Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resistive heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Superconductivity in MgTa 2 S 5

Superconductivity in the new compound, MgTa 2 S 5 , is reported. Its crystal structure was indexed to space group $C$2/$m$, which is monoclinic with lattice parameters $a$ = 5.784(5) $\mathring{A}$, $b$ = 12.680(3) $\mathring{A}$, and $c$ = 6.106(5) $\mathring{A}$, with $β$ = 112.64°. Electrical resistivity reveals metallic behavior with $ρ$(296 K) = 5.2 mΩ cm and bulk superconductivity below $T$ $c$ = 1 K. Measurements of the specific heat C reveal the electronic specific heat coefficient $γ$ = 11.1(5) mJ/mol K 2 , a jump in $C$ at $T$ $c$ illustrating bulk superconductivity, and an energy gap associated with the superconducting state of $E$ $g$ = 0.25(3) meV. MgTa 2 S 5 can be classified as a BCS superconductor. In conclusion, an unidentified minority phase present in the sample (~ 4%) exhibits a superconducting phase transition near 2.6 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U)

First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm. This array measures the energies of unconfined energetic 3 MeV protons and 1 MeV tritons mainly produced by beam-thermal DD reactions during neutral beam injection heating. Diamond detectors have the potential to be uniquely suited to detect charged fusion products as they promise to be much more radiation resistant and much less sensitive to temperature variations compared to silicon-based detectors. Using silicon and diamond-based detectors simultaneously allowed us to directly compare the performance of these two detector types. PD particle rates measured during different plasma scenarios are presented and compared to neutron rates measured using the neutron camera upgrade and TRANSP predictions.

Instruments & Instrumentation↗

Development of High-Temperature Emissivity Measurement Capabilities for Molten Salts at PNNL

In this study, an emissivity measurement system for a liquid molten salt was developed on the bases on the Stefan Boltzmann Law. A prototype device operating in ambient atmosphere was constructed an initial result compared well with available literature. The diffuse emissivity of NaCl-KCl system (NaCl, 51mol% NaCl – 49mol% KCl and KCl) was measured from 550 to 850 °C at a wavelength of 1.3 µm. The system appears to be relatively invariant with composition but a clear trend of decreasing emissivity values from ~0.9 at 550 °C to 0.75 at 850 °C was observed. A schematic for an enclosed system for inert atmosphere and actinide salts was drafted. Several of the components for fabrication of this device, improved laser system, furnace, nickel for capsule construction, have been purchased and are ready for assembly. The new laser system will have an improved measurement range of 275-1000 °C. The clam shell furnace has a maximum temperature of 1200 °C and will support the hermetically sealed inert encapsulation vessels. Nickel plate and tubing will create a relatively corrosion resistance capsule for testing that can withstand temperature up to 1000 °C. Emissivity measurements are important for a larger effort to understand radiative heat transfer within molten salts at elevated temperatures (600-1000 °C). Literature review of optical salt properties and radiative heat transfer models indicated that systems within elevated temperature regimes could see upwards of 20% or more of their total heat transferred through photonic mechanisms. Ultimately, future work will measure the total thermal conductivity and break down the molecular and radiative portions. Thermal conductivity, along with other thermal properties of molten salts, both coolant and fuel, are fundamental to modeling and simulations that support MSR design. The results presented here and ongoing work at PNNL will be useful in selecting optimal salt compositions, designing reactor systems, and optimizing heat transfer within a MSR power plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical Failure Risk Management for In-Service CSP Nitrate Hot Tanks

The hot thermal energy storage tanks in many operating (Gen2) concentrating solar power plants are designed to contain molten nitrate solar salt at 565 Degrees Celsius and are constructed from 347H stainless steel (SS). From previous work, it is known that 347H SS weldments are potentially susceptible to stress-relaxation cracking (SRC), particularly in the heat-affected zone above 540 Degrees Celsius when no post-weld heat-treatment (PWHT) is performed. However, residual stresses can be reduced when weldments receive PWHT, while at the same time a crack-resistant microstructure is being generated. The overarching goal of this project was to optimize cost-effective, thickness-dependent, localized PWHT procedures and to investigate for feasible non-destructive evaluation (NDE) at commercial scale for hot tanks in Gen2 CSP using 347H SS.

14 SOLAR ENERGY↗

Corrosion Resistance of 309L Stainless Steel Claddings on Carbon Steel Produced with Wire-Fed Directed Energy Deposition

Additive manufacturing (AM) tools are capable of applying overlay austenitic stainless steel (SS) claddings to carbon steel components. The benefits of this approach over arc welding include a smaller heat-affected zone, residual stress reduction, and material savings. In particular, wire-directed energy deposition is a suitable technique because of its low material cost and high rate of production compared to other AM methods. However, metallurgical variations in composition, phase fraction, and microsegregation can potentially influence the corrosion behavior of such claddings. In this work, 309L SS is clad on carbon steel substrates and electrochemical methods are used to measure their general and pitting corrosion resistance in simulated marine environments (3.5 wt% NaCl solutions). Two-layer claddings are fabricated with four laser powers to understand the effects of bulk chemical composition, austenite/δ-ferrite phase fractions, and individual phase compositions on corrosion behavior. The two-layer claddings are compared to a single-layer cladding, wrought 304 SS, and the carbon steel substrate for a comprehensive assessment of corrosion performance. The two-layer claddings are remarkably resistant to general corrosion in the 3.5 wt% NaCl environment because of their high Cr content (21.6 wt% to 23.3 wt% Cr). The single-layer cladding exhibits localized corrosion at unmixed Fe-rich peninsulas that originate at the dissimilar metal boundary and protrude into the first cladding layer. All two-layer claddings possess higher pitting corrosion resistance than wrought 304 SS, demonstrating their effectiveness as a corrosion-resistant barrier. Here, the pitting corrosion resistance is superior for claddings made with lower laser powers, due to low dilution and greater δ-ferrite contents.

36 MATERIALS SCIENCE↗

Co-, Ni- and Fe-rich grain-boundary phases enhance creep resistance in θ'-strengthened Al-Cu alloys

Here, microstructural evolution and creep response were investigated in the cast Al-5.0Cu-0.3Mn-0.2Zr (wt.%) alloy with and without addition of slow-diffusing, intermetallic-forming elements Fe, Ni, or Co. Baseline Al-5.0Cu-0.3Mn-0.2Zr alloy exhibits high creep resistance at 300 °C, up to ~75 MPa, which is attributed to high-aspect-ratio, intragranular θ'-Al 2 Cu precipitates that effectively suppress dislocation climb. However, θ'-Al 2 Cu precipitate-free zones form along grain boundaries upon heat treatment, whose extent is amplified during subsequent creep. Such weak regions experience dislocation creep, leading to strain localization and acceleration of grain-boundary sliding. Adding Ni and Co, individually or in combination, leads to the formation of grain-boundary precipitates (Al 9 Co 2 , Al 3 Ni 2 ) which are resistant to coarsening, thus suppressing the formation of θ'-Al 2 Cu precipitate-free zones. This microstructure provides high creep resistance at stresses up to 75–80 MPa, with strain rates much lower than in unmodified Al-5.0Cu-0.3Mn-0.2Zr. Adding Fe, which results in extensive decoration of grain boundaries with coarsening-resistant Al 7 Cu 2 Fe, and then increasing the Cu content to compensate for the Cu loss to this new phase, leads to a new Al-7.4Cu-1.6Fe-0.3Mn-0.2Zr alloy with creep resistance at 300 °C that surpasses known cast aluminum alloys. Adding Fe to improve the creep resistance of Al-Cu alloys is both cost-effective and sustainable. Our findings offer guidelines applicable to various alloy systems on controlling the evolution of precipitate-free zones and its ensuing effects on creep deformation.

36 MATERIALS SCIENCE↗

Automotive Silicon Carbide Power Module Cooling With A Novel Modular Manifold And Embedded Heat Sink

The next generation of integrated power electronics packages will implement wide-bandgap devices with ultrahigh device heat fluxes. Although jet impingement has received attention for power electronics thermal management, it is not used in commercial electric vehicles (EVs) because of the associated pressure drop and reliability concerns. Here, in this paper, we present a modular thermal management system designed for automotive power electronics. The system achieves superior thermal performance to benchmarked EVs, while adhering to reliability standards and with low pumping power. The system utilizes a low-cost and lightweight plastic manifold to generate jets over an optimized heat sink, which is embedded in the direct-bonded-copper (DBC) substrate. The embedded heat sink concept leverages additive manufacturing to add elliptical pin fins to the DBC substrate. The heat sink geometry is optimized for submerged jet impingement using a unit-cell model and an exhaustive search algorithm. The model predictions are validated using unit-cell experiments. A full-scale power module model is then used to compare the DBC-embedded heat sink against direct DBC cooling and baseplate-integrated heat sinks for single-sided (SS) and double-sided (DS) cooling concepts. Using the SS and DS DBC-embedded cooling concepts, the models predict a thermal resistance that represents a reduction of 75% and 85% compared to the 2015 BMW i3, respectively, for the same water-ethylene glycol inverter flow rate. We have shown that an inverter with a 100-kilo-Watt-per-liter power density is achievable with the proposed design.

33 ADVANCED PROPULSION SYSTEMS↗

Data-Driven Reduced-Order Modeling of Convective Heat Transfer in Porous Media

This work presents a data-driven Reduced-Order Model (ROM) for parametric convective heat transfer problems in porous media. The intrusive Proper Orthogonal Decomposition aided Reduced-Basis (POD-RB) technique is employed to reduce the porous medium formulation of the incompressible Reynolds-Averaged Navier–Stokes (RANS) equations coupled with heat transfer. Instead of resolving the exact flow configuration with high fidelity, the porous medium formulation solves a homogenized flow in which the fluid-structure interactions are captured via volumetric flow resistances with nonlinear, semi-empirical friction correlations. A supremizer approach is implemented for the stabilization of the reduced fluid dynamics equations. The reduced nonlinear flow resistances are treated using the Discrete Empirical Interpolation Method (DEIM), while the turbulent eddy viscosity and diffusivity are approximated by adopting a Radial Basis Function (RBF) interpolation-based approach. The proposed method is tested using a 2D numerical model of the Molten Salt Fast Reactor (MSFR), which involves the simulation of both clean and porous medium regions in the same domain. For the steady-state example, five model parameters are considered to be uncertain: the magnitude of the pumping force, the external coolant temperature, the heat transfer coefficient, the thermal expansion coefficient, and the Prandtl number. For transient scenarios, on the other hand, the coastdown-time of the pump is the only uncertain parameter. The results indicate that the POD-RB-ROMs are suitable for the reduction of similar problems. The relative L2 errors are below 3.34% for every field of interest for all cases analyzed, while the speedup factors vary between 54 (transient) and 40,000 (steady-state).

German, Péter (ORCID:0000000307285283)↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling thermal energy storage in structural cementitious composites with a novel phase change material microcapsule featuring an inorganic shell and a bio-inspired silica coating

Phase change material (PCM) microcapsules offer a promising approach for integrating PCM into building materials for efficient thermal energy storage. Here, this study presents the development of a novel PCM microcapsule specifically designed for incorporation into cementitious materials. The microcapsule consists of a low-cost PCM core derived from vegetable oil by-products and a durable inorganic shell made from cenosphere, a hollow fly ash generated from coal burning power plants. A novel process is developed to apply a silica coating to these cenosphere-based PCM microcapsules (CPCM), resulting in bioinspired-silica-coated CPCM microcapsules (BCPCM). This coating process draws inspiration from marine microorganism-based silica production and utilizes low-cost sodium silicate as a precursor, enabling eco-friendly and cost-effective manufacturing at ambient temperature and mild pH conditions. The morphology, chemical stability, and thermal properties of the BCPCM along with its thermo-mechanical performance in cementitious composites were comprehensively analyzed. Experimental results demonstrate successful silica deposition on BCPCM, leading to enhanced latent heat properties of the produced BCPCM. With the silica coating, BCPCM exhibits a 50 °C delay in thermal decomposition compared to CPCM, enhancing fire resistance and preventing premature PCM leakage of the microcapsule. The bioinspired silica coating effectively restores over 10% of the strength loss for each percent increase in CPCM incorporated into the mortar. The thermal performance experiments reveal that increasing the BCPCM content reduces temperature peaks and rates of temperature increase, indicating an improved capacity for thermal energy storage. This new PCM microcapsule provides a cost-effective solution to integrate thermal energy storage to cementitious material, as evidenced that over 30% of aggregates (in volume) can be replaced by the microcapsule without a drastic loss of strength.

25 ENERGY STORAGE↗

Correlation between microstructure and residual stress formation in friction stir welded armor steels characterized by neutron diffraction

Friction stir welding (FSW) is a solid-state joining process that minimizes the heat-affected zone (HAZ) compared with fusion-based arc welding, making it well suited for joining martensitic armor steels where hardness and ballistic resistance are critical. This study investigates residual stress formation in three defect-free FSW butt-joint configurations relevant to armored-vehicle fabrication: similar rolled homogeneous armor (RHA–RHA, Case 1), similar high-hardness armor (HHA–HHA, Case 2), and dissimilar HHA–RHA (Case 3) joints produced under temperature-controlled conditions (770 °C). Neutron diffraction was employed to quantify the magnitude and spatial distribution of residual stresses in the longitudinal, transverse, and normal directions and to correlate them with weld microstructure and hardness. Tensile residual stresses were concentrated in the softened HAZ, reaching approximately 300 MPa for Case 2 and 400 MPa for Case 1 (≈50–70 % of the base-metal yield strength; ∼581 MPa for RHA and ∼566 MPa for HHA), while compressive residual stresses dominated the stir zone. The spatial extent of tensile stresses scaled with the width of the softened HAZ, which was largest in the dissimilar HHA–RHA joint and smallest in the HHA–HHA joint. Full-width-at-half-maximum (FWHM) analysis revealed low microstrain in overtempered HAZ regions and high microstrain in the stir zone associated with severe plastic deformation and fresh martensite formation. This work demonstrates that residual stress evolution in FSW of martensitic armor steels is governed not primarily by peak temperature or thermal contraction, as inferred from fusion-welding analogies, but by the competition between transformation-induced volumetric expansion and tempering-induced stress relaxation. The relative dominance of these mechanisms is shown to depend on alloy hardenability and local thermal history, leading to more extensive HAZ softening and broader tensile stress regions in the lower-hardenability RHA steel. These findings establish a transferable mechanistic framework for optimizing solid-state joining strategies in high-strength steels and other transformation-hardening alloys beyond armor applications.

Friction stir welding↗

Structure, electrical and thermal properties of single-crystal BaCuGdTe 3

Single crystals of the quaternary chalcogenide BaCuGdTe 3 were obtained by direct reaction of elements allowing for a complete investigation of the intrinsic electrical and thermal properties of this previously uninvestigated material. The structure was investigated by high-resolution single-crystal synchrotron X-ray diffraction, revealing an orthorhombic crystal structure with the space group Cmcm. Although recently identified as a semiconductor suitable for thermoelectric applications from theoretical analyses, our electrical resistivity and Seebeck coefficient measurements show metallic conduction, the latter revealing strong phonon-drag. Temperature dependent hole mobility reveals dominant acoustic phonon scattering. Heat capacity data reveal a Debye temperature of 183 K and a very high density of states at the Fermi level, the latter confirming the metallic nature of this composition. Thermal conductivity is relatively high with Umklapp processes dominating thermal transport above the Debye temperature. The findings in this work lay the foundation for a more detailed understanding of the physical properties of this and similar multinary chalcogenide materials, and is part of the continuing effort in investigating quaternary chalcogenide materials and their suitability for use in technological applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extended linear-in- T resistivity due to electron-phason scattering in moiré superlattices

Due to its incommensurate nature, moiré superlattices host not only acoustic phonons but also another type of soft collective modes called phasons. Here, we investigate the impact of electron-phason scattering on the transport properties of moiré systems. We show that the resistivity can scale linearly with temperature down to temperatures much lower than the Bloch-Grüneisen scale defined by electron kinematics on the Fermi surface. This result stems from the friction between layers, which transfers phason spectral weight to a broad diffusive low-energy peak in the mechanical response of the system. As a result, phason scattering becomes a very efficient channel for entropy production at low temperatures. We also consider the contributions of phasons to thermodynamic properties at low temperatures and find a “metallic-like” linear-in-T behavior for the specific heat, despite the fact that this behavior is due to mechanical and not electronic degrees of freedom. Finally, we discuss the implications of this finding to reports of linear-in-T resistivity in the phase diagram of twisted bilayer graphene.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accelerated Creep Test Qualification of Creep-Resistance Using the Wilshire–Cano–Stewart Constitutive Model and Stepped Isostress Method

In this paper, a qualification of accelerated creep-resistance of Inconel 718 is assessed using the novel Wilshire–Cano–Stewart (WCS) model and the stepped isostress method (SSM) and predictions are made to conventional creep data. Conventional creep testing is a long-term continuous process; in fact, the ASME B&PV III requires that 10,000+ h of experiments must be conducted to each heat for materials employed in boilers and/or pressure vessel components. This process is costly and not feasible for rapid development of new materials. As an alternative, accelerated creep testing techniques have been developed to reduce the time needed to characterize the creep resistance of materials. Most techniques are based upon the time-temperature-stress superposition principle that predicts minimum-creep-strain-rate (MCSR) and stress-rupture behaviors but lack the ability to predict creep deformation and consider deformation mechanisms that occur for experiments of longer duration. The SSM has been developed, which enables the prediction of creep deformation response as well as reduce the time needed for qualification of materials. The SSM approach has been successful for polymer, polymeric composites, and recently has been introduced for metals. In this study, the WCS constitutive model, calibrated to SSM test data, qualifies the creep resistance of Inconel 718 at 750 °C and predictions are compared to conventional creep testing data. The WCS model has proven to make long-term predictions for stress-rupture, MCSR, creep deformation, and damage in metallic materials. The SSM varies stress levels after time interval adding damage to the material, which can be tracked by the WCS model. The SSM data is calibrated into the model and the WCS model generates realistic predictions of stress-rupture, MSCR, damage, and creep deformation. The calibrated material constants are used to generate predictions of stress-rupture and are postaudit validated using the National Institute of Material Science database. Similarly, the MCSR predictions are compared from previous studies. Finally, the creep deformation predictions are compared with real data and is determined that the results are well in between the expected boundaries. Material characterization and mechanical properties can be determined at a faster rate and with a more cost-effective method. This is beneficial for multiple applications such as in additive manufacturing, composites, spacecraft, and industrial gas turbines.

42 ENGINEERING↗

Generalized and Mechanistic PV Module Performance Prediction From Computer Vision and Machine Learning on Electroluminescence Images

Electroluminescence (EL) imaging of photovoltiac (PV) modules offers high-speed, high-resolution information about device performance, affording opportunities for greater insight and efficiency in module characterization across manufacturing, research and development, and power plant operations and management. Predicting module electrical properties from EL image features is a critical step toward these applications. In this article, we demonstrate quantification of both generalized and performance mechanism-specific EL image features, using pixel intensity-based and machine learning classification algorithms. From EL image features, we build predictive models for PV module power and series resistance, using time-series current-voltage (I-V) and EL data obtained stepwise on five brands of modules spanning three Si cell types through two accelerated exposures: damp heat (DH) (85°C/85% RH) and thermal cycling (TC) (IEC 61215). Overall, 195 pairs of EL images and I-V characteristics were analyzed, yielding 11700 individual PV cell images. A convolutional neural network was built to classify cells by the severity of busbar corrosion with high accuracy (95%). Generalized power predictive models estimated the maximum power of PV modules from EL images with high confidence and an adjusted-R 2 of 0.88, across all module brands and cell types in extended DH and TC exposures. Mechanistic degradation prediction was demonstrated by quantification of busbar corrosion in EL images of three module brands in DH, and subsequent modeling of series resistance using these mechanism-specific EL image features. For modules exhibiting busbar corrosion, we demonstrated series resistance predictive models with adjusted-R 2 of up to 0.73.

14 SOLAR ENERGY↗