Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Microstructure Reconstruction of Sheet Molding Composite Using a Random Chips Packing Algorithm

Fiber-reinforced polymer composites are strong candidates for structural materials to replace steel and light alloys in lightweight vehicle design because of their low density and relatively high strength. In the integrated computational materials engineering (ICME) development of carbon fiber composites, microstructure reconstruction algorithms are needed to generate material microstructure representative volume element (RVE) based on the material processing information. The microstructure RVE reconstruction enables the material property prediction by finite element analysis (FEA)This paper presents an algorithm to reconstruct the microstructure of a chopped carbon fiber/epoxy laminate material system produced by compression molding, normally known as sheet molding compounds (SMC). The algorithm takes the result from material’s manufacturing process as inputs, such as the orientation tensor of fibers, the chopped fiber sheet geometry, and the fiber volume fraction. The chopped fiber sheets are treated as deformable rectangle chips and a random packing algorithm is developed to pack these chips into a square plate. The RVE is built in a layer-by-layer fashion until the desired number of lamina is reached, then a fine tuning process is applied to finalize the reconstruction. Compared to the previous methods, this new approach has the ability to model bended fibers by allowing limited amount of overlaps of rectangle chips. Furthermore, the method does not need SMC microstructure images, for which the image-based characterization techniques have not been mature enough, as inputs. Case studies are performed and the results show that the statistics of the reconstructed microstructures generated by the algorithm matches well with the target input parameters from processing.

Huang, Tianyu↗

A Virtual Reality Visualization Tool for Neuron Tracing

Tracing neurons in large-scale microscopy data is crucial to establishing a wiring diagram of the brain, which is needed to understand how neural circuits in the brain process information and generate behavior. Automatic techniques often fail for large and complex datasets, and connectomics researchers may spend weeks or months manually tracing neurons using 2D image stacks. We present a design study of a new virtual reality (VR) system, developed in collaboration with trained neuroanatomists, to trace neurons in microscope scans of the visual cortex of primates. We hypothesize that using consumer-grade VR technology to interact with neurons directly in 3D will help neuroscientists better resolve complex cases and enable them to trace neurons faster and with less physical and mental strain. We discuss both the design process and technical challenges in developing an interactive system to navigate and manipulate terabyte-sized image volumes in VR. Using a number of different datasets, we demonstrate that, compared to widely used commercial software, consumer-grade VR presents a promising alternative for scientists.

97 MATHEMATICS AND COMPUTING↗

Particle velocity measurement within a free-falling particle curtain using microscopic shadow velocimetry

We report an optical method for particle velocity measurement that is suitable for the measurement of particle velocities within dense particle-laden flows with high spatial resolution. The technique is based on particle shadow velocimetry with the use of a long-distance microscopic lens for images collection. The narrow depth of field of the lens allows particles within the focal plane to have much higher pattern intensities than those outside it on the collected images. Data processing was then employed to remove particles from outside the focal plane based on the gradient of the signal and a threshold. Following this, particle velocity was calculated from two successive images in the usual way. The technique was successfully demonstrated in a free-falling particle curtain with volume fractions in the four-way coupling regime of near-spherical micro-particles falling under gravity. The method was successfully employed to measure the transverse velocity profile through the curtain, which is the first time that such a measurement has been performed. Other highly-fidelity experimental data, which is also well suited to model development and validation, include the particle mass flow rate, curtain thickness and opacity.

Han, Shipu (ORCID:0000000278545882)↗

NanoXCT - A High-Resolution Technique For TSV Characterization

Lab-based Transmission X-ray Microscopy and X-ray Computed Tomography (TXM/XCT) with sub-100 nm resolution are evaluated for their application in process and quality control in microelectronics, particularly for TSV characterization. These are the techniques of choice to localize defects in copper TSVs for 3D IC integration. In contrast to other techniques like Focused Ion Beam cross-sectioning and subsequent Scanning Electron Microscopy imaging, the region of interest, i.e. the TSV, is imaged nondestructively and three dimensionally. For flat samples like thinned wafers, the tilted rotational axis tomography is proposed instead of the limited angle tomography since the better in-plane resolution increases the quality of the resulting tomogram. Yield- and reliability-limiting processes in 3D TSV technology like voids and incomplete filled vias can be made visible for an array of adjacent TSVs during one measurement without affecting the TSV.

36 MATERIALS SCIENCE↗

Image-based novel fault detection with deep learning classifiers using hierarchical labels

One important characteristic of modern fault classification systems is the ability to flag the system when faced with previously unseen fault types. This work considers the unknown fault detection capabilities of deep neural network-based fault classifiers. Specifically, we propose a methodology on how, when available, labels regarding the fault taxonomy can be used to increase unknown fault detection performance without sacrificing model performance. To achieve this, we propose to utilize soft label techniques to improve the state-of-the-art deep novel fault detection techniques during the training process and novel hierarchically consistent detection statistics for online novel fault detection. Lastly, we demonstrated increased detection performance on novel fault detection in inspection images from the hot steel rolling process, with results well replicated across multiple scenarios and baseline detection methods.

42 ENGINEERING↗

Atomic force microscopy phase imaging of epitaxial graphene films

Abstract Dynamic mode atomic force microscopy phase imaging is known to produce distinct contrast between graphene areas of different atomic thickness. But the intrinsic complexity of the processes controlling the tip motion and the phase angle shift excludes its use as an independent technique for a quantitative type of analysis. By investigating the relationship between the phase shift, the tip-surface interaction, and the thickness of the epitaxial graphene areas grown on silicon carbide, we shed light on the origin of such phase contrast, and on the complex energy dissipation processes underlying phase imaging. In particular, we study the behavior of phase shift and energy dissipation when imaging the interfacial buffer layer, single-layer, and bilayer graphene regions as a function of the tip-surface separation and the interaction forces. Finally, we compare these results with those obtained on differently-grown quasi free standing single- and bilayer graphene samples.

Lavini, Francesco (ORCID:0000000257223040)↗

Correlation of SWIR imaging with LPBF 304L stainless steel part properties

In the Laser Powder Bed Fusion (LPBF) process, the local thermal history can vary significantly over a part as the heat transfer characteristics and the laser scan path are geometry dependent. The variations introduce the potential for defects that lead to part failure, some of which are difficult to identify non-destructively with common ex-situ evaluation techniques. These defects include significant microstructural and mechanical property differences in the part interiors. In this paper, thermal features are extracted from in-situ Short-Wave Infrared (SWIR) imaging measurements to compile voxel based part representations and understand how the complexities in the thermal history affect part performance. The deviations in thermal features due to different laser processing parameters and complex scan pathing are explored. Empirical correlations are developed to map thermal features with the engineering properties (bulk yield strength, area percentage porosity, and local state) of 304L stainless steel parts manufactured by LPBF. Processing modes (insufficient melting and keyholing) are determined by mapping part property measurements with multiple thermal features. Generating the relationships between thermographic measurements and resulting SLM part properties lays the foundation for in-situ part qualification.

36 MATERIALS SCIENCE↗

Dynamic fracture processes in hydrogen embrittled iron

Mechanistic understanding of hydrogen embrittlement is critical to the transport and storage of hydrogen as a sustainable fuel. Experimental observation of dynamic fracture processes in hydrogen environments has been challenging. Here, in-situ transmission X-ray microscopy is used to image polycrystalline iron foils that are concurrently strained and electrochemically charged with hydrogen. Using this technique, voids and microcracks down to ∼30 nm in size are identified at or near the crack tip and tracked as strain is increased. We observe both hydrogen-induced transgranular failure and hydrogen-induced intergranular failure with distinct fracture processes. We find that transgranular fracture occurs through the formation of sharp branched structures at the main crack tip that are reminiscent of slip band formation. This is followed by void growth and coalescence, and interaction with secondary cracks that lead to propagation of the main crack. Intergranular fracture is found to occur through void coalescence along grain boundaries, along with significant secondary cracking near the crack tip. The crack growth rate is greater for void-mediated intergranular failure than for slip-mediated transgranular failure. Additionally, the removal of hydrogen results in recovered ductility for a crack initially propagated under hydrogen charging.

36 MATERIALS SCIENCE↗

A sub-sampled approach to extremely low-dose STEM

The inpainting of deliberately and randomly sub-sampled images offers a potential means to image specimens at a high resolution and under extremely low-dose conditions (≤1 e - /Å 2 ) using a scanning transmission electron microscope. We show that deliberate sub-sampling acquires images at least an order of magnitude faster than conventional low-dose methods for an equivalent electron dose. More importantly, when adaptive sub-sampling is implemented to acquire the images, there is a significant increase in the resolution and sensitivity which accompanies the increase in imaging speed. Lastly, we demonstrate the potential of this method for beam sensitive materials and in-situ observations by experimentally imaging the node distribution in a metal-organic framework.

47 OTHER INSTRUMENTATION↗

End-of-injection fuel dribble of multi-hole diesel injector: Comprehensive investigation of phenomenon and discussion on control strategy

The needle shutdown of fuel injectors leads to an undesired fuel dribble that forms unburned hydrocarbons and decreases the engine thermal efficiency in modern engines. Understanding of the fuel dribbling process is of great importance to establish its minimization strategy for optimal use of conventional fuels. However, the detailed needle dynamics and in- and near-nozzle flow characteristics governing the fuel dribble process have not been thoroughly understood. In this study, the needle dynamics, in- and near-nozzle flow characteristics and fuel dribble of a mini-sac type three-hole diesel injector were investigated using a highspeed X-ray phase-contrast imaging technique at different injection pressures. The results showed that an increase in injection pressure increased the flow evacuation velocity at the needle close that induced a more intense fuel cavitation and air ingestion inside the nozzle. The fuel dribbling process showed a high shot-toshot deviation. A statistical analysis of 50-shot results exhibited two breakup modes of fuel dribble determined by the flow evacuation velocity at the needle close and presence of air ingestion. In the first mode, the fast breakup with a short residence time of fuel dribble occurred. Meanwhile, the dripping of undisturbed liquid column with a long residence time of fuel dribble occurred in the second mode. An increase in injection pressure increased the population of the first mode due to more intense air ingestion that primarily caused by an increase in needle closing speed other than an increase in peak injection velocity. Based on the results, the formation mechanism and control strategies of the fuel dribble from modern diesel injectors were discussed.

Moon, Seoksu↗

Data-driven materials research enabled by natural language processing and information extraction

Given the emergence of data science and machine learning throughout all aspects of society, but particularly in the scientific domain, there is increased importance placed on obtaining data. Data in materials science are particularly heterogeneous, based on the significant range in materials classes that are explored and the variety of materials properties that are of interest. This leads to data that range many orders of magnitude, and these data may manifest as numerical text or image-based information, which requires quantitative interpretation. The ability to automatically consume and codify the scientific literature across domains - enabled by techniques adapted from the field of natural language processing - therefore has immense potential to unlock and generate the rich datasets necessary for data science and machine learning. This review focuses on the progress and practices of natural language processing and text mining of materials science literature and highlights opportunities for extracting additional information beyond text contained in figures and tables in articles. Here, we discuss and provide examples for several reasons for the pursuit of natural language processing for materials, including data compilation, hypothesis development, and understanding the trends within and across fields. Current and emerging natural language processing methods along with their applications to materials science are detailed. We, then, discuss natural language processing and data challenges within the materials science domain where future directions may prove valuable.

36 MATERIALS SCIENCE↗

Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First application of dynamic infrared imaging in boron neutron capture therapy for cutaneous malignant melanoma

Purpose: The purpose of this study is to assess the potential of dynamic infrared imaging (DIRI) as a functional, noninvasive technique for evaluating the skin acute toxicity and tumor control within the framework of the Argentine boron neutron capture therapy (BNCT) program for cutaneous malignant melanoma. Methods: Two patients enrolled in the Argentine phase I/II BNCT clinical trial for cutaneous malignant melanoma were studied with DIRI. An uncooled infrared camera, providing a video output signal, was employed to register the temperature evolution of the normal skin and tumor regions in patients subjected to a mild local cooling (cold stimulus). In order to study the spatial correlation between dose and acute skin reactions, three-dimensional representations of the superficial dose delivered to skin were constructed and cameralike projections of the dose distribution were coregistered with visible and infrared images. Results: The main erythematous reaction was observed clinically between the second and fifth week post-BNCT. Concurrently, with its clinical onset, a reactive increase above the basal skin temperature was observed with DIRI in the third week post-BNCT within regions that received therapeutic doses. Melanoma nodules appeared as highly localized hyperthermic regions. 2 min after stimulus, these regions reached a temperature plateau and increased in size. Temperature differences with respect to normal skin up to 10 deg. C were observed in the larger nodules. Conclusions: Preliminary results suggest that DIRI, enhanced by the application of cold stimuli, may provide useful functional information associated with the metabolism and vasculature of tumors and inflammatory processes related to radiation-induced changes in the skin as well. These capabilities are aimed at complementing the clinical observations and standard imaging techniques, such as CT and Doppler ultrasound.

61 RADIATION PROTECTION AND DOSIMETRY↗

An immersed interface method for microstructure-scale electrochemical battery models: numerical formulation and performance portable implementation

We present the numerical formulation, verification, and performance portable implementation of an immersed interface method for microstructure scale electrochemical modeling of batteries. The innovation in this approach is the resolution of chemical species and electrostatic potential discontinuities at active interfaces without the use of interface conforming unstructured grids. A unified formulation on Cartesian grids for all domains (electrodes and electrolyte) is used with interfacial flux conditions applied using volume fraction or “color” function gradients. We have developed one dimensional and two dimensional test cases with analytic solutions for electrochemical modeling using which we verified the consistency and accuracy of our scheme. Our solver is also validated against solutions from a macroscale model and an unstructured multi-subdomain solver for a full lithium ion cell. We then demonstrated the utility of our solver on an image-based complex battery electrode microstructure at high charging rate. Our technique also exhibits good scalability on distributed memory architectures using central processing units (CPU), with problem sizes up to 1.8 billion degrees of freedom and with 5400 ranks. Initial performance studies of our open-source performance portable solver showed about 70 times speed up using a graphics processing unit (GPU) compared to single compute core for a problem with 4 million cells.

25 ENERGY STORAGE↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensing performances of ZnO nanostructures grown under different oxygen pressures to hydrogen

Graphical abstract: Display Omitted Highlights: ► Surface morphology depends on the oxygen pressure. ► Structural degradation was observed for the ZnO samples when oxygen pressure was overhigh. ► The sensitivity of the ZnO-based sensors increase with grown oxygen pressure. -- Abstract: For extensive use in an industrialized process of individual ZnO nanostructures applied in gas sensors, a simple, inexpensive, and safe synthesis process is required. Here, nanostructured ZnO films were grown by a pulsed laser deposition technique under different oxygen pressures. Scanning electron microscopy images show nanopores, nanotips, and nanoparticles are obtained and energy dispersive X-ray spectroscopy data indicate oxygen concentration of the synthesized samples increases monotonously with oxygen pressure. The sensor based on ZnO with high oxygen concentration has high sensitivity, rapid response (9 s) and recovery (80 s) behavior to 500 ppm hydrogen below 150 °C. Experimental data indicate that high oxygen concentration effectively improves the sensing properties of nanostructured ZnO.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond photoelectron point projection microscope

By utilizing a nanometer ultrafast electron source in a point projection microscope we demonstrate that images of nanoparticles with spatial resolutions of the order of 100 nanometers can be obtained. The duration of the emission process of the photoemitted electrons used to make images is shown to be of the order of 100 fs using an autocorrelation technique. The compact geometry of this photoelectron point projection microscope does not preclude its use as a simple ultrafast electron microscope, and we use simple analytic models to estimate temporal resolutions that can be expected when using it as a pump-probe ultrafast electron microscope. These models show a significant increase in temporal resolution when comparing to ultrafast electron microscopes based on conventional designs. We also model the microscopes spectroscopic abilities to capture ultrafast phenomena such as the photon induced near field effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗