Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration: Preprint

Dynamic, scalable and interoperable control paradigm is required to enable efficient, secure, reliable and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research work on developing a novel, holistic, data enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control together with distributed grid edge control, and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Demonstration of Essential Reliability Services by a 300-MW Solar Photovoltaic Power Plant

The California Independent System Operator (CAISO), First Solar, and the National Renewable Energy Laboratory (NREL) conducted a demonstration project on a large utility-scale photovoltaic (PV) power plant in California to test its ability to provide essential ancillary services to the electric grid. With increasing shares of solar- and wind-generated energy on the electric grid, traditional generation resources equipped with automatic governor control (AGC) and automatic voltage regulation controls -- specifically, fossil thermal -- are being displaced. The deployment of utility-scale, grid-friendly PV power plants that incorporate advanced capabilities to support grid stability and reliability is essential for the large-scale integration of PV generation into the electric power grid, among other technical requirements. A typical PV power plant consists of multiple power electronic inverters and can contribute to grid stability and reliability through sophisticated 'grid-friendly' controls. In this way, PV power plants can be used to mitigate the impact of variability on the grid, a role typically reserved for conventional generators. In August 2016, testing was completed on First Solar's 300-MW PV power plant, and a large amount of test data was produced and analyzed that demonstrates the ability of PV power plants to use grid-friendly controls to provide essential reliability services. These data showed how the development of advanced power controls can enable PV to become a provider of a wide range of grid services, including spinning reserves, load following, voltage support, ramping, frequency response, variability smoothing, and frequency regulation to power quality. Specifically, the tests conducted included various forms of active power control such as AGC and frequency regulation; droop response; and reactive power, voltage, and power factor controls. This project demonstrated that advanced power electronics and solar generation can be controlled to contribute to system-wide reliability. It was shown that the First Solar plant can provide essential reliability services related to different forms of active and reactive power controls, including plant participation in AGC, primary frequency control, ramp rate control, and voltage regulation. For AGC participation in particular, by comparing the PV plant testing results to the typical performance of individual conventional technologies, we showed that regulation accuracy by the PV plant is 24-30 points better than fast gas turbine technologies. The plant's ability to provide volt-ampere reactive control during periods of extremely low power generation was demonstrated as well. The project team developed a pioneering demonstration concept and test plan to show how various types of active and reactive power controls can leverage PV generation's value from being a simple variable energy resource to a resource that provides a wide range of ancillary services. With this project's approach to a holistic demonstration on an actual, large, utility-scale, operational PV power plant and dissemination of the obtained results, the team sought to close some gaps in perspectives that exist among various stakeholders in California and nationwide by providing real test data.

14 SOLAR ENERGY↗

Wide-voltage-window reversible control of electronic transport in electrolyte-gated epitaxial BaSnO 3

The wide gap perovskite semiconductor BaSnO 3 has attracted much interest since the discovery of room temperature electron mobility up to 320 cm 2 V -1 s -1 in bulk crystals. Motivated by applications in oxide heterostructures, rapid progress has been made with BaSnO 3 films, although questions remain regarding transport mechanisms and mobility optimization. Here we report on a detailed study of epitaxial BaSnO 3 electric double layer transistors based on ion gel electrolytes, enabling wide-doping-range studies of transport in single films. The work spans an order of magnitude in initial n doping (similar to 10 19 to 10 20 cm -3 , with both oxygen vacancies and La), film thicknesses from 10-50 nm, and measurements of resistance, Hall effect, mobility, and magnetoresistance. In contrast with many oxides, electrolyte gating of BaSnO 3 is found to be essentially reversible over an exceptional gate voltage window (approaching +/- 4 V), even at 300 K, supported by negligible structural modification in operando synchrotron x-ray diffraction. We propose that this occurs due to a special situation in BaSnO3, where electrochemical gating via oxygen vacancies is severely limited by their low diffusivity. Wide-range reversible modulation of transport is thus achieved (in both electron accumulation and depletion modes), spanning strongly localized, weakly localized, and metallic regimes. Two-channel conduction analysis is then combined with self-consistent Schrodinger-Poisson and Thomas-Fermi modeling to extract accumulation layer electron densities and mobilities. Electrostatic electron densities approaching 10 14 cm -2 are shown to increase room temperature mobility by up to a factor of similar to 24. These results lay the groundwork for future studies of electron-density-dependent phenomena in high mobility BaSnO 3 , and significantly elucidate oxide electrolyte gating mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

Tethered system/space platform integration - TSS lessons learned

Tethered spacecraft systems must be integrated with their user platforms in a way that allows both to carry out their design functions efficiently and safely. This paper describes the lessons learned about tethered system integration with a space platform from the NASA/PSN Tethered Satellite System. Items discussed include platform attitude control, induced voltage and current control, satellite tracking and tether length measurement, satellite communications and system operations sensitivities. A number of engineering issues yet to be resolved are noted. Tethered systems are complex and require careful design to ensure successful operation.

Rudolph, L. K.↗

CALIPSO Mission Status Update: Payload Status

The CALIPSO mission payload status update is presented. The contents include: 1) Wide Field Camera Overview; 2) WFC Temperatures; 3) WFC Voltages; 4) Imaging Infrared Radiometer (IIR) Health; 5) IIR Voltages; 6) Payload Control (PLC) Voltages; 7) PLC Temperatures; 8) Low Voltage Power Supply (LVPS) (CALOPS0025N); 9) PLC Radiation Effects; 10) SDS Status (CALOPS0020N); 11) CALIOP LIDAR; 12) Laser Energy Trends; 13) Laser Energy Zoom; 14) Laser Management Approach; 15) Green / Red Ratio; 16) Pedestal @ SHG Temperature Trends; 17) LOM Heater Duty Cycle Trends; 18) LOM Pressure Trends; 19) Boresight Trend; 20) 1064 Dark Noise Trend; 21) 532 SNR Trend; 22) Spike Trends; 23) LIDAR Highlights; 24) Backup Laser Status; and 25) Future Plans.

Verhappen, Ron↗

Multifunctional Logic Gate Controlled by Supply Voltage

A complementary metal oxide/semiconductor (CMOS) electronic circuit functions as a NAND gate at a power-supply potential (V(sub dd)) of 3.3 V and as NOR gate for V(sub dd) = 1.8 V. In the intermediate V(sub dd) range of 1.8 to 3.3 V, this circuit performs a function intermediate between NAND and NOR with degraded noise margin. Like the circuit of the immediately preceding article, this circuit serves as a demonstration of the evolutionary approach to design of polymorphic electronics -- a technological discipline that emphasizes evolution of the design of a circuit to perform different analog and/or digital functions under different conditions. In this instance, the different conditions are different values of V(sub dd).

Stoica, Adrian↗