The objective of this project is to detect and locate microearthquakes to aid in the characterization of reservoir fracture networks. Accurate identification and mapping of the large numbers of microearthquakes induced in EGS is one technique that provides diagnostic information when determining the location, orientation and length of underground crack systems for use in reservoir development and management applications. Conventional earthquake location techniques often are employed to locate microearthquakes. However, these techniques require labor-intensive picking of individual seismic phase onsets across a network of sensors. For this project we adapt the Matched Field Processing (MFP) technique to the elastic propagation problem in geothermal reservoirs to identify more and smaller events than traditional methods alone.

15 GEOTHERMAL ENERGY↗

Field Demonstration of the Brick Ontology to Scale up the Deployment of ASHRAE Guideline 36 Control Sequences

Many commercial buildings have a vast network of sensors as part of their building automation systems (BAS) that allows opportunities for energy consumption and cost savings by deploying advanced control sequences. However, this resource is often underutilized since BAS are typically programmed with simple control sequences with limited potential to deliver on these opportunities. The recent availability of ASHRAE Guideline 36 (G36) with advanced HVAC control sequences supports control retrofits in existing buildings to unlock much of the savings potential. However, barriers such as the lack of standard naming convention of building assets and data points, proprietary equipment and BAS, and the inherent uniqueness of buildings and their systems prevent building stakeholders from adopting any “plug-and-play” implementation of G36. Instead, control vendors must often undertake the manual and labor-intensive point mapping process to identify a data stream’s functional and spatial relationship within the HVAC system along with other relevant contexts and map it to the new control sequences. The vendor must carry out the point mapping process in each individual building since the mapping is unlikely to port over to another building. Even for the same building, the point mapping process can occur multiple times if various control vendors implement different control retrofits and/or multiple control retrofits happen over the lifecycle of the building. Then, there is the likelihood that G36 control sequences are programmed uniquely to the building, preventing the same implementation from being reused in another. Therefore, this paper presents a field demonstration of how we leveraged the Brick ontology with BACnet, OpenBuildingControl’s Control Description Language (CDL), and open-source support tools to implement scalable and portable advanced building controls. These tools provide standardized semantic descriptions and relationships of the building’s assets and data points (Brick), standardized communication protocol to read from and write to the building’s BAS (BACnet), and standardized code implementations (CDL) of standardized advanced control strategies (G36). We implemented G36’s hot water supply temperature setpoint reset in a Berkeley, CA building for this field demonstration. This field demonstration aims to show how integrating these tools may streamline the deployment of advanced control sequences such as G36 in a consistent manner regardless of differences found across buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model year 2010 Honda insight level-1 testing report.

As a part of the US Department of Energy's Advanced Vehicle Testing Activity (AVTA), a model year 2010 Honda Insight was procured by eTec (Phoenix, AZ) and sent to ANL's Advanced Powertrain Research Facility for the purposes of vehicle-level testing in support of the Advanced Vehicle Testing Activity (AVTA). Data was acquired during testing using non-intrusive sensors, vehicle network information, and facilities equipment (emissions and dynamometer data). Standard drive cycles, performance cycles, steady-state cycles and A/C usage cycles were tested. Much of this data is openly available for download in ANL's Downloadable Dynamometer Database (D3). The major results are shown here in this report. Given the preliminary nature of this assessment, the majority of the testing was done over standard regulatory cycles and seeks to obtain a general overview of how the vehicle performs. These cycles include the US FTP cycle (Urban) and Highway Fuel Economy Test cycle as well as the US06, a more aggressive supplemental regulatory cycle. Data collection for this testing was kept at a fairly high level and includes emissions and fuel measurements from an exhaust emissions bench, high-voltage and accessory current and voltage from a DC power analyzer, and CAN bus data such as engine speed, engine load, and electric machine operation when available. The following sections will seek to explain some of the basic operating characteristics of the MY2010 Insight and provide insight into unique features of its operation and design.

33 ADVANCED PROPULSION SYSTEMS↗

Risk-Informed Monitoring, Verification and Accounting (RI-MVA): An NRAP White Paper Documenting Methods and a Demonstration Model for Risk-Informed MVA System Design and Operations in Geologic Carbon Sequestration

This white paper accompanies a demonstration model that implements methods for the risk-informed design of monitoring, verification and accounting (RI-MVA) systems in geologic carbon sequestration projects. The intent is that this model will ultimately be integrated with, or interfaced with, the National Risk Assessment Partnership (NRAP) integrated assessment model (IAM). The RI-MVA methods described here apply optimization techniques in the analytical environment of NRAP risk profiles to allow systematic identification and comparison of the risk and cost attributes of MVA design options.

carbon sequestration↗

Software-Defined Solutions for Managing Energy Use in Small to Medium Sized Commercial Buildings

The Project uses state-of-the-art computer science to extend the benefits of Building Automation Systems (BAS) typically found in large buildings (>100,000 square foot) to medium-sized commercial buildings (<50,000 sq ft). The BAS developed in this project, termed OpenBAS, uses an open-source and open software architecture platform, user interface, and plug-and-play control devices to facilitate adoption of energy efficiency strategies in the commercial building sector throughout the United States. At the heart of this “turn key” BAS is the platform with three types of controllers—thermostat, lighting controller, and general controller—that are easily “discovered” by the platform in a plug-and-play fashion. The user interface showcases the platform and provides the control system set-up, system status display and means of automatically mapping the control points in the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mortandad Canyon seismic modeling (Progress Report)

The goal of this project is to assess site amplification for LANL through modeling of site and topography effects. Such assessment is difficult due to the lack of data documenting site effects for large normal faulting earthquakes such as the Pajarito Fault System that was found to be governing the seismic hazard at LANL. LANL site is also characterized by unique geologic settings, a series of mesa at the edge of the huge volcanic complex of the Jemez caldera. The latter has produced a series of successive and intertwined deposits of volcanic flow and sedimentary layer. Such layering of material with different elastic properties is expected to create large amplification effects magnified further by the presence at the surface of tuff materials. In 2014, a seismic campaign was performed in the Mortandad Canyon with a network of sensors on and near a local mesa. That campaign was designed to provide experimental data to estimation and prediction of amplification and site effects at LANL. An analysis on the seismic noise records of that campaign shows evidence of amplification of the seismic amplitude for the stations on the top of the mesa. Our goal is to reproduce the effect observed (both retrieving the resonance frequencies and amplification levels). We also plan to test if amplification effects observed for seismic noise can be extended to shaking produced by earthquakes. We are using a 3D modeling tool based on the Spectral Element Method (SEM) that is a particular type of high-order finite element modeling. Two types of seismic sources will be considered: (1) earthquakes for purpose of seismic hazard evaluation, (2) ambient noise. We show 2 series of numerical computations: (1) seismic waves are generated by random sources to simulate ambient noise. (2) seismic waves are planar waves to simulate a distant earthquake. We plan in the future to model rupture scenario on the Pajarito Fault System.

58 GEOSCIENCES↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Erratum to: Data Fusion to Support Integrated Nuclear Detonation Detection [Slides]

The original document (LA-UR-22-29547) contained minor equation errors that approximate correct equations that couple the multi-sensor, serial system detector thresholds for a seismic Rayleigh wave detector and an acoustic energy detector. Those errors appeared on slides 62-67. This erratum associates the following slides with the erroneous slides. The numbers of the erroneous slides are marked at the upper right in small text in orange. A result of those errors over-predict the performance of the two-sensor serial network, that is, the former document provides an optimistic estimate of system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Characterization of Hyper-Local Atmospheric Greenhouse Gas Sources

Atmospheric greenhouse gas (GHG) emissions are often characterized using stationary, tower-based sensors. Ground based sensors reside in the turbulent boundary layer and are subject to intense concentration impulses from hyper-local (<100m) point sources of emissions. These high frequency spikes are often filtered out in broader emission flux studies, losing valuable information about how hyper-local sources influence receptors. In this study, we investigated how empirical atmospheric data can be used to locate and quantify a concurrently measured hyper-local point source in a dense urban setting. An eddy covariance style tower and a low-cost sensor tower were deployed in various locations around an urban, hyper-local CO2/CH4 emissions source (a continuously measured restaurant exhaust vent). A model using different processing and statistical techniques was built to examine the most effective procedures for source isolation, directional location, and emission quantification. Using excess concentrations above a minimum baseline, we identify the source using bivariate polar plots and quantify the relationship between source size, receptor distance, and statistical proxies. Furthermore, we find that varying statistical thresholds allows for identification of less influential sources which are drowned out by larger or closer sources. Finally, we show that large sources can be effectively characterized using low-cost sensors, a valuable outcome informing how networks for monitoring larger areas could be implemented. This work may provide a basis for source identification and monitoring protocols for networks that feature sensors influenced by hyper-local point sources, subject to site-specific assumptions.

54 ENVIRONMENTAL SCIENCES↗

A multi-Physics Experiment for Low-Yield Nuclear Explosion Monitoring

A series of multi-physics experiments, referred to as Physics Experiment 1 (PE1) is underway at the United States’ Nevada National Security Site (NNSS). The PE1 series includes detonations of three underground chemical explosions in P-tunnel, with fully coupled (PE1 A), partially decoupled (PE1 D L ), and fully decoupled (PE1 B) emplacements. Canisters with gas tracers are imbedded in the explosives, and the tracers are released when the canister is destroyed by the detonation. A dedicated electromagnetic (EM) experiment (EMX) generates well-characterized EM signals at an underground location near the chemical explosive experiments. A series of atmospheric experiments (METEX, REACT, and METREX) release smoke and radioactive tracers around Aqueduct Mesa to test gas transport in complex topography. Each of the chemical explosive experiments includes a network of sensors to record seismic, acoustic, and electromagnetic waves, measurement of atmospheric conditions, and air sample collection for measurement of tracer concentration. EMX records EM signals underground and on the surface of Aqueduct Mesa. METEX, REACT, and METREX include measurement of atmospheric condition, as well as tracking smoke releases. REACT and METREX add low-level radioactive gas tracers to the atmospheric releases.

58 GEOSCIENCES↗

Application of Ensemble Sensitivity Analysis to Observation Targeting for Short-term Wind Speed Forecasting

The operators of electrical grids, sometimes referred to as Balancing Authorities (BA), typically make critical decisions on how to most reliably and economically balance electrical load and generation in time frames ranging from a few minutes to six hours ahead. At higher levels of wind power generation, there is an increasing need to improve the accuracy of 0- to 6-hour ahead wind power forecasts. Forecasts on this time scale have typically been strongly dependent on short-term trends indicated by the time series of power production and meteorological data from a wind farm. Additional input information is often available from the output of Numerical Weather Prediction (NWP) models and occasionally from off-site meteorological towers in the region surrounding the wind generation facility. A widely proposed approach to improve short-term forecasts is the deployment of off-site meteorological towers at locations upstream from the wind generation facility in order to sense approaching wind perturbations. While conceptually appealing, it turns out that, in practice, it is often very difficult to derive significant benefit in forecast performance from this approach. The difficulty is rooted in the fact that the type, scale, and amplitude of the processes controlling wind variability at a site change from day to day if not from hour to hour. Thus, a location that provides some useful forecast information for one time may not be a useful predictor a few hours later. Indeed, some processes that cause significant changes in wind power production operate predominantly in the vertical direction and thus cannot be monitored by employing a network of sensors at off-site locations. Hence, it is very challenging to determine the type of sensors and deployment locations to get the most benefit for a specific short-term forecast application. Two tools recently developed in the meteorological research community have the potential to help determine the locations and parameters to measure in order to get the maximum positive impact on forecast performance for a particular site and short-term look-ahead period. Both tools rely on the use of NWP models to assess the sensitivity of a forecast for a particular location to measurements made at a prior time (i.e. the look-ahead period) at points surrounding the target location. The fundamental hypothesis is that points and variables with high sensitivity are good candidates for measurements since information at those points are likely to have the most impact on the forecast for the desired parameter, location and look-ahead period. One approach is called the adjoint method (Errico and Vukicevic, 1992; Errico, 1997) and the other newer approach is known as Ensemble Sensitivity Analysis (ESA; Ancell and Hakim 2007; Torn and Hakim 2008). Both approaches have been tested on large-scale atmospheric prediction problems (e.g. forecasting pressure or precipitation over a relatively large region 24 hours ahead) but neither has been applied to mesoscale space-time scales of winds or any other variables near the surface of the earth. A number of factors suggest that ESA is better suited for short-term wind forecasting applications. One of the most significant advantages of this approach is that it is not necessary to linearize the mathematical representation of the processes in the underlying atmospheric model as required by the adjoint approach. Such a linearization may be especially problematic for the application of short-term forecasting of boundary layer winds in complex terrain since non-linear shifts in the structure of boundary layer due to atmospheric stability changes are a critical part of the wind power production forecast problem. The specific objective of work described in this paper is to test the ESA as a tool to identify measurement locations and variables that have the greatest positive impact on the accuracy of wind forecasts in the 0- to 6-hour look-ahead periods for the wind generation area of California's Tehachapi Pass during the warm (high generation) season. The paper is organized as follows. Section 2 highlights the methodology, Section 3 presents results, and Section 4 concludes with a summary and brief discussion of future work.

17 WIND ENERGY↗

Model year 2010 (Gen 3) Toyota Prius level 1 testing report.

As a part of the US Department of Energy's Advanced Vehicle Testing Activity (AVTA), a model year 2010 Toyota Prius (Generation 3) was procured by eTec (Phoenix, AZ) and sent to ANL's Advanced Powertrain Research Facility for the purposes of 'Level 1' testing in support of the Advanced Vehicle Testing Activity (AVTA). Data was acquired during testing using non-intrusive sensors, vehicle network connection, and facilities equipment (emissions and dynamometer data). Standard drive cycles, performance cycles, steady-state cycles and A/C usage cycles were conducted. Much of this data is openly available for download in ANL's Downloadable Dynamometer Database (D{sup 3}). The major results are shown here in this report. Given the preliminary nature of this assessment, the majority of the testing was done over standard regulatory cycles and seeks to obtain a general overview of how the vehicle performs. These cycles include the US FTP cycle (Urban) and Highway Fuel Economy Test cycle as well as the US06, a more aggressive supplemental regulatory cycle. Data collection for this testing was kept at a fairly high level and includes emissions and fuel measurements from the exhaust emissions bench, high-voltage and accessory current and voltage from a DC power analyzer, and minimal CAN bus data such as engine speed and pedal position. The following sections will seek to explain some of the basic operating characteristics of the MY2010 Prius over standard regulatory cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Model year 2010 Ford Fusion Level-1 testing report.

As a part of the US Department of Energy's Advanced Vehicle Testing Activity (AVTA), a model year 2010 Ford Fusion was procured by eTec (Phoenix, AZ) and sent to ANL's Advanced Powertrain Research Facility for the purposes of vehicle-level testing in support of the Advanced Vehicle Testing Activity. Data was acquired during testing using non-intrusive sensors, vehicle network information, and facilities equipment (emissions and dynamometer). Standard drive cycles, performance cycles, steady-state cycles, and A/C usage cycles were conducted. Much of this data is openly available for download in ANL's Downloadable Dynamometer Database. The major results are shown in this report. Given the benchmark nature of this assessment, the majority of the testing was done over standard regulatory cycles and sought to obtain a general overview of how the vehicle performs. These cycles include the US FTP cycle (Urban) and Highway Fuel Economy Test cycle as well as the US06, a more aggressive supplemental regulatory cycle. Data collection for this testing was kept at a fairly high level and includes emissions and fuel measurements from an exhaust emissions bench, high-voltage and accessory current/voltage from a DC power analyzer, and CAN bus data such as engine speed, engine load, and electric machine operation. The following sections will seek to explain some of the basic operating characteristics of the MY2010 Fusion and provide insight into unique features of its operation and design.

33 ADVANCED PROPULSION SYSTEMS↗

Marine renewable energy for Arctic observations

Arctic observations are becoming increasingly valuable as researchers investigate climate change and its associated concerns, such as decreasing sea ice and increasing ship traffic. Networks of sensors with frequent sampling capabilities are needed to run forecast models, improve navigation, and inform climate research. Sampling frequency and deployment duration are currently constrained by battery power limitations. In-situ power generation using marine renewable energy sources such as waves and currents can be used to circumvent this constraint. Wave and current resources vary spatially and temporally in the Arctic, with some locations and seasons being better suited for marine renewable energy power generation. Locations and seasons with small resources may still be able to use marine renewable energy because of the low power requirements of the instruments. In this study, we describe the wave and current resources in the Arctic, outline the electricity generation developments that are needed to utilize the resources, and suggest use cases. Wave and current energy converters developed to power observations in the Arctic could also be used to power observations at lower latitudes. Marine renewable energy has the potential to decrease dependence on batteries and improve data collection capabilities in the Arctic; however, this would require the development of new low power technologies that can operate in extreme Arctic environments.

16 TIDAL AND WAVE POWER↗

Local Weather Station Design and Development for Cost-Effective Environmental Monitoring and Real-Time Data Sharing

Current weather monitoring systems often remain out of reach for small-scale users and local communities due to their high costs and complexity. This paper addresses this significant issue by introducing a cost-effective, easy-to-use local weather station. Utilizing low-cost sensors, this weather station is a pivotal tool in making environmental monitoring more accessible and user-friendly, particularly for those with limited resources. It offers efficient in-site measurements of various environmental parameters, such as temperature, relative humidity, atmospheric pressure, carbon dioxide concentration, and particulate matter, including PM 1, PM 2.5, and PM 10. The findings demonstrate the station’s capability to monitor these variables remotely and provide forecasts with a high degree of accuracy, displaying an error margin of just 0.67%. Furthermore, the station’s use of the Autoregressive Integrated Moving Average (ARIMA) model enables short-term, reliable forecasts crucial for applications in agriculture, transportation, and air quality monitoring. Furthermore, the weather station’s open-source nature significantly enhances environmental monitoring accessibility for smaller users and encourages broader public data sharing. With this approach, crucial in addressing climate change challenges, the station empowers communities to make informed decisions based on real-time data. In designing and developing this low-cost, efficient monitoring system, this work provides a valuable blueprint for future advancements in environmental technologies, emphasizing sustainability. The proposed automatic weather station not only offers an economical solution for environmental monitoring but also features a user-friendly interface for seamless data communication between the sensor platform and end users. This system ensures the transmission of data through various web-based platforms, catering to users with diverse technical backgrounds. Furthermore, by leveraging historical data through the ARIMA model, the station enhances its utility in providing short-term forecasts and supporting critical decision-making processes across different sectors.

54 ENVIRONMENTAL SCIENCES↗

AEPF: Attention-Enabled Point Fusion for 3D Object Detection

Current state-of-the-art (SOTA) LiDAR-only detectors perform well for 3D object detection tasks, but point cloud data are typically sparse and lacks semantic information. Detailed semantic information obtained from camera images can be added with existing LiDAR-based detectors to create a robust 3D detection pipeline. With two different data types, a major challenge in developing multi-modal sensor fusion networks is to achieve effective data fusion while managing computational resources. With separate 2D and 3D feature extraction backbones, feature fusion can become more challenging as these modes generate different gradients, leading to gradient conflicts and suboptimal convergence during network optimization. To this end, we propose a 3D object detection method, Attention-Enabled Point Fusion (AEPF). AEPF uses images and voxelized point cloud data as inputs and estimates the 3D bounding boxes of object locations as outputs. An attention mechanism is introduced to an existing feature fusion strategy to improve 3D detection accuracy and two variants are proposed. These two variants, AEPF-Small and AEPF-Large, address different needs. AEPF-Small, with a lightweight attention module and fewer parameters, offers fast inference. AEPF-Large, with a more complex attention module and increased parameters, provides higher accuracy than baseline models. Experimental results on the KITTI validation set show that AEPF-Small maintains SOTA 3D detection accuracy while inferencing at higher speeds. AEPF-Large achieves mean average precision scores of 91.13, 79.06, and 76.15 for the car class’s easy, medium, and hard targets, respectively, in the KITTI validation set. Results from ablation experiments are also presented to support the choice of model architecture.

Chemistry↗

JHU Baltimore iButton data

Temperature and Relative Humidity data from a low cost sensor ("iButton") network deployed in Baltimore in summer 2015, 2016, 2017, 2021, and 2022. Initial deployment described in Scott, A., Zaitchik, B., Waugh, D., O'Meara, K. 2017. Intra-Urban temperature variability in Baltimore. Journal of Applied Meteorology and Climatology, 56(1): 159-171. doi: 10.1175/JAMC-D-16-0232.1

applied meteorology↗