Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Multifunctional Superconducting Nanowire Quantum Sensors

Superconducting nanowire single-photon detectors (SNSPDs) offer high-quantum-efficiency and low-dark-count-rate single-photon detection. In a growing number of cases, large magnetic fields are being incorporated into quantum microscopes, nanophotonic devices, and sensors for nuclear and high-energy physics that rely on SNSPDs, but superconducting devices generally perform poorly in large magnetic fields. Here, we demonstrate robust performance of amorphous SNSPDs in magnetic fields of up to ±6 T with a negligible dark-count rate and unchanged quantum efficiency at typical bias currents. Critically, we also show that the SNSPD can be used as a magnetometer with a sensitivity of better than 100μT/√Hz and as a thermometer with a sensitivity of 20μK/√Hz at 1 K. Thus, a single-photon detector integrated into a quantum device can be used as a multifunctional quantum sensor capable of describing the temperature and magnetic field on chip simply by varying the bias current to change the operating modality from single-photon detection to thermometry or magnetometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distributed fibre-optic temperature sensor for cryogenic applications based on detection of boson components of Raman light scattering

The possibility of designing a distributed fibre-optic sensor, allowing one to measure cryogenic temperatures (to liquid nitrogen boiling point), is experimentally demonstrated. The principle of operation of the sensor is based on measuring the intensity of boson peaks of Raman scattering in a fibre material, which are spaced by 1 to 3 THz from the probe frequency. The measurements are performed using a single-mode telecommunication fibre with a 15-μm-thick polyimide coating. The probe wavelength is 1.55 μm, the sensor spatial resolution is 4 m, and the averaging time is 60 s. Experiments are carried out in the temperature range of 75.6 – 79.6 K, with a temperature resolution of 0.5 K. (paper)

36 MATERIALS SCIENCE↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Trustworthiness and Trust: Identifying Factors that Drive Successful Human-AI Interaction in Nuclear Power Plant Applications

Emerging technologies such as artificial intelligence (AI) and machine learning (ML) are rapidly evolving and considered a promising tool for efficient and continued safe operations of the U.S. nuclear power plants (NPPs). Emerging AI techniques like large language models (LLMs) are one such technology that may support personnel at existing NPPs perform work more efficiently. For example, operators may query the current operational status of a power plant via a chat interface leveraging LLMs to access plant-related information in an interactive manner rather than manually collecting various sensor data for tasks such as surveillances or completing work orders. This is a fundamental shift in the way operators currently perform their tasks today. The literature of human-automation interaction indicates that trust is a crucial factor that drives successful interaction between a human operator and an automated system, like an AI-infused NPP application. This work presents the results of a literature review on key factors that relate to trust in AI/LLM technologies for NPP applications. The relevant literature of human factors and cognitive engineering has identified various factors related to trust including trustworthiness, performance characteristics, operator skill and perceived risk. This preliminary literature review will guide development and evaluation of models involving the identified factors influencing trust in AI and develop a framework for human-centered design for interface between humans and AI. By addressing trust, this work supports developing a technical basis for designing key characteristics of AI/LLM to support calibrated trust, which will ultimately support wide-scale adoption of AI/LLM technologies, as well as ensure safe, effective, and reliable use.

99 - GENERAL AND MISCELLANEOUS↗

A Review of Inkjet Printed Graphene and Carbon Nanotubes Based Gas Sensors

Graphene and carbon nanotube (CNT)-based gas/vapor sensors have gained much traction for numerous applications over the last decade due to their excellent sensing performance at ambient conditions. Inkjet printing various forms of graphene (reduced graphene oxide or modified graphene) and CNT (single-wall nanotubes (SWNTs) or multiwall nanotubes (MWNTs)) nanomaterials allows fabrication onto flexible substrates which enable gas sensing applications in flexible electronics. This review focuses on their recent developments and provides an overview of the state-of-the-art in inkjet printing of graphene and CNT based sensors targeting gases, such as NO 2 , Cl 2 , CO 2 , NH 3 , and organic vapors. Moreover, this review presents the current enhancements and challenges of printing CNT and graphene-based gas/vapor sensors, the role of defects, and advanced printing techniques using these nanomaterials, while highlighting challenges in reliability and reproducibility. The future potential and outlook of this rapidly growing research are analyzed as well.

flexible electronics↗

Conditional quantum plasmonic sensing

The possibility of using weak optical signals to perform sensing of delicate samples constitutes one of the main goals of quantum photonic sensing. Furthermore, the nanoscale confinement of electromagnetic near fields in photonic platforms through surface plasmon polaritons has motivated the development of highly sensitive quantum plasmonic sensors. Despite the enormous potential of plasmonic platforms for sensing, this class of sensors is ultimately limited by the quantum statistical fluctuations of surface plasmons. Indeed, the fluctuations of the electromagnetic field severely limit the performance of quantum plasmonic sensing platforms in which delicate samples are characterized using weak near-field signals. Furthermore, the inherent losses associated with plasmonic fields levy additional constraints that challenge the realization of sensitivities beyond the shot-noise limit. Here, we introduce a protocol for quantum plasmonic sensing based on the conditional detection of plasmons. We demonstrate that the conditional detection of plasmonic fields, via plasmon subtraction, provides a new degree of freedom to control quantum fluctuations of plasmonic fields. This mechanism enables improvement of the signal-to-noise ratio of photonic sensors relying on plasmonic signals that are comparable to their associated field fluctuations. Consequently, the possibility of using weak plasmonic signals to sense delicate samples, while preserving the sample properties, has important implications for molecule sensing, and chemical detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Reverse Osmosis (RO) are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in (ultra-filtration) UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square error (RMSE) metric. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent covariates across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is studied for both direct and recursive RF modelling approaches across increasing forecast horizons. Accurate prediction of initial TMP is critical for optimizing RO operations, as it enables the development of robust modelling frameworks by accurately estimating membrane fouling trends, thereby enhancing process efficiency and long-term reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of Digital Twin Sensing Strategies Via Predictive Modeling and Interpretable Machine Learning

This work develops a methodology for sensor placement and dynamic sensor scheduling decisions for digital twins. The digital twin data assimilation is posed as a classification problem, and predictive models are used to train optimal classification trees that represent the map from observed data to estimated digital twin states. In addition to providing a rapid digital twin updating capability, the resulting classification trees yield an interpretable mathematical representation that can be queried to inform sensor placement and sensor scheduling decisions. The proposed approach is demonstrated for a structural digital twin of a 12 ft wingspan unmanned aerial vehicle. Offline, training data are generated by simulating scenarios using predictive reduced-order models of the vehicle in a range of structural states. Furthermore, these training data can be further augmented using experimental or other historical data. In operation, the trained classifier is applied to observational data from the physical vehicle, enabling rapid adaptation of the digital twin in response to changes in structural health. Within this context, we study the performance of the optimal tree classifiers and demonstrate how they enable explainable structural assessments from sparse sensor measurements and also inform optimal sensor placement.

47 OTHER INSTRUMENTATION↗

Fabrication of metal-organic framework thin films for luminescent sensing applications

Metal−organic frameworks (MOFs) have emerged as an exciting material class due to their nearly infinite design space: an inexhaustible combination of metal centers, organic linkers, and reaction conditions may be leveraged to obtained desired optical, physical, and chemical properties. This rich synthetic diversity enables properties such as pore dimensions and functionality to be rationally tailored for highly selective and sensitive detection of target analytes. Luminescent MOF-based sensors in particular offer advantages including low cost, portability, and ease-of-use. Often, performance is maximized by utilizing the luminescent MOF in thin film form, for example by integrating the film onto an optical fiber, yet the synthesis of high-quality MOF thin films often requires tedious, expensive, and/or slow approaches. Here, we demonstrate a rapid, simple strategy for growing copper MOFs using metal oxide templates; the concept is first demonstrated with a well-studied system, copper-1,3,5-benznetricarboxylate (Cu-BTC). Variables such as the choice of solvent, pH, and the choice of the copper salt anion all govern thin film quality. We then extend this method to synthesize a solvent and metal-responsive copper MOF that is particularly effective at detecting aluminum, an economically critical metal, at trace concentrations using a fully portable luminescence spectrometer. Taken together, this work demonstrates a convenient, versatile, and sustainable method for developing high quality MOF thin film-based optical sensors.

Crawford, Scott↗

Irradiation Testing of Sensors - ASI Program Review 2022

This is a powerpoint presentation for the annual Advanced Sensors and Instrumentation (ASI) program webinar. The following is a summary of the presentation. Advanced instrumentation enables testing of nuclear fuels and materials in support of the US advanced nuclear technology industry. A number of promising sensor technologies are in the pipeline. The early part of sensor development can be done outside of the reactor environment, but full technical readiness requires experience gained from in-core performance testing. Customers usually have only one shot to conduct their irradiation experiments. Because of the high costs test sponsors are frequently reluctant to incorporate unproven technologies in reactor experiments. Therefore, it is vital to demonstrate newly-developed sensors in operational conditions, prior to incorporating them into long-term high-value experiments. Successful completion of these activities will create new monitoring capabilities in high-power test reactors (such as ATR) as well as specialty reactors such as TREAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connection between the physicochemical characteristics of amorphous carbon thin films and their electrochemical properties

Connecting a material's surface chemistry with its electrocatalytic performance is one of the major questions in analytical electrochemistry. This is especially important in many sensor applications where analytes from complex media need to be measured. Unfortunately, today this connection is still largely missing except perhaps for the most simple ideal model systems. Here we present an approach that can be used to obtain insights about this missing connection and apply it to the case of carbon nanomaterials. In this paper we show that by combining advanced computational techniques augmented by machine learning methods with x-ray absorption spectroscopy (XAS) and electrochemical measurements, it is possible to obtain a deeper understanding of the correlation between local surface chemistry and electrochemical performance. As a test case we show how by computationally assessing the growth of amorphous carbon (a-C) thin films at the atomic level, we can create computational structural motifs that may in turn be used to deconvolute the XAS data from the real samples resulting in local chemical information. Then, by carrying out electrochemical measurements on the same samples from which x-ray spectra were measured and that were further characterized computationally, it is possible to gain insight into the interplay between the local surface chemistry and electrochemical performance. To demonstrate this methodology, we proceed as follows: after assessing the basic electrochemical properties of a-C films, we investigate the effect of short HNO 3 treatment on the sensitivity of these electrodes towards an inner sphere redox probe dopamine to gain knowledge about the influence of altered surface chemistry to observed electrochemical performance. Overall, these results pave the way towards a more general assessment of electrocatalysis in different systems and provide the first steps towards data driven tailoring of electrode surfaces to gain optimal performance in a given application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress of Tripwire: Multi-Modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Progress of Tripwire: Multi-modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

A systematic study and framework of fringe projection profilometry with improved measurement performance for in-situ LPBF process monitoring

Fringe Projection Profilometry (FPP) is a cost-effective and non-invasive technology that has been shown to measure finer features. Here, in this work, we developed an in-situ FPP method to measure the dynamic topography of powder bed and printed layer during Laser Powder Bed Fusion (LPBF) additive manufacturing (AM) process. A systematic study towards developing a comprehensive framework of LPBF-specific FPP is demonstrated to enhance and evaluate the performance of applying FPP for in-situ LPBF monitoring, including 1) a modified sensor model with localized correction; 2) improved phase unwrapping with FFT filtering 3) quantitative uncertainty analysis; and 4) experimental validation with ex-situ characterization. The developed LPBF-specific FPP system and methods are implemented on a commercial LPBF-AM machine, achieving better accuracy, more robustness, and increased field of view while maintaining sufficient measurement range and decent resolution, in contrast to literature methods. The established FPP framework will facilitate the development of closed-loop control strategies for advancing LPBF based AM.

42 ENGINEERING↗

Polyethylene Glycol Crowder’s Effect on Enzyme Aggregation, Thermal Stability, and Residual Catalytic Activity

Protein stability and performance in various natural and artificial systems incorporating many other macromolecules for therapeutic, diagnostic, sensor, and biotechnological applications attract increasing interest with the expansion of these technologies. Here we address the catalytic activity of lysozyme protein (LYZ) in the presence of a polyethylene glycol (PEG) crowder in a broad range of concentrations and temperatures in aqueous solutions of two different molecular mass PEG samples (Mw = 3350 and 10000 g/mol). The phase behavior of PEG–protein solutions is examined by using dynamic light scattering (DLS) and small-angle X-ray scattering (SAXS), while the enzyme denaturing is monitored by using an activity assay (AS) and circular dichroism (CD) spectroscopy. Molecular dynamic (MD) simulations are used to illustrate the effect of PEG concentration on protein stability at high temperatures. The results demonstrate that LYZ residual activity after 1 h incubation at 80 °C is improved from 15% up to 55% with the addition of PEG. The improvement is attributed to two underlying mechanisms. (i) Primarily, the stabilizing effect is due to the suppression of the enzyme aggregation because of the stronger PEG–protein interactions caused by the increased hydrophobicity of PEG and lysozyme at elevated temperatures. (ii) The MD simulations showed that the addition of PEG to some degree stabilizes the secondary structures of the enzyme by delaying unfolding at elevated temperatures. The more pronounced effect is observed with an increase in PEG concentration. This trend is consistent with CD and AS experimental results, where the thermal stability is strengthened with increasing of PEG concentration and molecular mass. Overall, the results show that the highest stabilizing effect is approached at the critical overlap concentration of PEG.

77 NANOSCIENCE AND NANOTECHNOLOGY↗