Bayesian Surrogates for Modeling Natural Gas Price Uncertainty in a Realistic California Power System Test Case
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An analytical model of the silicon solar cells for high illumination is being used to design cells for different concentration factors. It is shown that a cell design using one centimeter length grid fingers would have an efficiency at 100 suns that is 90% of the efficiency of a typical cell at one sun. This may require about 30 fingers per centimeter. A decrease in efficiency comes from the greater coverage of the surface with grids as the concentration increases. The importance of base material resistivity on cell design for high concentration is outlined.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Linear approximation commonly used in solving alternating-current optimal power flow (AC-OPF) simplifies the system models but incurs accumulated voltage errors in large power networks. Such errors will make the primal-dual type gradient algorithms converge to solutions with voltage violation. In this paper, we improve a recent hierarchical OPF algorithm that rested on primal-dual gradients evaluated with a linearized distribution power flow model. Specifically, we propose a more accurate gradient evaluation method based on an unbalanced three-phase nonlinear distribution power flow model to mitigate the errors arising from linearization. The resultant gradients feature a blocked structure that enables our development of an improved hierarchical primal-dual algorithm to solve the OPF problem. Numerical results on the IEEE 123-bus test feeder and a 4,518-node test feeder show that the proposed method can enhance voltage safety at comparable computational efficiency with the linearized algorithm.
Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the Western System Coordinating Council (WSCC) 9-bus test system using synthetic multi-device outage scenarios. Towards integrating our modeling framework with real threats and more realistic power systems, we explore applying hybrid dynamics to power systems. Our work is applied to basic RL circuits with the ultimate goal of using the methodology to model protective tripping schemes in the grid. Finally, we survey mitigation techniques for HEMP threats and describe a GIS application developed to create threat scenarios in a grid with geographic detail.
For distributed generation installations, the transient response of the power generation system is critical to meet power quality (voltage and frequency) requirements. Transient models for gas turbine and supercritical carbon dioxide (sCO2) power cycle were integrated for an exhaust heat recovery bottoming cycle system for a distributed generation application. The transient model for the SGT-750 Siemens gas turbine was a ‘black-box’ functional mockup interface (FMI) model developed by Siemens Industrial Turbomachinery in $Finsp\mathring{a}ng$, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8 °C.
This article proposes a cascading failure simulation (CFS) method and a hybrid machine learning method for vulnerability analysis of integrated power-gas systems (IPGSs). The CFS method is designed to study the propagating process of cascading failures between the two systems, generating data for machine learning with initial states randomly sampled. The proposed method considers generator and gas well ramping, transmission line and gas pipeline tripping, island issue handling and load shedding strategies. Then, a hybrid machine learning model with a combined random forest (RF) classification and regression algorithms is proposed to investigate the impact of random initial states on the vulnerability metrics of IPGSs. Extensive case studies are carried out on three test IPGSs to verify the proposed models and algorithms. Simulation results show that the proposed models and algorithms can achieve high accuracy for the vulnerability analysis of IPGSs.
The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.
This work presents a novel deep learning model for early, accurate, and robust detection, recognition, and temporal localization of multi-type events in large-scale power systems. The proposed method develops a unified 1-D fully convolutional network (FCN) model that takes time series of raw frequency signals measured from a power system as input, extracts distinguishing features, and predicts at every temporal point in the time series if an event is happening and what the type of the event is. Compared to existing methods, the proposed model eliminates the necessity for hand-crafted feature extraction or complicated data pre-processing, can flexibly handle input signals of arbitrary length, and precisely infer the event occurrence time. Most importantly, the model is intentionally trained with incomplete patterns, such that it is more robust to partial features of an event which is common in real-world online recognition, resulting in early alarm for power system failures. Extensive experimental results demonstrate that the proposed method achieves superior performance to the state-of-the-art, and also shows strong robustness to noise and system oscillations.
This paper combines and applies concepts from several researchers to outline an alternative framework to plan power systems for resource adequacy needs, which we call Adaptive Stress Period Planning (ASPP). It first provides background information regarding least-cost planning objectives and the challenge of balancing an increasing need for model representation with computational intensity as power systems evolve in complexity. Next, it motivates the opportunity for a new paradigm by outlining challenges of frameworks in use today that rely on aggregate capacity heuristics (i.e., capacity credits and planning reserve margins). Subsequently, it lays out main process details of ASPP, which more directly represents spatial and temporal dynamics of power systems in a capacity expansion model with a process to adaptively select risk periods. The paper concludes with a summary of the approach, its benefits, and opportunities for future work.
NASA Glenn Research Center, in collaboration with the aerospace industry and academia, has begun the development of technology for a future hybrid-wing body electric airplane with a turboelectric distributed propulsion (TeDP) system. It is essential to design a subscale system to emulate the TeDP power grid, which would enable rapid analysis and demonstration of the proof-of-concept of the TeDP electrical system. This paper describes how small electrical machines with their controllers can emulate all the components in a TeDP power train. The whole system model in Matlab/Simulink was first developed and tested in simulation, and the simulation results showed that system dynamic characteristics could be implemented by using the closed-loop control of the electric motor drive systems. Then we designed a subscale experimental system to emulate the entire power system from the turbine engine to the propulsive fans. Firstly, we built a system to emulate a gas turbine engine driving a generator, consisting of two permanent magnet (PM) motors with brushless motor drives, coupled by a shaft. We programmed the first motor and its drive to mimic the speed-torque characteristic of the gas turbine engine, while the second motor and drive act as a generator and produce a torque load on the first motor. Secondly, we built another system of two PM motors and drives to emulate a motor driving a propulsive fan. We programmed the first motor and drive to emulate a wound-rotor synchronous motor. The propulsive fan was emulated by implementing fan maps and flight conditions into the fourth motor and drive, which produce a torque load on the driving motor. The stator of each PM motor is designed to travel axially to change the coupling between rotor and stator. This feature allows the PM motor to more closely emulate a wound-rotor synchronous machine. These techniques can convert the plain motor system into a unique TeDP power grid emulator that enables real-time simulation performance using hardware-in-the-loop (HIL).
Faults in the transmission grid have led to reduced power generation from power electronics resources that are typically not connected to the faulted transmission line. In many of the cases, partial loss of power is observed within the power electronics resources like large photovoltaic (PV) power plants. This phenomena is not captured in existing simulation models and/or simulators. High-fidelity switched system electromagnetic transient (EMT) dynamic models of PV power plants can improve the fidelity of models available for accurate analysis of the impact on PV plants during simulation of faults. However, these models are extremely computationally expensive and take a long time to simulate. Long simulation times limit the ability to use these models as larger regions are studied in EMT simulations with more power electronics resources. In this paper, numerical simulation algorithms are combined with high-performance computing techniques and applied to the high-fidelity switched system EMT model of PV plants. Using these techniques, a speed-up of up to 58x is obtained, while preserving the accuracy of the simulation at greater than 98%.
Energy storage has been proven to yield positive effects on planning, operation and control of electric grids. It has become a crucial task to properly model the energy storage systems (ESS) under the framework of grid optimization on transmission and distribution networks including microgrids. This paper presents a review on mathematical models and test cases of ESSs used for grid optimization studies, where the network constraints of power systems are included. The existing ESS models are mainly classified into two categories – linear and nonlinear models. The two main categories are further divided into several subcategories respectively; such as mixed-integer linear and convex nonlinear sub-categories. Based on the review and discussions, this paper aims at providing suggestions for choosing proper ESS models for specific grid optimization studies considering the chosen power network model.
The purpose of the proposed study is to establish whether changes in gravitational loading have a direct effect on osteoblasts to regulate TGF-6 expression. The effects of spaceflight and reloading on TGF-B MRNA and peptide levels will be studied in a newly developed line of immortalized human fetal osteoblasts (HFOB) transfected with an SV-40 temperature dependent mutant to generate proliferating, undifferentiated hFOB cells at 33-34 C and a non-proliferating, differentiated HFOB cells at 37-39'C. Unlike previous cell culture models, HFOB cells have unlimited proliferative capacity yet can be precisely regulated to differentiate into mature cells which express mature osteoblast function. If isolated osteoblasts respond to changes in mechanical loading in a manner similar to their response in animals, the cell system could provide a powerful model to investigate the signal transduction pathway for gravitational loading.
Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.
Abstract— Power system stability is a critical concern, with respect to the increasing distributed energy resources, microgrids, and emphasis on enhancing resiliency. For stability analysis and evaluation, modeling and simulation capabilities are important. In this paper, the authors’ previous work on modeling transformer inrush dynamics is improved with a new formulation of the key equation that converts the dynamic-phasor into real-time value. Simulation results in an electromechanical time-scale are compared with PSCAD results in an electromagnetic time-scale to demonstrate the improvement. The impact of simulation step size is discussed. A bug in PSCAD transformer setting that leads to incorrect magnetizing flux and current under Delta winding type is identified and reported. In addition, explanations and analysis are provided on two modeling techniques utilized since the previous work. This work is being incorporated into the next release of GridLAB-D. The improved transformer inrush calculation enables more accurate predictions of current amplitudes for analyzing the dynamics of distribution operation and control.