator R&D and, as the P5 panel has recently indicated, is essential for the long-term health of high-energy physics.

43 PARTICLE ACCELERATORS↗

Single pass electron beam cooling of gold ions between EBIS LINAC and booster is theoretically possible!

Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Many issues, regarding a low energy high current electron beam that is needed for electron beam cooling to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster, were examined. Computations and some experimental data indicate that none of these issues is a show stopper. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in about one meter. Hence, this option cooling deserves further more serious considerations.

43 PARTICLE ACCELERATORS↗