Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

The Baghdad Atlas: A relational database of inelastic neutron-scattering (n,n ' γ) data

A relational database has been developed based on the original (n,n'γ) work carried out by A. M. Demidov et al., at the Nuclear Research Institute in Baghdad, Iraq (Demidov et al., 1978) for 105 independent measurements comprising 76 elemental samples of natural composition and 29 isotopically-enriched samples. The information from this Atlas includes: γ-ray energies and relative intensities; nuclide and level data corresponding to the residual nucleus and meta data associated with the target sample that allows for the extraction of the flux-weighted (n,n'γ) cross sections for a given transition relative to a defined value. The optimized angular-distribution-corrected fast-neutron flux-weighted partial γ-ray cross section for the production of the 846.8-keV 21+→0gs+γ-ray transition in 56Fe, determined to be $\langle$σγ$\rangle$=143(29) mb, is used for this purpose. However, different values for the adopted cross section can be readily implemented to accommodate user preference based on revised determinations of this quantity. The Atlas (n,n'γ) data has been compiled into a series of CSV-style ASCII data sets and a suite of Python scripts have been developed to build and install the database locally. The database can then be accessed directly through the SQLite engine, or using alternative methods such as the Jupyter Notebook Python-browser interface. Several examples exploiting different interaction methodologies are distributed with the complete software package.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Remediating neutron damage in large area planar Ge-DSSD with amorphous germanium contacts through annealing and pulse-height correction

Large area, position sensitive planar germanium detectors offer new opportunities in -ray spectroscopy. For in-beam studies remediating neutron damage is important. This work studied a mechanically cooled circular planar 9 × 1 cm wafer with orthogonal 16 × 16 amorphous germanium strip electrodes. Before neutron irradiation the wafer was heated in-cryostat to above 373 K for more than 24 h in order to test the robustness of the contacts and the mechanical cooler. No deterioration in performance was observed. The detector was then exposed to controlled doses of 2.2 MeV neutrons, produced from the 7 Li(p,n) 7 Be reaction until substantial damage was observed. Averaged over the surface of the wafer, a flux of 1.9(1) x 10 9 n/cm 2 was delivered. The detector then survived thermal cycling and 350 K (~77°C) annealing for 70 h which substantially reduced hole trapping. pulse-height correction is investigated to further mitigate the neutron damage. Higher temperature annealing at 365 K was not successful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An automated system to define the optimal operating settings of cryogenic calorimeters

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large mass single electron resolution detector for dark matter and neutrino elastic interaction searches

Large mass single electron resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CEvNS). In this paper we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of ~ 1e - /h + pair and a leakage current on the order of 10 -16 A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CEvNS like searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

6 MeV novel hybrid (standing wave - traveling wave) photo-cathode electron gun for a THz superradiant FEL

A novel 6 MeV hybrid photo-injector has been designed and constructed, based on a smaller-scale prototype previously built in UCLA’s Particle Beam Physics Laboratory. It has been commissioned at Ariel University in Israel as an on-going collaboration between the two universities. This unique, new generation design provides a radically simpler approach to RF feeding of a gun/buncher system, leading to a much shorter beam via velocity bunching owed to an attached traveling wave section of the photo-injector. This design offers better performance in beam parameters, providing a high quality electron beam, with energy of 6 MeV. The hybrid photo-injector was designed to provide emittance of approximately 3 μm, and pulse duration of 150 fs at up to 1 nC per pulse. The hybrid gun is driven by a SLAC XK5 klystron as the high power RF source, and third harmonic of a ~35 fs IR Laser amplifier (266 nm) to extract electrons from the photo-cathode. The unique electron gun will produce a bunched electron pulse to drive a THz FEL, which will operate at the super-radiant regime, and therefore requires ambitious beam properties. This paper describes the gun and presents experimental results from the gun and its sub-systems, including energy and charge measurements, compared with the design simulations.

150fs↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of hardware controls for the STAR experiment at RHIC

The STAR experiment has been delivering significant physics results for more than 20 years. Stable operation of the experiment was achieved by using a robust controls system based on the Experimental Physics and Industrial Control System (EPICS). Now an object-oriented approach with Python libraries, adapted for EPICS software, is going to replace the procedural-based EPICS C libraries previously used at STAR. Advantages of the new approach include stability of operation, code reduction and straightforward project documentation. The first two sections of this paper introduce the STAR experiment, give an overview of the EPICS architecture, and present the use of Python for controls software. Therefore, specific examples, as well as upgrades of user interfaces, are outlined in the following sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of material isotopics and atom number ratio with α-particle spectroscopy for a NIFFTE fission Time Projection Chamber actinide target

In this work, we present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target using α-spectroscopy and mass spectrometry. The double-sided actinide target, with predominantly 239 Pu on one side and 235 U on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is needed to extract an absolute measurement fission cross-section ratio. The 239 Pu/ 235 U atom number ratio was measured with a combination of mass spectrometry and α-spectroscopy with a planar silicon detector achieving uncertainties of less than 1%. Different strategies for estimating isotopic concentration from the α-spectrum are presented to demonstrate the potential of these methods for non-destructive target assay. We found that a combination of fitting spectra with constraints from mass spectrometry, and summing counts in a region of the spectrum provided the most consistent results with the lowest uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The polarization sensitivity of GRETINA

Compton polarimeters have played an important role in the study of nuclear structure physics, but have often been limited in their applications because of relatively low -ray detection efficiency. With the advent of -ray tracking detector arrays, which feature nearly solid angle coverage and the ability to identify the location of Compton-scattering events to within a few millimeters, this limitation can be overcome. Here we present a characterization of the performance of the Gamma Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter using the 24 Mg(p,p') reaction at 2.45 MeV proton energy. We also discuss a new capability added to the simulation package UCGretina to simulate the emission of polarized photons, and compare it to the measured data. Lastly, we use these simulations to predict the performance of the Gamma Ray Energy Tracking Array (GRETA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation of the spatial shift in detector response for polarized protons within a calorimeter

Measurement of the helicity dependent elastic electron-proton scattering cross section provides a key means of investigating parity violation within the proton. However, such measurements exhibit potential instrumental effects associated with the detection of polarized recoiled protons. In particular, spin-orbit interactions within a massive detector induce a systematic spatial shift in the detector signal. In this study, we determine the size of this shift using the Geant4 simulation toolkit. For a typical hadron calorimeter, we found a polarization dependent shift on the order of 0.01-0.1 mm, multiple orders of magnitude smaller than the typical spatial resolution seen in hadronic calorimeters. Additionally, we provide the custom modifications required of the Geant4 source code to implement the quasi-elastic scattering of polarized protons incident on nuclei in the detector. The modifications are readily extendable to generic matter sources, and can be used for the study of additional spin dependent observables in Geant4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First direct observations of gear-changing in a collider

In this work we perform the first demonstration of gear-changing in a real world collider. Gear-changing refers to a collision scheme where each ring of a collider stores a different harmonic number of bunches. These bunches are kept synchronized using different velocities. Such a system has been theorized, but has now been demonstrated using the Double ElectroStatic Ion Ring ExpEriment (DESIREE) in Stockholm Sweden. The experiment was able to demonstrate a gear-changing system, with both four on three bunches and five on four bunches. We determined a measurable parameter that shows a gear-changing system out to $37500$ turns of the slow beam (1 second). We were also able to detect a measurable longitudinal beam-beam interaction. We developed insights into how to control this type of system, opening up new possibilities, and showing that DESIREE can be used for gear-changing research.

43 PARTICLE ACCELERATORS↗

In-flight production of an isomeric beam of 16 N

In this work, an in-flight beam of 16 N was produced via the single-neutron adding ($\textit{d,p}$) reaction in inverse kinematics at the recently upgraded Argonne Tandem Linear Accelerator System (ATLAS) in-flight system. The amount of the 16 N beam which resided in its excited 0.120 MeV $J^\pi$ = 0 – isomeric state (T 1/2 ≈ 5 μs) was determined to be 40(5)% at a reaction energy of 7.9(3) MeV/$\textit{u}$, and 24(2)% at a reaction energy of 13.2(2) MeV/$\textit{u}$. The isomer measurements took place at an experimental station ≈ 30 m downstream of the production target and utilized an Al beam-stopping foil and a HPGe Clover detector. Composite 16 N beam rate determinations were made at the experimental station and the focal plane of the Argonne in-flight radioactive ion-beam separator (RAISOR) with Si ΔE-E telescopes. A Distorted Wave Born Approximation (DWBA) approach was coupled with the known spectroscopic information on 16 N in order to estimate the relative 16 N isomer yields and composite 16 N beam rates. In addition to the observed reaction-energy dependence of the isomer fraction, a large sensitivity to the angular acceptance of the recoils was also observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗