Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system analysis and design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Methods for Estimating Hydrogen Fuel Tank Characteristics

The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.

42 ENGINEERING↗

Primary System Thermal Fluids Analysis Model Development for the Compact High Temperature Gas Reactor (HC-HTGR) (Final Report)

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is collaborating on the thermal hydraulic design and analysis of HC-HTGR reactor pressure vessel internals to ensure the reactor maintains sufficient safety margins during normal operation, shutdown, and accident conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Multi-Dimensional Benefit Assessment of Automated Mobility Platforms (AMP) for Large Facilities

Automated Mobility Platform (AMP) is a general term for intelligently managed passenger mobility systems that leverage automation and electrification to improve system performance and sustainability through the integration of real-time data streams with advanced decision-making processes tailored for use in large facilities. Using airports as an example, the rapid growth in air travel demand has led to facility expansions and congested terminals, which directly impacts equity (e.g., increased challenges for passengers with reduced mobility [PRMs]) and sustainability - both of which are important metrics often neglected during the engineering design process. Therefore, to evaluate systems and inform critical decisions more effectively, a holistic evaluation framework is proposed that includes equity, sustainability, and infrastructure perspectives - referred to as a multidimensional benefit assessment. More specifically, the following analysis focuses on: (1) mobility, with emphasis on travel time and accessibility within an airport, contrasting existing systems with the proposed AMP system; (2) equity analysis, specifically to the PRM community, but with an eye to the whole of society; (3) energy consumption and greenhouse gas (GHG) emissions associated with intra-airport mobility, comparing and contrasting modes as well as impacts on overall airport operations efficiency; and (4) fundamental changes in building design enabled by AMPs for larger and more flexible, functional, and energy-efficient structures.

ADVANCED PROPULSION SYSTEMS↗

Electric Vehicles at Scale (EVs@Scale) Laboratory Consortium Deep-Dive Technical Meetings: High Power Charging (HPC) Summary Report

Electric vehicle (EV) adoption will change the composition of EV charging load to higher-power charging as more medium- (MD) and heavy-duty (HD) applications are electrified, and as all vocations, including light-duty (LD) vehicles, are capable of faster charging. These shifts provide the opportunity for high-power charging (HPC) and facility equipment to evolve and improve efficiency, cost, and space. High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project designs and develops a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration approaches and technology solutions. The project addresses (1) interconnection and management of a grid-tied inverter; (2) development of a DC distribution system that is responsible for system energy management, interoperability, and DC protection; (3) modular DC/DC conversion for vehicle charging; (4) EV charging interface and DC/DC integration; and (5) smart charge control and vehicle-to-edge (vehicle-to-building [V2B], vehicle-to-everything [V2X]) capability. This summary presentation is the first technical progress output of the project. It provides insight for the first deep-dive technical meeting outputs in terms of research presentations and also includes summary of the discussions occurred in the follow-up breakout sessions. The summary presentation covers three technical areas: (1) HPC: State of the art power architectures and the design of the power electronics, (2) Modeling, energy management, and power control in the HPC station, and (3) Codes and standards work that are in line with the previous two topic areas.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Optimum Multinozzle Configuration for Minimizing the Rayleigh Integral During High-Frequency Transverse Instabilities

This paper develops a formalism for optimizing nozzle location/configuration with respect to combustion stability of high-frequency transverse modes in a can combustor. The stability of these acoustically noncompact flames was assessed using the Rayleigh integral (RI). Several key control parameters influence RI—flame angle, swirling strength, nozzle location, as well as nozzle location with respect to the acoustic mode shape. In this study, we consider a N-around-1 configuration such as typically used in a multi-nozzle can system and study the overall stability of this system for different natural transverse modes. Typically, such nozzles are distributed in a uniformly circular manner for which we study the overall RI, and for cases where RI > 0, we optimize the nozzle distribution that can reduce and minimize RI. For a fixed geometry such as a circular configuration, the analysis shows how the flame's parameters must vary across the different nozzles, to result in a relatively stable system. Additionally, for a fixed set of flame parameters, the analysis also indicates the noncircular distribution of the N nozzles that minimizes RI. Overall, the analysis aims to provide insights on designing nozzle locations around the center nozzle for minimal amplification of a given transverse mode.

42 ENGINEERING↗

Analysis of Postulated Accident Scenarios for the Transformational Challenge Reactor

The Transformational Challenge Reactor (TCR) is a helium-cooled, yttrium-hydride-moderated reactor that was designed for the U.S. Department of Energy Office of Nuclear Energy. A key objective of the TCR was to employ advanced manufacturing techniques in a nuclear system and demonstrate their potential for revolutionizing the nuclear reactor design process. One purpose of the present work is to demonstrate the safety of the TCR under postulated accidents. Based on RELAP5-3D and COMSOL analyses, the TCR remained below all current safety limits and far below the expected failure limits for the core materials. Another purpose of this work is to provide useful insights and recommendations regarding the application of RELAP5-3D to gas-cooled or other advanced reactors. A novel approach was implemented for simultaneously modeling conduction and radiation in RELAP5-3D, which was found to provide reasonable predictions of radial core, vessel, and ex-vessel heat transfer during postulated events. A multicode approach was also applied, in which high-fidelity COMSOL calculations were used to tune the radial heat transfer parameters in RELAP5-3D. The tuned RELAP5-3D model demonstrated comparable peak temperature predictions as COMSOL, despite a coarse treatment of the core in RELAP5-3D consisting of only two lumped heat structures. This high-fidelity tuning approach enabled enhanced accuracy as well as minimal complexity within the RELAP5-3D model, even for complex fuel geometric designs as in the TCR. Finally, investigations were made into the potential for flow reversal during a pressurized loss-of-forced-flow event in the TCR. The TCR is designed with downward helium flow through the core during normal operation. The RELAP5-3D model predicted that this downward flow would persist, without flow reversal, up to several days after the circulator trip. This was attributed to natural circulation hysteresis effects as have been noted in similar thermofluidic systems. Although flow stagnation and eventual reversal did not lead to unsafe TCR conditions, interesting spatial effects were observed which may have safety relevance for other reactor system designs and coolant types that are designed for downward core flow during normal operation, warranting closer investigation of the flow reversal phenomenon.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing the Potential for Sustainable Azelaic Acid Production from High-Oleic Vegetable Oil Using Two-Step Oxidative Cleavage

Azelaic acid is a renewable monomer conventionally produced via the energy-intensive ozonolysis of oleic acid. Recent advancements have enabled the use of high-oleic vegetable oils (rather than tallow-derived oleic acid) and replaced ozonolysis with two-step oxidative cleavage using hydrogen and oxygen. Although this shift would improve process safety, the financial viability and environmental implications remain uncertain. In this study, we characterized the sustainability of azelaic acid production from high-oleic vegetable oil using two-step oxidative cleavage. Process design, simulation, technoeconomic analysis (TEA), and life cycle assessment (LCA) were executed under uncertainty using BioSTEAM. The modeled system produces azelaic acid at a market-competitive minimum selling price (MSP) of 8.32 [4.93−13.34] $\$kg$ −1 (median 5th−95th percentiles), below the minimum estimated market price of 9.93 $\$kg$ −1 . Further, it has the potential to approach carbon neutrality (0.0 [−5.5 to 5.6] kg of CO 2 -eq kg −1 ) under displacement allocation. Improvements to dihydroxylation (86 to 99%) and oxidative cleavage conversions (93 to 99%) would reduce MSP to $\$5.24$ kg −1 and carbon intensity to −1.90 kg of CO 2 -eq kg −1 (displacement). Additionally, increasing the feedstock triolein content (75 to 85%) lowers MSP by $\$0.82$ kg −1 . Overall, this research demonstrates the potential for financially viable production of azelaic acid from vegetable oils and the utility of agile TEA/LCA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Lessons Learned From Ventilation and Glovebox Flooding Via Overfilling of the Wet Vacuum System in a Plutonium Facility

In the summer of 2021, operations personnel requested maintenance personnel to fill a wet vacuum (Wetvac) seal water tank in a plutonium facility at Los Alamos National Laboratory (LANL). After the filling was finished, the fill valve of the Wetvac seal water tank was left open and a ‘dead-man’ valve on an isolation line failed to close properly. After a series of other failures, the water exited the glovebox and contaminated three rooms of the first floor of the facility and an underlying area in the basement. A retrospective analysis of this event determined that there was no risk of a criticality due to the inherent design features of the ventilation system. This paper will explain the driving factors behind how this event was able to happen, as well as some of the major lessons learned that can be universally applied to other nuclear facilities. One of the main causes of the event was the delegation of work to maintenance personnel that were not qualified for the work being asked of them. Additionally, there was a lack of coordination between criticality safety engineers and facility operations equipment owners regarding equipment and connections present on the seal water tanks for the Wetvac, specifically the presence of overflow drain lines. The respective criticality safety evaluation credited an overflow drain line being present on the seal water tanks that was later found to have not been present. Lastly, there are lessons to be learned regarding equipment configuration and designing systems with safety in mind.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving and Automating Building Model Data Exchange

There are many instances throughout a project’s lifecycle where there arises a need for quick and accurate risk assessment of building designs. For example, an unexpected design change during construction may necessitate structural engineers to perform a seismic risk assessment on analytical models of the updated building design using high fidelity structural analysis software, such as ANSYS or Abaqus. However, the efficiency of such workflows often depends upon the interoperability of architectural design software and structural analysis software. When the quality of this interoperability is lacking or even non-existent, the efficiency of virtual engineering workflows is hampered, which increases project costs. A McGraw Hill industry survey of professional users of Building Information Modeling (BIM) technologies found that there is high demand for BIM interoperability for structural analysis, but that the value/difficulty ratio is currently too low for practical use. There have been efforts by the academic community to facilitate model data exchange between the architectural design and structural analysis domains, but such solutions have not been widely adopted by industry, face technical challenges, and oftentimes are limited in applicability for users of various BIM software. Therefore, INL is developing capabilities to improve, automate, and generalize model data exchange between architectural BIM software (e.g., Revit) and structural analysis software (e.g., SAP2000, ANSYS). The goal is to help expedite and automate as much of the pre-processing step for creating analytical models in finite element analysis software as reasonably as possible. Such a "BIM-to-FEA" conversion tool should provide direct benefit to end-users through accuracy, automation, quick turn-around, and wide applicability. To generalize the application of this BIM-to-FEA conversion tool and increase its useability among the many different commercial BIM software currently used by industry, the program is being developed with the concept of openBIM. OpenBIM is the application of non-proprietary, open data standards that allow for BIM model data exchange in a format that is accessible, retainable, and useable for all users. The most widely used open, non-proprietary data exchange format for BIM is the Industry Foundation Classes (IFC) schema. IFC is developed by buildingSMART international and is ISO certified (ISO 16739-1:2018). The BIM-to-FEA conversion tool is being developed for compatibility with typical commercial building designs of steel framed structures. The tool is currently capable of importing architectural BIM data of framed building structures, recognizing and extracting the aspects of the model that are required for structural analysis, adjusting the connectivity of frame members, and finally exporting to an analytical model stored in the IFC format. The exported IFC analytical model can then be imported into various openBIM compliant software, such as SAP2000. Such capabilities have already been tested on commercial software, as shown above, and continue to be improved. Work is underway to test the conversion on various commercial BIM software, develop a user-friendly interface, incorporate the program into the broader DeepLynx data warehouse project being developed by INL, and to eventually open-source the tool for the benefit of the community. Future development of the tool envisions the ability for efficient iterative risk assessment of generative building designs, all within a workflow utilizing open-source tools. One such open-source tool will be MOOSE, an advanced finite element analysis tool developed at INL. The conversion tool will also branch out from typical commercial building designs and will aim to incorporate nuclear construction. The aim will be to convert both structural and non-structural components of nuclear facilities, such as curved concrete containment structures and piping systems, respectively.

97 MATHEMATICS AND COMPUTING↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗

Siting Analysis of a Solar-Nuclear-Desalination Integrated Energy System

Nuclear power is typically deployed as a baseload generator. Increased penetration of variable renewables motivates combining nuclear and renewable technologies into Integrated Energy Systems (IES) to improve dispatchability, component synergies and, through cogeneration, address multiple markets. However, combining multiple energy resources heavily depends on the proper selection of each system’s location and design limitations. In this paper, co-siting options for IES that couple nuclear and concentrating solar power (CSP) with thermal desalination are investigated. A comprehensive siting analysis is performed that utilizes global information survey data to determine possible co-siting options for nuclear and solar thermal generation in the United States. Viable co-siting options are distributed across the Southwestern U.S., with the greatest concentration of siting options in the southern Great Plains, although siting with higher solar direct normal irradiance is possible in other states such as Arizona and New Mexico. Brackish water desalination is also attractive across the southwest U.S. due to high water stress, but for brackish water desalination reverse osmosis (an electricity driven process) is most cost- and energy-efficient, which does not require co-siting with the thermal generator. The most attractive state for nuclear and thermal desalination (which is more attractive when using seawater) is Texas, although other areas may become attractive as water stress increases over the coming decades. Co-siting of all CSP and thermal desalination is challenging as attractive CSP sites are not coastal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermomechanical analysis and modeling of a high-temperature light trapping planar cavity solar receiver

The development of durable particle-based high-temperature solar receivers is critical for advancing concentrating solar-thermal (CST) technologies to enable high-efficiency power generation and industrial process heat. Here, this study presents a computational framework to evaluate the thermomechanical performance of a proposed enclosed light-trapping planar cavity receiver designed for particle-based thermal energy systems. The receiver incorporates absorptive cavities and fluidized particle-bed channels to enhance heat capture and reduce thermal losses. Finite element analysis (FEA) is employed to assess stress, strain, and creep-fatigue behavior under concentrated solar flux using realistic thermal boundary conditions derived from coupled system models and experimental assembly parameters. The analysis investigates the influence of particle-to-wall heat transfer coefficients (HTC) ranging from 800 to 1800 W/m 2 .K on the thermomechanical response of six candidate high-temperature alloys: Alloy 740H, Alloy 282, Alloy 617, 316H, Alloy 230, and 800H. Results show that increasing HTC reduces thermal gradients, leading to lower stresses and strains and extended minimum predicted creep life. While all materials satisfy fatigue life requirements under the investigated conditions, significant differences in creep resistance are observed. Alloy 740H consistently exhibits the longest minimum predicted creep life and the most favorable durability margins, followed by Alloy 282, with the remaining materials showing reduced creep resistance under identical loading. The reported creep lives are conservative lower-bound estimates intended for comparative material evaluation. This framework highlights the critical roles of material selection and geometry optimization in improving mechanical durability and reliability of solar-thermal receivers, forming a foundation for future experimental validation and design optimization.

14 SOLAR ENERGY↗

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY↗

Energy Storage and Decarbonization Analysis for Energy Regulators: Technical Analysis for the Illinois Commerce Commission

Jurisdictions around the world are enacting and enforcing an increasing number of policies to fight climate change, leading to higher penetration of variable renewable energy (VRE) and energy storage systems (ESSs) in the power grid. One of the biggest challenges associated with this process is the evaluation of the appropriate amount of ESS required to mitigate the variability of the VREs and achieve decarbonization goals of a particular jurisdiction. This report presents methodologies developed and results obtained for determining the minimum amount of ESS required to adequately serve load in a system where fossil fueled generators are being replaced by VREs over the next two decades. This technical analysis is performed by Sandia National Laboratories for the DOE Office of Electricity Energy Storage Program in collaboration with the Illinois Commerce Commission (ICC). The Illinois MISO Zone 4 is used as a case study. Several boundary conditions are investigated in this analysis including capacity adequacy and energy adequacy to determine the quantity of ESS required for MISO Zone 4. Multiple scenarios are designed and evaluated to incorporate the impact of varying capacity values of VREs and on the resource adequacy of the system. Several retirement scenarios involving fossil-fueled assets are also considered. Based on the current plans of new additions and retirements of generating assets, the results of the technical analysis indicate that Illinois MISO Zone 4 will require a significant quantity of ESS to satisfy their electricity demand over the next two decades.

25 ENERGY STORAGE↗

Modeling and Analysis of a Thermophotovoltaic Integrated Self-Powered Furnace

This work investigates the energy efficiency and carbon reduction potential of self-powered residential building heating equipment using a thermodynamic modeling approach. An integrated thermophotovoltaic power module and residential scale furnace system (40,000 Btu/h) were modeled and studied in detail to assess the influence of different design configurations on primary energy efficiency. Operational characteristics such as total power generation, electrical efficiency, and heat recovery were examined in a self-powered system configuration. A sensitivity analysis was conducted to determine the influence of the electric grid’s carbon dioxide footprint (carbon intensity) and the cost of electricity on the environmental, as well as the economic, benefit associated with the self-powered configuration. Compared with a traditional furnace powered by an electric grid at a carbon intensity of 0.5 kg CO 2eq /kWh EL , the self-powered furnace was shown to decrease the annual carbon dioxide emissions by approximately 550 kg (~75% reduction), while also saving more than USD 200 in utility expenses, annually. Additionally, the carbon emission reduction potential of blending different concentrations of hydrogen in natural gas fuel was also studied.

14 SOLAR ENERGY↗

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN↗