Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Argon pumpout by ICRF waves in C-Mod L- and I-mode plasmas

Pumpout of argon ions by ICRF waves has been observed in C-Mod deuterium L- and I-mode plasmas that had a substantial hydrogen fraction. The effect is manifested by a reduction of core argon x-ray brightness up to a factor of 90% on time scales of tens of milliseconds following injection of ICRF power. For Ar 16+ , the pumpout is strongest for hydrogen minority concentrations between 0.25 and 0.4, when the ICRF waves are not expected to result in minority heating. Modeling with the TORIC code suggests that the pumpout process occurs when the H/D mode conversion layer overlaps with the 2nd harmonic impurity resonance layer. Here, the magnitude of the argon pumpout is independent of ICRF power above an apparent threshold of ~500 kW, independent of electron density and appears to decrease as the plasma current is increased. Potential application as a heavy impurity control tool in reactors is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric study of Alfvénic instabilities driven by runaway electrons during the current quench in DIII-D

Abstract To avoid or mitigate runaway electron (RE) beams in ITER, RE-driven instabilities are actively studied as a complimentary technique to massive material injection. In this work we report experimental dependencies of Alfvénic instabilities driven by REs during the current quench in DIII-D on plasma and material injection parameters. These instabilities, observed in the frequency range of 0.1–3 MHz, correlate with increased RE loss and thus may play a role in non-sustained RE beams. It was found that as the toroidal magnetic field ( B T ) decreases, the RE population becomes more energetic, the energy of instabilities increases, and no RE beam is observed when the maximum energy of REs exceeds 15 MeV (or when B T is below 1.8 T). Analysis of disruptions at plasma core temperature ( T e ) of 1 keV and 8 keV shows that the RE population is much less energetic (with the maximum energy of only about 3 MeV) when T e is high, and no instabilities are observed in this case. Besides disruptions above caused by Ar injection, cases with Ne and D 2 injections were also studied. Both Ne and D 2 injections cause no sustained RE beams, however, for different reasons. Measurements of the instability polarization indicate that it is of predominantly compressional nature at the edge, which is consistent with modeling suggesting excitation of compressional Alfvén eigenmodes. However, drive of global Alfvén eigenmodes is also possible at low frequencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of physics results from the ADITYA-U tokamak and future experiments

The ADITYA upgrade (ADITYA-U), a medium-sized (R 0 = 75 cm, a = 25 cm) conventional tokamak facility in India, has been consistently producing experiments findings by usingcircular and shaped-plasmas. Recognizing the plasma parameters aligning closely with the design parameters of circular limited plasmas, ADITYA-U shifted its focus toward exploring the operational regime for experimentation on saw-tooth and MHD phenomena. Moreover, ADITYA-U has made consistent advancements toward conducting preliminary plasma shaping experiments through the activation of top and bottom divertor coils utilizing hydrogen as well as deuterium fuels. Confinement is improved by a factor of ~1.5 in D 2 plasmas when compared to H 2 plasmas of ADITYA-U. Further, ADITYA-U operations emphasize preventing disruptions and runaway electrons (REs) to ensure safe operations for future fusion devices. Significant suppression of REs has been achieved in ADITYA-U with the application of pulsed localized vertical magnetic field (LVF) perturbation, thereby establishing the technique's independence from the tokamak device. The successful RE mitigation requires a critical threshold of LVF pulse magnitude, which is approximately 1% of the toroidal magnetic field, and a minimum duration of ~5 ms. Apart from this, several novel findings have been achieved in the ADITYA-U experiments, including the modification of sawtooth duration through gas-puff, the emergence of MHD-induced geodesic acoustic mode-like oscillations, the propagation of fast heat pulses induced by MHD activity, the control of RE dynamics through Gas-puffs, the propagation of pinch-driven cold-pulses, the transport and core accumulations of argon impurities, the mass dependency of plasma toroidal rotation and the detection of 'RICE' scaling, as well as the characterization of edge plasma using wall conditioning methods, such as glow discharge cleaning using a combination of Ar-H 2 mixture, localized wall cleaning by electron cyclotron resonant plasma, and the development of machine learning-based disruption predictions, will be discussed in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The impact of helium on plasma-driven hydrogen permeation and implications for direct internal recycling in the fusion fuel cycle

Abstract Metal foil pumps (MFPs) are the leading technology for direct internal recycling (DIR) of hydrogen isotopes from the plasma exhaust in future fusion plants. MFPs rely on the concept of superpermeation, where superthermal H atoms directly absorb into the metal foil, rapidly diffuse, and desorb downstream. To date, studies of superpermeation have predominantly employed either pure hydrogen or in some cases trace levels of impurities. The plasma exhaust is expected to contain just ∼1% helium, but in DIR the source gas would be enriched in helium as hydrogen isotopes are extracted. In this work, we explore the impact of helium on hydrogen superpermeation at low temperature (75 °C–200 °C) using Pd-based foils. To first order, the flux scaled linearly with the hydrogen mole fraction. Stable permeation was observed until the helium fraction reached ∼80%, where the flux began to decline slowly with time. In addition, short term (1–5 min) exposure to pure helium plasma significantly attenuated subsequent hydrogen plasma permeation, and the degree was more dramatic at elevated temperature. This attenuation was correlated with He retention in the foils, which was detected by time-of-flight secondary ion mass spectrometry at low levels (<0.1 at. %) and limited to the near surface (<10 nm). Similar trends were observed among all alloys (Pd, PdAg, PdCu), and the foils were restored to full performance with an Ar + sputter clean. The potential for helium plasma exposure to impact MFP performance under these conditions has not been previously reported, and these findings have significant implications to the design and implementation of practical DIR systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid Argon Time Projection Chamber Trigger Development with MicroBooNE

The Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) neutrino detector at Fermilab that has been operating since 2015. It aims to perform v-Ar cross-section measurements, explore the low-energy excess reported by the MiniBooNE experiment and perform a combined search for sterile neutrino oscillations as part of three LArTPCs that make up the Short Baseline Neutrino (SBN) Program at Fermilab. Since MicroBooNE is currently in an R&D phase, it offers a unique opportunity for the implementation and testing of TPC-based triggers as R&D towards the Deep Underground Neutrino Experiment (DUNE). One of the technical challenges of DUNE that we aim to address with this study is that of efficient self-triggering of a LArTPC utilizing TPC signal information. This capability will enable searches for rare processes in DUNE, such as neutrino interactions from a potential galactic supernova burst. This talk will describe the MicroBooNE TPC readout system and ongoing R&D efforts to develop and demonstrate TPC-based triggering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 83 mKr source for the calibration of the CENNS-10 liquid argon detector

We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. Lastly, we performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV.

47 OTHER INSTRUMENTATION↗

A hybrid 3D/2D field response calculation for liquid argon detectors with PCB based anode plane

Liquid Argon Time Projection Chamber (LArTPC) technology is commonly utilized in neutrino detector designs. It enables detailed reconstruction of neutrino events with high spatial precision and low energy threshold. Its field response (FR) model describes the time-dependent electric currents induced in the anode-plane electrodes when ionization electrons drift nearby. An accurate and precise FR is a crucial input to LArTPC detector simulations and charge reconstruction. Established LArTPC designs have been based on parallel wire planes. It allows accurate and computationally economic two-dimensional (2D) FR models utilizing the translational symmetry along the direction of the wires. Recently, novel LArTPC designs utilize electrodes formed on printed circuit board (PCB) in the shape of strips with through holes. The translational symmetry is no longer a good approximation near the electrodes and a new FR calculation that employs regions with three dimensions (3D) has been developed. Extending the 2D models to 3D would be computationally expensive. Fortuitously, the nature of strips with through holes allows for a computationally economic approach based on the finite-difference method (FDM). In this paper, we present a new software package pochoir that calculates LArTPC field response for these new strip-based anode designs. This package combines 3D calculations in the volume near the electrodes with 2D far-field solutions to achieve fast and precise field response computation. We apply the resulting FR to simulate and reconstruct samples of cosmic-ray muons and 39 Ar decays from a Vertical Drift (VD) detector prototype operated at CERN. We find the difference between real and simulated data within 5%. Current state-of-the-art LArTPC software requires a 2D FR which we provide by averaging over one dimension and estimate that variations lost in this average are smaller than 7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

The XRISM first-light observation: Velocity structure and thermal properties of the supernova remnant N 132D

Abstract We present an initial analysis of the X-Ray Imaging and Spectroscopy Mission (XRISM) first-light observation of the supernova remnant (SNR) N 132D in the Large Magellanic Cloud. The Resolve microcalorimeter has obtained the first high-resolution spectrum in the 1.6–10 keV band, which contains K-shell emission lines of Si, S, Ar, Ca, and Fe. We find that the Si and S lines are relatively narrow, with a broadening represented by a Gaussian-like velocity dispersion of $\sigma _v \sim 450$ km s$^{-1}$. However, the Fe He$\alpha$ lines are substantially broadened with $\sigma _v \sim 1670$ km s$^{-1}$. This broadening can be explained by a combination of the thermal Doppler effect due to the high ion temperature and the kinematic Doppler effect due to the SNR expansion. Assuming that the Fe He$\alpha$ emission originates predominantly from the supernova ejecta, we estimate the reverse shock velocity at the time when the bulk of the Fe ejecta were shock heated to be $-1000 \lesssim V_{\rm rs}$ (km s$^{-1}$) $\lesssim 3300$ (in the observer frame). We also find that Fe Ly$\alpha$ emission is redshifted with a bulk velocity of $\sim 890$ km s$^{-1}$, substantially larger than the radial velocity of the local interstellar medium surrounding N 132D. These results demonstrate that high-resolution X-ray spectroscopy is capable of providing constraints on the evolutionary stage, geometry, and velocity distribution of SNRs.

individual objects↗

Outflowing photoionized plasma in Circinus X-1 using the high-resolution X-ray spectrometer Resolve onboard XRISM and the radiative transfer code cloudy

High-resolution X-ray spectroscopy is a key to understanding the mass inflow and outflow of compact objects. Spectral lines carry information about the ionization, density, and velocity structures through their intensity ratios and profiles. They are formed in non-local thermodynamic equilibrium conditions under the intense radiation field from the compact objects; thus radiative transfer (RT) calculation is a requisite for proper interpretations. We present such a study for a low-mass X-ray binary, Circinus X-1, from which the P Cygni profile was discovered using the X-ray grating spectrometer onboard Chandra. We observed the source using the X-ray microcalorimeter onboard XRISM at an orbital phase of 0.93–0.97 and revealed many spectral features unidentified before: the higher series transitions ($n{\rightarrow }1$; $n>2$) of highly ionized (H- and He-like) S, Ca, Ar, and Fe in emission and absorption, the Fe K$\alpha$ and K$\beta$ inner-shell excitation absorption of mildly ionized (O- to Li-like) Fe, and resolved fine-structure level transitions in the Fe Ly$\alpha$ and He$\alpha$ complexes. They blend with each other at different velocity shifts on top of apparently variable continuum emission that changed its flux by an order of magnitude within a 70 ks telescope time. Despite such complexity in the observed spectra, most of them can be explained by a simple model consisting of the photoionized plasma outflowing at $\sim$300 km s$^{-1}$ and the variable blocking material in the line of sight of the incident continuum emission from the accretion disk. We demonstrate this with the aid of the RT code cloudy for the line ratio diagnostics and spectral fitting. We further constrain the physical parameters of the outflow and argue that the outflow is launched close to the outer edge of the accretion disk and can be driven radiatively by being assisted by the line force calculated using the RT simulation.

X-rays: binaries↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics↗

Hooks versus Pedicle Screws at the Upper Instrumented Level: An In Vitro Biomechanical Comparison

Study Design. Controlled laboratory study Objective. To compare motions at the upper instrumented vertebra (UIV) and supra-adjacent level (UIV+1) between two fixation techniques in thoracic posterior spinal fusion (PSF) constructs. We hypothesized there would be greater motion at UIV+1 after cyclic loading across all constructs and bilateral pedicle screws (BPS) with posterior ligamentous compromise would demonstrate the greatest UIV+1 range of motion (ROM). Summary of Background Data. Proximal junctional kyphosis (PJK) is a well-recognized complication following long thoraco-lumbar PSF, however its mechanism is poorly understood. Methods. Twenty-seven thoracic functional spine units (FSU) were randomly divided into three UIV fixation groups (n=9): (1) BPS, (2) bilateral transverse process hooks (TPH), and (3) BPS with compromise of the posterior elements between UIV and UIV+1 (BPS-C). Specimens were tested on a servohydraulic materials testing system in native state, following instrumentation, and after cyclic loading. FSUs were loaded in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Results. After cyclic testing, the TPH group had a mean 29.4% increase in FE ROM at UIV+1 versus 76.6% in the BPS group ( P <0.05). The BPS-C group showed an increased FE of 49.9% and 62.19% with sectioning of the facet joints and interspinous ligament respectively prior to cyclic testing. Conclusion. Bilateral pedicle screws at the UIV led to greater motion at UIV+1 compared to bilateral TPH after cyclic loading. This is likely due to the increased rigidity of BPS compared to TPH leading to a “softer” transition between the TPH construct and native anatomy at the supra-adjacent level. Facet capsule compromise led to a 49.9% increase in UIV+1 motion, underscoring the importance of preserving the posterior ligamentous complex. Clinical studies that account for fusion rates are warranted to determine if constructs with a “soft transition” result in less PJK in vivo.

Neurosciences & Neurology↗

Advancing quantum simulations of the nuclear shell model with Gray-code–based resource-efficient protocols

Background: Some of the computational limitations in solving the nuclear many-body problem could be overcome by utilizing quantum computers. The nuclear shell-model calculations providing deeper insights into the properties of atomic nuclei are one such case with high demand for resources, as the size of the Hilbert space grows exponentially with the number of particles involved. Quantum algorithms are being developed to overcome these challenges and advance such calculations. Purpose: To develop quantum circuits for the nuclear shell-model, leveraging the capabilities of noisy intermediate-scale quantum (NISQ) devices. Here, we aim to minimize resource requirements (specifically in terms of qubits and gates) and strive to reduce the impact of noise by employing relevant mitigation techniques. Methods: We achieve noise resilience by designing an optimized Ansatz for the variational quantum eigensolver (VQE) based on Givens rotations and incorporating qubit-ADAPT-VQE in combination with variational quantum deflation (VQD) to compute ground and excited states, incorporating the zero-noise extrapolation mitigation technique. Furthermore, the qubit requirements are significantly reduced by mapping the basis states to qubits using Gray-code encoding and generalizing transformations of fermionic operators to efficiently represent many-body states. Results: By employing the resource-efficient protocols, we achieve the ground and excited state energy levels of 38 Ar and 6 Li with better accuracy. These energy levels are presented for noiseless simulations, noisy conditions, and after applying noise mitigation techniques. Results are compared for Jordan-Wigner and Gray-code encoding using VQE, qubit-ADAPT-VQE, and VQD. Conclusions: Our work highlights the potential of resource-efficient protocols to leverage the full potential of NISQ devices in scaling the nuclear shell model calculations, offering a pathway toward more complex quantum simulations in nuclear physics. This approach establishes a framework for studying other nuclear systems with improved quantum resource efficiency, marking a significant advancement in applying quantum computing to realistic nuclear physics applications.

Physics - Nuclear physics and radiation physics↗

Anomalous ellipticity dependence of the generation of near-threshold harmonics in noble gases

We measured the ellipticity dependence of the harmonic yield of He, Ne, Ar, Kr, and Xe. It is found that the harmonic yield in general decreases monotonically with increasing laser ellipticity but anomalous dependence does occur for each atom for some harmonic orders. Additionally, we found that the degree of anomaly is weakest in helium but is stronger for the heavier atoms. The anomaly also depends on laser intensity. To explain these features, we developed a quantum trajectory Monte Carlo (QTMC) model based on the quantum path integral theory to study high-order harmonic generation (HHG). The model includes the effect of Coulomb potential from the target ion, thus it is capable of calculating near-threshold harmonics quantitatively. This model reveals that the presence of Coulomb potential would generate orbiting trajectories which are responsible for the anomalous ellipticity dependence near the threshold.

74 ATOMIC AND MOLECULAR PHYSICS↗

Pulse shaping in strong-field ionization: Theory and experiments

Intense ultrafast pulses cause dissociative ionization and shaping the pulses may allow control of both electronic and nuclear dynamics that determine ion yields. We report on a combined experimental and theoretical effort to determine how shaped laser pulses affect tunnel ionization, the process that precedes many strong-field phenomena. We carried out experiments on Ar, N 2 , H 2 O, and O 2 using a phase-step function of amplitude 3/4π that is scanned across the spectrum of the pulse. In addition, we changed the amount of chirp in the pulses. Semiclassical as well as fully quantum mechanical time-dependent Schrödinger equation calculations are found to be in excellent agreement with experimental results. We find that precise knowledge of the field parameters in the time and frequency domains is essential to afford reproducible results and quantitative theory and experiment comparisons.

74 ATOMIC AND MOLECULAR PHYSICS↗