Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time factors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Contrast affects flicker and speed perception differently

We have previously shown that contrast affects speed perception, with lower-contrast, drifting gratings perceived as moving slower. In a recent study, we examined the implications of this result on models of speed perception that use the amplitude of the response of linear spatio-temporal filters to determine speed. In this study, we investigate whether the contrast dependence of speed can be understood within the context of models in which speed estimation is made using the temporal frequency of the response of linear spatio-temporal filters. We measured the effect of contrast on flicker perception and found that contrast manipulations produce opposite effects on perceived drift rate and perceived flicker rate, i.e., reducing contrast increases the apparent temporal frequency of counterphase modulated gratings. This finding argues that, if a temporal frequency-based algorithm underlies speed perception, either flicker and speed perception must not be based on the output of the same mechanism or contrast effects on perceived spatial frequency reconcile the disparate effects observed for perceived temporal frequency and speed.

NASA Center ARC↗

A review of adaptive change in musculoskeletal impedance during space flight and associated implications for postflight head movement control

We present a review of converging sources of evidence which suggest that the differences between loading histories experienced in 1-g and weightlessness are sufficient to stimulate adaptation in mechanical impedance of the musculoskeletal system. As a consequence of this adaptive change we argue that we should observe changes in the ability to attenuate force transmission through the musculoskeletal system both during and after space flight. By focusing attention on the relation between human sensorimotor activity and support surfaces, the importance of controlling mechanical energy flow through the musculoskeletal system is demonstrated. The implications of such control are discussed in light of visual-vestibular function in the specific context of head and gaze control during postflight locomotion. Evidence from locomotory biomechanics, visual-vestibular function, ergonomic evaluations of human vibration, and specific investigations of locomotion and head and gaze control after space flight, is considered.

Review, Tutorial↗

Modeling the effects of exercise during 100% oxygen prebreathe on the risk of hypobaric decompression sickness

BACKGROUND: Several previous studies indicated that exercise during prebreathe with 100% O2 decreased the incidence of hypobaric decompression sickness (DCS). We report a meta-analysis of these investigations combined with a new study in our laboratory to develop a statistical model as a predictive tool for DCS. HYPOTHESIS: Exercise during prebreathe increases N2 elimination in a theoretical 360-min half-time compartment decreasing the incidence of DCS. METHODS: A dose-response probability tissue ratio (TR) model with 95% confidence limits was created for two groups, prebreathe with exercise (n = 113) and resting prebreathe (n = 113), using nonlinear regression analysis with maximum likelihood optimization. RESULTS: The model predicted that prebreathe exercise would reduce the residual N2 in a 360-min half-time compartment to a level analogous to that in a 180-min compartment. This finding supported the hypothesis. The incidence of DCS for the exercise prebreathe group was significantly decreased (Chi-Square = 17.1, p < 0.0001) from the resting prebreathe group. CONCLUSIONS: The results suggested that exercise during prebreathe increases tissue perfusion and N2 elimination approximately 2-fold and markedly lowers the risk of DCS. Based on the model, the prebreathe duration may be reduced from 240 min to a predicted 91 min for the protocol in our study, but this remains to be verified. The model provides a useful planning tool to develop and test appropriate prebreathe exercise protocols and to predict DCS risks for astronauts.

NASA Program Environmental Health↗

Human life support for advanced space exploration

The requirements for a human life support system for long-duration space missions are reviewed. The system design of a controlled ecological life support system is briefly described, followed by a more detailed account of the study of the conceptual design of a Lunar Based CELSS. The latter is to provide a safe, reliable, recycling lunar base life support system based on a hybrid physicochemical/biological representative technology. The most important conclusion reached by this study is that implementation of a completely recycling CELSS approach for a lunar base is not only feasible, but eminently practical. On a cumulative launch mass basis, a 4-person Lunar Base CELSS would pay for itself in approximately 2.6 years relative to a physicochemical air/water recycling system with resupply of food from the Earth. For crew sizes of 30 and 100, the breakeven point would come even sooner, after 2.1 and 1.7 years, respectively, due to the increased mass savings that can be realized with the larger plant growth units. Two other conclusions are particularly important with regard to the orientation of future research and technology development. First, the mass estimates of the Lunar Base CELSS indicate that a primary design objective in implementing this kind of system must be to minimized the mass and power requirement of the food production plant growth units, which greatly surpass those of the other air and water recycling systems. Consequently, substantial research must be directed at identifying ways to produce food more efficiently. On the other hand, detailed studies to identify the best technology options for the other subsystems should not be expected to produce dramatic reductions in either mass or power requirement of a Lunar Base CELSS. The most crucial evaluation criterion must, therefore, be the capability for functional integration of these technologies into the ultimate design of the system. Secondly, this study illustrates that existing or near-term technologies are adequate to implement a Lunar Base CELSS. There are no apparent "show-stoppers" which require the development of new technologies. However, there are several areas in which new materials and technologies could be used for a more efficient implementation of the system, e.g., by decreasing mass or power requirement and increasing recycling efficiency. These areas must be further addressed through research and development. Finally, although this study focused on the development of a Lunar Base CELSS, the same technologies and a nearly identical design would be appropriate for a Mars base. Actually, except for the distance of transportation, the implementation of a CELSS on Mars would even be easier than it would be on the Moon. The presence of atmospheric CO2 on Mars, although in low concentration, coupled with the fact that the day/night cycle on Mars is very similar to that on Earth, makes the use of light-weight, greenhouse-like structures for growing food plants even more feasible than on the Moon. There are some environmental problems, which would have to be dealt with, like dust storms and the large amount of the ultraviolet radiation incident on the planet's surface. However, the materials and methods are largely available today to develop such a life support system for a Mars base.

Review, Tutorial↗

Changes in the immune system during and after spaceflight

The results of immunological analyses before, during and after spaceflight, have established the fact that spaceflight can result in a blunting of the immune mechanisms of human crew members and animal test species. There is some evidence that the immune function changes in short-term flights resemble those occurring after acute stress, while the changes during long-term flights resemble those caused by chronic stress. In addition, this blunting of the immune function occurs concomitant with a relative increase in potentially infectious microorganisms in the space cabin environment. This combination of events results in an increased probability of inflight infectious events. The realization of this probability has been shown to be partially negated by the judicious use of a preflight health stabilization program and other operational countermeasures. The continuation of these countermeasures, as well as microbial and immunological monitoring, are recommended for continued spaceflight safety.

manned↗

Contractile properties of rat, rhesus monkey, and human type I muscle fibers

It is well known that skeletal muscle intrinsic maximal shortening velocity is inversely related to species body mass. However, there is uncertainty regarding the relationship between the contractile properties of muscle fibers obtained from commonly studied laboratory animals and those obtained from humans. In this study we determined the contractile properties of single chemically skinned fibers prepared from rat, rhesus monkey, and human soleus and gastrocnemius muscle samples under identical experimental conditions. All fibers used for analysis expressed type I myosin heavy chain as determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Allometric coefficients for type I fibers from each muscle indicated that there was little change in peak tension (force/fiber cross-sectional area) across species. In contrast, both soleus and gastrocnemius type I fiber maximal unloaded shortening velocity (Vo), the y-intercept of the force-velocity relationship (Vmax), peak power per unit fiber length, and peak power normalized for fiber length and cross-sectional area were all inversely related to species body mass. The present allometric coefficients for soleus fiber Vo (-0.18) and Vmax (-0.11) are in good agreement with published values for soleus fibers obtained from common laboratory and domesticated mammals. Taken together, these observations suggest that the Vo of slow fibers from quadrupeds and humans scale similarly and can be described by the same quantitative relationships. These findings have implications in the design and interpretation of experiments, especially those that use small laboratory mammals as a model of human muscle function.

NASA Discipline Musculoskeletal↗

Height increase, neuromuscular function, and back pain during 6 degrees head-down tilt with traction

BACKGROUND: Spinal lengthening and back pain are commonly experienced by astronauts exposed to microgravity. METHODS: To develop a ground-based simulation for spinal adaptation to microgravity, we investigated height increase, neuromuscular function and back pain in 6 subjects all of whom underwent two forms of bed rest for 3 d. One form consisted of 6 degrees of head-down tilt (HDT) with balanced traction, while the other was horizontal bed rest (HBR). Subjects had a 2-week recovery period in between the studies. RESULTS: Total body and spinal length increased significantly more and the subjects had significantly more back pain during HDT with balanced traction compared to HBR. The distance between the lower endplate of L4 and upper endplate of S1, as measured by ultrasonography, increased significantly in both treatments to the same degree. Intramuscular pressures in the erector spinae muscles and ankle torque measurements during plantarflexion and dorsiflexion did not change significantly during either treatment. CONCLUSION: Compared to HBR, HDT with balanced traction may be a better method to simulate changes of total body and spinal lengths, as well as back pain seen in microgravity.

NASA Discipline Number 26-10↗

A model for the kinetics of homotypic cellular aggregation under static conditions

We present the formulation and testing of a mathematical model for the kinetics of homotypic cellular aggregation. The model considers cellular aggregation under no-flow conditions as a two-step process. Individual cells and cell aggregates 1) move on the tissue culture surface and 2) collide with other cells (or aggregates). These collisions lead to the formation of intercellular bonds. The aggregation kinetics are described by a system of coupled, nonlinear ordinary differential equations, and the collision frequency kernel is derived by extending Smoluchowski's colloidal flocculation theory to cell migration and aggregation on a two-dimensional surface. Our results indicate that aggregation rates strongly depend upon the motility of cells and cell aggregates, the frequency of cell-cell collisions, and the strength of intercellular bonds. Model predictions agree well with data from homotypic lymphocyte aggregation experiments using Jurkat cells activated by 33B6, an antibody to the beta 1 integrin. Since cell migration speeds and all the other model parameters can be independently measured, the aggregation model provides a quantitative methodology by which we can accurately evaluate the adhesivity and aggregation behavior of cells.

Non-NASA Center↗

Postural tachycardia syndrome: time frequency mapping

Orthostatic tachycardia is common but its specificity remains uncertain. Our preliminary work suggested that using autonomic function testing in conjunction with time-frequency mapping (TFM), it might be possible to characterize a subset of the postural tachycardia syndrome (POTS), that is due to a restricted autonomic neuropathy. We describe 20 patients (17 women and 3 men, aged 14-43 years) with florid POTS and 20 controls (14 women and 6 men, aged 20-41 years). Autonomic failure was quantified by its distribution (cardiovagal, adrenergic and sudomotor) and severity, a symptom profile was generated, and spectral indices, based on modified Wigner distribution during rest and head-up tilt (80 degrees) were evaluated. During tilt-up POTS patients differed from controls by an excessive heart rate (> 130 bpm) (P < 0.001), and higher diastolic pressure (P < 0.01). During rest, cardiovagal oscillations (at respiratory frequencies [RF]) and slow rhythms at nonrespiratory frequencies (NONRF) (from 0.01 to 0.07 Hz) in R-R intervals (RRI) (P < 0.01) were reduced. Both RF and NONRF rhythms in RRI were further blunted with tilt-up (P < 0.001). Slow adrenergic vasomotor rhythms in blood pressure (BP) (approximately 0.07 Hz) surged with tilt-up and returned to normal levels afterwards. The index of sympatho-vagal balance (NONRF-Systolic BP (SBP)/RF-RRI) was dramatically increased in POTS (P < 0.001). Distal postganglionic sudomotor failure was observed, and impairment of the BP responses to the Valsalva maneuver (phase II) suggested peripheral adrenergic dysfunction. Persistent orthostatic dizziness, tiredness, gastrointestinal symptoms and palpitations were common in POTS patients. It is possible to identify a subset of POTS patients who have a length-dependent autonomic neuropathy, affecting the peripheral adrenergic and cardiovagal fibers, with relative preservation of cardiac adrenergic fibers.

NASA Discipline Number 14-10↗

Behavioral analysis of signals that guide learned changes in the amplitude and dynamics of the vestibulo-ocular reflex

We characterized the dependence of motor learning in the monkey vestibulo-ocular reflex (VOR) on the duration, frequency, and relative timing of the visual and vestibular stimuli used to induce learning. The amplitude of the VOR was decreased or increased through training with paired head and visual stimulus motion in the same or opposite directions, respectively. For training stimuli that consisted of simultaneous pulses of head and target velocity 80-1000 msec in duration, brief stimuli caused small changes in the amplitude of the VOR, whereas long stimuli caused larger changes in amplitude as well as changes in the dynamics of the reflex. When the relative timing of the visual and vestibular stimuli was varied, brief image motion paired with the beginning of a longer vestibular stimulus caused changes in the amplitude of the reflex alone, but the same image motion paired with a later time in the vestibular stimulus caused changes in the dynamics as well as the amplitude of the VOR. For training stimuli that consisted of sinusoidal head and visual stimulus motion, low-frequency training stimuli induced frequency-selective changes in the VOR, as reported previously, whereas high-frequency training stimuli induced changes in the amplitude of the VOR that were more similar across test frequency. The results suggest that there are at least two distinguishable components of motor learning in the VOR. One component is induced by short-duration or high-frequency stimuli and involves changes in only the amplitude of the reflex. A second component is induced by long-duration or low-frequency stimuli and involves changes in the amplitude and dynamics of the VOR.

NASA Discipline Neuroscience↗

Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model

The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.

Non-NASA Center↗

Lower limb kinematics during treadmill walking after space flight: implications for gaze stabilization

We examined the lower limb joint kinematics observed during pre- and postflight treadmill walking performed by seven subjects from three Space Shuttle flights flown between March 1992 and February 1994. Basic temporal characteristics of the gait patterns, such as stride time and duty cycle, showed no significant changes after flight. Evaluation of phaseplane variability across the gait cycle suggests that postflight treadmill walking is more variable than preflight, but the response throughout the course of a cycle is joint dependent and, furthermore, the changes are subject dependent. However, analysis of the phaseplane variability at the specific locomotor events of heel strike and toe off indicated statistically significant postflight increases in knee variability at the moment of heel strike and significantly higher postflight hip joint variability at the moment of toe off. Nevertheless, the observation of component-specific variability was not sufficient to cause a change in the overall lower limb joint system stability, since there was no significant change in an index used to evaluate this at both toe off and heel strike. The implications of the observed lower limb kinematics for head and gaze control during locomotion are discussed in light of a hypothesized change in the energy attenuation capacity of the musculoskeletal system in adapting to weightlessness.

NASA Discipline Number 16-10↗

[Heart functions in monkeys during a 2-week antiorthostatic hypokinesia]

Dynamics of the left heart ventricular muscle contractility and compliance was studied in 4 monkeys in the head down position (antiorthostatic hypokinesia) with the body angle 10 during 2 weeks. Functional tests on a tilt table and under two conditions of centrifuge rotation were performed prior to and after the antiorthostatic hypokinesia. No changes in the left heart ventricular muscle contractility was found. However, the sensitivity level of the baroreflex control decreased. Compliance of the left heart myocardial fibre increased in the first hours and days of the antiorthostatic hypokinesia.

NASA Discipline Regulatory Physiology↗

Hyaluronic acid is increased in the skin and urine in patients with amyotrophic lateral sclerosis

We performed morphological studies of skin and measured glycosaminoglycans in the urine from patients with sporadic amyotrophic lateral sclerosis (ALS) and control subjects. The wide spaces separating collagen bundles reacted strongly with alcian blue stain in ALS patients and stained more markedly as ALS progressed. Staining with alcian blue was virtually eliminated by Streptomyces hyaluronidase. The urinary excretion of hyaluronic acid (HA) (mg/day) was significantly increased (P < 0.01) in ALS patients compared with that of control subjects, and there was a significant positive correlation between the excreted amount of HA and the duration of illness in advanced ALS patients with a duration of more than 2 years from clinical onset (r = 0.72, P < 0.02). We suggest that sporadic ALS includes a metabolic disorder of HA in which an accumulation of HA in the skin is linked to an increased urinary excretion of HA.

NASA Discipline Musculoskeletal↗

The barberplaid illusion: plaid motion is biased by elongated apertures

The perceived direction of motion of plaids windowed by elongated spatial Gaussians is biased toward the window's long axis. The bias increases as the relative angle between the plaid motion and the long axis of the window increases, peaks at a relative angle of approximately 45 deg, and then decreases. The bias increases as the window is made narrower (at fixed height) and decreases as the component spatial frequency increases (at fixed aperture size). We examine several models of human motion processing (cross-correlation, motion-energy, intersection-of-constraints, and vector-sum), and show that none of these standard models can predict our data. We conclude that spatial integration of motion signals plays a crucial role in plaid motion perception and that current models must be explicitly expanded to include such spatial interactions.

NASA Center ARC↗

Yeast respond to hypotonic shock with a calcium pulse

We have used the transgenic AEQUORIN calcium reporter system to monitor the cytosolic calcium ([Ca2+]cyt) response of Saccharomyces cerevisiae to hypotonic shock. Such a shock generates an almost immediate and transient rise in [Ca2+]cyt which is eliminated by gadolinium, a blocker of stretch-activated channels. In addition, this transient rise in [Ca2+]cyt is initially insensitive to 1,2-bis-(o-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid (BAPTA), an extracellular calcium chelator. However, BAPTA abruptly attenuates the maintenance of that transient rise. These data show that hypotonic shock generates a stretch-activated channel-dependent calcium pulse in yeast. They also suggest that the immediate calcium influx is primarily generated from intracellular stores, and that a sustained increase in [Ca2+]cyt depends upon extracellular calcium.

NASA Discipline Plant Biology↗

Interkinetic and migratory behavior of a cohort of neocortical neurons arising in the early embryonic murine cerebral wall

Neocortical neuronogenesis occurs in the pseudostratified ventricular epithelium (PVE) where nuclei of proliferative cells undergo interkinetic nuclear movement. A fraction of daughter cells exits the cell cycle as neurons (the quiescent, or Q, fraction), whereas a complementary fraction remains in the cell cycle (the proliferative, or P, fraction). By means of sequential thymidine and bromodeoxyuridine injections in mouse on embryonic day 14, we have monitored the proliferative and post-mitotic migratory behaviors of 1 and 2 hr cohorts of PVE cells defined by the injection protocols. Soon after mitosis, the Q fraction partitions into a rapidly exiting (up to 50 microns/hr) subpopulation (Qr) and a more slowly exiting (6 microns/hr) subpopulation (Qs). Qr and Qs are separated as two distributions on exit from the ventricular zone with an interpeak distance of approximately 40 microns. Cells in Qr and Qs migrate through the intermediate zone with no significant change in the interpeak distance, suggesting that they migrate at approximately the same velocities. The rate of migration increases with ascent through the intermediate zone (average 2-6.4 microns/hr) slowing only transiently on entry into the developing cortex. Within the cortex, Qr and Qs merge to form a single distribution most concentrated over layer V.

NASA Discipline Neuroscience↗

Relationship of the time course of venous gas bubbles to altitude decompression illness

The correlation is low between the occurrence of gas bubbles in the pulmonary artery, called venous gas emboli (VGE), and subsequent decompression illness (DCI). The correlation improves when a "grade" of VGE is considered; a zero to four categorical classification based on the intensity and duration of the VGE signal from a Doppler bubble detector. Additional insight about DCI might come from an analysis of the time course of the occurrence of VGE. Using the NASA Hypobaric Decompression Sickness Databank, we compared the time course of the VGE outcome between 322 subjects who exercised and 133 Doppler technicians who did not exercise to evaluate the role of physical activity on the VGE outcome and incidence of DCI. We also compared 61 subjects with VGE and DCI with 110 subjects with VGE but without DCI to identify unique characteristics about the time course of the VGE outcome to try to discriminate between DCI and no-DCI cases. The VGE outcome as a function of time showed a characteristic short lag, rapid response, and gradual recovery phase that was related to physical activity at altitude and the presence or absence of DCI. The average time for DCI symptoms in a limb occurred just before the time of the highest fraction of VGE in the pulmonary artery. It is likely, but not certain, that an individual will report a DCI symptom if VGE are detected early in the altitude exposure, the intensity or grade of VGE rapidly increases from a limb region, and the intensity or grade of VGE remains high.

NASA Discipline Environmental Health↗