At least 721 records · Page 40

Assessment and Non-Destructive Evaluation of the Influence of Residual Solvent on a Two-Part Epoxy-Based Adhesive Using Ultrasonics

Polymers are increasingly being used in higher demanding applications due to their ability to tailor the properties of structures while allowing for a weight and cost reduction. Solvents play an important role in the manufacture of polymeric structures since they allow for a reduction in the polymer’s viscosity or assist with the dispersion of fillers into the polymer matrix. However, the incorrect removal of the solvent affects both the physical and chemical properties of polymeric materials. The presence of residual solvent can also negatively affect the curing kinetics and the final quality of polymers. Destructive testing is mainly performed to characterize the properties of these materials. However, this type of testing involves using lab-type equipment that cannot be taken in-field to perform in situ testing and requires a specific sample preparation. Here, a method is presented to non-destructively evaluate the curing process and final viscoelastic properties of polymeric materials using ultrasonics. In this study, changes in longitudinal sound speed were detected during the curing of an aerospace epoxy adhesive as a result of variations in polymer chemistry. To simulate the presence of residual solvent, samples containing different weight percentages of isopropyl alcohol were manufactured and tested using ultrasonics. Thermogravimetric analysis was used to show changes in the decomposition of the adhesive due to the presence of IPA within the polymer structure. Adding 2, 4, and 6 wt.% of IPA decreased the adhesive’s lap shear strength by 40, 58, and 71%, respectively. Ultrasonics were used to show how the solvent influenced the curing process and the final sound speed of the adhesive. Young’s modulus and Poisson’s ratio were determined using both the longitudinal and shear sound speeds of the adhesive. Using ultrasonics has the potential to non-invasively characterize the quality of polymers in both an in-field and manufacturing settings, ensuring their reliability during use in demanding applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assimilating partial observation to enhance feedback control of stochastic dynamical systems

Here, in this paper, we present a novel methodology to tackle feedback optimal control problems in scenarios where the exact state of the controlled process is unknown. It integrates data assimilation techniques and optimal control solvers to manage partial observation of the state process, a common occurrence in practical scenarios. Traditional stochastic optimal control methods assume full state observation, which is often not feasible in real-world fluid dynamics control problems. Our approach underscores the significance of utilizing observational data to inform control policy design. Specifically, we introduce a kernel learning backward stochastic differential equation (SDE) filter to enhance data assimilation efficiency and propose a sample-wise stochastic optimization method within the stochastic maximum principle framework. We demonstrate the efficacy and accuracy of our method in the control of advection-diffusion-reaction flow problem and the Dubins airplane maneuvering problem with model uncertainty.

data driven↗

Performance of methods for SARS-CoV-2 variant detection and abundance estimation within mixed population samples

The accurate identification of SARS-CoV-2 (SC2) variants and estimation of their abundance in mixed population samples (e.g., air or wastewater) is imperative for successful surveillance of community level trends. Assessing the performance of SC2 variant composition estimators (VCEs) should improve our confidence in public health decision making. Here, we introduce a linear regression based VCE and compare its performance to four other VCEs: two re-purposed DNA sequence read classifiers (Kallisto and Kraken2), a maximum-likelihood based method (Lineage deComposition for Sars-Cov-2 pooled samples (LCS)), and a regression based method (Freyja). We simulated DNA sequence datasets of known variant composition from both Illumina and Oxford Nanopore Technologies (ONT) platforms and assessed the performance of each VCE. We also evaluated VCEs performance using publicly available empirical wastewater samples collected for SC2 surveillance efforts. Bioinformatic analyses were performed with a custom NextFlow workflow (C-WAP, CFSAN Wastewater Analysis Pipeline). Relative root mean squared error (RRMSE) was used as a measure of performance with respect to the known abundance and concordance correlation coefficient (CCC) was used to measure agreement between pairs of estimators. Based on our results from simulated data, Kallisto was the most accurate estimator as it had the lowest RRMSE, followed by Freyja. Kallisto and Freyja had the most similar predictions, reflected by the highest CCC metrics. We also found that accuracy was platform and amplicon panel dependent. For example, the accuracy of Freyja was significantly higher with Illumina data compared to ONT data; performance of Kallisto was best with ARTICv4. However, when analyzing empirical data there was poor agreement among methods and variations in the number of variants detected (e.g., Freyja ARTICv4 had a mean of 2.2 variants while Kallisto ARTICv4 had a mean of 10.1 variants). This work provides an understanding of the differences in performance of a number of VCEs and how accurate they are in capturing the relative abundance of SC2 variants within a mixed sample (e.g., wastewater). Such information should help officials gauge the confidence they can have in such data for informing public health decisions.

60 APPLIED LIFE SCIENCES↗

Parts-Per-Million Carbonate Mineral Quantification with Thermogravimetric Analysis–Mass Spectrometry

Mitigating the deleterious effects of climate change requires the development and implementation of carbon capture and storage technologies. To expand the monitoring, verification, and reporting (MRV) capabilities of geologic carbon mineralization projects, we developed a thermogravimetric analysis–mass spectrometry (TGA–MS) methodology to enable quantification of <100 ppm calcite (CaCO 3 ) in complex samples. We extended TGA–MS calcite calibration curves to enable a higher measurement resolution and lower limits of quantification for evolved CO 2 from a calcite–corundum mixture. We demonstrated <100 ppm carbonate mineral quantification with TGA–MS for the first time, an outcome applicable across earth, environmental, and materials science fields. We applied this carbonate quantification method to a suite of Columbia River Basalt Group (CRBG) well cuttings recovered in 2009 from Pacific Northwest National Laboratory’s Wallula #1 Well. Our execution of this new combined calcite and calcite–corundum calibration curve TGA–MS method on our CRBG sample suite indicated average carbonate contents of 0.050 wt % in flow interiors (caprocks) and 0.400 wt % in interflow zones (reservoirs) in the upper 1250 m of the Wallula #1 Well. Finally, by advancing our knowledge of continental flood basalt-hosted carbonates in the mafic subsurface and reaching new TGA–MS quantification limits for carbonate minerals, we expand MRV capabilities and support the commercial-scale deployment of carbon mineralization projects in the Pacific Northwest United States and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An improved method for uranium separation from urine for rapid bioassay by inductively coupled plasma mass spectrometry

Bioassay monitoring is an important capability for any facility that works with significant amounts of radioactive material. The speed at which these analyses can be made is critical in the event of a potential exposure. Here, we present a new method that facilitates the rapid separation of uranium from a urine matrix for assay and isotopic determination by inductively coupled plasma mass spectrometry. This method is validated with archived urine samples that were previously analyzed using established, more time consuming methods. The sources of uncertainty for uranium assay and isotopic measurements are modelled using the Monte Carlo method to better understand the precision and accuracy of this method at the limit of quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Enhanced resonant ultrasound spectroscopy for measurement of the elastic properties of multi-material systems

Understanding the elastic properties of materials is critical for their safe incorporation and predictable performance. Current methods of bulk elastic characterization often have notable limitations for in situ structural applications, with usage restricted to simple geometries and material distributions. To address these existing issues, this study sought to expand the capabilities of resonant ultrasound spectroscopy (RUS), an established nondestructive evaluation method, to include the characterization of isotropic multi-material samples. In this work, finite-element-based RUS analysis consisted of numerical simulations and experimental testing of composite samples comprised of material pairs with varying elasticity and density contrasts. Utilizing genetic algorithm inversion and mode matching, our results demonstrate that elastic properties of multi-material samples can be reliably identified within several percent of known or nominal values using a minimum number of identified resonance modes, given sample mass is held consistent. The accurate recovery of material properties for composite samples of varying material similarity and geometry expands the pool of viable samples for RUS and advances the method towards in situ inspection and evaluation.

36 MATERIALS SCIENCE↗

Autosampler software

control software for an automated liquid chromatography sample injection and separation system. It is related to a PNNL invention report 31630-E, Method for direct delivering trace samples from smallsize wells to liquid chromatography and mass spectrometry. The main purpose of the control software is to enable automated sample injection from a nanowell device.

Liyu, Andrey↗

Deep Learning for Rapid Analysis of Spectroscopic Ellipsometry Data

High‐throughput experimental approaches to rapidly develop new materials require high‐throughput data analysis methods to match. Spectroscopic ellipsometry is a powerful method of optical properties characterization, but for unknown materials and/or layer structures the data analysis using traditional methods of nonlinear regression is too slow for autonomous, closed‐loop, high‐throughput experimentation. Herein, three methods (termed spectral, piecewise, and pointwise) of spectroscopic ellipsometry data analysis based on deep learning are introduced and studied. After initial training, the incremental time for inferring optical properties can be a thousand times faster than traditional methods. Results for multilayer sample structures with optically isotropic materials are presented, appropriate for high‐throughput studies of thin films of phase‐change materials such as GeSbTe (GST) alloys. Results for studies on highly birefringent layered materials are also presented, exemplified by the transition metal dichalcogenide MoS 2 . How the materials under test and the experimental objectives may guide the choice of analysis methods are discussed. The utility of our approach is demonstrated by analyzing data measured on a composition spread of GeSbTe phase‐change alloys containing 177 distinct compositions, and identifying the composition with optimal phase‐change figure of merit in only 1.4 s of analysis time.

Li, Yifei↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

Large-Volume Injection and Assessment of Reference Standards for n -Alkane δD and δ 13 C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry

Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ 13 C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision. We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ 13 C and δD measurements of n-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct n-alkane δD and δ13C measurements. The mean precision of the δD method based on 233 environmental n-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ 13 C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of n-alkane standards with large offsets in δD values in adjacent n-alkane chains can lead to biases in measurement correction. The large-volume injection method shows good reproducibility of δ 13 C and δD measurements of n-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent n-alkane chains, to minimize memory effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Caution on Using Tetrahydrofuran for Processing Crystalline Silica Samples From Engineered Stone for XRD Analysis

Abstract We conducted laboratory experiments to investigate a suspected effect of tetrahydrofuran (THF) on quantifying crystalline silica in samples collected from working with engineered stone when THF is used to process samples prior to the X-ray diffraction (XRD) analysis. Two groups of samples from grinding either engineered stone or granite were simultaneously taken from a laboratory testing system, with one group of samples using THF for processing and another group using muffle furnace for ashing. For each stone type, we also tested four levels of respirable dust loading on the samples by varying the grinding time from 1 to 8 min. Statistical analysis of the experimental results on crystalline silica contents of the two groups of samples showed that the difference between the two methods was not significant (P ≥ 0.05) for the granite at all four levels of respirable dust loading and for the engineered stone at the two levels of respirable dust loading greater than 0.5 mg. However, the crystalline silica content from using THF processing was significantly lower (P = 0.001) than that from using muffle furnace ashing for engineered stone when the respirable dust loading levels were less than 0.5 mg. For the engineered stone dust samples with grinding times of 1 and 2 min, the average respirable dust loading was about 0.19 and 0.34 mg, respectively; while the crystalline silica content from using THF processing was 30.9 and 21.5% lower than that from using muffle furnace ashing, respectively. Since most full-shift samples from field assessments in this industry are expected to have respirable dust loading less than 0.5 mg, muffle furnace or radio frequency plasma ashing should be specified as the preferred sample processing method instead of the THF processing method for quantification of crystalline silica when engineered stone is expected to present to avoid artificially reduced silica content values, which are likely caused by the reactions between THF and the resins in engineered stone.

Public, Environmental & Occupational Health↗

Understanding Measurement Artifacts Causing Inherent Cation Gradients in Depth Profiles of Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from the hybrid organic-inorganic perovskite solar cells (PSCs) in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). We have very recently developed thermo-mechanical methods to cleave perovskite samples at the back transparent conducting oxide/PSC interface. This allowed for depth-profiling from the back of the device to the front. The resultant profiles answered the lingering question of the apparent A-site cation gradient typically seen in TOF-SIMS depth profiles. In fact, this gradient is a measurement artifact due to beam damage that the community should be informed of as TOF-SIMS data become more commonly employed. Methods of mitigating this artifact by altering the measurement conditions are also presented.

14 SOLAR ENERGY↗

Discrete-Direct Model Calibration and Uncertainty Propagation Method Confirmed on Multi-Parameter Plasticity Model Calibrated to Sparse Random Field Data

A discrete direct (DD) model calibration and uncertainty propagation approach is explained and demonstrated on a 4-parameter Johnson-Cook (J-C) strain-rate dependent material strength model for an aluminum alloy. The methodology's performance is characterized in many trials involving four random realizations of strain-rate dependent material-test data curves per trial, drawn from a large synthetic population. The J-C model is calibrated to particular combinations of the data curves to obtain calibration parameter sets which are then propagated to “Can Crush” structural model predictions to produce samples of predicted response variability. These are processed with appropriate sparse-sample uncertainty quantification (UQ) methods to estimate various statistics of response with an appropriate level of conservatism. This is tested on 16 output quantities (von Mises stresses and equivalent plastic strains) and it is shown that important statistics of the true variabilities of the 16 quantities are bounded with a high success rate that is reasonably predictable and controllable. The DD approach has several advantages over other calibration-UQ approaches like Bayesian inference for capturing and utilizing the information obtained from typically small numbers of replicate experiments in model calibration situations—especially when sparse replicate functional data are involved like force–displacement curves from material tests. The DD methodology is straightforward and efficient for calibration and propagation problems involving aleatory and epistemic uncertainties in calibration experiments, models, and procedures.

42 ENGINEERING↗

Device and system for selective ionization and analyte detection and method of using the same

Disclosed herein are embodiments of a system for selectively ionizing samples that may comprise a plurality of different analytes that are not normally detectable using the same ionization technique. The disclosed system comprises a unique split flow tube that can be coupled with a plurality of ionization sources to facilitate using different ionization techniques for the same sample. Also disclosed herein are embodiments of a method for determining the presence of analytes in a sample, wherein the number and type of detectable analytes that can be identified is increased and sensitivity and selectivity are not sacrificed.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Device and system for selective ionization and analyte detection and method of using the same

Disclosed herein are embodiments of a system for selectively ionizing samples that may comprise a plurality of different analytes that are not normally detectable using the same ionization technique. The disclosed system comprises a unique split flow tube that can be coupled with a plurality of ionization sources to facilitate using different ionization techniques for the same sample. Also disclosed herein are embodiments of a method for determining the presence of analytes in a sample, wherein the number and type of detectable analytes that can be identified is increased and sensitivity and selectivity are not sacrificed.

Denis, Elizabeth↗

3D tracking of particles in a dusty plasma by laser sheet tomography

The collective behavior of levitated particles in a weakly ionized plasma (dusty plasma) has raised significant scientific interest. This is due to the complex array of forces acting on the particles and their potential to act as in situ diagnostics of the plasma environment. Ideally, the three-dimensional (3D) motion of many particles should be tracked for long periods of time. Typically, stereoscopic imaging using multiple cameras combined with particle image velocimetry is used to obtain a velocity field of many particles, yet this method is limited by its sample volume and short time scales. Here, we demonstrate a different, high-speed tomographic imaging method capable of tracking individual particles. We use a scanning laser sheet coupled to a single high-speed camera. We are able to identify and track tens of individual particles over centimeter length scales for several minutes, corresponding to more than 10 000 frames.

Physics↗

Adaptive Uncertainty Quantification for Stochastic Hyperbolic Conservation Laws

Here, we propose a predictor-corrector adaptive method for the study of hyperbolic partial differential equations (PDEs) under uncertainty. Constructed around the framework of stochastic finite volume (SFV) methods, our approach circumvents sampling schemes or simulation ensembles while also preserving fundamental properties, in particular hyperbolicity of the resulting systems and conservation of the discrete solutions. Furthermore, we augment the existing SFV theory with a priori convergence results for statistical quantities, in particular push-forward densities, which we demonstrate through numerical experiments. By linking refinement indicators to regions of the physical and stochastic spaces, we drive anisotropic refinements of the discretizations, introducing new degrees of freedom where deemed profitable. To illustrate our proposed method, we consider a series of numerical examples for nonlinear hyperbolic PDEs based on Burgers’ and Euler’s equations.

97 MATHEMATICS AND COMPUTING↗