Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Cross sections for ionization of K, L and M shells of atoms by impact of electrons and positrons with energies up to 1 GeV: Analytical formulas

Analytical formulas are presented for the easy calculation of cross sections for ionization of K, L and M shells of neutral atoms by impact of electrons and positrons with kinetic energies up to 1 GeV. Each formula contains a number of parameters that are characteristic of the element, the active electron shell and the projectile particle. The values of these parameters were determined by fitting the cross section values in an extensive database that was calculated recently by means of a composite algorithm that combines the distorted-wave and plane-wave Born approximations. Tables of parameter values are given for all elements, from hydrogen (Z=1) to einsteinium (Z=99). The proposed analytical expressions yield ionization cross sections that agree with those in the numerical database to within about 1%, except for projectiles with near-threshold energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Positron emission tomography study on pancreatic somatostatin receptors in normal and diabetic rats with {sup 68}Ga-DOTA-octreotide: A potential PET tracer for beta cell mass measurement

Highlights: •PET images showed high uptake of {sup 68}Ga-DOTA-octreotide in the normal pancreas. •{sup 68}Ga-DOTA-octreotide specifically binds to somatostatin receptors in the pancreas. •The pancreatic uptake of {sup 68}Ga-DOTA-octreotide was decreased in the diabetic rats. •{sup 68}Ga-DOTA-octreotide could be a candidate PET probe to measure the beta cell mass. -- Abstract: Diabetes mellitus (DM) is a metabolic disorder characterized by hyperglycemia, and the loss or dysfunction of pancreatic beta cells has been reported before the appearance of clinical symptoms and hyperglycemia. To evaluate beta cell mass (BCM) for improving the detection and treatment of DM at earlier stages, we focused on somatostatin receptors that are highly expressed in the pancreatic beta cells, and developed a positron emission tomography (PET) probe derived from octreotide, a metabolically stable somatostatin analog. Octreotide was conjugated with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), a chelating agent, and labeled with {sup 68}Gallium ({sup 68}Ga). After intravenous injection of {sup 68}Ga-DOTA-octreotide, a 90-min emission scan of the abdomen was performed in normal and DM model rats. The PET studies showed that {sup 68}Ga-DOTA-octreotide radioactivity was highly accumulated in the pancreas of normal rats and that the pancreatic accumulation was significantly reduced in the rats administered with an excess amount of unlabeled octreotide or after treatment with streptozotocin, which was used for the chemical induction of DM in rats. These results were in good agreement with the ex vivo biodistribution data. These results indicated that the pancreatic accumulation of {sup 68}Ga-DOTA-octreotide represented specific binding to the somatostatin receptors and reflected BCM. Therefore, PET imaging with {sup 68}Ga-DOTA-octreotide could be a potential tool for evaluating BCM.

60 APPLIED LIFE SCIENCES↗

Nicotine Blocks Brain Estrogen Synthase (Aromatase): In Vivo Positron Emission Tomography Studies in Female Baboons

Cigarette smoking and nicotine have complex effects on human physiology and behavior, including some effects similar to those elicited by inhibition of aromatase, the last enzyme in estrogen biosynthesis. We report the first in vivo primate study to determine whether there is a direct effect of nicotine administration on brain aromatase. Brain aromatase availability was examined with positron emission tomography and the selective aromatase inhibitor [{sup 11}C]vorozole in six baboons before and after exposure to IV nicotine at .015 and .03 mg/kg. Nicotine administration produced significant, dose-dependent reductions in [{sup 11}C]vorozole binding. The amygdala and preoptic area showed the largest reductions. Plasma levels of nicotine and its major metabolite cotinine were similar to those found in cigarette smokers. Nicotine interacts in vivo with primate brain aromatase in regions involved in mood, aggression, and sexual behavior.

60 APPLIED LIFE SCIENCES↗

Radiolabelling and positron emission tomography of PT70, a time-dependent inhibitor of InhA, the Mycobacterium tuberculosis enoyl-ACP reductase

PT70 is a diaryl ether inhibitor of InhA, the enoyl-ACP reductase in the Mycobacterium tuberculosis fatty acid biosynthesis pathway. It has a residence time of 24 min on the target, and also shows antibacterial activity in a mouse model of tuberculosis infection. Due to the interest in studying target tissue pharmacokinetics of PT70, we developed a method to radiolabel PT70 with carbon-11 and have studied its pharmacokinetics in mice and baboons using positron emission tomography.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of adsorption and mechanical strength of 13X zeolite mixtures with phyllosilicate binders using molecular dynamics simulation and positron annihilation spectroscopy

There is growing interest in developing zeolites with novel internal structures that have optimal adsorptive capacity and high mechanical strength, while offering advantages, such as being light weight. We integrate computational and experimental methods to explore the effect of binder/zeolite types, and weight percentages on the mechanical strength of 13X zeolite and adsorption capacities of N 2 , H 2 O, and CO 2 for additive manufacturing (AM) applications with the goal of maximizing both adsorption and strength. Zeolite 13X mixtures and phyllosilicate binders (either bentonite or kaolin) are combined using molecular dynamics (MD) simulations to create structures with various binder/zeolite weight percentages. Further, adsorption capabilities and mechanical strength are assessed using the grand canonical Monte Carlo (GCMC) and ReaxFF modules, respectively. Our modeling shows that an optimized zeolite/binder ratio for N 2 adsorption is around 15 wt% for kaolin and roughly 10 wt% for bentonite. The resulting parameters can be applied to facilitate macro-scale computational fluid dynamics (CFD) and finite element method (FEM) simulations of an AM zeolite structure. We also performed Positron Annihilation Lifetime Spectroscopy (PALS) measurements on zeolite samples to explore the effect of changes in the internal volume. The results show an inverse relationship between the free volume and the solid loading and adding a binder changes the morphology of the zeolite-binder compound and decreases open-volume area significantly.

36 MATERIALS SCIENCE↗

Intrathoracic Patterns of Failure for Non-Small-Cell Lung Cancer With Positron-Emission Tomography/Computed Tomography-Defined Target Delineation

Purpose: Dosimetric studies suggested several advantages to defining the radiotherapy target by using positron-emission tomography (PET)/computed tomography (CT) compared with CT alone. We investigated patterns of treatment failure in patients treated to a PET-defined radiotherapy target and evaluated the effect of standardized uptake value (SUV) on recurrence after radiotherapy. Methods and Materials: Thirty-five patients with non-small-cell lung cancer who underwent PET/CT simulation for definitive radiotherapy were included. The PET/CT scans were obtained with patients in the treatment position with custom immobilization for use in radiation treatment planning. Nine to 11 regions of interest (ROIs) were identified for each patient, including the primary tumor and regional nodes. Maximum SUV, volume, and mean dose received were recorded for each ROI, and follow-up scans were used to evaluate for recurrence in each ROI. Results: We identified 353 ROIs from 35 patients; 5.7% of patients developed isolated out-of-field recurrences. Recursive partitioning analysis was used to divide ROIs into low, intermediate, and high risk by using volume and SUV. All low-risk ROIs with volumes less than 1.2 cm{sup 3} were recurrence free compared with 73% of intermediate-risk ROIs (volume {>=}1.2 cm{sup 3}; SUV {<=}13.8) and 29% of high-risk ROIs (SUV > 13.8). Conclusion: Limiting the target volume to predominantly PET-positive disease resulted in a low rate of isolated out-of-field recurrences. The SUV and volume were predictors of recurrence. Recursive partitioning analysis identified SUVs greater than 13.8 as the best identifier of ROIs at the greatest risk of recurrence; control rates for this subgroup did not show a dose-response relationship within the range of doses administered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance of Positron Emission Tomography/Computed Tomography for Radiation Therapy

Recent advances in radiation delivery techniques, such as intensity-modulated radiation therapy, provide unprecedented ability to exquisitely control three-dimensional dose distribution. Development of on-board imaging and other image-guidance methods significantly improved our ability to better target a radiation beam to the tumor volume. However, in reality, accurate definition of the location and boundary of the tumor target is still problematic. Biologic and physiologic imaging promises to solve the problem in a fundamental way and has a more and more important role in patient staging, treatment planning, and therapeutic assessment in radiation therapy clinics. The last decade witnessed a dramatic increase in the use of positron emission tomography and computed tomography in radiotherapy practice. To ensure safe and effective use of nuclide imaging, a rigorous quality assurance (QA) protocol of the imaging tools and integration of the imaging data must be in place. The application of nuclide imaging in radiation oncology occurs at different levels of sophistication. Quantitative use of the imaging data in treatment planning through image registration and standardized uptake value calculation is often involved. Thus, QA should not be limited to the performance of the scanner, but should also include the process of implementing image data in treatment planning, such as data transfer, image registration, and quantitation of data for delineation of tumors and sensitive structures. This presentation discusses various aspects of nuclide imaging as applied to radiotherapy and describes the QA procedures necessary for the success of biologic image-guided radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

L-[METHYL-{sup 11}C] Methionine Positron Emission Tomography for Target Delineation in Malignant Gliomas: Impact on Results of Carbon Ion Radiotherapy

Purpose: To assess the importance of {sup 11}C-methionine (MET)-positron emission tomography (PET) for clinical target volume (CTV) delineation. Methods and Materials: This retrospective study analyzed 16 patients with malignant glioma (4 patients, anaplastic astrocytoma; 12 patients, glioblastoma multiforme) treated with surgery and carbon ion radiotherapy from April 2002 to Nov 2005. The MET-PET target volume was compared with gross tumor volume and CTV, defined by using computed tomography/magnetic resonance imaging (MRI). Correlations with treatment results were evaluated between positive and negative extended volumes (EVs) of the MET-PET target for CTV. Results: Mean volumes of the MET-PET targets, CTV1 (defined by means of high-intensity volume on T2-weighted MRI), and CTV2 (defined by means of contrast-enhancement volume on T1-weighted MRI) were 6.35, 264.7, and 117.7 cm{sup 3}, respectively. Mean EVs of MET-PET targets for CTV1 and CTV2 were 0.6 and 2.2 cm{sup 3}, respectively. The MET-PET target volumes were included in CTV1 and CTV2 in 13 (81.3%) and 11 patients (68.8%), respectively. Patients with a negative EV for CTV1 had significantly greater survival rate (p = 0.0069), regional control (p = 0.0047), and distant control time (p = 0.0267) than those with a positive EV. Distant control time also was better in patients with a negative EV for CTV2 than those with a positive EV (p = 0.0401). Conclusions: For patients with malignant gliomas, MET-PET has a possibility to be a predictor of outcome in carbon ion radiotherapy. Direct use of MET-PET fused to planning computed tomography will be useful and yield favorable results for the therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Five Segmentation Tools for {sup 18}F-Fluoro-Deoxy-Glucose-Positron Emission Tomography-Based Target Volume Definition in Head and Neck Cancer

Purpose: Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with {sup 18}F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may improve definition of the gross tumor volume (GTV). In this study, five methods for tumor delineation on FDG-PET are compared with CT-based delineation. Methods and Materials: Seventy-eight patients with Stages II-IV squamous cell carcinoma of the head and neck area underwent coregistered CT and FDG-PET. The primary tumor was delineated on CT, and five PET-based GTVs were obtained: visual interpretation, applying an isocontour of a standardized uptake value of 2.5, using a fixed threshold of 40% and 50% of the maximum signal intensity, and applying an adaptive threshold based on the signal-to-background ratio. Absolute GTV volumes were compared, and overlap analyses were performed. Results: The GTV method of applying an isocontour of a standardized uptake value of 2.5 failed to provide successful delineation in 45% of cases. For the other PET delineation methods, volume and shape of the GTV were influenced heavily by the choice of segmentation tool. On average, all threshold-based PET-GTVs were smaller than on CT. Nevertheless, PET frequently detected significant tumor extension outside the GTV delineated on CT (15-34% of PET volume). Conclusions: The choice of segmentation tool for target-volume definition of head and neck cancer based on FDG-PET images is not trivial because it influences both volume and shape of the resulting GTV. With adequate delineation, PET may add significantly to CT- and physical examination-based GTV definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-Fluorodeoxyglucose Positron Emission Tomography-Based Assessment of Local Failure Patterns in Non-Small-Cell Lung Cancer Treated With Definitive Radiotherapy

Purpose: To assess the pattern of local failure using {sup 18}F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) scans after radiotherapy (RT) in non-small-cell lung cancer (NSCLC) patients treated with definitive RT whose gross tumor volumes (GTVs) were defined with the aid of pre-RT PET data. Method and Materials: The data from 26 patients treated with involved-field RT who had local failure and a post-RT PET scan were analyzed. The patterns of failure were visually scored and defined as follows: (1) within the GTV/planning target volume (PTV); (2) within the GTV, PTV, and outward; (3) within the PTV and outward; and (4) outside the PTV. Local failure was also evaluated as originating from nodal areas vs. the primary tumor. Results: We analyzed 34 lesions. All 26 patients had recurrence originating from their primary tumor. Of the 34 lesions, 8 (24%) were in nodal areas, 5 of which (63%) were marginal or geographic misses compared with only 1 (4%) of the 26 primary recurrences (p = 0.001). Of the eight primary tumors that had received a dose of <60 Gy, six (75%) had failure within the GTV and two (25%) at the GTV margin. At doses of {>=}60 Gy, 6 (33%) of 18 had failure within the GTV and 11 (61%) at the GTV margin, and 1 (6%) was a marginal miss (p < 0.05). Conclusion: At lower doses, the pattern of recurrences was mostly within the GTV, suggesting that the dose might have been a factor for tumor control. At greater doses, the treatment failures were mostly at the margin of the GTV. This suggests that visual incorporation of PET data for GTV delineation might be inadequate, and more sophisticated approaches of PET registration should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of Positron Emission Tomography Standard Uptake Value and Pathologic Specimen Size in Cancer of the Head and Neck

Purpose: To correlate positron emission tomography (PET) standard uptake value (SUV) with pathologic specimen size in patients with head-and-neck cancers. Methods and Materials: Eighteen patients with Stage II-IVB head-and-neck cancer with 27 tumors who underwent PET and computed tomography (CT) imaging of the head and neck followed by surgical resection were selected for this study. Various SUV thresholds were examined, including the software default (SUV{sub def}), narrowing the window by 1 standard deviation (SD) of the maximum (SUV-1SD), and SUV cutoff values of 2.5 or greater (SUV2.5) and 40% or greater maximum (SUV40). Volumetric pathologic data were available for 12 patients. Tumor volumes based on pathologic examination (gold standard), CT, SUV{sub def}, SUV-1SD, SUV2.5, and SUV40 were analyzed. Results: PET identified five tumors not seen on CT. The sensitivity of PET for identifying primary tumors was 94% (17 of 18). The Sensitivity of PET for staging the neck was 90% (9 of 10), whereas the specificity was 78% (7 of 9). The SUV2.5 method was most likely to overestimate tumor volume, whereas SUV{sub def} and SUV-1SD were most likely to underestimate tumor volume. Conclusions: The PET scan provides more accurate staging of primary tumors and nodal metastases for patients with advanced head-and-neck cancer than CT alone. Compared with the gold standard, significant variability exists in volumes obtained by using various SUV thresholds. A combination of clinical, CT, and PET data should continue to be used for optimal treatment planning. The SUV40 method appears to offer the best compromise between accuracy and reducing the risk of underestimating tumor extent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Positron Emission Tomography Compared With Mediastinoscopy for Delineating Involved Lymph Nodes in Stage III Lung Cancer: Insights for Radiotherapy Planning From a Surgical Cohort

Purpose: Mediastinoscopy is routinely carried out on the majority of nonmetastatic, non-small-cell lung cancer (NSCLC) patients in our institution. We used the results of mediastinoscopy from a Stage III NSCLC cohort to assess the reliability of positron emission tomography (PET) scans at identifying involved mediastinal lymph nodes (MLN) when used during radiotherapy planning. Methods and Materials: Mediastinoscopy was the gold standard. Characteristics of PET were calculated for nodal sensitivity. To compare the impact on contouring, theoretical nodal targets (NTs) containing involved MLNs were generated using PET and mediastinoscopy. We determined whether the NT derived from PET (NT-P) was equivalent to, greater than, or less than that seen with the mediastinoscopy (NT-M). Results: Data for 122 patients with Stage III NSCLC, treated between 2000 and 2004, were analyzed. After exclusions, 87 patients with Stage III disease by mediastinoscopy were analyzed. Overall PET sensitivity was 61% and positive predictive value was 94%. Of the 87 patients, 33 (38%) had no abnormal MLN findings by PET. Of 36 Stage IIIA cancer patients, 18 (50%) had NT-P equivalent to NT-M, 10 (28%) had smaller NT-Ps, and 8 (22%) had larger NT-Ps compared with NT-Ms. Of 18 Stage IIIB cancer patients, NTs were equivalent in 6 (34%); in 1 patient (5%) NT-P was larger than the corresponding NT-M, and in 11 (61%) smaller than the corresponding NT-M. Conclusions: In this study PET had modest sensitivity to detect MLN involvement and underestimated the extent of involved nodes for target definition. The role of PET in mediastinal contouring needs to be evaluated prospectively and ideally correlated with a pathology standard.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Between In-Beam and Offline Positron Emission Tomography Imaging of Proton and Carbon Ion Therapeutic Irradiation at Synchrotron- and Cyclotron-Based Facilities

Purpose: The benefit of using dedicated in-beam positron emission tomography (PET) detectors in the treatment room instead of commercial tomographs nearby is an open question. This work quantitatively compares the measurable signal for in-beam and offline PET imaging, taking into account realistic acquisition strategies at different ion beam facilities. Both scenarios of pulsed and continuous irradiation from synchrotron and cyclotron accelerators are considered, because of their widespread use in most carbon ion and proton therapy centers. Methods and Materials: A mathematical framework is introduced to compare the time-dependent amount and spatial distribution of decays from irradiation-induced isotope production. The latter is calculated with Monte Carlo techniques for real proton treatments of head-and-neck and paraspinal tumors. Extrapolation to carbon ion irradiation is based on results of previous phantom experiments. Biologic clearance is modeled taking into account available data from previous animal and clinical studies. Results: Ratios between the amount of physical decays available for in-beam and offline detection range from 40% to 60% for cyclotron-based facilities, to 65% to 110% (carbon ions) and 94% to 166% (protons) at synchrotron-based facilities, and increase when including biologic clearance. Spatial distributions of decays during irradiation exhibit better correlation with the dose delivery and reduced influence of biologic processes. Conclusions: In-beam imaging can be advantageous for synchrotron-based facilities, provided that efficient PET systems enabling detection of isotope decays during beam extraction are implemented. For very short (<2 min) irradiation times at cyclotron-based facilities, a few minutes of acquisition time after the end of irradiation are needed for counting statistics, thus affecting patient throughput.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of {sup 11}C-Methionine-Positron Emission Tomography on Gross Tumor Volume Delineation in Stereotactic Radiotherapy of Skull Base Meningiomas

Purpose: To evaluate the effect of trimodal image fusion using computed tomography (CT), magnetic resonance imaging (MRI) and {sup 11}C-methionine positron emission tomography (MET-PET) for gross tumor volume delineation in fractionated stereotactic radiotherapy of skull base meningiomas. Patients and Methods: In 32 patients with skull base meningiomas, the gross tumor volume (GTV) was outlined on CT scans fused to contrast-enhanced MRI (GTV-MRI/CT). A second GTV, encompassing the MET-PET positive region only (GTV-PET), was generated. The additional information obtained by MET-PET concerning the GTV delineation was evaluated using the PET/CT/MRI co-registered images. The sizes of the overlapping regions of GTV-MRI/CT and GTV-PET were calculated and the amounts of additional volumes added by the complementing modality determined. Results: The addition of MET-PET was beneficial for GTV delineation in all but 3 patients. MET-PET detected small tumor portions with a mean volume of 1.6 {+-} 1.7 cm{sup 3} that were not identified by CT or MRI. The mean percentage of enlargement of the GTV using MET-PET as an additional imaging method was 9.4% {+-} 10.7%. Conclusions: Our data have demonstrated that integration of MET-PET in radiotherapy planning of skull base meningiomas can influence the GTV, possibly resulting in an increase, as well as in a decrease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Clinical Trial of Positron Emission Tomography/Computed Tomography Image-Guided Intensity-Modulated Radiation Therapy for Cervical Carcinoma With Positive Para-Aortic Lymph Nodes

Purpose: To describe a more aggressive treatment technique allowing dose escalation to positive para-aortic lymph nodes (PALN) in patients with cervical cancer, by means of positron emission tomography (PET)/computed tomography (CT)-guided intensity-modulated radiation therapy (IMRT). Here, we describe methods for simulation and planning of these treatments and provide objectives for target coverage as well as normal tissue sparing to guide treatment plan evaluation. Methods and Materials: Patients underwent simulation on a PET/CT scanner. Treatment plans were generated to deliver 60.0 Gy to the PET-positive PALN and 50.0 Gy to the PALN and pelvic lymph node beds. Treatment plans were optimized to deliver at least 95% of the prescribed doses to at least 95% of each target volume. Dose-volume histograms were calculated for normal structures. Results: The plans of 10 patients were reviewed. Target coverage goals were satisfied in all plans. Analysis of dose-volume histograms indicated that treatment plans involved irradiation of approximately 50% of the bowel volume to at least 25.0 Gy, with less than 10% receiving at least 50.0 Gy and less than 1% receiving at least 60.0. With regard to kidney sparing, approximately 50% of the kidney volume received at least 16.0 Gy, less than 5% received at least 50.0 Gy, and less than 1% received at least 60.0 Gy. Conclusions: We have provided treatment simulation and planning methods as well as guidelines for the evaluation of target coverage and normal tissue sparing that should facilitate the more aggressive treatment of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET{sub HCT}/HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET{sub ACT}/ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV{sub max}), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET{sub HCT}, and for all patients the artifact was removed or reduced in the corresponding PET{sub ACT}. The impact of respiration artifact was the worst for lesions less than 50 cm{sup 3} and located below the dome of the diaphragm. For lesions in this group, the mean SUV{sub max} difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}-F-Fluorodeoxyglucose-Positron Emission Tomography Evaluation of Early Metabolic Response During Radiation Therapy for Cervical Cancer

Purpose: To document changes in cervical tumor {sup 18}-F-fluorodeoxyglocose (FDG) uptake during radiation therapy and to correlate those changes with post-treatment tumor response and survival outcome. Methods and Materials: A total of 36 patients with Stage Ib1 to IIIb cervical cancer were enrolled in an institutional protocol examining the use of fluorodeoxyglucose-positron emission tomography (FDG-PET) for brachytherapy treatment planning. As part of this study, FDG-PET or PET/computed tomograpy (CT) images were obtained before, during, and after the completion of radiation therapy. Tumor metabolic responses were assessed qualitatively and semi-quantitatively by measurement of the maximal standardized uptake value (SUV{sub max}). Results: Post-treatment FDG-PET images were obtained for 36 patients in this study. Of the patients, 29 patients had a complete metabolic response on the post-treatment PET, 4 had a partial metabolic response, and 3 had new sites of FDG uptake. Six patients had a complete metabolic response observed during radiation therapy, 26 had a partial metabolic response and 4 had stable or increased tumor metabolic activity. For patients with complete metabolic response during radiation therapy, median time to complete response was 29.5 days (range, 18-43 days). The mean cervical tumor SUV{sub max} decreased from 11.2 (SD, 6.3; range, 2.1-38.0) pretreatment to 2.4 (SD, 2.7; range, 0-8.8) mid treatment, and 0.5 (SD, 1.7; range, 0-8.3) post-treatment. Conclusions: During radiation therapy for cervical cancer, FDG-PET can be used to monitor treatment response. Complete metabolic response during radiation therapy was observed for a subset of patients. Recommendations regarding the optimal timing of FDG-PET during treatment for cervical cancer will require further systematic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography to Estimate the Length of Gross Tumor in Patients With Squamous Cell Carcinoma of the Esophagus

Purpose: To determine the optimal method of using {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) to estimate gross tumor length in esophageal carcinoma. Methods and Materials: Thirty-six patients with esophageal squamous cell carcinoma treated with radical surgery were enrolled. Gross tumor volumes (GTVs) were delineated using three different methods: visual interpretation, standardized uptake value (SUV) 2.5, and 40% of maximum standard uptake value (SUV{sub max}) on FDG-PET imaging. The length of tumors on PET scan were measured and recorded as Length{sub vis}, Length{sub 2.5}, and Length{sub 40}, respectively, and compared with the length of gross tumor in the resected specimen (Length{sub gross}). All PET data were reviewed again postoperatively, and the GTV was delineated using various percentages of SUV{sub max}. The optimal-threshold SUV was generated when the length of PET matched the Length{sub gross}. Results: The mean ({+-}SD) Length{sub gross} was 5.48 {+-} 1.98 cm. The mean Length{sub vis}, Length{sub 2.5}, and Length{sub 40} were 5.18 {+-} 1.93 cm, 5.49 {+-} 1.79 cm, and 4.34 {+-} 1.54 cm, respectively. The mean Length{sub vis} (p = 0.123) and Length{sub 2.5} (p = 0.957) were not significantly different from Length{sub gross}, and Length{sub 2.5} seems more approximate to Length{sub gross.} The mean Length{sub 40} was significantly shorter than Length{sub gross} (p < 0.001). The mean optimal threshold was 23.81% {+-} 11.29% for all tumors, and it was 19.78% {+-} 8.59%, 30.92% {+-} 12.28% for tumors {>=}5 cm, and <5 cm, respectively (p = 0.009). The correlation coefficients of the optimal threshold were -0.802 and -0.561 with SUV{sub max} and Length{sub gross}, respectively. Conclusions: The optimal PET method to estimate the length of gross tumor varies with tumor length and SUV{sub max}; an SUV cutoff of 2.5 provided the closest estimation in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗