Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift dis tance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high and low-energy events. Using point-like energy deposits from 83m Kr calibration electron captures (E ~ 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E ≥ 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q ββ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial measurement of reactor antineutrino oscillation at SNO+

The SNO+ collaboration reports its first spectral analysis of long-baseline reactor antineutrino oscillation using 114 tonne-years of data. Fitting the neutrino oscillation probability to the observed energy spectrum yields constraints on the neutrino mass-squared difference Δ$m^2_{21}$. In the ranges allowed by previous measurements, the best-fit Δ$m^2_{21}$ is ($8.85^{+1.10}_{-1.33}$) × 10 -5 eV 2 . This measurement is continuing in the next phases of SNO+ and is expected to surpass the present global precision on Δ$m^2_{21}$ with about three years of data. In the following, we first describe the configuration of the SNO+ detector when it was partially filled with scintillator, and a characterization of the detector response using intrinsic radioactivity. Next, we detail the event selection and expectations for reactor IBDs and (α, n) reactions. Then, we present the results of an energy spectrum analysis using 114 tonne-years of data. We conclude with prospects of future results from the SNO+ detector, which has been operating fully-filled with 780 tonnes of scintillator

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Liquid Argon Time-Projection Chamber Readouts

Liquid argon time-projection chambers (LArTPCs) have become a prominent tool for experiments in particle physics. Recent years have yielded significant advances in the techniques used to capture the signals generated by these cryogenic detectors. This article summarizes these novel developments for detection of ionization electrons and scintillation photons in LArTPCs. New methods to capture ionization signals address the challenges of scaling traditional techniques to the large scales necessary for future experiments. Pixelated readouts improve signal fidelity and expand the applicability of LArTPCs to higher-rate environments. Methods that leverage amplification in argon enable measurements in the keV regime and below. Techniques to enhance collection of argon scintillation photons improve calorimetry and expand the physics program for very large detectors. Future efforts aim to demonstrate systems for the combined detection of both electrons and photons.

43 PARTICLE ACCELERATORS↗

Feynman-α analysis using BGO gamma-ray detector in UTR-KINKI reactor

In conventional reactor noise measurement based on neutron detection, a neutron detector must be placed as close to a core as possible, to observe a largest possible correlation amplitude. For most of reactors other than critical assemblies, however, the placement is hardly possible. We focused on an alternative reactor noise measurement using prompt gamma-rays having a long flight range, to overcome the above constraint. A Feynman-α analysis using a NaI(Tl) scintillation detector was previously performed in UTR-KINKI, however, white noise originating from radioactivation of the scintillator significantly degraded the correlation amplitude. In this study, another Feynman-α analysis using a BGO gamma-ray detector, which never suffers from any radioactivation, is performed. A series of Feynman-α analyses for a critical state and several subcritical states of UTR-KINKI reactor has been carried out using two BGO detectors and a BF{sub 3} neutron detector to determine prompt-neutron decay constant. In the present analysis, the dead-time effect of these detectors and the delayed-neutron effect are considered. The prompt-neutron decay constant determined from Feynman-α analysis based on gamma-ray detection agrees with that from the analysis based on neutron detection. The Feynman-α analysis based on detecting gamma rays appears to be able to determine prompt-neutron decay constant at least as efficiently as the conventional analysis detecting neutrons.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Changes in Molten Salt Fuel and/or Waste Stream Compounds Cs 2 UCl 6 and Cs 2 UO 2 Cl 4 from Room Temperature to Melting and Related Materials [Slides]

Perovskite phases have been explored in recent literature as waste forms for long term storage of radioactive waste from molten salt reactors specifically. Synthesis of new halide perovskite phases can inform these efforts as well as molten salt reactor chemistry in general. Inorganic perovskites have also shown promise as new scintillating materials for detection of X-rays and gamma rays. Modifying the structure and chemistry of these compounds, perhaps with organic components, could be used to synthesize new scintillating compounds or modify the properties of existing ones. Both U 6+ and U 4+ readily form compounds with a striking similarity to vacancy ordered perovskites (Cs 2 UO 2 Cl 4 and Cs 2 UCl 6 ). Each of these compounds is relevant to molten salt reactor chemistry and/or waste streams. These phases could from in uranium chloride salt systems or waste streams: Cs being a fission product.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ANNIE: the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a Gadolinium-loaded water Cherenkov detector placed in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory, USA. The primary physics goal of ANNIE is to perform neutrino cross-section measurements that will constrain systematic uncertainties in the next generation of long-baseline neutrino experiments. The first measurement will be the multiplicity of final-state neutrons from neutrino-nucleus interactions in water. Alongside these measurements, ANNIE has achieved the first ever deployments of two novel detector technologies in a neutrino beam: Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillator (WbLS). LAPPDs are micro-channel-plate-based devices that provide timing resolution of ~100 picoseconds and sub-centimeter spatial resolution. WbLS combines the low attenuation and Cherenkov production of pure water with the high light-yield and low detection threshold of liquid scintillator. This talk will discuss the status of ANNIE's physics and R&D measurements.

43 PARTICLE ACCELERATORS↗

Demonstrating Safeguards Applications of DRiFT Gas Detector Capabilities [Slides]

DRiFT, a Detector Response Function Toolkit, post-processes MCNP output to model detector response. Three primary components: scintillator (focus of FY 21 TED work), gas detectors (focus of this FY), and semiconductor detectors. Capability to model scintillator detectors has previously been demonstrated.

47 OTHER INSTRUMENTATION↗

Physics Potential of a Future Large n Detector in Korea

The demand for underground labs for neutrino and rare event search experiments has been increasing over the last few decades. Yemilab, constructed in October 2022, is the first deep (1~km) underground lab dedicated to science in Korea, where a large cylindrical cavern (D: 20~m, H: 20~m) was excavated in addition to the main caverns and halls. The large cavern could be utilized for a low background neutrino experiment by a liquid scintillator-based detector (LSC) where a 2.26 kiloton LS target would be filled.It's timely to have such a large but ultra-pure LS detector after the shutdown of the Borexino experiment so that solar neutrinos can be measured much more precisely. Interesting BSM physics searches can be also pursued with this detector when it's combined with an electron linac, a proton cyclotron (IsoDAR source), or a radioactive source. This talk discusses the concept of a candidate detector and the physics potential of a large liquid scintillator detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Towards Three-Dimensional Neutron Imaging with Light-field Technology

A broad range of applications in nuclear safeguards and security can benefit from compact, fast neutron imagers with large angular acceptance. However, accurate 3D multi-vertex reconstruction in a monolithic detector remains a significant barrier to realization. Current approaches, such as the centroiding approach and the use of shadow masks, have not yet resulted in a successful demonstration in a light-starved environment. This project explored the use of cutting-edge technology—a light field camera—which inherently preserves both the spatial and directional information of incident light. Such technology can, in principle, resolve multi-vertex events and offer accurate position reconstruction in 3D with relatively simple readout electronics. Since the project's inception in May 2023, we have built an experimental setup to calibrate and characterize a commercial light-field camera (Lytro Illum). We assessed its 3D event reconstruction capability in a relatively low-light intensity environment by analyzing the cross-correlation of a series of 2D images of a characterized tunable light source taken at various distances. A sub-cm resolution, lower than typical neutron interaction separations in a compact scintillator volume, was observed with the LED light source, suggesting the promising capability of its nominal optics design to provide the adequate resolution required for a compact monolithic neutron directional detector. However, using a light-field-based readout for a neutron camera requires incorporating an ultra-low-noise light sensor, which is beyond the scope of this project. We also initiated the development of a 3D light-field-based reconstruction algorithm tailored to sparse scenes, as expected from particle interactions in a scintillator medium. Additionally, we demonstrated the capability of the algorithm to replicate the ground truth. Finally, we began the development of a neutron directional detector simulation to determine the performance criteria for light-field-based reconstruction that allows for good neutron directional reconstruction. This Feasibility Study has led to a successful follow-up project under the DNN R&D innovation portfolio starting May 2024.

42 ENGINEERING↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Design and Characterization of a Lens-Coupled System for Dynamic X-Ray Diffraction

X-ray diffraction (XRD) is a necessary technique for understanding states of materials under static and dynamic loading conditions. The higher-pressure Equation of State (EOS) of many materials can only be explored via shock or ramp compression at temperatures and pressures of interest. While static XRD work has yielded EOS measurements in the 100 - 200 GPa regime, dynamic X-ray diffraction (DXRD) can explore EOS phases in the TPa regime, which closely resembles inner-core planetary conditions. DXRD hinges on the ability to measure the exact phase or phase change of a material while under dynamic loading conditions. Macroscopic diagnostic systems (e.g. velocimetry and pyrometry) can infer a phase change but not identify the specific phase entered by a material. While microscopic (atomic-level) diagnostic systems (e.g. DXRD) have been designed and implemented in Department of Energy’s (DOE) National Laboratories complex, the unique nature of Sandia National Laboratories’ Pulsed Power Facility (Z Machine) prohibits the use of such devices. The destructive nature of Z experiments presents a challenge to data capture and retrieval. Furthermore there are electromagnetic interference, X-ray background, and mechanical constraints to consider. Thus, a multi-part X-ray diagnostic for use on the Z Machine and Z-Beamlet Laser system has been designed and analyzed. Portions of this new DYnamic SCintillator Optic (DYSCO) have been built, tested and fielded. A data analysis software has been written. Finally, the radiance profile of the DYSCO’s scintillator has been characterized through experiments performed at the University of Arizona.

36 MATERIALS SCIENCE↗