Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rapid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Rapid synthesis of phase-engineered tungsten carbide electrocatalysts via flash joule heating for high-current-density hydrogen evolution

Fabricating durable and high-performance electrocatalysts operating at high current densities for industrial acidic hydrogen evolution remains a daunting challenge. Tailoring the phase composition of electrocatalysts is a promising strategy to harness synergistic effects and improve charge transfer, thereby optimizing their performance. Here, this work presents a fast, green method based on flash joule heating (FJH) to synthesize phase-engineered tungsten carbide electrocatalysts for the acidic hydrogen evolution reaction (HER) at high current densities. Tungsten carbide electrodes with varying FJH treatment durations (3, 10, 30, and 60 s) are fabricated to fine-tune the mixture of tungsten monocarbide (WC) and tungsten semicarbide (W 2 C) phases. Results show that samples with a 30-s treatment (TC-3) exhibit an optimal balance between these phases, leading to a low overpotential of 180.97 and 387 mV at current densities of 10 mA/cm 2 and 4 A/cm 2 , respectively. TC-3 exhibits significantly lower charge transfer resistance compared to the other electrocatalysts, which can be attributed to its optimal phase ratio. Notably, the TC-3 electrocatalyst remains stable for over 9 days at 4 A/cm 2 due to their controlled phases and excellent corrosion-resistant properties. This work highlights a new method to fabricate cost-effective, high-performance tungsten carbide electrocatalysts with well-controlled phase compositions.

Acidic hydrogen evolution reaction↗

Raman spectroscopy coupled with ambient ionization mass spectrometry: A forensic laboratory investigation into rapid and simple dual instrumental analysis techniques

We present a laboratory experiment, developed around a pair of instrumental analysis techniques, Raman spectroscopy and ambient ionization mass spectrometry (MS), conducted by senior chemistry undergraduate students for bulk analysis of over-the-counter drugs using benchtop versions of the two instruments, as well as trace analysis of illicit drugs utilizing the corresponding portable instruments. The identification and confirmation of seized drugs is a routine operation in forensic laboratories that can be simplified using these two instrumental techniques in tandem. Bulk samples are readily analyzed using conventional Raman spectroscopy followed by paper cone spray ionization (PCSI) MS, while trace analysis is allowed by a simple single-substrate dual-analyzer method using surface enhanced Raman spectroscopy (SERS) from paper followed by paper spray ionization (PSI) MS. The introduction of these novel strategies to the students exposed them to potential career paths in forensic science by means of a hands-on experience that provided fundamental knowledge about this set of analytical methods, including intercomparisons of their performance, as well as practical issues like costs, regulations and databases. The use of portable instrumentation represents an additional learning experience for the students, considering that it is cutting-edge technology that is just now being transferred from academic to industrial labs and that it allows a valuable discussion of the advantages and disadvantages of bringing the laboratory to the field.

47 OTHER INSTRUMENTATION↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗

Utility of Circulating MicroRNA-150 for Rapid Evaluation of Bone Marrow Depletion After Radiation and Efficiency of Bone Marrow Reconstitution

Total body irradiation (TBI) is a common myeloablative preparative regimen used in acute myeloid and lymphoblastic leukemia patients before allogenic hematopoietic stem cell transplantation (HSCT). The inefficient clearance of tumor cells and radiation-induced toxicity to normal tissues is attributed to relapse and morbidity in a significant fraction of patients. Developing biomarkers that indicate an individual's physiological response to radiation will allow personalized treatment and follow-up. We investigated the utility of circulating microRNA150-5p (miR150) for evaluation of radiation dose response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Glass transition temperature studies of planetary ball milled glasses: Accessing the rapidly cooled glassy state in Na 4 P 2 S 7-x O x , 0 ≤ x ≤ 7, Oxy-thio phosphate glasses

This paper details the very first in-depth study of the glass transition temperature (T g ) for planetary balled milled (PBM) Na 4 P 2 S 7-x O x (NaPSO), where 0 ≤ x ≤ 7, glasses. For 0 ≤ x ≤ 5, fully amorphous, homogeneous, and chemically reacted compositions can be prepared. For samples with 5 < x ≤ 7, partially amorphous but fully chemically reacted glass-ceramics can be produced. The reproducible, thermally cyclable onset T g and the onset crystallization temperature, T c , were investigated as a function of the composition and of the short-range order (SRO) structures of the glasses. Additionally, we examined the extreme sub-T g exothermic relaxations present due to the high energy milling processing and correspondingly high effective quenching rate. Using a differential scanning calorimeter (DSC) and scanning from well below the onset T g , the glasses are observed to relax exothermally below T g . The integrated relaxation enthalpy, ΔH rel , is ~ 0 for the x = 2 glass, but is significantly exothermic for lower and higher values of x. Once the high fictive state of these glasses has been erased by scanning to above the T g , but below the T c of the glass, the DSC scans of the glasses recover normal behavior for a normally cooled glass without any relaxation exotherm. The T g s of these glasses remain relatively constant for 0 ≤ x ≤ 3, but for glasses with 3 < x ≤ 5, T g increases sharply following the combined effects of the phosphate chain length increasing caused by the formation of bridging oxygens and the increasing concentration of more charge dense non-bridging oxygens (NBOs). For x > 5, both T g and Tc decrease sharply, becoming nearly identical at x = 7 where glass formation essentially ceases. For smaller values of x, T c increases with both chain length and the structural complexity of the composition but decreases sharply for glass-ceramics of x > 5.

36 MATERIALS SCIENCE↗

Rapid Open-Air Fabrication of Perovskite Solar Modules

We report on the open-air fabrication of perovskite solar modules with key advances including scalable large-area spray deposition, new monolithic integration scribing techniques, advanced photoluminescence characterization, and reproducible high-throughput manufacturability. Perovskite deposition with linear speeds of 12 m/min without a post-anneal are demonstrated with improved device performance, luminescent yield and >10X carrier lifetimes. Manufacturability using monolithic integration of series-connected modules is accomplished with a new indirect fiber laser ablation scribing method. A stable cell and module power output of 18.0% and 15.5%, respectively, was achieved with a subcell V oc > 1.06V. A comprehensive supporting technoeconomic analysis details the entire in-line manufacturing process from the glass substrate to the junction box of the encapsulated module. Here, the module manufacturing cost, balance of system costs and levelized cost of energy for a range of module efficiencies and lifetimes provides insights for the necessary tool speeds, efficiencies, and lifetimes for utility-scale energy generation.

14 SOLAR ENERGY↗