Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “silver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Destructive PIE and Safety Testing of Six AGR-5/6/7 Capsule 2 Compacts

This study evaluates fission product retention and particle failure mechanisms in AGR-5/6/7 Capsule 2 uranium carbide and uranium oxide (UCO) tristructural isotropic (TRISO) fuel under high-temperature gas reactor accident-relevant conditions using high-temperature safety tests and destructive postirradiation examination. Three Capsule 2 compacts were held isothermally at 1600°C for approximately 300 hours and one compact at 1800°C for approximately 300 hours; two additional compacts were examined in the as-irradiated state. Post-test deconsolidation–leach–burn–leach (DLBL) quantified nuclide inventories in matrix and particles. Individual particles were surveyed for radioisotope inventories, and microanalytical approaches resolved microstructural evolution and fission product distributions within the coating layers. At 1600°C, no krypton was detected above the minimum detectable limit, and cesium releases were far below a single particle equivalent, indicating the absence of full TRISO failure or SiC failures. Silver releases were limited and primarily reflected depleted postirradiation inventories, consistent with prior compact-level exams indicating substantial in-pile 110mAg loss. At 1800°C, cumulative 134Cs release of approximately 2.5 particle equivalents and delayed 85Kr totaling approximately 0.53 particle equivalents were consistent with one full TRISO failure and two SiC failures. Europium and strontium releases were roughly one order of magnitude higher than at 1600°C and comparable to AGR-1/AGR-2 high-temperature tests, with sustained late-hold rates indicating diffusion through intact coatings coupled with matrix depletion. Overall, AGR-5/6/7 Capsule 2 UCO fuel demonstrated fission product retention during safety testing consistent with prior AGR campaigns, while distinctive in-pile 110mAg depletion and measurable 1600°C europium loss motivate targeted follow-on studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Front Side Copper Metallization Paste for Silicon Solar Cells (CRADA Final Report)

Adoption and testing of copper (Cu) metallization pastes on existing research and development (R&D) or production lines is hindered by the perceived idea that Cu will contaminate the equipment. The objective of this work is to prove if Cu from the pastes will contaminate and degrade the silver metallized cells being produced in the same firing furnace.

14 SOLAR ENERGY↗

Destructive PIE and Safety Testing of Six AGR-5/6/7 Capsule 2 Compacts

This study evaluates fission product retention and particle failure mechanisms in AGR-5/6/7 Capsule 2 uranium carbide and uranium oxide (UCO) tristructural isotropic (TRISO) fuel under high-temperature gas reactor accident-relevant conditions using high-temperature safety tests and destructive post-irradiation examination. Three Capsule 2 compacts were held isothermally at 1600°C for approximately 300 hours and one compact at 1800°C for approximately 300 hours; two additional compacts were examined in the as-irradiated state. Post-test deconsolidation–leach–burn–leach (DLBL) quantified nuclide inventories in matrix and particles. Individual particles were surveyed for radioisotope inventories, and microanalytical approaches resolved microstructural evolution and fission product distributions within the coating layers. At 1600°C, no krypton was detected above the minimum detectable limit, and cesium releases were far below a single particle equivalent, indicating the absence of full TRISO failure or SiC failures. Silver releases were limited and primarily reflected depleted post-irradiation inventories, consistent with prior compact-level exams indicating substantial in-pile 110m Ag loss. At 1800°C, cumulative 134 Cs release of approximately 2.5 particle equivalents and delayed 85 Kr totaling approximately 0.53 particle equivalents were consistent with one full TRISO failure and two SiC failures. Europium and strontium releases were roughly one order of magnitude higher than at 1600°C and comparable to AGR-1/AGR-2 high-temperature tests, with sustained late-hold rates indicating diffusion through intact coatings coupled with matrix depletion. Overall, AGR-5/6/7 Capsule 2 UCO fuel demonstrated fission product retention during safety testing consistent with prior AGR campaigns, while distinctive in-pile 110m Ag depletion and measurable 1600°C europium loss motivate targeted follow-on studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bismuth-Functionalized Silica Aerogels for Iodine Capture

The U.S. Department of Energy is looking into alternative sorbents for the removal of radioiodine from off-gas streams in a used nuclear fuel reprocessing plant. One class of sorbents considered are bismuth-functionalized silica aerogels which offer an efficient capture of iodine from off-gas streams and are environmentally friendly and lower cost when compared to silver-functionalized sorbents. Two types of bismuth-functionalized silica aerogels were successfully manufactured using a hierarchical synthesis approach:1) The Bi 3+ -aerogel with bismuth oxide nitrate hydroxide hydrate particles and 2) Bi-aerogel with bismuth metal and bismuth sulfide nanoparticles. Both sorbents exhibited high sorption capacity for iodine. However, presence of particles of different composition, size, and distribution on aerogel support resulted in different iodine loadings. The Bi 3+ -aerogel exhibited sorption capacity of 289 mg/g. In contrast, Bi-aerogel exhibited more that 20% higher sorption capacity. The heat-treatment of Bi 3+ -aerogel at 225? under hydrogen atmosphere increased iodine loading capacity to 351 mg/g.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Updating and Refining BISON TRISO Assessment

Several advanced reactor concepts consider tristructural isotropic (TRISO) fuel in their designs. To support the advanced reactor industry, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program within the U.S. Department of Energy (DOE) is developing modeling and simulation capabilities within the BISON fuel performance code. Assessment of these capabilities against available experi- mental data, such as the Advanced Gas Reactor (AGR) program, is essential in instilling confidence in the code predictions. Associated uncertainties in model inadequacy, experimental measurements, and manufacturing are also of importance. This report discusses the updating and standardization of the existing assessment suite in BISON for TRISO fuel performance analysis. The cases considered the AGR-1, AGR-2, and AGR-3/4 experimental programs. The report also includes a preliminary investigation into the sources of model inadequacy associated with silver (Ag) release fractions using the AGR-2 Compact 2-1-2 as a case study. The results indicate that uncertainties in the operating temperatures supplied to the model and the form of those temperature conditions (spatially averaged versus spatially resolved) both affect Ag release predictions. This suggests that previously observed model inadequacy can be attributed to both physical models and the operating conditions supplied to them. These findings will be leveraged to guide development of assessment cases for additional experiments and refinement of physical models for behaviors that potentially influence Ag release, such as palladium penetration.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out [Slides]

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Krypton Concentration using HZ-PAN

Idaho National Laboratory (INL) has developed and tested engineered sorbents to separate and capture volatile fission products such iodine, xenon (Xe), and krypton (Kr) from off-gas streams. As noble gases, Xe and Kr can be difficult to capture and separate. Historically, cryogenic distillation has been used to execute the separation. However, performing this separation from bulk air streams is expensive and can pose significant hazards. INL has successfully developed two different sorbents for Xe and Kr capture, silver mordenite polyacrylonitrile and hydrogen mordenite polyacrylonitrile (HZ-PAN). Adsorption studies to date successfully separated and captured Kr from carrier gas streams, but those studies focused primarily on initial separation and capture. Successful utilization in a used nuclear fuel (UNF) reprocessing facility, however, requires further concentration of the Kr to minimize long term storage volumes. This study focuses on the concentration of Kr utilizing HZ PAN as the concentrating media. Concentrating Kr during desorption is ideal for two reasons: one, to produce Kr that can be used for commercial and research applications, or two, to minimize the volume of the radioactive gaseous waste stream for disposal. This report investigates the Kr concentrating potential of HZ-PAN by running multiple Kr adsorption-desorption cycles, collecting the desorbed effluent from a saturated HZ-PAN column, and loading it onto a fresh column. This study demonstrates that four adsorption-desorption cycles can transform a 150 ppmv Kr stream into a 37.5% Kr stream, an overall concentration factor of 2497. Each concentration step results in successively smaller volumes desorbed, reducing volume by a factor of approximately 40,000. Depending on the operational goals, during desorption one could collect smaller volume fractions of high concentration Kr (~ 67%). This demonstration should be considered proof-of-concept. Further refinement is necessary to develop optimum operating schemes to integrate into UNF off-gas treatment.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Development of in-situ polymerized intrinsically conductive resin and low-cost carbon pigments offering high conductivity for sensing, EMI shielding and lighting protection

Electrically conductive composites are emerging across diverse industries such as electronic, automotive, aerospace, advanced air mobility, biomedical, infrastructure, defense and security offering static charge dissipation, electromagnetic interference shielding, lighting protection, sensing, dicing, corrosion monitoring, etc. Conductivity enhanced composites provide several advantages compared to conventional metals including weight reduction, corrosion resistance, energy efficient processability, tunable properties and multifunctionality. Polymers are typically insulating in nature and require conducting filler for electron transport. However, dispersion and polymer-filler interphases are critical and often disrupt conducting pathways. Besides, conductive fillers such as graphene, carbon nanotube, MXene, silver nanowire, etc. are expensive, limiting their wide adoption in composite industry. On the other hand, a limited number of intrinsically conductive polymers are available among which polyaniline (PANI) has been widely studied due to its high conductivity, thermal and chemical stability. However, PANI is difficult to process and exhibits weak mechanical properties. In brief, there is a significant demand for electrically conductive polymer formulation with cost-effective conducting fillers that offer processability in scale to expand the market of conductivity enhanced materials.

Kumar, Vipin [Oak Ridge National Laboratory (ORNL)↗

Quality and Loss Factor Analysis of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons in a magnetic field, which produces extremely small signals requiring low-loss cryogenic transmission lines for readout to reduce noise and attenuation. Yttrium Barium Copper Oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss superconducting cables such as Niobium (Nb) and Niobium Titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We evaluate their suitability by characterizing the quality and loss factors of five stripline resonators (three YBCO, and copper and silver references) from the Brookhaven Technology Group at 77 K without an external field, and cooled to 30 mK in a 14 T magnet. For measurements at 77 K we recorded scattering parameter data and employed Lorentzian and circle-fitting analysis techniques. We identified the best-performing resonator and developed a cryogenic probe for future testing in the magnet at millikelvin temperatures.

Marinos, Zoe [UCLA]↗

Electrochemical testing of metals for petroleum wastewater monitoring

The purpose of this project was to determine the feasibility of ion-selective electrode (ISE) as compared to x-ray fluorescence (XRF) for determining the concentrations of metal ions in petroleum wastewater. ISEs for silver and cadmium were tested in a laboratory under increasingly realistic conditions, then deployed in the sewer wastewater monitoring complex to simulate a petroleum wastewater system. By verifying the ISE calibration after wastewater exposure and comparing its measurements to the XRF systems within the wastewater monitoring system, we determined that the ISE is more sensitive but less feasible for use in live wastewater monitoring due to fouling concerns.

Energy - Petroleum↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Investigation of Nucleation and Growth at a Liquid–Liquid Interface by Solvent Exchange and Synchrotron Small-Angle X-Ray Scattering

Hybrid nanomaterials possess complex architectures that are driven by a self-assembly process between an inorganic element and an organic ligand. The properties of these materials can often be tuned by organic ligand variation, or by swapping the inorganic element. This enables the flexible fabrication of tailored hybrid materials with a rich variety of properties for technological applications. Liquid-liquid interfaces are useful for synthesizing these compounds as precursors can be segregated and allowed to interact only at the interface. Although procedurally straightforward, this is a complex reaction in an environment that is not easy to probe. Here, we explore the interfacial crystallization of mithrene, a supramolecular multi-quantum well. This material sandwiches a well-defined silver-chalcogenide layer between layers of organic ligands. Controlling mithrene crystal size and morphology to be useful for applications requires understanding details of its crystal growth, but the specific mechanism for this reaction remain only lightly investigated. We performed a study of mithrene crystallization at an oil-water interfaces to elucidate how the interfacial free energy affects nucleation and growth. We exchanged the oil solvent on the basis of solvent viscosity and surface tension, modifying the dynamic contact angle and interfacial free energy. We isolated and characterized the reaction byproducts via scanning electron microscopy (SEM). We also developed a high-throughput small angle X-ray scattering (SAXS) technique to measure crystallization at short reaction timescales (minutes). Our results showed that modifying interfacial surface energy affects both the reaction kinetics and product size homogeneity and yield. Our SAXS measurements reveal the onset of crystallinity after only 15 min. These results provide a template for exploring directed synthesis of complex materials via experimental methods.

Schriber, Elyse A.↗

Standard Operating Protocol for Ion-Exchange Capacity of Anion Exchange Membranes

Ion-exchange capacity (IEC) is the measure of a material’s capability to displace ions formerly incorporated within its structure. IEC is a key feature of anion-exchange membranes (AEM), as it determines the AEM’s ability to conduct the ions required to sustain the electrochemical reactions where they are utilized. As an intrinsic property, measuring the IEC accurately is essential to study AEMs and understand their performance within devices. In this method article, a facile and accurate standard operating procedure (SOP) to measure the IEC of AEMs is proposed. When compared to conventional acid-base back-titration or Mohr titration, the proposed method combines the fast reaction between silver and halide ions and the accuracy of the potentiometric titration, providing a convenient and precise protocol for researchers in the field.

42 ENGINEERING↗

A computational modeling framework for pre-clinical evaluation of cardiac mapping systems

There are a variety of difficulties in evaluating clinical cardiac mapping systems, most notably the inability to record the transmembrane potential throughout the entire heart during patient procedures which prevents the comparison to a relevant “gold standard”. Cardiac mapping systems are comprised of hardware and software elements including sophisticated mathematical algorithms, both of which continue to undergo rapid innovation. The purpose of this study is to develop a computational modeling framework to evaluate the performance of cardiac mapping systems. The framework enables rigorous evaluation of a mapping system’s ability to localize and characterize (i.e., focal or reentrant) arrhythmogenic sources in the heart. The main component of our tool is a library of computer simulations of various dynamic patterns throughout the entire heart in which the type and location of the arrhythmogenic sources are known. Our framework allows for performance evaluation for various electrode configurations, heart geometries, arrhythmias, and electrogram noise levels and involves blind comparison of mapping systems against a “silver standard” comprised of computer simulations in which the precise transmembrane potential patterns throughout the heart are known. A feasibility study was performed using simulations of patterns in the human left atria and three hypothetical virtual catheter electrode arrays. Activation times (AcT) and patterns (AcP) were computed for three virtual electrode arrays: two basket arrays with good and poor contact and one high-resolution grid with uniform spacing. The average root mean squared difference of AcTs of electrograms and those of the nearest endocardial action potential was less than 1 ms and therefore appears to be a poor performance metric. In an effort to standardize performance evaluation of mapping systems a novel performance metric is introduced based on the number of AcPs identified correctly and those considered spurious as well as misclassifications of arrhythmia type; spatial and temporal localization accuracy of correctly identified patterns was also quantified. This approach provides a rigorous quantitative analysis of cardiac mapping system performance. Proof of concept of this computational evaluation framework suggests that it could help safeguard that mapping systems perform as expected as well as provide estimates of system accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Machine Learning-Enabled Wearable Piezoelectric Acoustic Sensor for Real-Time Breast Abnormality Detection

In contemporary society, breast health has become a significant public health concern, particularly among women. According to statistics from the World Health Organization, both the incidence and mortality rates of breast tumors have steadily increased in recent years. Therefore, effective early-stage screening and postoperative monitoring are essential for maintaining breast health. However, conventional clinical diagnostic modalities are typically bulky, operationally complex, and unsuitable for continuous real-time monitoring, which limits their use in portable and everyday health management applications. To address these limitations, this study proposes a machine learning-integrated wearable piezoelectric sensing platform as an auxiliary tool for breast health assessment. The device consists of a PDMS matching layer embedded with flexible silver nanowires, a P(VDF-TrFE) piezoelectric layer, and a multi-channel low-noise signal acquisition circuit. It is capable of acquiring acoustic echo signals from tissue-mimicking environments and automatically evaluating signal validity using a convolutional neural network (CNN). By integrating piezoelectric sensing with deep learning-based signal analysis, the proposed system achieves a signal-to-noise ratio exceeding 70 dB and a real-time classification accuracy above 96% under controlled conditions. These results demonstrate that the platform provides a compact, portable, and intelligent approach for wearable sensing of mechanical heterogeneity and highlight its potential for future development in continuous biomedical monitoring technologies.

He, Shuaitong↗

Linear and Nonlinear Optical Properties of Iridium Nanoparticles Grown via Atomic Layer Deposition

Nonlinear optical phenomena enable novel photonic and optoelectronic applications. Especially, metallic nanoparticles and thin films with nonlinear optical properties offer the potential for micro-optical system integration. For this purpose, new nonlinear materials need to be continuously identified, investigated, and utilized for nonlinear optical applications. While noble-metal nanoparticles, nanostructures, and thin films of silver and gold have been widely studied, iridium (Ir) nanoparticles and ultrathin films have not been investigated for nonlinear optical applications yet. Here, we present a combined theoretical and experimental study on the linear and nonlinear optical properties of iridium nanoparticles deposited via atomic layer deposition (ALD). Linear optical constants, such as the effective refractive index and extinction coefficient, were evaluated at different growth stages of nanoparticle formation. Both linear and nonlinear optical properties of these Ir ALD coatings were calculated theoretically using the Maxwell Garnett theory. The third-order susceptibility of iridium nanoparticle samples was experimentally investigated using the z-scan technique. According to the experiment, for an Ir ALD coating with 45 cycles resulting in iridium nanoparticles, the experimentally determined nonlinear third-order susceptibility is about χ Ir (3) = (2.4 – i2.1) × 10 –17 m 2 /V 2 at the fundamental wavelength of 700 nm. The theory fitted to the experimental results predicts a 5 × 10 6 -fold increase around 230 nm. This strong increase is due to the proximity to the Mie resonance of iridium nanoparticles.

36 MATERIALS SCIENCE↗

Towards Automated and High-Throughput Quantitative Sizing and Isotopic Analysis of Nanoparticles via Single Particle-ICP-TOF-MS

The work described herein assesses the ability to characterize gold nanoparticles (Au NPs) of 50 and 100 nm, as well as 60 nm silver shelled gold core nanospheres (Au/Ag NPs), for their mass, respective size, and isotopic composition in an automated and unattended fashion. Here, an innovative autosampler was employed to mix and transport the blanks, standards, and samples into a high-efficiency single particle (SP) introduction system for subsequent analysis by inductively coupled plasma–time of flight–mass spectrometry (ICP-TOF-MS). Optimized NP transport efficiency into the ICP-TOF-MS was determined to be >80%. This combination, SP-ICP-TOF-MS, allowed for high-throughput sample analysis. Specifically, 50 total samples (including blanks/standards) were analyzed over 8 h, to provide an accurate characterization of the NPs. This methodology was implemented over the course of 5 days to assess its long-term reproducibility. Impressively, the in-run and day-to-day variation of sample transport is assessed to be 3.54 and 9.52% relative standard deviation (%RSD), respectively. The determination of Au NP size and concentration was of <5% relative difference from the certified values over these time periods. Isotopic characterization of the 107 Ag/ 109 Ag particles (n = 132,630) over the course of the measurements was determined to be 1.0788 ± 0.0030 with high accuracy (0.23% relative difference) when compared to the multi-collector–ICP-MS determination.

36 MATERIALS SCIENCE↗

Tunable Work Functions in Plasmonic Metals

We have studied the effect of BITh molecules on the work functions of Ag and Au, with and without quartz lamp illumination. Silver and gold films coated with BITh molecules were fabricated and studied in reflection and Kelvin Probe experiments. The deposition of BITh films on Ag and Au reduced their work functions (in agreement with our recent study, wherein a similar reduction was caused by the deposition of a PMMA polymer). Illumination of the BITh-coated samples with a quartz lamp caused reductions in work functions by several tens of meV, which (almost) returned to their original values when the light was turned off. The characteristic time of this process (~15 min) was much shorter than that of photopolymerization (~180 min), suggesting that these two phenomena are nearly independent of each other. The effects of the Au substrates were qualitatively similar to those of the Ag substrates. Our findings pave the way to fundamental studies and applications of light–matter interactions.

BITh↗