At least 721 records · Page 40

Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled CF{sub 4} plasmas

Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this type of plasma source, ballistic electrons originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased electrode and are then accelerated in the sheath toward an opposite non-dc biased lower electrode. For electropositive (argon) plasmas it has been shown that the primary contribution of ballistic electrons is ionization in the dc sheath and modulation of the discharge properties. Whether applied dc power net increases or decreases the plasma electron density depends on the rf power environment of the opposing substrate electrode. When rf power is applied to a substrate electrode, the rf self-bias creates a potential well that traps the ballistic electrons, the result being that the electron density increases with dc power. In most cases the fraction of high energy electrons that reach the electrode is small. In this article, the authors describe the use of test particle Monte Carlo simulations to describe the behavior of hybrid dc/rf electronegative (CF{sub 4}) plasmas. In contrast to the behavior in argon, process experiments with electronegative gases such as CF{sub 4} indicate that the electron density is independent of dc bias power when no rf power is applied to the wafer. Test particle simulations show that CF{sub 4} provides for a 'self-confinement' effect caused by large cross sections for vibrational excitation at intermediate to low electron energies, which results in weak dependence of electron density on dc bias voltage when low frequency bias is not applied to the wafer. This emphasizes the important role of gas composition and cross-section structure in the control of dc/rf plasmas. Consistent with experiment, test particle Monte Carlo simulations also show that when rf is applied to the substrate, overall the CF{sub 4} plasma's macroscopic properties are similar manner to argon plasmas. Even so, differences between the argon and CF{sub 4} plasmas occur related to the scaling of the fraction of ballistic electrons that reach the wafer as a function of dc and rf power. A regime is identified in which CF{sub 4} and argon plasmas have the equivalent ratio of ballistic to thermal electron density adjacent to the surface. The authors explain that the differences are related to different thermalization and ionization mechanisms in these plasmas. In addition, they find the electron attachment constant is zero in the dc sheath and nearly constant value in the bulk as the transit time in the sheath is far less than the mean attachment time. The same simple function to express ionization rate constant as a function of electric field in the dc sheath, developed for argon, can be also applied to CF{sub 4}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle-in-cell simulations and passive bulk model of collisional capacitive discharge

Intermediate pressure (0.2–6.0 Torr), radio frequency capacitive discharges are of increasing importance in the thin film processing industry. However, existing low pressure (<0.1 Torr) discharge models are often used beyond their applicability in this pressure range. In this work, the authors performed one-dimensional particle-in-cell (PIC) simulations of a capacitive 2.5 cm gap argon discharge driven at 13.56 MHz with current density amplitude J 0 50 A/m 2 over a wide range of gas pressures p g = 0.04–20 Torr. For intermediate pressures, the PIC results showed that most of the ionization occurs near the plasma-sheath edges with very little occurring within the central bulk region. This led us to develop a “passive bulk” model of the discharge in which bulk electron heating does not contribute to ionization, and all the ionization is due solely to the sheath-heated electrons. The model assumes a constant ion-neutral mean free path λ i in the plasma bulk and either constant λ i or constant ion mobility μ i in the sheaths. The model is solved using an electron temperature iteration scheme. The PIC scalings of the discharge equilibrium parameters (e.g., electron density and temperature, sheath width, and voltage) with the input parameters p g and J 0 showed good agreement with those of the passive bulk model. A constant μ i sheath model showed the best agreement with the PIC results in the intermediate pressure regime of interest, but a constant λ i model is simpler to implement and showed reasonable agreement over a wide pressure range.

36 MATERIALS SCIENCE↗

Generalized Bohm’s criterion and negative anode voltage fall in electric discharges

The value of the voltage fall across the anode sheath is found as a function of the current density. Analytic solutions are obtained in a wide range of the ratio of the directed velocity of plasma electrons v{sub 0} to their thermal velocity v{sub T}. It is shown that the voltage fall in a one-dimensional collisionless anode sheath is always negative. At the small values of v{sub 0}/v{sub T}, the obtained expression asymptotically transforms into the Langmuir formula. Generalized Bohm’s criterion for an electric discharge with allowance for the space charge density ρ(0), electric field E(0), ion velocity v{sub i}(0), and ratio v{sub 0}/v{sub T} at the plasma-sheath interface is formulated. It is shown that the minimum value of the ion velocity v{sub i}{sup *}(0) corresponds to the vanishing of the electric field at one point inside the sheath. The dependence of v{sub i}{sup *} (0) on ρ(0), E(0), and v{sub 0}/v{sub T} determines the boundary of the existence domain of stationary solutions in the sheath. Using this criterion, the maximum possible degree of contraction of the electron current at the anode is determined for a short high-current vacuum arc discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Floating potential of emitting surfaces in plasmas with respect to the space potential

The potential difference between a floating emitting surface and the plasma surrounding it has been described by several sheath models, including the space-charge-limited sheath, the electron sheath with high emission current, and the inverse sheath produced by charge-exchange ion trapping. Our measurements reveal that each of these models has its own regime of validity. We determine the potential of an emissive filament relative to the plasma potential, emphasizing variations in emitted current density and neutral particle density. The potential of a filament in a diffuse plasma is first shown to vanish, consistent with the electron sheath model and increasing electron emission. In a denser plasma with ample neutral pressure, the floating filament potential is positive, as predicted by a derived ion trapping condition. In conclusion, the filament floated negatively in a third plasma, where flowing ions and electrons and nonnegligible electric fields may have disrupted ion trapping. Depending on the regime chosen, emitting surfaces can float positively or negatively with respect to the plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating instabilities in magnetized low-pressure capacitively coupled RF plasma using particle-in-cell (PIC) simulations

The effect of a uniform magnetic field on particle transport in low-pressure radio frequency (RF) capacitively coupled plasma (CCP) has been studied using a particle-in-cell model. Three distinct regimes of plasma behavior can be identified as a function of the magnetic field. In the first regime at low magnetic fields, asymmetric plasma profiles are observed within the CCP chamber due to the effect of $\overrightarrow{E}$ × $\overrightarrow{B}$ drift. As the magnetic field increases, instabilities develop and form self-organized spoke-shaped structures that are distinctly seen within the bulk plasma closer to the sheath. In this second regime, the spoke-shaped coherent structures rotate inside the plasma chamber in the -$\overrightarrow{E}$ × $\overrightarrow{B}$ direction, where $\overrightarrow{E}$ × $\overrightarrow{B}$ are the DC electric and magnetic field vectors, respectively, and the DC electric field exists in the sheath and pre-sheath regions. The spoke rotation frequency is in the megahertz range. As the magnetic field strength increases further, the rotating coherent spokes continue to exist near the sheath. The coherent structures are, however, accompanied by new small-scale incoherent structures originating and moving within the bulk plasma region away from the sheath. This is the third regime of plasma behavior. The threshold values of the magnetic field between these regimes were found not to vary with changing plasma reactor geometry (e.g., area ratio between ground and powered electrodes) or the use of an external capacitor between the RF-powered electrode and the RF source. The threshold values of the magnetic field between these regimes shift toward higher values with increasing gas pressure. Analysis of the results indicates that the rotating structures are due to the lower hybrid instability driven by density gradients and electron-neutral collisions. This paper provides guidance on the upper limit of the magnetic field for instability-free operation in low-pressure CCP-based semiconductor deposition and etch systems that use the external magnetic field for plasma uniformity control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding carbon sourcing and transport originating from the helicon antenna surfaces during high-power helicon discharge in DIII-D Tokamak

The high-power helicon wave system in the DIII-D tokamak could potentially introduce new plasma–material interaction (PMI) challenges owing to rectified RF sheath potentials that develop near the antenna and surrounding plasma-facing components. We present the first application of the STRIPE (Simulated Transport of RF Impurity Production and Emission) framework to helicon-induced PMIs, extending previous STRIPE studies of ICRH antennas by incorporating net erosion, local re-deposition, and three-dimensional global impurity transport. The integrated workflow couples SOLPS, COMSOL, RustBCA, GITR, and GITRm to simulate carbon erosion, re-deposition, and impurity transport for two experimentally constrained DIII-D H-mode helicon operating scenarios with different antenna–plasma gaps, coupled RF powers, and edge plasma conditions. COMSOL predicts rectified RF sheath potentials of 1–5 kV localized near the lower portion of the antenna, where the magnetic field intersects the surface at grazing incidence. Carbon self-sputtering dominates the erosion source, whereas RF-accelerated D + ions contribute approximately 1% of the total gross erosion. The smaller-gap operating scenario exhibits substantially stronger gross erosion, enhanced local re-deposition (∼12%), and a larger confined carbon inventory owing to increased plasma accessibility and broader RF sheath coverage. Comparison with available DIII-D measurements shows no distinct change in the global carbon signal that correlates with the helicon RF pulse, consistent with the simulations indicating that the helicon-generated carbon source remains small compared with the existing background carbon inventory under the present graphite-wall operating conditions. These results demonstrate the capability of STRIPE to integrate RF sheath modeling, plasma transport, surface interaction physics, and three-dimensional impurity transport for the interpretation of helicon-induced PMIs. The study further identifies the principal sources of modeling uncertainty, including grazing-angle RF sheath physics, slow-wave resolution, plasma-background extrapolation, and trace-impurity transport assumptions, providing a framework for future validation and model development.

Kumar, Atul [Oak Ridge National Laboratory (ORNL),↗

Image reconstruction of shielded mixed-oxide fuel using a dual-particle imaging system

The dual-particle imaging system being developed at the University of Michigan was used at the Joint Research Centre in Ispra, Italy for measurements on samples of special nuclear material. A 1,150-g mixed-oxide (MOX) fuel sample was measured with various shielding configurations to determine how the presence of lead and/or polyethylene shielding degrades the system's ability to localize a source by simultaneous neutron and photon imaging. Three two-hour measurements were taken with the source shielded by an: a) 8-mm lead sheath and 5.1-cm lead bricks, b) 8-mm lead sheath and 6.5-cm polyethylene bricks, and c) 8-mm lead sheath, 5.1-cm lead bricks, and 6.5-cm polyethylene bricks. The 8-mm lead sheath was used in all cases to reduce the measured photon count rate. A “bare” measurement was also made by using only the 8-mm lead sheath, but the unexpected presence of additional sources has rendered the measurement unsuitable for comparison. Here, the resulting images show that the dual-particle imaging system is able to accurately localize the MOX canister in the presence of intervening material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-R Walls for New Construction Structural Performance: Integrated Rim Header Testing

The Building America Program takes two prominent approaches to construct higher R-value walls: larger dimension framing and exterior rigid foam insulation. These have had some success; however, for many production builders the cost of changing framing systems is high, so the changes have been slowly realized. Also, recent building code changes have raised some performance issues for exterior sheathing and raised heel trusses, for example, that indicates a need for continued performance testing of wall systems. Furthermore, some material use survey data have shown that often when builders are switching to 2 × 6 framing members, they commonly use of 16-in. o.c. spacing. The opportunity to (1) encourage the use of thicker framing systems for much higher R-value walls; (2) construct wall systems that optimize the framing use to reduce thermal breaks; and (3) extract opportunities to reduce costs, all remain high priorities for the Building America program, the NAHB Research Center Industry Partnership, and builders. Similarly for the use of exterior rigid sheathing, builders and researchers have investigated alternative bracing techniques to eliminate the use of wood structural sheathing in lieu of foam board sheathing. Structural characteristics, especially in the direction perpendicular to the sheathing, have been reevaluated for the building codes. These include pressure equalization issues across multiple layers of the wall system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Extended Plate and Beam Wall System in a Cold-Climate House

This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders. The EP&B design combines optimized framing with integrated rigid foam sheathing to increase the wall system's R-value and reduce thermal bridging. The foam sheathing is installed between the wall studs and structural wood sheathing. The exterior wood sheathing is attached directly to a framing extension formed by extended top and bottom plates. The exterior wood sheathing can dry to the exterior and provides bracing, a clear drainage plane and flashing surface for window and door openings, and a nailing surface for siding attachment. With support of the DOE Building America program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a NCTH in Lancaster, PA to demonstrate the EP&B wall design in a cold climate (IECC climate zone 5A). The results of the study confirmed the benefits of the systems and the viability of its integration into the house construction process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.

Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .

47 OTHER INSTRUMENTATION↗

Ion extraction from a plasma

An experimental investigation of the physical processes governing ion extraction from a plasma is presented. The screen hole plasma sheath of a multiaperture ion accelerator system is defined by equipotential plots for a variety of accelerator system geometries and operating conditions. A sheath thickness of at least fifteen Debye lengths is shown to be typical. The electron density variation within the sheath satisfies a Maxwell Boltzmann density distribution at an effective electron temperature dependent on the discharge plasma primary to Maxwellian electron density ratio. Plasma ion flow up to and through the sheath is predominately one dimensional and the ions enter the sheath with a modified Bohm velocity. Low values of the screen grid thickness to screen hole diameter ratio give good ion focusing and high extracted ion currents because of the effect of screen webbing on ion focusing.

Aston, G.↗

Magnetospherically trapped ions as a source of magnetosheath energetic ions

It has been suggested that energetic ions observed in the magnetosheath may be due to the direct leakage of trapped magnetospheric ions. To test this hypothesis, three-dimensional ion spectra from the energetic particle experiment on ISEE 1 for a magnetopause crossing on Nov. 10, 1977 are utilized to construct three-dimensional distribution functions in the magnetosphere and in the sheath. Using the observed magnetic field, a simple one-dimensional model of the magnetopause is developed. Ions are then followed in the model, starting in the magnetosphere, through the magnetopause and ending up in the sheath. Using Liouville's Theorem a model sheath distribution function is then built up by following the magnetospheric distribution function through the model fields. The model distribution is then compared with the observed sheath distribution. For this case it is found that the main features of the observed ions in the sheath are consistent with direct leakage and with no energization or de-energization processes, and an inward-pointing normal component is required. The energetic particles mapped in this case apparently follow a flux tube which does not penetrate the magnetopause where local tangential electric fields have been reported.

Speiser, T. W.↗

Ion extraction from a plasma

The physical processes governing ion extraction from a plasma have been examined experimentally. The screen hole plasma sheath (the transition region wherein significant ion acceleration and complete electron retardation occurs) has been defined by equipotential plots for a variety of ion accelerator system geometries and operating conditions. It was found that the screen hole plasma sheath extends over a large distance, and influences ion and electron trajectories at least 15 Debye lengths within the discharge chamber. The electron density variation within the screen hole plasma sheath satisfied a Maxwell-Boltzmann density distribution at an effective electron temperature dependent on the discharge plasma primary-to-Maxwellian electron density ratio. Plasma ion flow up to and through the sheath was predominantly one-dimensional, and the ions entered the sheath region with a modified Bohm velocity. Low values of the screen grid thickness to screen hole diameter ratio were found to give good ion focusing and high extracted ion currents because of the effect of screen webbing on ion focusing.

Aston, G.↗

Plasma electron collection through biased slits in a dielectric

A large number of experimental and analytical efforts have been directed toward understanding the plasma sheath growth and discharge phenomena which lead to high-voltage solar array/space plasma interactions. An important question which has not been addressed is how the voltage gradient in the plasma sheath near the surface of such an array may affect these interactions. The purpose of the experimental study described in this paper is to examine the merging of the sheaths around biased slits in a dielectric and how this affects the collection of electrons through these slits. The data, which are obtained by emissive probes and direct measurement of the current collected through the slits, indicate that when the sheaths merge the current collection by the slits is significantly altered with the most positive slit collecting more electrons than it otherwise would. Therefore, the effect of a voltage gradient in the sheath around a solar array should be considered when evaluating solar array performance.

Carruth, M. R., Jr.↗

Three-dimensional numerical simulation of current collection by a probe in a magnetized plasma

A three-dimensional numerical model for current collection in a magnetized plasma is reported. The model is based on an electrostatic particle-in-cell code. The model yields self-consistent sheath structure including distributions of plasma and the electric potential around the body and the collection of electrons. The analytical theory of current collection by a body in a magnetized plasma yields an upper bound for the collected current determined by the conservation of energy and canonical angular momentum. The theory shows that the collected charged particles come from a cylindrical volume aligned with the magnetic shadow of the body; the maximum radius r(sub o) of this volume is determined by the body size, body potential, and the ambient magnetic field. This theory does not deal with the sheath structure around the body. The condition for the actual current to approach the upper-bound value has been a matter of debate. Our simulations reveal when and why the collected current becomes equal to its upper-bound value. Sheath size in the radial direction perpendicular to the axial ambient magnetic field is determined by the current-limiting radius r(sub o). Our simulation yields time-average current in good agreement with its upper bound. This feature of the current collection is explained as follows: Once electrons enter the sheath, some of them are freely accelerated perpendicular to the magnetic field because they are demagnetized by the large gradients in the perpendicular electric fields. Simulations show a large perpendicular acceleration, producing perpendicular energy as large as that determined by the potential on the body, especially in the region where perpendicular electric fields (E perpendicular) are the strongest. An analysis shows that the demagnetization of electrons occurs above a threshold potential on the body. This threshold condition follows from the breakdown of the adiabaticity of the electron dynamics inside the sheath.

Singh, Nagendra↗

Mineralized Remains of Morphotypes of Filamentous Cyanobacteria in Carbonaceous Meteorites

The quest for conclusive evidence of microfossils in meteorites has been elusive. One difficulty arises from the fact than many abiotic or inorganic microstructures, mineral grains, and coating artifacts can mimic the smaller representatives of the microbial world that possess very simple morphologies (unicellular cocci or bacilli). However, there exist a wide variety of large, filamentous trichomic prokaryotic microorganisms (cyanobacteria and sulfur bacteria) with sufficiently well known and complex morphologies that they can be recognized and are known to be of unquestionable biogenic origin. The taphonomic modes of fossilization and their of their life habits and processes frequently result in distinctive chemical biosignatures associated with carbonization, silicification, calcification, phosphatization and metal-binding properties of their cell-walls, trichomes, sheaths and extracellular polymeric substances (EPS). Strong differences of mineral concentrations in closely associated and visibly differentiated cellular microstructures provide strong evidence of biogenicity. This evidence is further enhanced by the detection of recognizable and distinct microstructures (e.g., uniseriate or multiseriate filaments, trichomes, sheaths, cells of proper sizes and size distributions) and growth characteristics (e.g., basal or apical cells, true or false branching of trichomes, tapered or uniform filaments, robust or thin sheaths) and reproductive and nitrogen fixation habits (e.g., baeocytes, hormogonia, akinetes and heterocysts), Microfossils of cyanobacteria and cyanobacterial mats and stromatolites have been recognized a described from many of the most ancient rocks on Earth. The crucial problem lies in developing valid protocols and methodologies for establishing that the putative microfossils are truly indigenous and not merely recent microbial contaminants. During the past several years, we have conducted Field Emission Scanning Electron Microscopy (FESEM) investigations of freshly fractured interior surfaces of carbonaceous meteorites, terrestrial rocks, and recent microbial extremophiles and filamentous cyanobacteria. These studies have resulted in the detection in a several carbonaceous meteorites of the mineralized remains of a wide variety of complex filamentous trichomic microorganisms. These embedded forms are consistent in size and microstructure with well-preserved morphotypes of mat- forming filamentous trichomic cyanobacteria and the degraded remains of microfibrils of cyanobacterial sheaths. We present the results of comparative imaging studies and EDAX elemental analyses of recent cyanobacteria (e.g. Calothrix, Oscillatoria, and Lyngbya) that are similar in size, morphology and microstructure to morphotypes found embedded in meteorites. EDAX elemental studies reveal that forms found in carbonaceous meteorites often have highly carbonized sheaths in close association with permineralized filaments, trichomes and microbial cells. Ratios of critical bioelements (C:O, C:N, C:P, and C:S) reveal dramatic differences between microfossils in Earth rocks and meteorites and in filaments, trichomes, hormogonia, and cells of recent cyanobacteria.

Hoover, Richard B.↗

Improved Blackbody Temperature Sensors for a Vacuum Furnace

Some improvements have been made in the design and fabrication of blackbody sensors (BBSs) used to measure the temperature of a heater core in a vacuum furnace. Each BBS consists of a ring of thermally conductive, high-melting-temperature material with two tantalum-sheathed thermocouples attached at diametrically opposite points. The name "blackbody sensor" reflects the basic principle of operation. Heat is transferred between the ring and the furnace heater core primarily by blackbody radiation, heat is conducted through the ring to the thermocouples, and the temperature of the ring (and, hence, the temperature of the heater core) is measured by use of the thermocouples. Two main requirements have guided the development of these BBSs: (1) The rings should have as high an emissivity as possible in order to maximize the heat-transfer rate and thereby maximize temperature-monitoring performance and (2) the thermocouples must be joined to the rings in such a way as to ensure long-term, reliable intimate thermal contact. The problem of fabricating a BBS to satisfy these requirements is complicated by an application-specific prohibition against overheating and thereby damaging nearby instrumentation leads through the use of conventional furnace brazing or any other technique that involves heating the entire BBS and its surroundings. The problem is further complicated by another application-specific prohibition against damaging the thin tantalum thermocouple sheaths through the use of conventional welding to join the thermocouples to the ring. The first BBS rings were made of graphite. The tantalum-sheathed thermocouples were attached to the graphite rings by use of high-temperature graphite cements. The ring/thermocouple bonds thus formed were found to be weak and unreliable, and so graphite rings and graphite cements were abandoned. Now, each BBS ring is made from one of two materials: either tantalum or a molybdenum/titanium/zirconium alloy. The tantalum-sheathed thermocouples are bonded to the ring by laser brazing. The primary advantage of laser brazing over furnace brazing is that in laser brazing, it is possible to form a brazed connection locally, without heating nearby parts to the flow temperature of the brazing material. Hence, it is possible to comply with the prohibition against overheating nearby instrumentation leads. Also, in laser brazing, unlike in furnace brazing, it is possible to exert control over the thermal energy to such a high degree that it becomes possible to braze the thermocouples to the ring without burning through the thin tantalum sheaths on the thermocouples. The brazing material used in the laser brazing process is a titanium-boron paste. This brazing material can withstand use at temperatures up to about 1,400 C. In thermal-cycling tests performed thus far, no debonding between the rings and thermocouples has been observed. Emissivity coatings about 0.001 in. (.0.025 mm) thick applied to the interior surfaces of the rings have been found to improve the performance of the BBS sensors by raising the apparent emissivities of the rings. In thermal-cycling tests, the coatings were found to adhere well to the rings.

Farmer, Jeff↗