Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

SIMPLE WAVES IN IDEAL RADIATION HYDRODYNAMICS

In the dynamic diffusion limit of radiation hydrodynamics, advection dominates diffusion; the latter primarily affects small scales and has negligible impact on the large-scale flow. The radiation can thus be accurately regarded as an ideal fluid, i.e., radiative diffusion can be neglected along with other forms of dissipation. This viewpoint is applied here to an analysis of simple waves in an ideal radiating fluid. It is shown that much of the hydrodynamic analysis carries over by simply replacing the material sound speed, pressure, and adiabatic index with the values appropriate for a radiating fluid. A complete analysis is performed for a centered rarefaction wave, and expressions are provided for the Riemann invariants and characteristic curves of the one-dimensional system of equations. The analytical solution is checked for consistency against a finite difference numerical integration, and the validity of neglecting the diffusion operator is demonstrated. An interesting physical result is that for a material component with a large number of internal degrees of freedom and an internal energy greater than that of the radiation, the sound speed increases as the fluid is rarefied. These solutions are an excellent test for radiation hydrodynamic codes operating in the dynamic diffusion regime. The general approach may be useful in the development of Godunov numerical schemes for radiation hydrodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of Scatter Peaks in 137 Cs and 60 Co Sources

Results from tests of radiation detection instruments with radionuclide identification capabilities will depend on the sources used for the tests. Radionuclide identification detectors are designed to measure photons and provide an identification of the source being measured. High-resolution spectra need to be acquired to determine all the observable peaks in the source spectra before testing these types of instruments. These peaks may be due to impurities and/or scatter peaks in the sources. This paper discusses the issues encountered with the response of a radioisotope identification device due to scatter peaks in one type of source used for testing. In addition, it provides spectra for different source types and source constructions to compare the differences in scatter, allowing for a better source type selection for instrument testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar cell development for the Power Extension Package

The Power Extension Package (PEP), a 32-kilowatt, flexible-substrate, retrievable solar array system for use on the Space Shuttle, is described. It is noted that solar cell costs will be reduced by increasing cell area and simplifying cell and coverglass fabrication processes and specifications. The tests that have been carried out on the cells are described, among them a unique radiation damage test and a side-by-side comparison of candidate cell types with pre- and post-irradiation airplane calibration of outer space short-circuit current

Baraona, C. R.↗

Simple Waves in Ideal Radiation Hydrodynamics

In the dynamic diffusion limit of radiation hydrodynamics, advection dominates diffusion; the latter primarily affects small scales and has negligible impact on the large scale flow. The radiation can thus be accurately regarded as an ideal fluid, i.e., radiative diffusion can be neglected along with other forms of dissipation. This viewpoint is applied here to an analysis of simple waves in an ideal radiating fluid. It is shown that much of the hydrodynamic analysis carries over by simply replacing the material sound speed, pressure and index with the values appropriate for a radiating fluid. A complete analysis is performed for a centered rarefaction wave, and expressions are provided for the Riemann invariants and characteristic curves of the one-dimensional system of equations. The analytical solution is checked for consistency against a finite difference numerical integration, and the validity of neglecting the diffusion operator is demonstrated. An interesting physical result is that for a material component with a large number of internal degrees of freedom and an internal energy greater than that of the radiation, the sound speed increases as the fluid is rarefied. These solutions are an excellent test for radiation hydrodynamic codes operating in the dynamic diffusion regime. The general approach may be useful in the development of Godunov numerical schemes for radiation hydrodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RHETT2/EPDM Hall Thruster Propulsion System Electromagnetic Compatibility Evaluation

Electromagnetic compatibility measurements were obtained as part of the Electric Propulsion Demonstration Module (EPDM) flight qualification program. Tests were conducted on a Hall thruster system operating at a nominal 66O W discharge power. Measurements of conducted and radiated susceptibility and emissions were obtained and referenced to MEL-STD-461 C. The power processor showed some conducted susceptibility below 4 kHz for the magnet current and discharge voltage. Radiated susceptibility testing yielded a null result. Conducted emissions showed slight violations of the specified limit for MIL-461C CE03. Radiated emissions exceeded the RE02 standard at low frequencies, below 300 MHz, by up to 40 dB RV/m/MHz.

Sarmiento, Charles J.↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progess at RML are improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progress at RML is improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved Spacecraft Materials for Radiation Protection

Methods by which radiation shielding is optimized need to be developed and materials of improved shielding characteristics identified and validated. The galactic cosmic rays (GCR) are very penetrating and the energy absorbed by the astronaut behind the shield is nearly independent of shield composition and even the shield thickness. However, the mix of particles in the transmitted beam changes rapidly with shield material composition and thickness. This results in part from the breakup of the high-energy heavy ions of the GCR which make contributions to biological effects out of proportion to their deposited energy. So the mixture of particles in the radiation field changes with shielding and the control of risk contributions from dominant particle types is critical to reducing the hazard to the astronaut. The risk of biological injury for a given particle type depends on the type of biological effect and is specific to cell or tissue type. Thus, one is faced with choosing materials which may protect a given tissue against a given effect but leave unchanged or even increase the risk of other effects in the same tissue or increase the risks to other adjacent tissues of a different type in the same individual. The optimization of shield composition will then be tied to a specific tissue and risk to that tissue. Such peculiarities arise from the complicated mixture of particles, the nature of their biological response, and the details of their interaction with material constituents. Aside from the understanding of the biological response to specific components, one also needs an accurate understanding of the radiation emerging from the shield material. This latter subject has been a principal element of this project. In the past ten years our understanding of space radiation interactions with materials has changed radically, with a large impact on shield design. For example, the NCRP estimated that only 2 g/sq cm. of aluminum would be required to meet the annual 500 mSv limit for the exposure of the blood forming organs (this limit is strictly for LEO but can be used as a guideline for the Mars mission analysis). The current estimates require aluminum shield thicknesses above 50 g/sq cm., which is impractical. In such a heavily shielded vehicle, the neutrons produced throughout the vehicle also contribute significantly to the exposure and this demands greater care in describing the angular dependence of secondary particle production processes. As such the continued testing of databases and transport procedures in laboratory and spaceflight experiments has continued. This has been the focus of much of the last year's activity and has resulted in improved neutron prediction capability. These new methods have also improved our understanding of the surface environment of Mars. The Mars 2003 NRA HEDS related surface science requirements were driven by the need to validate predictions on the upward flux of neutrons produced in the Martian regolith and bedrock made by the codes developed under this project. The codes used in the surface environment definition are also being used to look at in situ resources for the development of construction material for Martian surface facilities. For example, synthesis of polyimides and polyethylene as binders of regolith for developing basic structural elements has been studied and targets built for accelerator beam testing of radiation shielding properties. Preliminary mechanical tests have also been promising. Improved spacecraft materials have been identified (using the criteria reported by this project at the last conference) as potentially important for future shielding materials. These are liquid hydrogen, hydrogenated nanofibers, liquid methane, LiH, Polyethylene, Polysulfone, and Polyetherimide (in order of decreasing shield performance). Some of the materials are multifunctional and are required for other onboard systems. We are currently preparing software for trade studies with these materials relative to the Mars Reference Mission as required in the project's final year.

Wilson, John W.↗

StaNdaRT: a repository of standardised test models and outputs for supernova radiative transfer

We present the first results of a comprehensive supernova (SN) radiative-transfer (RT) code-comparison initiative (StaNdaRT), where the emission from the same set of standardised test models is simulated by currently used RT codes. We ran a total of ten codes on a set of four benchmark ejecta models of Type Ia SNe. We consider two sub-Chandrasekhar-mass (M tot = 1.0 M ⊙ ) toy models with analytic density and composition profiles and two Chandrasekhar-mass delayed-detonation models that are outcomes of hydrodynamical simulations. We adopt spherical symmetry for all four models. The results of the different codes, including the light curves, spectra, and the evolution of several physical properties as a function of radius and time are provided in electronic form in a standard format via a public repository. We also include the detailed test model profiles and several Python scripts for accessing and presenting the input and output files. We also provide the code used to generate the toy models studied here. In this paper, we describe the test models, radiative-transfer codes, and output formats in detail, and provide access to the repository. We present example results of several key diagnostic features.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Attenuation Drift in the Micro-Computed Tomography System at LLNL

The maximum allowable level of drift in the linear attenuation coefficients (μ) for a Lawrence Livermore National Laboratory (LLNL) micro-computed tomography (MCT) system was determined to be 0.1%. After ~100 scans were acquired during the period of November 2014 to March 2015, the drift in μ for a set of six reference materials reached or exceeded 0.1%. Two strategies have been identified to account for or correct the drift. First, normalizing the 160 kV and 100 kV μ data by the μ of water at the corresponding energy, in contrast to conducting normalization at the 160 kV energy only, significantly compensates for measurement drift. Even after the modified normalization, μ of polytetrafluoroethylene (PTFE) increases linearly with scan number at an average rate of 0.00147% per scan. This is consistent with PTFE radiation damage documented in the literature. The second strategy suggested is the replacement of the PTFE reference with fluorinated ethylene propylene (FEP), which has the same effective atomic number (Ze) and electron density (ρe) as PTFE, but is 10 times more radiation resistant. This is important as effective atomic number and electron density are key parameters in analysis. The presence of a material with properties such as PTFE, when taken together with the remaining references, allows for a broad range of the (Ze, ρe) feature space to be used in analysis. While FEP is documented as 10 times more radiation resistant, testing will be necessary to assess how often, if necessary, FEP will need to be replaced. As radiation damage to references has been observed, it will be necessary to monitor all reference materials for radiation damage to ensure consistent x-ray characteristics of the references.

36 MATERIALS SCIENCE↗

Observational Signatures of Coronal Heating in Magnetohydrodynamic Simulations without Radiation or a Lower Atmosphere

It is extremely difficult to simulate the details of coronal heating and also make meaningful predictions of the emitted radiation. Thus, testing realistic models with observations is a major challenge. Observational signatures of coronal heating depend crucially on radiation, thermal conduction, and the exchange of mass and energy with the transition region and chromosphere below. Many magnetohydrodynamic simulation studies do not include these effects, opting instead to devote computational resources to the magnetic aspects of the problem. We have developed a simple method of accounting approximately for the missing effects. It is applied to the simulation output ex post facto and therefore may be a valuable tool for many studies. We have used it to predict the emission from a model corona that is driven by vortical boundary motions meant to represent photospheric convection. We find that individual magnetic strands experience short-term brightenings, both scattered throughout the computational volume and in localized clusters. The former may explain the diffuse component of the observed corona, while the latter may explain bright coronal loops. Several observed properties of loops are reproduced reasonably well: width, lifetime, and quasi-circular cross section (aspect ratio not high). Our results lend support to the idea that loops are multistranded structures heated by "storms" of nanoflares.

James A. Klimchuk↗

Method of predicting radiation heat transfer in turbine cooling test facilities

A method is presented for calculating the average net radiation heat flux to turbine vanes and blades. The net radiation heat flux at a vane leading edge calculated by this method was compared with heat flux values independently determined from experimental tests on a vane in a cascade. The spectral emissivities of the turbine vane and the cascade wall were also measured.

Gladden, H. J.↗

A Compact Electron-Proton Spectrometer for Moon / Mars Surface Space Weather Monitoring and Crew Protection (CEPS)

Small mass/low-power sensors are needed for autonomous Moon/Mars surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. Typical space weather sensors are at least an order of magnitude higher in mass than is expected from Timepix-based devices and are deployed on robotic assets away from human crews. High fidelity measurements at the crew location and subsequent ability are needed to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.​ The aim of this project is the development of compact, low power space weather sensors for crew protection based on the combination of AES flight heritage Timepix hardware with novel CdTe (Cadmium Telluride) sensors. CdTe technology has only recently matured to a point where it can be reliably used with Timepix detectors. These detectors will be able to measure electron spectra in an energy range relevant to the RELEASE model, which is used operationally by NASA to provide crew early warning of Solar Energetic Particle Events as well as protons in the energy ranges relevant to human health allowing for event ‘nowcasting’ and total event crew dose prediction. Compared to existing solutions these detectors will be compact enough to travel with crew, providing a significant advantage to space environment situation awareness. Project results indicate that CdTe-based Timepix sensors respond well to energetic electrons, and particle tracks are sufficiently distinct to be able to measure in a mixed radiation field. Thermal testing results point to a needed design modification to mitigate high temperatures the detector will see in space. Radiation susceptibility testing was conducted to assess the radiation hardness of the CdTe-Timepix assembly. Overall, the assembly continued to operate up to 100 kRad of gamma-ray exposure. The system calibration did show drift over time but recovered once exposure was complete.

Dan James Fry↗

Polymer Filler Aging and Failure Studied by Lateral Force Microscopy

In the present work, we study, via force microscopy, the basic physical interactions of a single bead of silica filler with a PDMS matrix both before and after exposure to gamma radiation. Our goal was to confirm our results from last year, and to explore force microscopy as a means of obtaining particle-scale polymer/filler interactions suitable for use as empirical inputs to a computational model consisting of an ensemble of silica beads embedded in a PDMS matrix. Through careful calibration of a conventional atomic force microscope, we obtained both normal and lateral force data that was fitted to yield adhesion, surface shear modulus, and friction of a 1 {micro}m silica bead in contact with PDMS layers of various thickness. Comparison of these terms before and after gamma exposure indicated that initially, radiation exposure lead to softening of the PDMS, but eventually resulted in stiffening. Simultaneously, adhesion between the polymer and silica decreased. This could indicate a serious failure path for filled PDMS exposed to radiation, whereby stiffening of the bulk polymer leads to loss of compressive elastic behavior, while a decrease in polymer filler adhesion results in an increased likelihood of stress failure under load. In addition to further testing of radiation damaged polymers, we also performed FEA modeling of silica beads in a silicone matrix using the shear modulus and adhesion values isolated from the force microscopy experiments as model inputs. The resulting simulation indicated that as a polymer stiffens due to impinging radiation, it also undergoes weakening of adhesion to the filler. The implication is that radiation induces a compound failure mode in filled polymer systems.

36 MATERIALS SCIENCE↗