Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pollution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Reduction of gaseous pollutant emissions from gas turbine combustors using hydrogen-enriched jet fuel

Recent progress in an evaluation of the applicability of the hydrogen enrichment concept to achieve ultralow gaseous pollutant emission from gas turbine combustion systems is described. The target emission indexes for the program are 1.0 for oxides of nitrogen and carbon monoxide, and 0.5 for unburned hydrocarbons. The basic concept utilizes premixed molecular hydrogen, conventional jet fuel, and air to depress the lean flammability limit of the mixed fuel. This is shown to permit very lean combustion with its low NOx production while simulataneously providing an increased flame stability margin with which to maintain low CO and HC emission. Experimental emission characteristics and selected analytical results are presented for a cylindrical research combustor designed for operation with inlet-air state conditions typical for a 30:1 compression ratio, high bypass ratio, turbofan commercial engine.

Clayton, R. M.↗

Monitoring Air Pollution from Satellites (MAPS). Volume 1: Technical report

Performance tests on an electro-optical model of an infrared sensor for remote measurements of trace atmospheric gases are detailed; the instrument utilized a sample of the gas to be measured as spectral filter. Also reported is the development of radiometric calibration equipment that determines responses to simulated pollution effects. Results show excellent agreement with theoretical performance predictions with the exception of nonuniform radiance responses. Balance stability to an accuracy better than the rms noise level was demonstrated for the EOM in both the NH3 and CO modes for a period of two days under laboratory conditions. Flight test results show that the temperature range of the absorption cell is restricted to 255 K or higher.

Source record↗

Satellite, aircraft, and drogue studies of coastal currents and pollutants

The mounting interest in extracting oil and other resources from the continental shelf and continuing use of shelf and estuarine waters for waste disposal is creating a need for synoptic means of determining currents and monitoring pollutants in this area. A satellite-aircraft-drogue approach is described which employs remotely tracked expendable drogues together with satellite and aircraft observations of waste plumes and current tracers such as dyes or suspended sediment. Tests conducted on the continental shelf and in Delaware Bay indicate that the approach provides a cost-effective means of studying current circulation, oil-slick movement, and ocean waste dispersion under a wide range of environmental conditions.

Klemas, V.↗

Remote measurement of pollution from aircraft

This paper discusses the problem of the remote measurement of tropospheric air pollution from aircraft platforms. Following a discussion of the energy sources available for passive remote sensing and the location of the absorption bands of the gases, it describes the spectral resolution that would be required and the relative merits of the shorter and longer infrared wavelengths. It then traces the evolution of one instrument concept (the gas filter correlation radiometer) to its present state, and describes flight results that show the technique to be capable of measuring carbon monoxide over water. A new instrument is described that will allow the measurements to be extended to areas over land.

Reichle, H. G., Jr.↗

An experimental/analytical program to assess the utility of lidar for pollution monitoring

The development and demonstration of lidar techniques for the remote measurement of atmospheric constituents and transport processes in the lower troposphere was carried out. Particular emphasis was given to techniques for monitoring SO2 and particulates, the principal pollutants in power plant and industrial plumes. Data from a plume dispersion study conducted in Maryland during September and October 1976 were reduced, and a data base was assembled which is available to the scientific community for plume model verification. A UV Differential Absorption Lidar (DIAL) was built, and preliminary testing was done.

Mills, F. S.↗

Pollutant dispersal in a nonuniform flow

Closed-form solutions are presented for the diffusion of an inert pollutant in a nonuniform flow; matrix analysis is employed to facilitate the solutions. In particular, cases involving an instantaneous point release, a constant point source, and an instantaneous line release are treated. Computations with and without the effects of velocity nonuniformities are given for the dispersal of the ground cloud resulting from the launch of a large rocket (the cloud considered as an instantaneous point source) and the dispersal of an aircraft exhaust (the exhaust considered as an instantaneous line release). In both cases the velocity nonuniformities have important effects on the computations.

Smith, G. L.↗

A two-dimensional model for the transport of pollutants in an urban basin

The distribution of carbon monoxide emitted mainly from an automobile exhaust is investigated. Carbon monoxide is assumed to be chemically inert. The transport model, in analogy with the shallow-water theory in fluid dynamics, considers variation of all physical quantities in the horizontal direction below the temperature inversion layer. Pollutants are found to be carried primarily by the wind; turbulent diffusion in a normal day plays only a minor role. The concentration of CO predicted by the present model for the entire Los Angeles basin is compared with observed data at nine stations. Accuracy of four different numerical schemes, the effect of turbulent diffusivity, and the source strengths are examined.

Liu, C. Y.↗

Landsat and water pollution

Report presents data derived from satellite images predicting pollution loads after rainfall. It explains method for converting Landsat images of Eastern United States into cover maps for Baltimore/five county region.

Castruccio, P.↗

Remote measurement of atmospheric pollutants

The concentration and vertical distribution of atmospheric ammonia and ozone are remotely sensed, using dual-C02-laser multichannel infrared Heterodyne Spectrometer (1HS). Innovation makes atmospheric pollution measurements possible with nearly-quantum-noise-limited sensitivity and ultrafine spectral resolution.

Allario, F.↗

Effect of primary-zone equivalence ratio on pollutant formation

Test were conducted to determine the effect of primary-zone equivalence ratio on the formation of smoke and other gaseous pollutants in an experimental can combustor. Several fuel injection techniques were examined at primary-zone equivalence ratios from 0.8 to 2.0. The main emphasis was on reducing fuel-rich-combustion smoke levels. Two of the four fuel injection configurations studied produced smoke levels below a smoke number of 20 at a primary-zone equivalence ratio of about 1.7. As the fuel mixing and atomization were recorded at primary-zone equivalence ratios as high as 2.0. The gaseous emissions of unburned hydrocarbons, carbon monoxide, and oxides of nitrogen were quite sensitive to the fuel injection configuration as well as to the primary-zone equilvalence ratio.

Claus, R. W.↗

Air pollution from aircraft

Forty-one annotated abstracts of reports generated at MIT and the University of Sheffield are presented along with summaries of the technical projects undertaken. Work completed includes: (1) an analysis of the soot formation and oxidation rates in gas turbine combustors, (2) modelling the nitric oxide formation process in gas turbine combustors, (3) a study of the mechanisms causing high carbon monoxide emissions from gas turbines at low power, (4) an analysis of the dispersion of pollutants from aircraft both around large airports and from the wakes of subsonic and supersonic aircraft, (5) a study of the combustion and flow characteristics of the swirl can modular combustor and the development and verification of NO sub x and CO emissions models, (6) an analysis of the influence of fuel atomizer characteristics on the fuel-air mixing process in liquid fuel spray flames, and (7) the development of models which predict the stability limits of fully and partially premixed fuel-air mixtures.

Heywood, J. B.↗

Development of tunable high pressure CO2 laser for lidar measurements of pollutants and wind velocities, January 1976 to December 1977

A tunable multiatmospheric pulsed CO2 laser with emphasis on experimental features and supporting theoretical analyses important to differential absorption lidar and Doppler lidar measurement of pollutants and wind velocities is reported. The energy deposition and the means to produce the uniform high density plasma in the multiatmospheric medium, through UV preionization of an organic seed gas is discussed. Design features of the pulsed CO2 laser are presented. The radiative processes which are operative and prevent the laser from breaking into oscillations in a large number of modes over its broad amplification bandwidth are described. The mode competition for the transient pulsed laser oscillation in a standing wave and traveling wave ring laser configuration is discussed and contrasted with the approach to steady state oscillations. The latter findings are important to transient injection locking for production of a highly stable pulsed CO2 laser output.

Javan, A.↗

Lidar remote sensing of tropospheric pollutants and trace gases - Programs of NASA Langley Research Center

NASA Langley Research Center is engaged in a number of in-house and contracted programs to develop, evaluate, and apply lidar techniques to remote measurements of pollutant gases, trace molecules, and aerosols. The differential absorption lidar (DIAL) research programs include the development and evaluation of a UV DIAL system for remote measurements of SO2 and O3 concentrations and aerosol dispersion in urban and power-plant stack plumes, a near-IR DIAL system for vertical measurements of water vapor concentrations, and a high-power tunable IR DIAL system which will measure the concentration of gas species that have absorption features in the 1.4- to 4.4-micron wavelength range. The lidar programs which deal with aerosol measurements include the evaluation of a mobile ruby lidar system for use in plume dispersion model verification and the development of a high-spectral-resolution lidar system for measurement of aerosol extinction and backscattering coefficients. System characteristics and measurement sensitivities are discussed, and comparisons are made between simulations and experimental results.

Browell, E. V.↗

Signature extraction of ocean pollutants by eigenvector transformation of remote spectra

Spectral signatures of suspended matter in the ocean are being extracted through characteristic vector analysis of remote ocean color data collected with MOCS (Multichannel Ocean Color Sensor). Spectral signatures appear to be obtainable through analyses of 'linear' clusters that appear on scatter diagrams associated with eigenvectors. Signatures associated with acid waste, sewage sludge, oil, and algae are presented. The application of vector analysis to two acid waste dumps overflown two years apart is examined in some detail. The relationships between eigenvectors and spectral signatures for these examples are analyzed. These cases demonstrate the value of characteristic vector analysis in remotely identifying pollutants in the ocean and in determining the consistency of their spectral signatures.

Grew, G. W.↗

Laser spectroscopic detection of air pollutants

A brief review is presented of the operating principles and applications of laser systems for monitoring pollution based on absorption spectroscopy. Particular consideration is given to an active bistatic system involving a cooperative reflector; an active monostatic system involving natural reflectors; an active monostatic system involving aerosol backscattering; and passive monostatic heterodyne detection.

Hinkley, E. D.↗

Satellite-aided evaluation of population exposure to air pollution

The evaluation of population exposure to air pollution through the computer processing of Landsat digital land use data, along with total suspended particulate estimates and population data by census tracts, is demonstrated. Digital image processing was employed to analyze simultaneously data from Landsat MSS bands 4 through 7 in order to extract land use and land cover information. The three data sets were spatially registered in a digital format, compatible with integrated computer processing, and cross-tabulated. A map illustrating relative air quality by 2-sq km cells for the residential population in the Portland, Oregon area is obtained.

Todd, W. J.↗

Fast-response atmospheric-pollutant monitor

Fast infrared spectrometer measures atmospheric C0, CH4, and HC1 over range of 1 to 12 ppm. With modifications it could measure other pollutants and use natural light as source. Cell filled with sample to be measured filters out spectral lines of interest. Infrared beam passes through rotating cell holder that produces chopped signals at two frequencies. Difference in signal amplitudes depends on amount of test gas in sample. Signal processing circuitry amplifies and separates test-gas and reference signals.

Sebacher, D. I.↗