Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Characterizing Cool Giant Planets in Reflected Light

While the James Webb Space Telescope will detect and characterize extrasolar planets by transit and direct imaging, a new generation of telescopes will be required to detect and characterize extrasolar planets by reflected light imaging. NASA's WFIRST space telescope, now in development, will image dozens of cool giant planets at optical wavelengths and will obtain spectra for several of the best and brightest targets. This mission will pave the way for the detection and characterization of terrestrial planets by the planned LUVOIR or HabEx space telescopes. In my presentation I will discuss the challenges that arise in the interpretation of direct imaging data and present the results of our group's effort to develop methods for maximizing the science yield from these planned missions.

James Webb Space Telescope↗

Astrometric gravitational-wave detection via stellar interferometry

Here, we evaluate the potential for gravitational-wave (GW) detection in the frequency band from 10 nHz to 1 μ Hz using extremely high-precision astrometry of a small number of stars. In particular, we argue that nonmagnetic, photometrically stable, hot white dwarfs (WD) located at ~kpc distances may be optimal targets for this approach. Previous studies of astrometric GW detection have focused on the potential for less precise surveys of large numbers of stars; our work provides an alternative optimization approach to this problem. Interesting GW sources in this band are expected at characteristic strains around h c ~10 -17 × (μHz/ $f$ GW ). The astrometric angular precision required to see these sources is Δθ~h c after integrating for a time T~1/$f$GW. We show that jitter in the photometric center of WD of this type due to starspots is bounded to be small enough to permit this high-precision, small-N approach. We discuss possible noise arising from stellar reflex motion induced by orbiting objects and show how it can be mitigated. The only plausible technology able to achieve the requisite astrometric precision is a space-based stellar interferometer. Such a future mission with few-meter-scale collecting dishes and baselines of $\mathscr{O}$(100 km ) is sufficient to achieve the target precision. This collector size is broadly in line with the collectors proposed for some formation-flown, space-based astrometer or optical synthetic-aperture imaging-array concepts proposed for other science reasons. The proposed baseline is however somewhat larger than the km-scale baselines discussed for those concepts, but we see no fundamental technical obstacle to utilizing such baselines. A mission of this type thus also holds the promise of being one of the few ways to access interesting GW sources in this band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cassini/CIRS Observations of Saturn's "Storm Alley"

In the Voyager era storms on Saturn were observed predominantly in the northern hemisphere, however, in recent years storm activity has been confined to a narrow range of latitudes referred to as "storm alley" (approx.40degS planetographic latitude). Throughout Cassini's prime mission storms have been detected by two independent instruments: ISS through dayside images and RPWS using radio emissions from Saturn Electrostatic Discharges (SED's) (Dyudina et al. 2007). Analysis of these storms indicates that the cloud tops are in the 200 - 500rnbar altitude range. During Saturn's Equinox, in August 2009, lSS imaged lightning on the night side in storm alley when ring-shine was at a minimum (Dyudina et al. 2010). This study indicates that lightning may have originated as deep as the water cloud. Decently, Cassini/CIRS was targeted at storm alley while a storm, originally detected by amateurs, was ongoing (March 2010). Phosphine can be used as a tracer of vertical transport because it is a disequilibrium species that falls off with altitude in the upper troposphere. CIRS can measure temperature and phosphine abundance independently in the altitude range where these cloud tops occur. Early analysis of these data shows stronger phosphine absorption at storm longitudes. This is an indication that powerful updrafts were dredging material upward into the upper troposphere. The results of the analysis of the March 2010 CIRS observations of storm alley will be presented.

Hesman, Brigette E.↗

Quantum-enhanced detection of viral cDNA via luminescence resonance energy transfer using upconversion and gold nanoparticles

Abstract The COVID-19 pandemic has profoundly impacted global economies and healthcare systems, revealing critical vulnerabilities in both. In response, our study introduces a sensitive and highly specific detection method for cDNA, leveraging Luminescence Resonance Energy Transfer (LRET) between upconversion nanoparticles (UCNPs) and gold nanoparticles (AuNPs), and achieves a detection limit of 242 fM for SARS-CoV-2 cDNA. This innovative sensing platform utilizes UCNPs conjugated with one primer and AuNPs with another, targeting the 5′ and 3′ ends of the SARS-CoV-2 cDNA, respectively, enabling precise differentiation of mismatched cDNA sequences and significantly improving detection specificity. Through rigorous experimental analysis, we established a quenching efficiency range from 10.4 % to 73.6 %, with an optimal midpoint of 42 %, thereby demonstrating the superior sensitivity of our method. Our work uses SARS-CoV-2 cDNA as a model system to demonstrate the potential of our LRET-based detection method. This proof-of-concept study highlights the adaptability of our platform for future diagnostic applications. Instrumental validation confirms the synthesis and formation of AuNPs, addressing the need for experimental verification of the preparation of nanomaterial. Our comparative analysis with existing SARS-CoV-2 detection methods revealed that our approach provides a low detection limit and high specificity for target cDNA sequences, underscoring its potential for targeted COVID-19 diagnostics. This study demonstrates the superior sensitivity and adaptability of using UCNPs and AuNPs for cDNA detection, offering significant advances in rapid, accessible diagnostic technologies. Our method, characterized by its low detection limit and high precision, represents a critical step forward in developing next-generation biosensors for managing current and future viral outbreaks. By adjusting primer sequences, this platform can be tailored to detect other pathogens, contributing to the enhancement of global healthcare responsiveness and infectious disease control.

Esmaeili, Shahriar [Institute for Quantum Science ↗

Vertical column dual-comb spectroscopy to a TBS

Open-path dual-frequency-comb spectroscopy (DCS) is a broadband, high spectral resolution, and high precision method for measuring gas concentrations over kilometer-scale paths. It has been used for detection and quantification of emissions of pollutants, hazardous gasses, and greenhouse gasses (GHGs). DCS has been shown to measure trace-gas mixing ratios with 0.14%-0.4% agreement between instruments. To achieve high signal-to-noise ratios (SNRs) with DCS, comb light is targeted onto a retroreflector at the end of the measurement path, which returns the signal to a detector co-located with the launch signal. Installing the retroreflector on a mobile platform such as a balloon or unmanned aerial vehicle (UAV) extends the capabilities of DCS by enabling variable path lengths, greater mobility, and access to higher altitudes. Mobile-target DCS has many uses in plume and leak detection, emissions modeling, and planetary boundary layer (PBL) studies. It is a promising method for observing vertical distributions of GHGs and mixing processes in the PBL, which are difficult to measure but important for pollution and climate monitoring as well as for understanding transport of gasses through the atmosphere. Tethered balloons are an intriguing platform because they enable longer flight durations and higher altitudes than easily obtainable with a UAV and thus allow for column measurements up to and above the PBL. New measurements completed in October/November 2024 reach the highest altitudes above ground level yet achieved by mobile-target DCS. For these measurements, the retroreflector was mounted on a 7 m diameter tethered helium balloon. An actively tracking gimbal on the ground holds the DCS launch telescope and keeps the 5 cm beam pointed onto the retroreflector while the balloon is lifted, lowered, and moved by wind and turbulence.

atmosphere↗

Characterizing Heterogeneous Mixtures of Assembled States of the Tobacco Mosaic Virus Using Charge Detection Mass Spectrometry

The tobacco mosaic viral capsid protein (TMV) is a frequent target for derivatization for myriad applications, including drug delivery, biosensing, and light harvesting. However, solutions of the stacked disk assembly state of TMV are difficult to characterize quantitatively due to their large size and multiple assembled states. Charge detection mass spectrometry (CDMS) addresses the need to characterize heterogeneous populations of large protein complexes in solution quickly and accurately. Using CDMS, previously unobserved assembly states of TMV, including 16-monomer disks and odd-numbered disk stacks, have been characterized. We additionally employed a peptide-protein conjugation reaction in conjunction with CDMS to demonstrate that modified TMV proteins do not redistribute between disks. Finally, this technique was used to discriminate between protein complexes of near-identical mass but different configurations. In conclusion, we have gained a greater understanding of the behavior of TMV, a protein used across a broad variety of fields and applications, in the solution state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emerging Per- and Polyfluoroalkyl Substances in Tap Water from the American Healthy Homes Survey II

Humans experience widespread exposure to anthropogenic per- and polyfluoroalkyl substances (PFAS) through various media, which can lead to a wide range of negative health impacts. Tap water is an important source of exposure in communities with any degree of contamination but routine or large-scale PFAS monitoring often depends on targeted analytical methods limited to measuring specific PFAS. We analyzed 680 tap water samples from the American Healthy Homes Survey II for PFAS using non-targeted analysis (NTA) to expand the range of detectable PFAS. Based on detection frequency and relative abundance, about half of the identified PFAS were found only by NTA. We identified (with varying degrees of confidence) 75 distinct PFAS, including 57 exclusively detected by NTA. The identified PFAS are members of seven structural subclasses differentiated by their head groups and degree of fluorination. Clustering analysis categorized the PFAS into four coabundance groups dominated by specific PFAS subclasses. One group uniquely identified by NTA contains zwitterionic PFAS and other PFAS transformation products which are likely associated with aqueous firefighting foam contaminants in a small number of spatially correlated samples. These results help further characterize the scope of exposure to emerging PFAS experienced by the U.S. population via tap water and augment nationwide targeted-PFAS monitoring programs.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Generic Sensor Modeling Using Pulse Method

Recent development of high spatial resolution satellites such as IKONOS, Quickbird and Orbview enable observation of the Earth's surface with sub-meter resolution. Compared to the 30 meter resolution of Landsat 5 TM, the amount of information in the output image was dramatically increased. In this era of high spatial resolution, the estimation of spatial quality of images is gaining attention. Historically, the Modulation Transfer Function (MTF) concept has been used to estimate an imaging system's spatial quality. Sometimes classified by target shapes, various methods were developed in laboratory environment utilizing sinusoidal inputs, periodic bar patterns and narrow slits. On-orbit sensor MTF estimation was performed on 30-meter GSD Landsat4 Thematic Mapper (TM) data from the bridge pulse target as a pulse input . Because of a high resolution sensor s small Ground Sampling Distance (GSD), reasonably sized man-made edge, pulse, and impulse targets can be deployed on a uniform grassy area with accurate control of ground targets using tarps and convex mirrors. All the previous work cited calculated MTF without testing the MTF estimator's performance. In previous report, a numerical generic sensor model had been developed to simulate and improve the performance of on-orbit MTF estimating techniques. Results from the previous sensor modeling report that have been incorporated into standard MTF estimation work include Fermi edge detection and the newly developed 4th order modified Savitzky-Golay (MSG) interpolation technique. Noise sensitivity had been studied by performing simulations on known noise sources and a sensor model. Extensive investigation was done to characterize multi-resolution ground noise. Finally, angle simulation was tested by using synthetic pulse targets with angles from 2 to 15 degrees, several brightness levels, and different noise levels from both ground targets and imaging system. As a continuing research activity using the developed sensor model, this report was dedicated to MTF estimation via pulse input method characterization using the Fermi edge detection and 4th order MSG interpolation method. The relationship between pulse width and MTF value at Nyquist was studied including error detection and correction schemes. Pulse target angle sensitivity was studied by using synthetic targets angled from 2 to 12 degrees. In this report, from the ground and system noise simulation, a minimum SNR value was suggested for a stable MTF value at Nyquist for the pulse method. Target width error detection and adjustment technique based on a smooth transition of MTF profile is presented, which is specifically applicable only to the pulse method with 3 pixel wide targets.

Helder, Dennis L.↗

The Sloan Lens ACS Survey. I. A Large Spectroscopically Selected Sample of Massive Early-Type Lens Galaxies

The Sloan Lens ACS (SLACS) Survey is an efficient Hubble Space Telescope (HST) Snapshot imaging survey for new galaxy-scale strong gravitational lenses. The targeted lens candidates are selected spectroscopically from the Sloan Digital Sky Survey (SDSS) database of galaxy spectra for having multiple nebular emission lines at a redshift significantly higher than that of the SDSS target galaxy. The SLACS survey is optimized to detect bright early-type lens galaxies with faint lensed sources in order to increase the sample of known gravitational lenses suitable for detailed lensing, photometric, and dynamical modeling. In this paper, the first in a series on the current results of our HST Cycle 13 imaging survey, we present a catalog of 19 newly discovered gravitational lenses, along with nine other observed candidate systems that are either possible lenses, nonlenses, or nondetections. The survey efficiency is thus >=68%. We also present Gemini 8 m and Magellan 6.5 m integral-field spectroscopic data for nine of the SLACS targets, which further support the lensing interpretation. A new method for the effective subtraction of foreground galaxy images to reveal faint background features is presented. We show that the SLACS lens galaxies have colors and ellipticities typical of the spectroscopic parent sample from which they are drawn (SDSS luminous red galaxies and quiescent MAIN sample galaxies), but are somewhat brighter and more centrally concentrated. Several explanations for the latter bias are suggested. The SLACS survey provides the first statistically significant and homogeneously selected sample of bright early-type lens galaxies, furnishing a powerful probe of the structure of early-type galaxies within the half-light radius. The high confirmation rate of lenses in the SLACS survey suggests consideration of spectroscopic lens discovery as an explicit science goal of future spectroscopic galaxy surveys.

galaxies↗

Hypervelocity Impact (HVI): WLE High Fidelity Specimen RCC16R - Volume 7

During 2003 and 2004, the Johnson Space Center's White Sands Testing Facility in Las Cruces, New Mexico conducted hypervelocity impact tests on the space shuttle wing leading edge. Hypervelocity impact tests were conducted to determine if Micro-Meteoroid/Orbital Debris impacts could be reliably detected and located using simple passive ultrasonic methods. The objective of Target RCC16R was to study hypervelocity impacts through the reinforced carbon-carbon (RCC) panels of the Wing Leading Edge. Impact damage was detected using lightweight, low power instrumentation capable of being used in flight.

Gorman, Michael R.↗

Swept Frequency Laser Metrology System

A swept frequency laser ranging system having sub-micron accuracy that employs multiple common-path heterodyne interferometers, one coupled to a calibrated delay-line for use as an absolute reference for the ranging system. An exemplary embodiment uses two laser heterodyne interferometers to create two laser beams at two different frequencies to measure distance and motions of target(s). Heterodyne fringes generated from reflections off a reference fiducial X(sub R) and measurement (or target) fiducial X(sub M) are reflected back and are then detected by photodiodes. The measured phase changes Delta phi(sub R) and Delta phi (sub m) resulting from the laser frequency swept gives target position. The reference delay-line is the only absolute reference needed in the metrology system and this provides an ultra-stable reference and simple/economical system.

Zhao, Feng↗

Measurement of the Neutron Electromagnetic Form Factors at High Momentum Transfer Using a Polarized 3He Target at Jefferson Lab

Ever since the composite structure of nucleons was uncovered, many experiments have been commissioned with the purpose of extracting parameters that shape our understanding of this structure. Form factors are powerful tools that rest at the forefront of the nucleon structure study. In the non-relativistic limit, they describe the magnetic and charge distributions inside the nucleon. The GEn-II experiment, which ran in Hall A of Jefferson Lab as a part of the SuperBigbite Spectrometer (SBS) program, aimed to extract the ratio of the neutron’s electric to magnetic Sachs form factors (GnE/GnM. This was accomplished using the double polarization technique: scattering polarized electrons with initial energies up to 8.45 GeV off high-density polarized 3He targets. The experiment was a coincidence measurement, with the scattered electrons detected in the BigBite Spectrometer and the recoil nucleons in a hadron calorimeter, a part of the SuperBigbite Spectrometer. The convection-style target cells used in this experiment have a 60cm long target chamber, an increase from the 40 cm cell used in the most recent polarized 3He target experiment. In addition, the cells were optically pumped from two sides of the pumping chamber. These improvements in design and functionality introduced world-record-breaking luminosity. This thesis presents preliminary results of the GEn-II experiment for the following 4-momentum transfer (Q2) values: 2.93, 6.76, and 9.78 GeV2, in addition to target performance and preliminary polarimetry results.

Presley, Hunter [Univ. of Virginia, Charlottesvill↗

Source-agnostic gravitational-wave detection with recurrent autoencoders

Abstract We present an application of anomaly detection techniques based on deep recurrent autoencoders (AEs) to the problem of detecting gravitational wave (GW) signals in laser interferometers. Trained on noise data, this class of algorithms could detect signals using an unsupervised strategy, i.e. without targeting a specific kind of source. We develop a custom architecture to analyze the data from two interferometers. We compare the obtained performance to that obtained with other AE architectures and with a convolutional classifier. The unsupervised nature of the proposed strategy comes with a cost in terms of accuracy, when compared to more traditional supervised techniques. On the other hand, there is a qualitative gain in generalizing the experimental sensitivity beyond the ensemble of pre-computed signal templates. The recurrent AE outperforms other AEs based on different architectures. The class of recurrent AEs presented in this paper could complement the search strategy employed for GW detection and extend the discovery reach of the ongoing detection campaigns.

47 OTHER INSTRUMENTATION↗

Peptoid-Based Programmable 2D Nanomaterial Sensor for Selective and Sensitive Detection of H 2 S in Live Cells

During the past decades, a variety of two-dimensional (2D) nanosheets have been developed through supramolecular self-assembly. Among them, those assembled from sequence-defined molecules have received particularly attention because they enable a precise displaying of functional groups, including fluorescent dyes, within nanosheet surfaces. On the other hand, due to the fluorescence self-quenching, synthesis of organic 2D nanosheets exhibiting high fluorescence quantum yields is a significant challenge. Herein, we report the utilization of H 2 S-responsive probes as peptoid sidechains to design and synthesize crystalline 2D nanomembranes (2DNMs) as selective and sensitive H 2 S sensors. These 2DNM sensors exhibit a high quantum yield as a result of high crystallinity and tunable probe density. Compared with amorphous state of peptoid assembly and pre-assembled peptoid-probe conjugates, these crystalline 2DNM sensors exhibit a significantly strong fluorescence intensity and a high sensitivity (~ 0.36 nM). By sonication-cutting these 2DNM sensors into a colloidal form in aqueous solution, we further demonstrated the use of colloidal 2DNMs for detecting both exogenous and endogenous H 2 S inside cells or targeted cell organelles. As far as we know, this is the first example of using sequence-defined 2D nanomaterials for selective and sensitive detection of H 2 S. Because peptoids are biocompatible and peptoid-based 2DNMs are highly programmable, we expect that this new class of 2DNM sensors offer great potentials for detecting H 2 S and for biological applications.

2D nanomaterials↗

A Quantum Dot Nanobiosensor for Rapid Detection of Botulinum Neurotoxin Serotype E

Botulinum neurotoxins (BoNTs) are potent toxins produced by Clostridium bacteria that are responsible for the illness botulism and are listed as bioterrorism agents. BoNT serotype E (BoNT/E) is one of four BoNT serotypes that cause human botulism and is the second most frequent cause of foodborne botulism. Rapid detection and discrimination of BoNT serotypes implicated in human disease are critical for ensuring timely treatment of patients and identifying sources of toxins, but there have been few reported detection methods for BoNT/E and even fewer methods usable for BoNT serotyping. We report a nanobiosensor based on Forster resonance energy transfer (FRET) between semiconductor nanocrystals (quantum dots, QDs) and dark quencher-labeled peptide probes to detect biologically active BoNT/E in aqueous media. The peptide probes contain a specific cleavage site for active BoNT/E. QD photoluminescence, which changes intensity due to FRET when the peptide probe is cleaved, was used to indicate toxin presence and quantity. The detection of a BoNT/E light chain (LcE) and holotoxin was observed within 3 h. The limits of detection were 0.02 and 2 ng/mL for LcE and holotoxin, respectively. The nanobiosensor shows good specificity toward the target in tests with nontarget BoNT serotypes. The high sensitivity, simple operation, short detection time, and ability to be used in parallel with probes developed for other BoNT serotypes indicate that the nanobiosensor will be useful for rapid BoNT/E detection and serotype discrimination in food analysis.

botulinum neurotoxin E↗

Carrier-assisted One-pot Sample Preparation for Targeted Proteomics Analysis of Small Numbers of Human Cells

Protein analysis of small numbers of human cells is primarily achieved by targeted proteomics with antibody-based immunoassays, which have inherent limitations (e.g., low multiplex and unavailability of antibodies for new proteins). Mass spectrometry (MS)-based targeted proteomics has emerged as an alternative because it is antibody-free, high multiplex, and has high specificity and quantitation accuracy. Recent advances in MS instrumentation make MS-based targeted proteomics possible for multiplexed quantification of highly abundant proteins in single cells. However, there is a technical challenge for effective processing of single cells with minimal sample loss for MS analysis. To address this issue, we have recently developed a convenient protein carrier-assisted one-pot sample preparation coupled with liquid chromatography (LC) - selected reaction monitoring (SRM) termed cLC-SRM for targeted proteomics analysis of small numbers of human cells. This method capitalizes on using the combined excessive exogenous protein as a carrier and low-volume one-pot processing to greatly reduce surface adsorption losses as well as high-specificity LC-SRM to effectively address the increased dynamic concentration range due to the addition of exogeneous carrier protein. Its utility has been demonstrated by accurate quantification of most moderately abundant proteins in small numbers of cells (e.g., 10-100 cells) and highly abundant proteins in single cells. The easy-to-implement features and no need for specific devices make this method readily accessible to most proteomics laboratories. In this study, we have provided a detailed protocol for cLC-SRM analysis of small numbers of human cells including cell sorting, cell lysis and digestion, LC-SRM analysis, and data analysis. Further improvements in detection sensitivity and sample throughput are needed towards targeted single-cell proteomics analysis. We anticipate that cLC-SRM will be broadly applied to biomedical research and systems biology with the potential of facilitating precision medicine.

60 APPLIED LIFE SCIENCES↗

Potentials for change detection using Seasat synthetic aperture radar data

Synthetic aperture radars (SAR) image from a non-nadir position. Thus the orientation of the target and sensor to one another is of paramount importance. This has posed problems for data interpretation and with the potentials of radar data for change detection studies. It is possible to use Seasat radar data for change detection even though the look directions are fixed for each location. Especially in areas with repeated coverage on descending or ascending orbits or where the terrain is flat and the targets nonoriented, coverage may be sufficient to provide data for change detection. Examples of Los Angeles and the Everglades of Florida help develop and support the argument.

Bryan, M. L.↗

Probing Axion-Like-Particles at the CERN Gamma Factory

We report the aim of the proposed CERN Gamma Factory is to produce ≈10 17 photons per second with energies up to 400 MeV. The photon beam intensity is expected to be a factor of $\mathcal{O}$(10 7 ) larger than that of the presently available photon beams in the MeV energy range. In this work, its potential to probe physics beyond the Standard Model is explored. In particular, searches for axion like particles (ALPs) with dominant couplings to photons are discussed and various production scenarios - fixed target, photon-photon collision, and conversion by a magnetic field - and detection schemes considered - via decay to photons or back-conversion. It is found that the Gamma Factory in a fixed target mode can probe ALPs with mass m a ≲ $\mathcal{O}$(100 MeV) and decay constants larger than 10 7 GeV, improving by an order of magnitude the discovery potential of previous beam dump experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗