Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Resolution Ozone Mapper (HROM)

Using the backscatter ultraviolet instrument (BUV) aboard NIMBUS 4 as a baseline, point scanner mechanisms and spatial multiplex scanning systems were compared on the basis of sensitivity, field of view and simplicity. This comparison included both spectral and spatial scanning and multiplexing techniques. The selected system which optimally met the performance requirements for a shuttle based instrument was a pushbroom spatial scanner using a 15 element photomultiplier tube array and a Hadamard multiplex spectral scan. The selected system was conceptually designed. This design includes ray traces of the monochromator, mechanical layouts and the electronic block diagram.

Kohr, J. R.↗

Statistical Classification of Biosignature Information using Multiple Instrument Observations

The accurate identification of biosignatures (indications of life) from data taken from remote or in situ planetary exploration is one of the most important challenges in astrobiology, the interdisciplinary field examining habitability and the potential for extraterrestrial life. This study employs machine learning algorithms to optimize the identification of biosignatures, with an emphasis on those which are agnostic to a specific biochemical basis. We exploit the wealth of terrestrial data available from biogenic and abiogenic systems to enhance efficient feature prioritization. Our dataset, pulled from public databases and laboratory recorded measurements, includes elemental abundance, isotopic fractionation, and VNIR/Raman spectra The data curation process included standardization for detection limits and ranges. Subsequent feature extraction yielded detailed inputs for machine learning, including combinations of elemental content, isotopic ratios, and parameters of spectral peaks and troughs. Feature significance was evaluated across diverse machine learning methodologies, such as k-nearest neighbors, logistic regression, Random Forest, support vector machines, and Gaussian Naïve Bayes, along with a combined voting classifier. We utilized Receiver Operating Characteristic Area Under the Curve (ROC AUC) across 2,000 50% test-train splits as a robust metric of model performance. Results revealed a promising ROC AUC of 0.853 for the combined voting classifier. Removing elemental abundance data notably reduced model accuracy (13% decrease in AUC), highlighting its critical role in biosignature detection. Several other individual data features exhibited significance within their respective data types, offering additional granularity. This research fortifies the relevance of machine learning to astrobiology, potentially enhancing life detection missions by allowing algorithmic prioritization of high-interest samples for further investigation. Future work will refine data standardization, expand the dataset to include more terrestrial systems, and incorporate convolutional neural networks for spectral feature extraction. The potential for public data sharing is also under exploration, reinforcing our commitment to collective scientific advancement.

Statistical↗

The multi-element probabilistic collocation method (ME-PCM): Error analysis and applications

Stochastic spectral methods are numerical techniques for approximating solutions to partial differential equations with random parameters. In this work, we present and examine the multi-element probabilistic collocation method (ME-PCM), which is a generalized form of the probabilistic collocation method. In the ME-PCM, the parametric space is discretized and a collocation/cubature grid is prescribed on each element. Both full and sparse tensor product grids based on Gauss and Clenshaw-Curtis quadrature rules are considered. We prove analytically and observe in numerical tests that as the parameter space mesh is refined, the convergence rate of the solution depends on the quadrature rule of each element only through its degree of exactness. In addition, the L{sup 2} error of the tensor product interpolant is examined and an adaptivity algorithm is provided. Numerical examples demonstrating adaptive ME-PCM are shown, including low-regularity problems and long-time integration. We test the ME-PCM on two-dimensional Navier-Stokes examples and a stochastic diffusion problem with various random input distributions and up to 50 dimensions. While the convergence rate of ME-PCM deteriorates in 50 dimensions, the error in the mean and variance is two orders of magnitude lower than the error obtained with the Monte Carlo method using only a small number of samples (e.g., 100). The computational cost of ME-PCM is found to be favorable when compared to the cost of other methods including stochastic Galerkin, Monte Carlo and quasi-random sequence methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contamination of argon x-ray spectra by tungsten and other elements commonly found in tokamaks

Here, emission lines which appear in the spectral ranges of ground state transitions from n> = 2 levels in He- and H-like argon ions are discussed. X-ray transitions from elements commonly found in tokamaks (tungsten, molybdenum, iron and sulphur) which radiate in the wavelength range from 3700–4000 mÅ are identified by comparison with atomic structure calculations. Individual lines from tungsten charge states in the vicinity of Zn-like W 44+ are documented, along with B-like Mo 37+ . The behaviour of line ratios as a function of electron temperature is examined, in support of the identifications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme UV spectroheliometer on the Apollo Telescope Mount

The extreme UV spectroheliometer flown on ATM observed within the 280-1340 A spectral range at seven wavelengths simultaneously, with a spatial resolution element 5 x 5 sq arcsec field of view in 5.5 min. The instrument could also obtain spectral scans over the same wavelength range with a spectral resolution of 1.6 A in 3.8 min. The instrument is described in detail with attention given to the telescope, the spectrometer, and the detection system.

Reeves, E. M.↗

Emission spectra of selected SSME elements and materials

Stennis Space Center (SSC) is pursuing the advancement of experimental techniques and theoretical developments in the field of plume spectroscopy for application to rocket development testing programs and engine health monitoring. Exhaust plume spectral data for the Space Shuttle Main Engine (SSME) are routinely acquired. The usefulness of this data depends upon qualitative and quantitative interpretation of spectral features and their correlation with the engine performance. A knowledge of the emission spectral characteristics of effluent materials in the exhaust plume is essential. A study of SSME critical components and their materials identified 30 elements and 53 materials whose engine exhaust plume spectral might be required. The most important were evaluated using SSC's Diagnostic Testbed Facility Thruster (DTFT), a 1200-lbf, liquid oxygen/gaseous hydrogen rocket engine which very nearly replicates the temperature and pressure conditions of the SSME exhaust plume in the first Mach diamond. This report presents the spectral data for the 10 most important elements and 27 most important materials which are strongly to moderately emitting in the DTFT exhaust plume. The covered spectral range is 300 to 426 nm and the spectral resolution is 0.25 nm. Spectral line identification information is provided and line interference effects are considered.

Tejwani, Gopal D.↗

MOLYBDENUM, RUTHENIUM, AND THE HEAVY r-PROCESS ELEMENTS IN MODERATELY METAL-POOR MAIN-SEQUENCE TURNOFF STARS

The ratios of elemental abundances observed in metal-poor stars of the Galactic halo provide a unique present-day record of the nucleosynthesis products of its earliest stars. While the heaviest elements were synthesized by the r- and s-processes, dominant production mechanisms of light trans-ironic elements were obscure until recently. This work investigates further our 2011 conclusion that the low-entropy regime of a high-entropy wind (HEW) produced molybdenum and ruthenium in two moderately metal-poor turnoff stars that showed extreme overabundances of those elements with respect to iron. Only a few, rare nucleosynthesis events may have been involved. Here we determine abundances for Mo, Ru, and other trans-Fe elements for 28 similar stars by matching spectral calculations to well-exposed near-UV Keck HIRES spectra obtained for beryllium abundances. In each of the 26 turnoff stars with Mo or Ru line detections and no evidence for s-process production (therefore old), we find Mo and Ru to be three to six times overabundant. In contrast, the maximum overabundance is reduced to factors of three and two for the neighboring elements zirconium and palladium. Since the overproduction peaks sharply at Mo and Ru, a low-entropy HEW is confirmed as its origin. The overabundance level of the heavy r-process elements varies significantly, from none to a factor of four, but is uncorrelated with Mo and Ru overabundances. Despite their moderate metallicity, stars in this group trace the products of different nucleosynthetic events: possibly very few events, possibly events whose output depended on environment, metallicity, or time.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient 2-μm laser oscillation of 5% Tm{sup 3+} : KLu(WO{sub 4}){sub 2} disks and 5% Tm{sup 3+} : KLu(WO{sub 4}){sub 2}/KLu(WO{sub 4}){sub 2} composite structures

The spectral and lasing characteristics of active disk elements made of double potassium – lutetium tungstates 5% Tm : KLuW and 5% Tm : KLuW/KLuW composite structures are comparatively studied. Laser power of about 5 W in the cw regime at a wavelength of 1.85 μm was achieved in a composite sample with the active layer thickness of 250 μm. Under quasi-cw pumping, the slope efficiency of all the studied samples exceeded 50%. It is experimentally shown that the internal stresses in the composite structures strongly affect the spectral characteristics of the laser radiation. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring 14 Elemental Abundances with R = 1800 LAMOST Spectra

The LAMOST survey has acquired low-resolution spectra (R = 1800) for 5 million stars across the Milky Way, far more than any current stellar survey at a corresponding or higher spectral resolution. It is often assumed that only very few elemental abundances can be measured from such low-resolution spectra, limiting their utility for Galactic archaeology studies. However, Ting et al. used ab initio models to argue that low-resolution spectra should enable precision measurements of many elemental abundances, at least in theory. Here, we verify this claim in practice by measuring the relative abundances of 14 elements from LAMOST spectra with a precision of ≲0.1 dex for objects with S/N{sub LAMOST}≳30 (per pixel). We employ a spectral modeling method in which a data-driven model is combined with priors that the model gradient spectra should resemble ab initio spectral models. This approach assures that the data-driven abundance determinations draw on physically sensible features in the spectrum in their predictions and do not just exploit astrophysical correlations among abundances. Our analysis is constrained to the number of elemental abundances measured in the APOGEE survey, which is the source of the training labels. Obtaining high quality/resolution spectra for a subset of LAMOST stars to measure more elemental abundances as training labels and then applying this method to the full LAMOST catalog will provide a sample with more than 20 elemental abundances, which is an order of magnitude larger than current high-resolution surveys, substantially increasing the sample size for Galactic archaeology.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral methods for the Euler equations

Spectral methods for compressible flows are introduced in relation to finite difference and finite element techniques within the framework of the method of weighted residuals. Current spectral collocation methods are put in historical context. The basic concepts of both Fourier and Chebyshev spectral collocation methods are provided. Filtering strategies for both shock-fitting and shock-capturing approaches are also presented. Fourier shock capturing techniques are evaluated using a one-dimensional, periodic astrophysical 'nozzle' problem. Examples of shock-fitting approaches include a shock/acoustic wave interaction, shock/vortex interaction, and the classical blunt body problem. While the shock capturing spectral method does not yet show a clear advantage over second-order finite differences, equivalent accuracy can be obtained using shock fitting with far fewer grid points.

Hussaini, M. Y.↗

Spectral methods for the Euler equations: Fourier methods and shock-capturing

Spectral methods for compressible flows are introduced in relation to finite difference and finite element techniques within the framework of the method of weighted residuals. Current spectral collocation methods are put in historical context. The basic concepts of Fourier spectral collocation methods are provided. Filtering strategies for shock-capturing approaches are also presented. Fourier shock capturing techniques are evaluated using a one dimensional, periodic astrophysical ""nozzle'' problem.

Hussaini, M. Y.↗

Spectral methods for the Euler equations. I - Fourier methods and shock capturing

Spectral methods for compressible flows are introduced in relation to finite difference and finite element techniques within the framework of the method of weighted residuals. Current spectral collociation methods are put into historical context. The basic concepts of Fourier spectral collocation methods are provided. Filtering strategies for shock-capturing approaches are also presented. Fourier shock-capturing techniques are evaluated using a one-dimensional, periodic astrophysical 'nozzle' problem.

Hussaini, M. Y.↗

Calculation of the Refractive Indices of M{sub 1-x}R{sub x}F{sub 2+x} Crystals (M = Ca, Sr, Ba, Cd, Pb; R are Rare Earth Elements)

It is shown that the refractive indices of two-component M{sub 1-x}R{sub x}F{sub 2+x} crystals (M = Ca, Sr, Ba, Cd, Pb; R = La-Lu, Y; 0 {<=} x {<=} 0.5) can be calculated with a rather high accuracy in a wide spectral range (depending on the rare-earth-element content) using molecular refraction additivity for the components.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Pressure Sensing and Dynamics Using High Speed Fiber Bragg Grating Interrogation Systems

Fiber Bragg gratings (FBGs) are developing into useful sensing tools for measuring high pressure dynamics in extreme environments under shock loading conditions. Approaches using traditional diode array coupled FBG interrogation systems are often limited to readout speeds in the sub-MHz range. For shock wave physics, required detection speeds approaching 100 MHz are desired. We explore the use of two types of FBG sensing systems that are aimed at applying this technology as embedded high pressure probes for transient shock events. Both approaches measure time resolved spectral shifts in the return light from short (few mm long) uniform FBGs at 1550 nm. In the first approach, we use a fiber coupled spectrometer to demultiplex spectral channels into an array (up to 12) of single element InGaAs photoreceivers. By monitoring the detectors during a shock impact event with high speed recording, we are able to track the pressure induced spectral shifting in FBG down to a time resolution of 20 ns. In the second approach, developed at the Special Technologies Lab, a coherent mode-locked fiber laser is used to illuminate the FBG sensor. After the sensor, wavelength-to-time mapping is accomplished with a chromatic dispersive element, and entire spectra are sampled using a single detector at the modelocked laser repetition rate of 50 MHz. By sampling with a 12 GHz InGaAs detector, direct wavelength mapping in time is recorded, and the pressure induced FBG spectral shift is sampled at 50 MHz. Here, the sensing systems are used to monitor the spectral shifts of FBGs that are immersed into liquid water and shock compressed using explosives. In this configuration, the gratings survive to pressures approaching 50 kbar. We describe both approaches and present the measured spectral shifts from the shock experiments.

fiber Bragg grating sensors, shockwave diagnostics↗

New Solar Irradiance Measurements from the Miniature X-Ray Solar Spectrometer Cubesat

The goal of the Miniature X-ray Solar Spectrometer ( MinXSS ) CubeSat is to explore the energy distribution of soft X-ray (SXR) emissions from the quiescent Sun, active regions, and during solar flares and to model the impact on Earth's ionosphere and thermosphere. The energy emitted in the SXR range (0.1–10 keV) can vary by more than a factor of 100, yet we have limited spectral measurements in the SXRs to accurately quantify the spectral dependence of this variability. The MinXSS primary science instrument is an Amptek, Inc. X123 X-ray spectrometer that has an energy range of 0.5–30 keV with a nominal 0.15 keV energy resolution. Two flight models have been built. The first, MinXSS -1, has been making science observations since 2016 June 9 and has observed numerous flares, including more than 40 C-class and 7 M-class flares. These SXR spectral measurements have advantages over broadband SXR observations, such as providing the capability to derive multiple-temperature components and elemental abundances of coronal plasma, improved irradiance accuracy, and higher resolution spectral irradiance as input to planetary ionosphere simulations. MinXSS spectra obtained during the M5.0 flare on 2016 July 23 highlight these advantages and indicate how the elemental abundance appears to change from primarily coronal to more photospheric during the flare. MinXSS -1 observations are compared to the Geostationary Operational Environmental Satellite ( GOES ) X-ray Sensor (XRS) measurements of SXR irradiance and estimated corona temperature. Additionally, a suggested improvement to the calibration of the GOES XRS data is presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Exact modeling of lineshape and wavenumber variations for off-axis detectors in Fourier transform spectrometers (FTS) sensor systems

The utilization of detector arrays in the focal planes of FTS sensor systems allows simultaneous spectral and spatial measurements. However, spectral lineshapes and wavenumber locations depend upon the size and location of the detector elements with respect to the Haidinger fringe pattern of the FTS sensor. These spectral distortions can be generalized as a shift and shape change of the FTS sensor lineshape. Depending on the distortions that can be tolerated, a degree of field-widening can be obtained for a given Haidinger fringe pattern. An exact model for predicting the FTS lineshape distortions is presented. The model is applied to several contemporary applications in order to quantify the magnitude of distortions to be expected.

Niple, E.↗

Recent developments in monolithic phase-locked semiconductor laser arrays

Coherent combination of the power of several semiconductor lasers fabricated on the same substrate has been the subject of an intense research effort in recent years, the main motivation being to obtain higher power levels than those available from a single laser in a stable radiation pattern. Best results reported so far include 2.6 Watts CW emitted power and less than 1 deg far-field angle (in the array plane) in arrays where all the lasers are electrically connected in parallel. A different type of coherent array, where each element has a separate contact, has been recently demonstrated. While requiring the more complex two-level metallization technology, applying a separate contact to each laser provides an additional degree of freedom in the design and the operation of monolithic arrays. The separate contacts can be employed to tailor the near-field and far-field distributions and to compensate for device-to-device nonuniformities. Furthermore, the control of the currents of the array elements allows the performance of a variety of other functions, such as beam scanning, spectral mode control, wavelength tuning and control of the mutual coherence between array elements.

Katz, J.↗