Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

The burden of ischemic heart disease related to ambient air pollution exposure in a coastal city in South China

Highlights: • Burden of ischemic heart disease related to PM{sub 2.5}, SO{sub 2} and NO{sub 2} were estimated. • Stronger impacts of gaseous pollutants versus particulate matter were found. • SO{sub 2} exposure was positively associated with YLL in widowed group. Air pollution is considered one of the most important risk factors for ischemic heart disease (IHD), which is a major public health concern. The disease burden of IHD has continued to rise in China in the past two decades. However, epidemiological studies examining the associations between air pollution and IHD have been scarce in China, and the only studies were conducted in severe air pollution areas, where air pollution levels seriously exceed the World Health Organization Air Quality Guidelines. Whether the influence of air pollution on IHD in areas with relatively low levels of air pollution differs from the influence of high pollution levels in heavily studied areas was unknown until now. Furthermore, the estimation of the disease burden of IHD related to air pollution has been very limited.

54 ENVIRONMENTAL SCIENCES↗

Pollution inequality 50 years after the Clean Air Act: the need for hyperlocal data and action

Fifty years ago the Clean Air Act amendments of 1970 were the first major US legislation that authorized regulation of air pollutants, creating National Ambient Air Quality Standards (NAAQSs) to protect public health and the environment. While US air quality has improved, with average PM 2.5 concentrations in 2016 a third of 1981 levels, air pollution remains a major health risk in the US and globally. Moreover, air pollution impacts are still uneven, with the most polluted US communities of 50 years ago still so today. Air pollution “hot spots” result in disproportionate exposure at neighborhood scales within cities, particularly in disadvantaged communities, but an in-depth understanding at these scales is lacking. This policy perspective discusses how trends in sensor technology, spatial data collection, analytics and retrieval are converging to enable the production of hyperlocal air pollution data, and that this needs to be done in a manner that enables marginalized communities to shape decision making.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pathways of China's PM 2.5 air quality 2015–2060 in the context of carbon neutrality

Clean air policies in China have substantially reduced particulate matter (PM 2.5 ) air pollution in recent years, primarily by curbing end-of-pipe emissions. However, reaching the level of the World Health Organization (WHO) guidelines may instead depend upon the air quality co-benefits of ambitious climate action. Here, we assess pathways of Chinese PM 2.5 air quality from 2015 to 2060 under a combination of scenarios that link global and Chinese climate mitigation pathways (i.e. global 2°C- and 1.5°C-pathways, National Determined Contributions (NDC) pledges and carbon neutrality goals) to local clean air policies. We find that China can achieve both its near-term climate goals (peak emissions) and PM 2.5 air quality annual standard (35 μg/m3) by 2030 by fulfilling its NDC pledges and continuing air pollution control policies. However, the benefits of end-of-pipe control reductions are mostly exhausted by 2030, and reducing PM 2.5 exposure of the majority of the Chinese population to below 10 μg/m 3 by 2060 will likely require more ambitious climate mitigation efforts such as China's carbon neutrality goals and global 1.5°C-pathways. Our results thus highlight that China's carbon neutrality goals will play a critical role in reducing air pollution exposure to the level of the WHO guidelines and protecting public health.

54 ENVIRONMENTAL SCIENCES↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

&#8203↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions (Calendar Year 2018)

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and the North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons.The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. After 1962, testing was limited to underground detonations, which greatly reduced radiation exposure to the public. Since the end of nuclear testing in 1992, radiation monitoring has focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61Subpart H) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/y) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as Japan’s Fukushima nuclear power plant, which was damaged in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by reporting environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS (U.S. Environmental Protection Agency [EPA] and DOE 1995). This method was approved by the EPA in 2001 and has been the method used to demonstrate compliance with the 40 CFR 61.92 dose standard since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations because no member of the public resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Level (CL) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2018, the potential dose from radiological emissions to air from both current and past NNSS activities was well below the 10 mrem/y dose limit. This is demonstrated by air sampling data collected at the critical receptor air monitoring stations which had average concentrations of radioactivity that were a fraction of the CL values. Concentrations ranged from 0.1% to a maximum of 5.2% of the allowed NESHAP limit. Clean Air Package 1988 (CAP88-PC) was used to model dose to the offsite public from all 2018 NNSS radionuclide emissions. The model showed the maximally exposed individual to be on the northern end of Amargosa Valley; this individual received a potential dose of 0.07 mrem/y. The potential dose to the public from NLVF emissions was also very low at 0.000008 mrem/y, over six orders of magnitude lower than the 10 mrem/y limit.

54 ENVIRONMENTAL SCIENCES↗

Building America Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York (Fact Sheet)

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Solutions Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.

air leakage↗

Influence of the down-draft secondary air on the furnace aerodynamic characteristics of a down-fired boiler

The operation of down-fired boilers can suffer from problems of high carbon content in the fly ash. This is because horizontally fed secondary air keeps the fuel-rich flow from going deep down into the lower furnace and the recirculation zones in the furnace hopper area are too large. To improve the burnout of coal in down-fired boilers, a retrofit modification was devised and validated. The modification lowered the angle of flow of the secondary air to a down-draft. Experiments were carried out on a single-phase test facility to investigate the influence of down-draft secondary air on the aerodynamic field in the furnace. The depth reached by the fuel-rich flow in the down-furnace, the volume of dead recirculation zone, the angle of the mixed air in the airflow zone of secondary air, and the turbulence intensity in certain cross sections were investigated. The results show when the flow of secondary air was lowered to an optimized angle, the primary air can reach a deeper position in the lower furnace without washing the furnace hopper, and consequently the dead recirculation zone shrinks. The influence of the secondary air ratio distribution on the flow field was also investigated. 6 refs., 13 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Residential Forced Air System Cabinet Leakage and Blower Performance

This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit ? indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called"ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823"Performance Standard for air handlers in residential space conditioning systems".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probe into Gaseous Pollution and Assessment of Air Quality Benefit under Sector Dependent Emission Control Strategies over Megacities in Yangtze River Delta, China

On February 29th 2012, China published its new National Ambient Air Quality Standard (CH-NAAQS) aiming at revising the standards and measurements for both gaseous pollutants including ozone (O3), nitrogen dioxide (NO2), and sulfur dioxide (SO2), and also particle pollutants including PM10 and PM2.5. In order to understand the air pollution status regarding this new standard, the integrated MM5/CMAQ modeling system was applied over Yangtze River Delta (YRD) within this study to examine the criteria gaseous pollutants listed in the new CH-NAAQS. Sensitivity simulations were also conducted to assess the responses of gaseous pollutants under 8 different sector-dependent emission reduction scenarios in order to evaluate the potential control strategies. 2006 was selected as the simulation year in order to review the air quality condition at the beginning of China’s 11th Five-Year-Plan (FYP, from 2006 to 2010), and also compared with air quality status in 2010 as the end of 11th FYP to probe into the effectiveness of the national emission control efforts. Base case simulation showed distinct seasonal variation for gaseous pollutants: SO2, and NO2 were found to have higher surface concentrations in winter while O3 was found to have higher concentrations in spring and summer than other seasons. According to the analyses focused on 3 megacities within YRD, Shanghai, Nanjing, and Hangzhou, we found different air quality conditions among the cities: NO2 was the primary pollutant that having the largest number of days exceeding the CH-NAAQS daily standard (80 μg/m3) in Shanghai (59 days) and Nanjing (27 days); SO2 was the primary pollutant with maximum number of days exceeding daily air quality standard (150 μg/m3) in Hangzhou (28 days), while O3 exceeding the daily maximum 8-hour standard (160 μg/m3) for relatively fewer days in all the three cities (9 days in Shanghai, 14 days in Nanjing, and 11 days in Hangzhou). Simulation results from predefined potential applicable emission control scenarios suggested significant air quality improvements from emission reduction: 90% of SO2 emission removed from power plant in YRD would be able to reduce more than 85% of SO2 pollution, 85% NOx emission reduction from power plant would reduce more than 60% of NO2 pollution, in terms of reducing the number of days exceeding daily air quality standard. NOx emission reduction from transportation and industry were also found to effectively reduce NO2 pollution but less efficient than emission control from power plants. We also found that multi-pollutants emission control including both NOx and VOC would be a better strategy than independent NOx control over YRD which is China’s 12th Five-Year-Plan (from 2011 to 2015), because O3 pollution would be increased as a side effect of NOx control and counteract NO2 pollution reduction benefit.

Chinese National Air Quality Standard↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air pollution and emergency department visits for respiratory diseases: A multi-city case crossover study

Highlights: • Extensive research exists on the effects of ambient air pollution on respiratory diseases. • Emergency department visits for respiratory diseases increase after days with higher concentrations of air pollution. • Ambient pollution, even at low concentrations, appear to adversely affect the respiratory system. Increasing evidence suggests that ambient air pollution is a major risk factor for both acute and chronic respiratory disease exacerbations and emergencies. The objective of this study was to determine the association between ambient air pollutants and emergency department (ED) visits for respiratory conditions in nine districts across the province of Ontario in Canada. Health, air pollutant (PM{sub 2.5}, NO{sub 2}, O{sub 3}, and SO{sub 2}), and meteorological data were retrieved from April 2004 to December 2011. Respiratory diseases were categorized as: chronic obstructive pulmonary disease (COPD, including bronchiectasis) and acute upper respiratory diseases. A case-crossover design was used to test the associations between ED visits and ambient air pollutants, stratified by sex and season. For COPD among males, positive results were observed for NO{sub 2} with lags of 3–6 days, for PM{sub 2.5} with lags 1–8, and for SO{sub 2} with lags of 4–8 days. For COPD among females, positive results were observed for O{sub 3} with lags 2–4 days, and for SO{sub 2} among lags of 3–6 days. For upper respiratory disease emergencies among males, positive results were observed for NO{sub 2} (lags 5–8 days), for O{sub 3}, (lags 0–6 days), PM{sub 2.5} (all lags), and SO{sub 2} (lag 8), and among females, positive results were observed for NO{sub 2} for lag 8 days, for O{sub 3}, PM{sub 2.5} among all lags. Our study provides evidence of the associations between short-term exposure to air pollution and increased risk of ED visits for upper and lower respiratory diseases in an environment where air pollutant concentrations are relatively low.

54 ENVIRONMENTAL SCIENCES↗

Ambient air pollution and semen quality

Highlights: • Sperm development is sensitive to oxidative stress, a key effect of air pollution. • Prior evidence is inconclusive for an effect of air pollution on semen quality. • Ambient air pollution was not associated with most semen quality parameters. • Fine particulate matter was associated with smaller sperm head measures. • Findings are generally reassuring for healthy men exposed to moderate air pollution. Ambient air pollution is associated with systemic increases in oxidative stress, to which sperm are particularly sensitive. Although decrements in semen quality represent a key mechanism for impaired fecundability, prior research has not established a clear association between air pollution and semen quality. To address this, we evaluated the association between ambient air pollution and semen quality among men with moderate air pollution exposure.

54 ENVIRONMENTAL SCIENCES↗

Cardiovascular benefits of short-term indoor air filtration intervention in elderly living in Beijing: An extended analysis of BIAPSY study

Highlights: • Short-term air filtration can significantly reduce indoor air pollution concentrations. • Indoor air pollution exposure is positively associated with adverse cardiovascular effect. • Short-term indoor air filtration can be of some cardiovascular benefits in elderly. • Nonlinear inverse exposure-response relationships also confirmed benefits of air pollution reduction from filtration. Adverse cardiovascular effects associated with air pollution exposure have been widely demonstrated. However, inconsistent cardiovascular responses were observed from reducing indoor air pollution exposure. We aimed to assess whether short-term air filtration intervention could benefit cardiovascular health in elderly living in high pollution area.

54 ENVIRONMENTAL SCIENCES↗

Roles of Mn and Co in the Air Synthesizability of Layered Oxide Cathodes for Lithium-Based Batteries

High-nickel layered oxides (LiNi 1-x-y Mn x Co y O 2 ) are the prevailing cathode materials for high-energy-density lithium-based batteries, but they are plagued with deleterious surface air instabilities stemming from residual lithium formation. These issues severely hinder mass production as cathode calcination is limited to a flowing oxygen atmosphere, which entails high manufacturing costs as opposed to simpler and more economical air calcination. Here, while higher Ni contents are known to worsen air instabilities, the influence of Mn and Co contents on impacting these phenomena are less elucidated. We herein present the synthesis in ambient air and flowing oxygen atmospheres of three cathode variants with the same Ni contents, but varying Mn and Co contents: LiNi 0.7 Mn 0.3 O 2 , LiNi 0.7 Mn 0.15 Co 0.15 O 2 , and LiNi 0.7 Co 0.3 O 2 . It is found that the critical parameter influencing the air stability of the cathodes is the average Ni oxidation state, which is greatly dependent on the Mn and Co contents. Substitution of Mn for Ni drives down the Ni oxidation state as Mn exists as Mn4 + and reduces surface residual lithium formation, which vastly improves the overall air stability and, therefore, the synthesizability in air, but with a penalty of lowered capacity. In contrast, substitution of Co for Ni maintains Ni 3+ as Co exists as Co 3+ , offering increased initial capacity, but worsens the air stability and cyclability as the driving force for residual lithium formation and surface reactivity is increased.

25 ENERGY STORAGE↗

An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors

Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. Furthermore, the Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached to the watch’s minute hand, and as it rotates, more of the underlying source is revealed. The alpha activity we measured increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. We also used data obtained using the Dynamic Radioactive Source to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.

07 ISOTOPE AND RADIATION SOURCES↗