Dynamic Programming Method to Optimally Select Power Distribution System Reliability Upgrades
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Scientific workflows in High Performance Computing (HPC) environments are processing large amounts of data. The storage hierarchy on HPC systems is getting deeper, driven by new technologies (NVRAMs, SSDs, etc.) There is a need for new programming abstractions that allow users to seamlessly manage data at the workflow level on multi-tiered storage systems, and provide optimal workflow performance and use of storage resources. In previous work, we introduced a software architecture Managing Data on Tiered Storage for Scientific Workflows (MaDaTS) that used a Virtual Data Space (VDS) abstraction to hide the complexities of the underlying storage system while allowing users to control data management strategies. In this article, we detail the data-centric programming abstractions that allow users to manage a workflow around its data on the storage layer. The programming abstractions simplify data management for scientific workflows on multi-tiered storage systems, without affecting workflow performance or storage capacity. We measure the overheads and effectiveness introduced by the programming abstractions of MaDaTS. Our results show that these abstractions can optimally use the storage capacity in lesser capacity storage tiers, and simplify data management without adding any performance overheads.
Under the Reactor Product Line (RPL) of DOE/NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an SFR System Analysis Module is being developed at Argonne National Laboratory for whole-plant safety analysis. This tool will simulate tightly coupled physical phenomena – including nuclear fission, heat transfer, fluid dynamics, and thermal-mechanical response – in SFR structures, systems, and components. It is based on the MOOSE (Multi-physics Object-Oriented Simulation Environment) framework, which relies upon open-source libraries such as libMesh and PETSc for mesh generation, finite element analysis, and numerical solutions. This development is a coordinated effort along with the development of RELAP-7, which is an advanced safety analysis tool for light-water reactors developed at Idaho National Laboratory. The SFR Module is aimed to model and simulate the SFR systems with much higher fidelity and with well-defined and validated prediction capabilities. It will provide fast-running, modest-fidelity, whole-plant transient analyses capability, which is essential for fast turnaround design scoping and engineering analyses.
Most demand response programs focus primarily on commercial and industrial loads. The sheer number of decision-influencing variables combined with a lack of a comprehensive understanding of human behavior make it difficult to develop response programs that encourage greater residential consumer participation. This paper presents a multi-criteria decision making approach using actual survey data for identifying user preferences. The novelty of the work is in considering functionality, cost, and carbon emissions for a given set of home appliances toward energy management. The paper explains the design methodologies used to prioritize the preferences from 1023 survey participants. Furthermore, the results are expected to inform the design of Home Energy Management Systems (HEMS) for participating in demand response programs.
This document is a summarization of the report, Developing Secure Power Systems Professional Competence: Alignment and Gaps in Workforce Development Programs, the final report for phase 2 of the SPSP (DOE workforce study) project.
This report supplements the document, "Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems," issued in a revised version in April 2016 (see [4]), which will include the photovoltaic (PV) smoothing application for an energy storage system (ESS). This report provides the background and documentation associated with the determination of a duty cycle for an ESS operated in a PV smoothing application for the purpose of measuring and expressing ESS performance in accordance with the ESS performance protocol. ACKNOWLEDGEMENTS The authors gratefully acknowledge the support of Dr. Imre Gyuk, program manager for the DOE Energy Storage Systems Program. The authors would also like to express their appreciation to all the stakeholders who participated as members of the PV Smoothing Subgroup. Without their thoughtful input and recommendations, the definitions, metrics, and duty cycle provided in this report would not have been possible. A complete listing of members of the PV Smoothing Subgroup appears in the first chapter of this report. Special recognition should go to the staffs at Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) in collaborating on this effort. In particular, Mr. David Conover and Dr. Vish Viswanathan of PNNL and Dr. Summer Ferreira of SNL were especially helpful in their suggestions for the determination of a duty cycle for the PV Smoothing application.
Driven by the need to find alternative accelerators which can viably replace GPUs in next-generation Supercomputing systems, this paper proposes a methodology to enable agile application/hardware co-design. The application-first methodology provides the ability to come up with design of accelerators while working with real-world workloads, available accelerators, and system software. The iterative design process targets a set of kernels in a workload for performance estimates that can prune the design space for later phases of detailed architectural evaluations. To this effect, in this paper, a novel data-parallel device model is introduced that simulates the latency of performance-sensitive operations in an accelerator including data transfers and kernel computation using multi-core CPUs. The use of off-the-shelf simulators, such as pre-RTL simulator Aladdin or multiple tools available for exploring the design of deep neural network accelerators (e.g., Timeloop) is demonstrated for evaluation of various accelerator designs using applications with realistic inputs. Examples of multiple device configurations that are instantiable in a system are explored to evaluate the performance benefit of deploying novel accelerators. The proposed device is integrated with a programming model and system software to potentially explore the impacts of high-level programming languages/compilers and low-level effects such as task scheduling on multiple accelerators. We analyze our methodology for a set of applications that represent high-performance computing (HPC) and graph analytics. The applications include a computational chemistry kernel realized using tensor contractions, triangle counting, GraphSAGE and Breadth-first Search. These applications include kernels such as dense matrix-dense matrix multiplication, sparse matrix-spare matrix multiplication, and sparse matrix-dense vector multiplication. Our results indicate potential performance benefits and insights for system design by including accelerators that realize these kernels along-side general purpose accelerators.
Machine drives are versatile systems that can be programmed to emulate a variety of mechanical loads. In this paper, we walk through the modeling and control framework of a shaft-coupled dual-motor drive system that is programmed to emulate a fictitious mechanical system. We quantitatively evaluate the control performance of such a system and derive a theoretical limit that explains its inaccuracy at high operating frequencies. To overcome this problem, we propose an alternate control structure that achieves the same control objective at high frequencies as well. After suitable adjustments are made to the controller, we validate its performance using simulation results.
The project "Integrated Oxygen Production and CO 2 Separation through Chemical Looping Combustion with Oxygen Uncoupling" focused on advancing fluidized bed chemical looping combustion technology to semi-pilot scale. An important aspect of technology scale-up is production of well-performing oxygen carrier materials economically and at a scale sufficient for industrial-scale systems. Under this program, a new technique for oxygen carrier production was developed and a prototype system capable of producing up to 150 lb per batch of oxygen carrier was constructed. Chemical looping combustion testing was performed in a large process development unit designed for operation at more than 200 kW using coal as fuel. Complementary evaluation of carbon conversion pathways was conducted and quantitative analysis of the fate of carbon in a CLOU-based chemical looping system was performed. As an aid for design, optimization, troubleshooting and scale-up, robust CFD models for fluidized bed chemical looping combustion systems were developed.
The Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016 Precursor Analysis Report leverages publicly available information about the December 2016 cyber attack against the Ukrainian Ukrenergo electric transmission utility and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. Industroyer is a modular malware framework designed to deploy several Industrial Control System (ICS) protocol-specific attack payloads to disrupt electricity distribution. Adversaries deployed Industroyer within the target network on a Microsoft Windows endpoint capable of directly manipulating or communicating with ICS. Industroyer abuses the functionality of a targeted ICS’s legitimate control system to achieve its intended impact. Adversaries likely first gained access to Ukrenergo enterprise networks in early 2016 after a successful spearphishing campaign against organizations in the electric power sector. Adversaries then began capturing credentials beginning on 1 December 2016. This allowed access to the ICS environment at the Pivnichna electric transmission substation outside Kyiv through a device dual-homed on the Information Technology (IT) and ICS networks. Adversaries conducted discovery, targeting, and access to this device using information and previously captured credentials from compromised enterprise IT machines. Finally, the adversaries deployed and launched the Industroyer malware just before midnight on 17 December. By midnight, Ukrenergo had lost control of a targeted substation, resulting in electric power outages for over an hour in the city of Kyiv and the Kyiv region. Researchers and analysts identified 31 unique techniques (used in a sequence of 33 steps) utilized during the attack with a total of 846 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-nine of the identified techniques used during the Industroyer cyber attack were precursors to the triggering event. Analysis identified 548 observables associated with these precursor techniques, 353 of which were assessed to have an increased likelihood of being perceived in the 300 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.
One promising method for reducing fuel consumption and emissions, particularly in heavy duty trucks, is platooning. As the distance between vehicles decreases, the following vehicles will experience less aerodynamic drag on the front of the vehicle. However, reducing the velocity of the air contacting the front of the vehicle could have adverse effects on the temperature of the engine. To compensate for this effect, the energy consumption of the engine cooling system might increase, ultimately limiting the overall improvements obtained with platooning. Understanding the coupling between drag reduction and engine cooling load requirement is key for successfully implementing platooning strategies. Additionally, in a Connected and Automated Vehicle (CAV) environment, where information of the future engine load becomes available, the operation of the cooling system can be optimized in order to achieve the maximum fuel consumption reduction. In this paper, a control-oriented physics-based model for the engine cooling loop of a Volvo engine is developed and validated against road data. Starting from the validated model, an optimal control problem for the coolant system is formulated considering the tradeoff between the tracking of the engine temperature setpoint and the corresponding fuel consumption under different trailing distances. To compare the coolant system performance, Dynamic Programming (DP) is used to determine the global optimal solution for the coolant system actuator. The coupling between optimal cooling system operation and reduction in ram air are evaluated by comparing the results obtained from the DP under different platooning conditions against the unrestricted scenario. In addition, the paper analyzes the changes in the tradeoff between fuel consumption and setpoint tracking for different vehicle distances. This analysis will provide useful insight on the sensitivity of the coolant system controller calibration to the platoon distance.
This document contains a description of the Advanced Simulation and Computing Program's Capability Computing System Governance Model. Objectives of the Governance Model are to ensure that the capability system resources are allocated on a priority-driven basis according to the Program requirements; and to utilize ASC Capability Systems for the large capability jobs for which they were designed and procured.
Overview of the DOE Office of Nuclear Energy program for integrated energy systems in support of the MARVEL technology review (October 19-20, 2022).
Boise State University’s (BSU) Cyber Operations and Resilience CORe program was intentionally designed so that any student, especially non-traditional and non-technical students, with an interest in cybersecurity could have an education and training pathway to enter the cyber workforce. The CORe curriculum focuses on teaching students how to design, apply, and improve cybersecurity through the interaction of people, processes, and technology. CORe is a stackable curriculum with elective credit hours and options for various academic and industry certificates and certifications that enable students to customize their unique career pathway. The CORe program guides students to think about the system being managed, the risks presented, and the dynamic intersection of system elements when considering how to incorporate resilience frameworks in achieving a resilient system. By developing systems thinking, the students gain an understanding of the interdependencies interacting with the operational system. Further, the CORe program encourages students to integrate cybersecurity knowledge with models and frameworks found in other academic disciplines through a unifying systems approach. CORe is designed around the realities of today’s broad cyber landscape: that breaches will occur in any system over time and proactive design of resilience into systems to detect, respond, and recover in a timely and orderly manner is critical. Students are taught to think holistically about cybersecurity focusing on all system elements. CORe is not a traditional cybersecurity degree. CORe is distinguished by the non-traditional engineering, computer science approach to cybersecurity education with the singular focus on infusing resilience operations and transdisciplinary systems thinking principles throughout the curriculum.
A multiyear power system R&D program was completed with the objective of developing an off-road hybrid heavy duty diesel engine with front end accessory drive-integrated energy storage. This system was validated to deliver 10.5–25.6% reduction in fuel consumption over current Tier 4 Final-based 18L diesel engines, over various off-road machine application cycles. The power system consisted of a downsized heavy-duty diesel 13L engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, thermal barrier coatings, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy assisting and recovery through both mechanical and electrical systems. Following the concept definition, design, and analysis phases of the program, the final phase focused on building and validating the performance and efficiency in laboratory tests. While aspects of the system such as start/stop and reduced off-road cooling package energy losses were only analytically evaluated, the main 13L concept engine with full hybrid system was successfully built and tested in steady-state and in transient certification and real-world application cycles. Extensive simulations in Caterpillar's DYNASTY™ software environment utilized the validation test data to assess performance more fully and confidently over varied cycles and strategies. An average fuel consumption reduction of 17.9% was realized, and the majority (~13%) of the benefit stemmed from the core concept 13L engine. In conclusion, a total cost of ownership analysis provides context to commercial viability and where adoption focus should be placed.
Optimal design applications are often modeled by using categorical variables to express discrete design decisions, such as material types. A disadvantage of using categorical variables is the lack of continuous relaxations, which precludes the use of modern integer programming techniques. We show how to express categorical variables with standard integer modeling techniques, and we illustrate this approach on a load-bearing thermal insulation system. The system consists of a number of insulators of different materials and intercepts that minimize the heat flow from a hot surface to a cold surface. Our new model allows us to employ black-box modeling languages and solvers and illustrates the interplay between integer and nonlinear modeling techniques. We present numerical experience that illustrates the advantage of the standard integer model.
The goal of the program is to develop 'LOW COST THIN FILM BUILDING-INTEGRATED PV SYSTEMS'. Major focus was on developing low cost solution for the commercial BIPV and rooftop PV market and meet DOE LCOE goal for the commercial market segment of 9-12 cents/kWh for 2010 and 6-8 cents/kWh for 2015. We achieved the 2010 goal and were on track to achieve the 2015 goal. The program consists of five major tasks: (1) modules; (2) inverters and BOS; (3) systems engineering and integration; (4) deployment; and (5) project management and TPP collaborative activities. We successfully crossed all stage gates and surpassed all milestones. We proudly achieved world record stable efficiencies in small area cells (12.56% for 1cm2) and large area encapsulated modules (11.3% for 800 cm2) using a triple-junction amorphous silicon/nanocrystalline silicon/nanocrystalline silicon structure, confirmed by the National Renewable Energy Laboratory. We collaborated with two inverter companies, Solectria and PV Powered, and significantly reduced inverter cost. We collaborated with three universities (Syracuse University, University of Oregon, and Colorado School of Mines) and National Renewable Energy Laboratory, and improved understanding on nanocrystalline material properties and light trapping techniques. We jointly published 50 technical papers in peer-reviewed journals and International Conference Proceedings. We installed two 75kW roof-top systems, one in Florida and another in New Jersey demonstrating innovative designs. The systems performed satisfactorily meeting/exceeding estimated kWh/kW performance. The 50/50 cost shared program was a great success and received excellent comments from DOE Manager and Technical Monitor in the Final Review.
To help effectively plan the management and modernization of their large and diverse fleets of vehicles, the Program Executive Office Ground Combat Systems (PEO GCS) and the Program Executive Office Combat Support and Combat Service Support (PEO CS &CSS) commissioned the development of a large - scale portfolio planning optimization tool. This software, the Capability Portfolio Analysis Tool (CPAT), creates a detailed schedule that optimally prioritizes the modernization or replacement of vehicles within the fleet - respecting numerous business rules associated with fleet structure, budgets, industrial base, research and testing, etc., while maximizing overall fleet performance through time. This report contains a description of the organizational fleet structure and a thorough explanation of the business rules that the CPAT formulation follows involving performance, scheduling, production, and budgets. This report, which is an update to the original CPAT domain model published in 2015 (SAND2015 - 4009), covers important new CPAT features. This page intentionally left blank