Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “single cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

QUENCH DETECTION IN A SUPERCONDUCTING RADIO FREQUENCY CAVITY WITH COMBINED TEMPERATURE AND MAGNETIC FIELD MAPPING

Local dissipation of RF power in superconducting radio frequency cavities create so called "hot-spots", primary precursors of cavity quench driven by either thermal or magnetic instability. These hot-spots are detected by a temperature mapping system, and a large increase in temperature on the outer surface is detected during cavity quench events. Here, we have used combined magnetic and temperature mapping systems using anisotropic magneto-resistance (AMR) sensors and carbon resisters to locate the hot spots and areas with high trapped flux on a 3.0 GHz single-cell Nb cavity during the RF tests at 2.0 K. The quench location and hot spots were detected near the equator when the residual magnetic field in the Dewar is kept < 1 mG. The hot spots and quench locations moved when the magnetic field is trapped locally, as detected by T-mapping system. No significant dynamics of trapped flux is detected by AMR sensors, however change in magnetic flux during cavity quench is detected by a flux gate magnetometer, close to the quench location. The result provide the direct evidence of hot spots and quench events due to localized trapped vortices.

Ciovati, Gianluigi↗

ON THE WAY TO A 10MEV, CONDUCTION-COOLED COMPACT SRF ACCELERATOR

After the success of designing a compact 1MeV, 1MW accelerator based on conduction-cooled SRF, Jefferson Lab is now pursuing a concept to provide a tenfold increase of the beam energy. The obvious challenge for SRF is to move from a single-cell to a multicell cavity while maintaining high efficiency and the ability to operate the machine without a complex cryogenic plant. This paper summarizes the current state of this effort with respect to the design of a Nb3Sn coated five-cell cavity and the corresponding RF components, especially the fundamental power coupler (FPC), as well as first thermal analysis of the cryocooler-based cooling setup.

Ciovati, G.↗

Developing Conduction-Cooled SRF Cavities and First Test Results [Slides]

Summary and Future Work: Development of conduction cooling for SRF; practical thermal link design; experimental setup ready; first results are promising; 6.6 MV/m cwrecorded on a single cell 650 MHz Nb3Sn cavity Activities: ongoing and planned; improve magnetic hygiene of our cryostat; test with improved Nb3Sn coating; and identity and mitigate potential microphonics due to cryocooler vibrations.

43 PARTICLE ACCELERATORS↗

Scale-Up of Electrode Coating and Flow-Field for Commercial Hydrogen Peroxide Electrolyzer: Cooperative Research and Development Final Report, CRADA Number CRD-17-00687

Hydrogen peroxide is currently produced at central chemical plants via the anthraquinone oxidation process. This process produces environmental pollutants that are costly to remediate, requires hazardous long distance shipping of highly concentrated peroxide (50% or 70%), and necessitates extra handling costs related to storage and dilution. Peroxygen Systems, Inc. (PSi) is developing breakthrough technology for on-site hydrogen peroxide production. PSi’s on-site on-demand electrolyzer can reduce the cost of producing hydrogen peroxide by 50%, while also completely eliminating the cost and safety issues associated with shipping and handling of high concentration hydrogen peroxide. The challenge for PSi is scaling. To support the next step toward commercialization (customer pilot tests), scaling the prototype into larger single cells and 20-40 cell stacks is required. In addition to internal hardware and flow-field design efforts at PSi, NREL will address three critical problems for this scale-up effort: (1) demonstrating a large scale roll-to-roll (R2R) process to coat uniform electrode materials for 100 cm2 and 500 cm2 stack testing, (2) demonstrating an in-line diagnostic to achieve better electrode quality control, and (3) performing in situ cell/stack testing to better understand and optimize the performance of the flow field design.

28 EE - Advanced Manufacturing Office (EE-5A)↗

High power coupler development for EIC

The synchrotron radiation loss in EIC Electron Storage Ring is as high as up to 10 MW. This energy loss will be compensated by 17 2K 591 MHz single-cell SRF cavities with a combined total of 34 high power fundamental power couplers. Each power coupler will operate 92% of revolution time CW and ~8% of revolution time with 400 kW forward power due to the beam abort gap. To satisfy the EIC needs, we developed two 500 kW standing-wave FPC designs at BNL based on either a BeO and an Al 2 O 3 RF window. This paper will briefly summarize test results of the BeO window FPC , and describe the design development of the Al 2 O 3 window based FPC.

43 PARTICLE ACCELERATORS↗

Efficient and low-cost hydrogen production by wind power driven water electrolysis

The document describes and discusses the results of a techno-economic analysis for wind driven electrolysis systems. The costs obtained for different plants, including onshore and offshore locations and different plant sizes, are discussed. Large scale wind electrolysis plants show high potential to achieve the target of 2 $/kg. Initial results of experimental tests for a single cell electrolyzer, to be coupled directly with a wind turbine, are also presented and discussed.

08 HYDROGEN↗

ENIGMA: Ecosystems and Networks Integrated with Genes and Molecular Assemblies. Final Report

ENIGMA research is performed at a very large scale involving collaborations between multiple research groups to address two major driving concepts: For any microbe, it is possible to discover efficiently the genetic determinants of adaptation to life in dynamic environments in contact with other living members of its ecology and reveal hidden functional phenomena that are only possible by using a systems biology approach; and for any environment, it is possible to predict the temporal changes in geochemistry and accompanying system behavior, for some length of time, given biogeochemical and physical inputs. These driving concepts also map directly to grand challenges the ENIGMA team has outlined: “Define the levels of biological organization most relevant to scaling from single cells to ecosystems and global cycles; capture how that organization varies in time and space; and identify critical interactions that dictate rates of carbon, nutrient, and energy transformation in different environments.”

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of duration of 120 oC baking on the performance on superconducting radio frequency niobium cavities

Over the last decade much attention was given in increasing the quality factor of superconducting radio frequency (SRF) cavities by impurity doping. Prior to the era of doping, the final cavity processing technique to achieve the high accelerating gradient includes the ?in situ? low temperature baking of SRF cavities at temperature ~ 120 oC for several hours. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low temperature baking at 120 oC up to 96 hours. The experimental data were analyzed with available theory of superconductivity to elucidate the effect of the duration of low temperature baking on the superconducting properties of cavity materials as well as the rf performance. In addition, the rf loss related to the trapping of residual magnetic field refereed as flux trapping sensitivity was measured with respect to the duration of 120 oC bake.

Khanal, B. D.↗

Effect of Low Temperature Nitrogen Baking on Superconducting Radio Frequency Cavities With Different Frequency

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Forged Ingot Niobium Technology for Accelerator Applications and Scientific Frontiers

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Surface properties and RF performance of Vapor Diffused Nb3Sn on Nb after sequential anneals below 1000 °C

Nb3Sn is a next-generation superconducting material that can be used for future superconducting radiofrequency (SRF) accelerator cavities, promising better performance, cost reduction, and higher operating temperature than Nb. The Sn vapor diffusion method is currently the most preferred and successful technique to coat niobium cavi-ties with Nb3Sn. Among post-coating treatments to opti-mize the coating quality, higher temperature annealing without Sn is known to degrade Nb3Sn because of Sn loss. We have investigated Nb3Sn/Nb samples briefly annealed at 800-1000 °C for 10 and 20 minutes to poten-tially improve the surface to enhance the performance of Nb3Sn-coated cavities. Following the sample studies, a coated single-cell cavity was sequentially annealed at 900 °C and tested its performance each time, improving the cavity's quality factor relatively. This paper summarizes the sample studies and discusses the RF test results from sequentially annealed SRF Nb3Sn/Nb cavity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Materials Science of the Interstitial Doping Process

Particle accelerators are an increasingly important tool for frontier science. Growing initial and operating costs are a significant barrier for upgrades and for new machines. While everything matters, the major cost contributor is the SRF cavities and their ancillary facilities (e.g., cryoplant). Accordingly, the accelerator science community devotes much R&D effort to improving their energy efficiency (increased Q o ) and gradient (E acc ). While improved gradient is at the forefront for certain machines (ILC), improved quality factor has broader impact, benefitting all SRF applications. An important opportunity for accelerator science and technology to move forward arose in the course of building the LCLS-II, the second generation Linac Coherent Light Source at SLAC. At more or less the same time, researchers at Fermilab discovered that introducing a small amount of nitrogen to the niobium surface could improve the mid-range quality factor as much as three-fold. A firm resolution of how nitrogen confers its benefit attracts much current research interest. The key elements of the “nitrogen doping” process were vacuum bake at 800 °C, brief exposure to mTorr of nitrogen at several hundred degrees followed by electropolish (EP) to remove several microns from the surface to eliminate unwanted nitrides: While the process as a whole was novel, the comprising unit operations are familiar to the accelerator community. It was judged reasonable to adopt it as a cost-reduction technology for LCLS-II. Researchers carried out a program of varying process parameters and measuring performance in single-cell cavities, leading to a consensus stable protocol for the project. The transition to vendor fabrication and multiple niobium sources has presented unforeseen challenges of performance variation evidently not connected to anything that could be incorporated in a purchase specification. Moving beyond the high temperature N-doping process above, researchers reported a simplified process consisting entirely of tens of hours anneal in a N atmosphere at low temperatures (~120°C – 160°C) after 800 °C UHV bake. These processes typically yield a few-nm doped layer while the high temperature process yields at least a few to many micron doped layer. Even more recently, oxygen has been used to dope instead of nitrogen which leaves a few-µm O-alloyed layer upon vacuum annealing for 300 °C for ~3 hours. The investigation of these materials is just beginning, but the process simplification they may offer is surely attractive. The very low quantity of material that appears to be significant in the “infusion” process indicates the need for very careful control of gas species available for diffusion into the surface during low temperature treatment, both for process control and research to characterize the underlying dynamics. Oxygen alloying offers the further opportunity to utilize the decomposition of the surface native oxide as the dopant source. It is necessary to understand and (thus) manage this process. We have been supported by the Department of Energy Offices of High Energy Physics and Nuclear Physics to pursue this goal.

36 MATERIALS SCIENCE↗

Advances in SRF qubit architectures for quantum computing

Superconducting radio frequency (SRF) cavities provide an excellent platform for storing quantum information as quantum d-level systems (qudits) due to their exceptionally long lifetimes and large accessible Hilbert spaces. A common strategy to manipulate the states is to use a nonlinear element like a transmon. There are, however, several challenges to building a 3D SRF architecture while maintaining a long cavity lifetime. We demonstrate our successful integration of transmons with single-cell Nb SRF cavities and the ability to prepare several non-classical states. Finally, we discuss our strategies to improve the coherence times, gate schemes, and extend the system for building a multi-qudit quantum processor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗

Understanding the field and frequency dependence of rf loss in SRF cavities

SRF cavities subjected to heat treatment below 200 °C in the presence of nitrogen showed an improvement in quality factor while maintaining an accelerating gradient above 25 MV/m. Here, we report the rf performance of several single-cell superconducting radio frequency cavities with frequency ranging from 0.75 - 3.0 GHz subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 - 175 oC for 24 - 48 hours in low partial pressure of ultra-pure nitrogen gas. The improvement in Q? with Q-rise was observed when nitrogen gas was injected ~300 °C during the furnace treatment. The surface modification was confirmed by the change in electronic mean free path and near surface elemental analysis by SIMS. The field dependence of the rf losses is strongly correlated to the cavity frequency. The analysis of experimental data with available theoretical models as well as comparison with similar study on high temperature nitrogen doped cavities will be presented.

Ciovati, Gianluigi↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

Advances in SRF cavity architectures for quantum computing

Superconducting radio frequency (SRF) cavities offer an excellent platform for storing and processing quantum information due to their exceptionally long lifetimes and large accessible Hilbert spaces. A common strategy to manipulate the quantum states is to use a nonlinear element like a transmon. Nevertheless, constructing a 3D SRF architecture with sustained cavity lifetimes presents several challenges. In this talk, we present our successful integration of transmons with single-cell Nb SRF cavities, enabling the preparation of several non-classical states. Preliminary results reveal the potential of this platform to build a qudit-based quantum computer, departing from traditional qubit-based architectures. We discuss strategies to enhance coherence times, develop high-fidelity gate schemes, and expand the system for constructing a multi-qudit quantum processor. Furthermore, we explore how this architecture can bolster dark matter detection efficiency through multi-photon quantum state preparation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Power Test Results For A Cylindrical-Shell SiC Higher-Order-Mode DAMPER

The next high-current Electron Ion Collider (EIC) is a new accelerator to be built at Brookhaven National Laboratory (BNL) in collaboration with Thomas Jefferson National Accelerator Facility (TJNAF). In the EIC Electron Storage Ring (ESR), there will be beam currents up to 2.5 A, which will excite massive Higher-Order-Modes (HOM) power in the 17 single-cell 591 MHz Superconducting Radio Frequency (SRF) cavities. To damp the HOM power in the ESR SRF cavities is a challenge. A room temperature cylindrical shell shape Silicon Carbide (SiC) Beamline HOM Absorber (BLA) was chosen as the baseline design, due to its broadband and high-power capability, and previous demonstrations at other accelerator facilities, albeit at much lower power. Because the EIC BLA HOM power dissipation is significantly greater than the previous applications, it is imperative to carry out high power testing to determine the maximum device performance levels achievable for thermal transport, RF breakdown, and mechanical stress, prior to finalizing the design. A SiC HOM absorber with state-of-the-art geometry size was prototyped to verify shrink-fit technique, test outgassing rate, and high power handling capability. This paper presents the HOM damper’s prototyping and test results.

43 PARTICLE ACCELERATORS↗