Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

ISIS-B spacecraft magnetic tests

Magnetic tests of the ISIS B spacecraft were conducted to determine the various magnetic moments of the spacecraft, evalute its spin and attitude control systems, and calibrate the six onboard magnetometer probes. Test procedures and equipment are described. Techniques for evaluting the data are discussed, and test results are presented. The spacecraft's magnetic characteristics were found to be satisfactory. Proper threshold values for gating the torquing coils were obtained. The onboard magnetometers were satisfactorily calibrated.

Boyle, J. C.↗

Active transmission isolation/rotor loads measurement system

Modifications were incorporated into a helicopter active transmission isolation system to provide the capability of utilizing the system as a rotor force measuring device. These included; (1) isolator redesign to improve operation and minimize friction, (2) installation of pressure transducers in each isolator, and (3) load cells in series with each torque restraint link. Full scale vibration tests performed during this study on a CH-53A helicopter airframe verified that these modifications do not degrade the systems wide band isolation characteristics. Bench tests performed on each isolator unit indicated that steady and transient loads can be measured to within 1 percent of applied load. Individual isolator vibratory load measurement accuracy was determined to be 4 percent. Load measurement accuracy was found to be independent of variations in all basic isolator operating characteristics. Full scale system load calibration tests on the CH-53A airframe established the feasibility of simultaneously providing wide band vibration isolation and accurate measurement of rotor loads. Principal rotor loads (lift, propulsive force, and torque) were measured to within 2 percent of applied load.

Kenigsberg, I. J.↗

Static noise tests on augmentor wing jet STOL research aircraft (C8A Buffalo)

Results are presented for full scale ground static acoustic tests of over-area conical nozzles and a lobe nozzle installed on the Augmentor Wing Jet STOL Research Aircraft, a modified C8A Buffalo. The noise levels and spectrums of the test nozzles are compared against those of the standard conical nozzle now in use on the aircraft. Acoustic evaluations at 152 m (500 ft), 304 m (1000 ft), and 1216 m (4000 ft) are made at various engine power settings with the emphasis on approach and takeoff power. Appendix A contains the test log and propulsion calculations. Appendix B gives the original test plan, which was closely adhered to during the test. Appendix C describes the acoustic data recording and reduction systems, with calibration details.

Marrs, C. C.↗

Precision frequency sources

The development of precision oscillators for time and frequency standards is discussed. The applications of the oscillators to radio communication, research projects, navigation systems, and calibration sources are reported. The status of a cesium beam stabilized oscillator is examined. Photographs of the components are provided. The performance of quartz and rubidium oscillators is compared with the performance of cesium resonators.

Mccoubrey, A. O.↗

Absolute radiometric calibration of detectors between 200-600 A

A description is given of the experimental methods used in the calibration procedure, taking into account the source of radiant energy, the monochromator, the absolute standard detector, and the transfer standards. The experimental apparatus is discussed. A graph showing the effect of beam motion on the detected signal is presented and a block diagram of the calibration electronic system is provided.

Saloman, E. B.↗

Satellite laser ranging work at the Goddard Space Flight Center

The paper describes the satellite laser ranging system at the Goddard Space Flight Center, its range and accuracy capabilities, and planned improvements for future systems. Major subsystems are described, including the laser, optical/mechanical, receiver, computer/software, timing, and laser data preprocessing subsystems. Operational considerations are examined, with attention given the mobile station layout, manpower requirements, and transportability. System performance is considered, with emphasis on system accuracy (calibration, stability, clock synchronization, atmospheric propagation correction) and range capability.

Mcgunigal, T. E.↗

Landsat-D data acquisition and processing

The Landsat-D system, in which S-band and X-band data links will provide real-time direct transmission of sensor data, is described. System performance objectives include input data quantity of 200 MSS scenes/day and 100 TM scenes/day by the Domestic Communication Satellite, and processing capability, in a pipeline mode, of 2.6 x 10 to the 11th input bits of sensor data per 16-hour day. Data processing techniques, including automated cloudcover assessment, control point library build system, radiometric calibration, and geometric correction are discussed.

Smith, P. L., Jr.↗

Laser measurement of extinction coefficients of highly absorbing liquids

A coaxial dual-channel laser system has been developed for the measurement of extinction coefficients of highly absorbing liquids. An empty wedge-shaped sample cell is first translated laterally through a He-Ne laser beam to measure the differential thickness using interference fringes in reflection. The wedge cell is carefully filled with the oil sample and translated through the coaxially positioned dye laser beam for the differential attenuation or extinction measurement. Optional use of the instrumentation as a single-channel extinction measurement system and also as a refractometer is detailed. The system and calibration techniques were applied to the measurement of two crude oils whose extinction values were required to complete the analysis of airborne laser data gathered over four controlled spills.

Hoge, F. E.↗

Spectral atmospheric observations at Nantucket Island, May 7-14, 1981

An experiment was conducted by the National Langley Research Center to measure atmospheric optical conditions using a 10-channel solar spectral photometer system. This experiment was part of a larger series of multidisciplinary experiments performed in the area of Nantucket Shoals aimed at studying the dynamics of phytoplankton production processes. Analysis of the collected atmospheric data yield total and aerosol optical depths, transmittances, normalized sky radiance distributions, and total and sky irradiances. Results of this analysis may aid in atmospheric corrections of remote sensor data obtained by several sensors overflying the Nantucket Shoals area. Recommendations are presented concerning future experiments using the described solar photometer system and calibration and operational deficiencies uncovered during the experiment.

Talay, T. A.↗

Multichannel scanning radiometer for remote sensing cloud physical parameters

A multichannel scanning radiometer developed for remote observation of cloud physical properties is described. Consisting of six channels in the near infrared and one channel in the thermal infrared, the instrument can observe cloud physical parameters such as optical thickness, thermodynamic phase, cloud top altitude, and cloud top temperature. Measurement accuracy is quantified through flight tests on the NASA CV-990 and the NASA WB-57F, and is found to be limited by the harsh environment of the aircraft at flight altitude. The electronics, data system, and calibration of the instrument are also discussed.

Curran, R. J.↗

The Deep Space Network: Noise temperature concepts, measurements, and performance

The use of higher operational frequencies is being investigated for improved performance of the Deep Space Network. Noise temperature and noise figure concepts are used to describe the noise performance of these receiving systems. The ultimate sensitivity of a linear receiving system is limited by the thermal noise of the source and the quantum noise of the receiver amplifier. The atmosphere, antenna and receiver amplifier of an Earth station receiving system are analyzed separately and as a system. Performance evaluation and error analysis techniques are investigated. System noise temperature and antenna gain parameters are combined to give an overall system figure of merit G/T. Radiometers are used to perform radio ""star'' antenna and system sensitivity calibrations. These are analyzed and the performance of several types compared to an idealized total power radiometer. The theory of radiative transfer is applicable to the analysis of transmission medium loss. A power series solution in terms of the transmission medium loss is given for the solution of the noise temperature contribution.

Stelzried, C. T.↗

Water vapor measurement system in global atmospheric sampling program, appendix

The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.

Englund, D. R.↗

Predicted magnitudes and colors from cool-star model atmospheres

An intercomparison of model stellar atmospheres and observations of real stars can lead to a better understanding of the relationship between the physical properties of stars and their observed radiative flux. In this spirit we have determined wide-band and narrow-band magnitudes and colors for a subset of models of K and M giant and supergiant stars selected from the grid of 40 models by Johnson, Bernat and Krupp (1980) (hereafter referred to as JBK). The 24 models selected have effective temperatures of 4000, 3800, 3600, 3400, 3200, 3000, 2750 and 2500 K and log g = 0, 1 or 2. Emergent energy fluxes (erg/ sq cm s A) were calculated at 9140 wavelengths for each model. These computed flux curves were folded through the transmission functions of Wing's 8-color system (Wing, 1971; White and Wing, 1978) and through Johnson's (1965) wide-band (BVRIJKLM) system. The calibration of the resultant magnitudes was made by using the absolute calibration of the flux curve of Vega by Schild, et al. (1971).

Johnson, H. R.↗

LANDSAT-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities, are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7% for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗

The ISPM experiment for spectral, composition and anistropy measurements of charged particles at low energie

The Heliosphere Instrument for Spectral, Composition, and Anisotropy at Low Energies (HI-SCALE) designed to measure interplanetary ions and electrons is described. Ions and electrons are detected by five separate solid-state detector telescopes oriented to give complete pitch angle coverage from the spinning spacecraft. Ion elemental abundances are determined by a telescope using a thin front detector element in a three-element telescope. Experiment operation is controlled by a microprocessor-based data system. Inflight calibration is provided by radioactive sources mounted on closable telescope covers. Ion and electron spectral information is determined using broad-energy-range rate channels, and a pulse-height analyzer for more detailed spectra. The instrument weighs 5.775 kg and uses 4.0 W power.

Lanzerotti, L. J.↗

Landsat-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7 percent for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗