X ray analysis of balloon-collected particles erroneously considered as an October influx into the lower stratosphere

Individual particles were analyzed on the collection screens in a Jeolco scanning electron microscope using a Kevex Li-drifted silicon energy dispersive X ray detector. It was found that the bulk of the stratospheric samples studied comes from explosive squib devices. It is pointed out that this finding does not invalidate the extensive results obtained by Bigg et al. (1970, 1971) in previous sampling experiments.

Farlow, N. H.↗

Photometric imaging of Mars during the 1973 opposition

The paper discusses imaging of Mars at 20 wavelengths in the spectral region from 0.35 to 1.10 microns performed during the 1973 opposition with a photometric imaging system that uses a silicon vidicon tube as the detector. The imaging system and data-reduction procedures are described in detail, and relative reflectance spectra for several small areas in the images are presented along with vidicon images obtained during early phases in the development of the 1973 dust storms. Several anomalous blue brightenings are examined and attributed to ground fog and H2O frost. It is suggested that anomalously large amounts of H2O were pulsed into the atmosphere from the regolith by the storm system. An apparent fading and recession of the north polar hood is noted, surface units revealed in contrast-enhanced ratio images are identified, and the need for higher-spatial-resolution orbital spectroscopy of dark areas is emphasized.

Mccord, T. B.↗

Photo sensor array technology development

The development of an improved capability photo sensor array imager for use in a Viking '75 type facsimile camera is presented. This imager consists of silicon photodiodes and lead sulfide detectors to cover a spectral range from 0.4 to 2.7 microns. An optical design specifying filter configurations and convergence angles is described. Three electronics design approaches: AC-chopped light, DC-dual detector, and DC-single detector, are investigated. Experimental and calculated results are compared whenever possible using breadboard testing and tolerance analysis techniques. Results show that any design used must be forgiving of the relative instability of lead sulfide detectors. A final design using lead sulfide detectors and associated electronics is implemented by fabrication of a hybrid prototype device. Test results of this device show a good agreement with calculated values.

Rossman, M. W.↗

Low Cost Solar Array Project: Composition Measurements by Analytical Photo Catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is discussed. A detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr is evaluated. During the first reporting period Al, Cr, Fe, and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determine initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests vapor pressure curves for these four pure substances were also mapped. Ti and Si were detected. The best lines to monitor were catalogued and vapor pressure curves were determined. Attempts to detect vanadium were unsuccessful due to the refractory nature of this element and the limited temperature range of the evaporator.

Sutton, D. G.↗

The GSFC Mark-2 three band hand-held radiometer

A self-contained, portable, hand-radiometer designed for field usage was constructed and tested. The device, consisting of a hand-held probe containing three sensors and a strap supported electronic module, weighs 4 1/2 kilograms. It is powered by flashlight and transistor radio batteries, utilizes two silicon and one lead sulfide detectors, has three liquid crystal displays, sample and hold radiometric sampling, and its spectral configuration corresponds to LANDSAT-D's thematic mapper bands. The device was designed to support thematic mapper ground-truth data collection efforts and to facilitate 'in situ' ground-based remote sensing studies of natural materials. Prototype instruments were extensively tested under laboratory and field conditions with excellent results.

Tucker, C. J.↗

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Cryogenic telescope on the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has completed an unbiased all-sky survey at wavelengths from 10 to 100 microns. The design and performance of the focal plane array is described with emphasis on in-orbit measurements of the sensitivity and stability. In the four broad spectral bands centered at 12, 25, 60, and 100 microns, the system noise equivalent flux density (NEFD) values are in Jy/(Square root of Hz), 0.03, 0.025, 0.046, and 0.21, respectively (Jansky = 10 to the -26th W/sq m/Hz). For point sources, a single scan at the survey rate of 3.8 arcmin/s yields limiting flux densities at the 3-sigma confidence level of 0.36, 0.30, 0.39, and 1.2 Jy. The dc stability of the junction field effect transistor (JFET) amplifiers and the excellent off-axis rejection of the telescope permit total flux measurements of extended infrared emission at levels below 6,000,000 Jy/sr. Response of the extrinsic silicon and germanium photo-detectors to ionizing radiation is described.

Low, F. J.↗

Method of fabricating an imaging X-ray spectrometer

A process for fabricating an X-ray spectrometer having imaging and energy resolution of X-ray sources is discussed. The spectrometer has an array of adjoinging rectangularly shaped detector cells formed in a silicon body. The walls of the cells are created by laser drilling holes completely through the silicon body and diffusing n(+) phosphorous doping material therethrough. A thermally migrated aluminum electrode is formed centrally through each of the cells.

Alcorn, G. E.↗

Multiple scattering lidar returns from stratus clouds

Multiple scattering lidar returns from stratus clouds were measured using a multi-field-of-view (MFOV) lidar operating at 1.054 microns. The detector consists of four concentric silicon photodiodes which define half-angle fields of view (FOV) of 3.8, 12.5, 25 and 38.5 mrad. The central FOV receives the conventional lidar signal, while the outer FOV's receive only multiply scattered contributions. The ratios of the signals in the outer FOV's to the signal in the central FOV is an indication of the lateral spreading of the scattered component of the laser pulse as it propagates through the cloud. MFOV lidar returns from stratus clouds measured between October 1991 and March 1992 can be divided into two distinct types, those with large multiple scattering ratios and those with small ratios. An example of each type of return is shown. Both measurements were made at an elevation angle of 45 degrees. Clouds with small multiple scattering signals probably have a high concentration of much larger particles on the order of hundreds of micrometers in size. This is a typical size range for suspended ice crystals or precipitations. Stratus clouds often have a high concentration of ice crystals even when there is no precipitation. Large ice crystals would give smaller signals in the outer FOV's because much of the scattered intensity is contained in a narrow diffraction peak with an angular width on the order of milliradians. The result is that for a given extinction, many more orders of scattering are required for the laser pulse to spread out. So far we have not been able to do simulations of MFOV lidar returns from ice crystal clouds because of uncertainties about the phase function of the crystals, particularly the magnitude of the backscatter peak at 180 degrees. On two occasions, MFOV lidar returns measured just prior to snowfall, showed a striking vertical profile. An example is shown. From 900 to 1300m, the multiply scattered signals are negligible compared to the return in the central FOV. Abruptly, at 1300m strong signals begin in the outer FOVs. These results could be explained by the presence of a cloud layer composed of water droplets at a range of 1300m (or 900m above ground) with snow precipitations forming at the bottom of the cloud. By measuring the polarization ratio of lidar signals, Pal and Carswell have observed snow precipitating from a cloud layer composed of water droplets. Based on these results, we believe that analysis of multiple scattering lidar returns can yield important information on the phase of cloud particles.

Hutt, D. L.↗

Photon detection with parallel asynchronous processing

An approach to photon detection with a parallel asynchronous signal processor is described. The visible or IR photon-detection capability of the silicon p(+)-n-n(+) detectors and the parallel asynchronous processing are addressed separately. This approach would permit an independent analog processing channel to be dedicated to every pixel. A laminar architecture consisting of a stack of planar arrays of the devices would form a 2D array processor with a 2D array of inputs located directly behind a focal-plane detector array. A 2D image data stream would propagate in neuronlike asynchronous pulse-coded form through the laminar processor. Such systems can integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The possibility of multispectral image processing is addressed.

Coon, D. D.↗

Measuring atmospheric dispersion with WLRS in multiple wavelength mode

The WLRS (Wettzell Laser Ranging System) allows the simultaneous tracking of satellites on two different wavelengths. These are the fundamental frequency of Nd:YAG at 1.064 microns and the second harmonic at 532 nm. Range measurements to the satellite LAGEOS were carried out with different experimental set-ups, after developing a detector unit based on a silicon avalanche photodiode in Geiger mode, which is sufficiently sensitive in the infrared domain. An approach towards a quantitative interpretation of the data is suggested and discussed briefly.

Schreiber, Ulrich↗

Microfossils of Cyanobacteria in Carbonaceous Meteorites

During the past decade, Environmental and Field Emission Scanning Electron Microscopes have been used at the NASA/Marshall Space Flight Center to investigate freshly fractured interior surfaces of a large number of different types of meteorites. Large, complex, microfossils with clearly recognizable biological affinities have been found embedded in several carbonaceous meteorites. Similar forms were notably absent in all stony and nickel-iron meteorites investigated. The forms encountered are consistent in size and morphology with morphotypes of known genera of Cyanobacteria and microorganisms that are typically encountered in associated benthic prokaryotic mats. Even though many coccoidal and isodiametric filamentous cyanobacteria have a strong morphological convergence with some other spherical and filamentous bacteria and algae, many genera of heteropolar cyanobacteria have distinctive apical and basal regions and cellular differentiation that makes it possible to unambiguously recognize the forms based entirely upon cellular dimensions, filament size and distinctive morphological characteristics. For almost two centuries, these morphological characteristics have historically provided the basis for the systematics and taxonomy of cyanobacteria. This paper presents ESEM and FESEM images of embedded filaments and thick mats found in-situ in the Murchison CM2 and Orgueil cn carbonaceous meteorites. Comparative images are also provided for known genera and species of cyanobacteria and other microbial extremophiles. Energy Dispersive X-ray Spectroscopy (EDS) studies indicate that the meteorite filaments typically exhibit dramatic chemical differentiation with distinctive difference between the possible microfossil and the meteorite matrix in the immediate proximity. Chemical differentiation is also observed within these microstructures with many of the permineralized filaments enveloped within electron transparent carbonaceous sheaths. Elemental distributions of these embedded filaments are not consistent with recent cyanobacteria or other living or preserved microbial extremophiles that have been investigated during this research. The meteorite filaments often have nitrogen content below the sensitivity level of the EDS detector. Carbon, Sulphur, Iron or Silicon are often highly enriched and hence anomalous C/N and CIS ratios when compared with modem cyanobacteria. The meteorite forms that are unambiguously recognizable as biological filaments are interpreted as indigenous microfossils analogous to several known genera of modem cyanobacteria and associated trichomic filamentous prokaryotes.

Hoover, Richard B.↗

Pointing Reference Scheme for Free-Space Optical Communications Systems

A scheme is proposed for referencing the propagation direction of the transmit laser signal in pointing a free-space optical communications terminal. This recently developed scheme enables the use of low-cost, commercial silicon-based sensors for tracking the direction of the transmit laser, regardless of the transmit wavelength. Compared with previous methods, the scheme offers some advantages of less mechanical and optical complexity and avoids expensive and exotic sensor technologies. In free-space optical communications, the transmit beam must be accurately pointed toward the receiver in order to maintain the communication link. The current approaches to achieve this function call for part of the transmit beam to be split off and projected onto an optical sensor used to infer the pointed direction. This requires that the optical sensor be sensitive to the wavelength of the transmit laser. If a different transmit wavelength is desired, for example to obtain a source capable of higher data rates, this can become quite impractical because of the unavailability or inefficiency of sensors at these wavelengths. The innovation proposed here decouples this requirement by allowing any transmit wavelength to be used with any sensor. We have applied this idea to a particular system that transmits at the standard telecommunication wavelength of 1,550 nm and uses a silicon-based sensor, sensitive from 0.5 to 1.0 micrometers, to determine the pointing direction. The scheme shown in the figure involves integrating a low-power 980-nm reference or boresight laser beam coupled to the 1,550-nm transmit beam via a wavelength-division-multiplexed fiber coupler. Both of these signals propagate through the optical fiber where they achieve an extremely high level of co-alignment before they are launched into the telescope. The telescope uses a dichroic beam splitter to reflect the 980- nm beam onto the silicon image sensor (a quad detector, charge-coupled device, or active-pixel-sensor array) while the 1,550- nm signal beam is transmitted through the optical assembly toward the remotely located receiver. Since the 980-nm reference signal originates from the same single-mode fiber-coupled source as the transmit signal, its position on the sensor is used to accurately determine the propagation direction of the transmit signal. The optics are considerably simpler in the proposed scheme due to the use of a single aperture for transmitting and receiving. Moreover, the issue of mechanical misalignment does not arise because the reference signal and transmitted laser beams are inherently co-aligned. The beam quality of the 980-nm reference signal used for tracking is required to be circularly symmetric and stable at the tracking-plane sensor array in order to minimize error in the centroiding algorithm of the pointing system. However, since the transmit signal is delivered through a fiber that supports a single mode at 1,550 nm, propagation of higher order 980-nm modes is possible. Preliminary analysis shows that the overall mode profile is dominated by the fundamental mode, giving a near symmetric profile. The instability of the mode was also measured and found to be negligible in comparison to the other error contributions in the centroid position on the sensor array.

Wright, Malcolm↗

Laboratory Instruments Available to Support Space Station Researchers at Marshall Space Flight Center

A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.

Panda, Binayak↗

Characterization and Absolute QE Measurements of Delta-Doped N-Channel and P-Channel CCDs

In this paper we present the methodology for making absolute quantum efficiency (QE) measurements from the vacuum ultraviolet (VUV) through the near infrared (NIR) on delta-doped silicon CCDs. Delta-doped detectors provide an excellent platform to validate measurements through the VUV due to their enhanced UV response. The requirements for measuring QE through the VUV are more strenuous than measurements in the near UV and necessitate, among other things, the use of a vacuum monochromator, and good camera vacuum to prevent chip condensation, and more stringent handling requirements. The system used for these measurements was originally designed for deep UV characterization of CCDs for the WF/PC instrument on Hubble and later for Cassini CCDs.

Jacquot, Blake C.↗

Exploration of methods to remove implanted 210 Pb and 210 Po contamination from silicon surfaces

Radioactive contaminants on the surfaces of detector components can be a problematic source of background events for physics experiments searching for rare processes. Exposure to radon is a specific concern because it can result in the relatively long-lived 210 Pb (and progeny) being implanted to significant subsurface depths such that removal is challenging. Here, in this article, we present results from a broad exploration of cleaning treatments to remove implanted 210 Pb and 210 Po contamination from silicon, which is a material frequently used in rare-events searches. We demonstrate for the first time that heat treatments (“baking”) can effectively mitigate such surface contamination, with a 1200 °C bake resulting in a 97$^{+2}_{-3}$% reduction. We also report results using wet-chemistry and plasma-based methods, which show that etching can be highly effective provided the etch depth is sufficiently aggressive. Our survey of cleaning methods suggests consideration of multiple approaches during the different phases of detector construction to enable greater flexibility for efficient removal of 210 Pb and 210 Po surface contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-Fabricated Solid-State Radiation Detectors for Active Personal Dosimetry

Active radiation dosimetry is important to human health and equipment functionality for space applications outside the protective environment of a space station or vehicle. This is especially true for long duration missions to the moon, where the lack of a magnetic field offers no protection from space radiation to those on extravehicular activities. In order to improve functionality, durability and reliability of radiation dosimeters for future NASA lunar missions, single crystal silicon carbide devices and scintillating fiber detectors are currently being investigated for applications in advanced extravehicular systems. For many years, NASA Glenn Research Center has led significant efforts in silicon carbide semiconductor technology research and instrumentation research for sensor applications under extreme conditions. This report summarizes the technical progress and accomplishments toward characterization of radiation-sensing components for the recommendation of their fitness for advanced dosimetry development.

Wrbanek, John D.↗

Advanced detectors and signal processing

Continued progress is reported toward development of a silicon on garnet technology which would allow fabrication of advanced detection and signal processing circuits on bubble memories. The first integrated detectors and propagation patterns have been designed and incorporated on a new mask set. In addition, annealing studies on spacer layers are performed. Based on those studies, a new double layer spacer is proposed which should reduce contamination of the silicon originating in the substrate. Finally, the magnetic sensitivity of uncontaminated detectors from the last lot of wafers is measured. The measured sensitivity is lower than anticipated but still higher than present magnetoresistive detectors.

Greve, D. W.↗