Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Postlaunch calibration of spacecraft attitude instruments

The accuracy of both onboard and ground attitude determination can be significantly enhanced by calibrating spacecraft attitude instruments (sensors) after launch. Although attitude sensors are accurately calibrated before launch, the stresses of launch and the space environment inevitably cause changes in sensor parameters. During the mission, these parameters may continue to drift requiring repeated on-orbit calibrations. The goal of attitude sensor calibration is to reduce the systematic errors in the measurement models. There are two stages at which systematic errors may enter. The first occurs in the conversion of sensor output into an observation vector in the sensor frame. The second occurs in the transformation of the vector from the sensor frame to the spacecraft attitude reference frame. This paper presents postlaunch alignment and transfer function calibration of the attitude sensors for the Compton Gamma Ray Observatory (GRO), the Upper Atmosphere Research Satellite (UARS), and the Extreme Ultraviolet Explorer (EUVE).

Davis, W.↗

Training material models using gradient descent algorithms

High temperature design requires accurate constitutive models to describe material inelastic deformation and failure behavior. Oftentimes, calibrating accurate models devolves into the problem of fitting the model parameters against experimental test data. Here, we present the pyopmat package, an open source framework for calibrating constitutive models against experiment data subjected to various loading conditions using machine learning techniques. The package calculates the exact gradient of the model response with respect to the parameters using a combination of automatic differentiation and the adjoint method. Given this exact gradient, we compare the performance of several gradient-based optimization techniques in fitting realistic constitutive models against data. Here, we demonstrate the efficiency and accuracy of our package through example problems using both synthetic data, generated using known parameter sets, under monotonic and cyclic loading conditions and also with an example applying the techniques developed here to actual high temperature creep-fatigue test data.

36 MATERIALS SCIENCE↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Transient Storage Model Parameter Optimization Using the Simulated Annealing Method

Hyporheic exchange in streams is critical to ecosystem functions such as nutrient cycling along river corridors, especially for slowly moving or small stream systems. The transient storage model (TSM) has been widely used for modeling of hyporheic exchange. TSM calibration, for hyporheic exchange, is typically used to estimate four parameters, including the mass exchange rate coefficient, the dispersion coefficient, stream cross-sectional area, and hyporheic zone cross-sectional area. Prior studies have raised concerns regarding the non-uniqueness of the inverse problem for the TSM, that is, the occurrence of different parameter vectors resulting in TSM solution that reproduces the observed in-stream tracer break through curve (BTC) with the same error. This leads to practical non-identifiability in determining the unknown parameter vector values even when global-optimal values exist, and the parameter optimization becomes practically non-unique. To address this problem, we applied the simulated annealing method to calibrate the TSM to BTCs, because it is less susceptible to local minima-induced non-identifiability. A hypothetical (or synthetic) tracer test data set with known parameters was developed to demonstrate the capability of the simulated annealing method to find the global minimum parameter vector, and it identified the “hypothetically-true” global minimum parameter vector even with input data that were modified with up to 10% noise without increasing the number of iterations required for convergence. The simulated annealing TSM was then calibrated using two in-stream tracer tests conducted in East Fork Poplar Creek, Tennessee. In conclusion, simulated annealing was determined to be appropriate for quantifying the TSM parameter vector because of its search capability for the global minimum parameter vector.

54 ENVIRONMENTAL SCIENCES↗

Stereo viewing 3-component, planar PIV utilizing fuzzy inference

An all electronic 3-D Digital Particle Image Velocimetry (DPIV) system has been developed for use in high velocity (supersonic) flows. Two high resolution CCD cameras mounted in a stereo viewing configuration are used to determine the out-of-plane velocity component from the difference of the in-plane velocity measurements. Double exposure image frames are acquired and Fuzzy inference techniques are used to maximize the validity of the velocity estimates obtained from the auto-correlation analysis. The CCD cameras are tilted relative to their respective lens axes to satisfy Scheimpflug's condition. Tilting the camera film plane ensures that the entire image plane is in focus. Perspective distortion still results, but can be corrected by proper calibration of the optical system. A calibration fixture is used to determine the experimental setup parameters and to assess the accuracy to which the z-plane displacements can be estimated. The details of the calibration fixture and procedure are discussed in the text. A pair of pulsed Nd:YAG lasers operating at 532 nm are used to illuminate the seeded flow from a convergent nozzle operated in an underexpanded condition. The light sheet was oriented perpendicular to the nozzle flow, yielding planar cross-sections of the 3-component velocity field at several axial stations. The key features of the supersonic jet are readily observed in the cross-plane vector plots.

Wernet, Mark P.↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GEODYN system description, volume 1

A computer program for the estimation of orbit and geodetic parameters is presented. The areas in which the program is operational are defined. The specific uses of the program are given as: (1) determination of definitive orbits, (2) tracking instrument calibration, (3) satellite operational predictions, and (4) geodetic parameter estimation. The relationship between the various elements in the solution of the orbit and geodetic parameter estimation problem is analyzed. The solution of the problems corresponds to the orbit generation mode in the first case and to the data reduction mode in the second case.

Chin, M. M.↗

Automatic and rapid calibration of urban building energy models by learning from energy performance database

Urban building energy modeling (UBEM) is attracting increasing attention in the energy modeling filed. Unlike modeling a single building using detailed building systems information, UBEM generally uses limited high-level building stock data to infer default assumptions about building characteristics and operations. Additionally, this practice inherently brings uncertainty to UBEM. This study introduced a novel method of automatic and rapid calibration of UBEM based on the annual electricity and natural gas energy use data by learning the correlations between crucial model input parameters and the building energy use from the reference building models. A case study was presented to calibrate 72 large office buildings built before 1978 in San Francisco. Seventeen model parameters were selected and Monte Carlo sampling was used to create 1000 samples that reasonably represent the parameter space. Then 1000 simulations were performed for the reference building model to create an energy performance database. The results showed that by learning from the energy performance database, it took less than four simulation runs on average to calibrate a building model. After the calibration, the distributions of each parameter were obtained to replace their single predefined default values. For example, the default lighting power density of 21.39 W/m 2 was calibrated to be 7.50 W/m 2 on average. The case study successfully demonstrated the effectiveness of the novel calibration method for UBEM in the mild climate. The method will be further tested in future for other climate zones and other building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quality assurance procedures for environmental control and monitoring in plant growth facilities. Report of the North Central Regional 101 Committee on Growth Chamber Use

This report includes procedures for ensuring the quality of the environment provided for plant growth in controlled environment facilities. Biologists and engineers may use these procedures for ensuring quality control during experiments or for ensuring quality control in the design of plant growth facilities. Environmental monitoring prior to and during experiments is included in these procedures. Specific recommendations cover control, acquisition, and calibration for sensor types for the separate parameters of radiation (light), temperature, humidity, carbon dioxide, and air movement.

NASA Discipline Number 61-10↗

Quasi-Static and Dynamic Analysis of Composite Panels: Challenges in Engineering-Level Commercial Software

In engineering applications, where analysis time and efficiency are essential, analytical models and commercially available finite element (FE) material models are the two mainstream methods used to analyze composite crush scenarios. A reliable numerical model addressing the crushing response of composite materials requires a nonlinear progressive damage analysis which includes appropriate failure mechanisms such as matrix cracking, fragmentation, delamination, and fiber breakage. One might be able to address all these interacting failure responses through implementation/validation of a user defined material model or by utilization of a commercially available model, the latter being the most efficient engineering approach. In this paper, the quasi-static and dynamic crushing response of composite specimens, consisting of a C-channel and a corrugated geometry manufactured with carbon fiber/epoxy matrix fabric, are modeled using the progressive composite damage model within ABAQUS. The novel part of this work, which has not been previously addressed in the literature, is the utilization of a detailed parametric study to optimize composite damage model parameters for a given quasi-static crush simulation in ABAQUS. C-channel experiments were used to calibrate the model and then refine/optimize a set of material parameters that best fit the experimental results. These identical parameters were then used to simulate the crush response of the corrugated channel specimens, thereby making it a pure prediction and not a double recalibration. Next, the dynamic response of both panels were predicted, further confirming the predictive capability of the developed numerical model. The effect of parameter variation on the crush response is fully documented for future use in engineering applications utilizing this specific ABAQUS damage model.

Paria Naghipour↗

Flight Metal Plasma Thruster (MPT) Development, Qualification, and Thrust Measurement Campaign

A torsional thrust stand, calibrated for impulse bits in the range of 0.1mNs -0.5 mNs, was used to measure impulse bits during two campaigns at the NASA/GRC VF-3 Vacuum test Facility. Metal Plasma Thrusters (MPTs) with targets of Molybdenum, Copper and Stainless Steel (as used in upper stages of launch vehicles that are abandoned in LEO) were tested. This paper describes data from Mo targets (called pucks). The Cu and ss data will be presented elsewhere. Model predictions (based on a simple circuit model and published plasma parameters) were validated by data from the calibrated torsional thrust stand. The Metal Plasma Thruster uses solid metal propellant, hence requires no liquids, gases, flow valves or flow controls and has no moving parts. Total impulse ~5000Ns/U provides orbit raising and drag compensation capability.

Electric Propulsion↗

Flight MPT Development, Qualification and Thrust Measurement Campaign

A torsional thrust stand, calibrated for impulse bits in the range of 0.1mNs -0.5 mNs, was used to measure impulse bits during two campaigns at the NASA/GRC VF-3 Vacuum test Facility. Metal Plasma Thrusters (MPTs) with targets of Molybdenum, Copper and Stainless Steel (as used in upper stages of launch vehicles that are abandoned in LEO) were tested. This paper describes data from Mo targets (called pucks). The Cu and ss data will be presented elsewhere. Model predictions (based on a simple circuit model and published plasma parameters) were validated by data from the calibrated torsional thrust stand. The Metal Plasma Thruster uses solid metal propellant, hence requires no liquids, gases, flow valves or flow controls and has no moving parts. Total impulse ~5000Ns/U provides orbit raising and drag compensation capability.

Electric Propulsion↗

On the flow-stress model of Preston, Tonks, and Wallace - Observations, parameter constraints, and implementations (Rev. 1)

A detailed discussion about the PTW flow-stress model has been presented, including theoretical considerations, model calibrations to experimental data, and model implementations in LANL ASC hydro-codes. The main findings are: In order to reproduce the intended behavior of the PTW model at high strain rates, the following conditions on the model parameters need to be valid: y 1 ≥ s 0 and y 2 ≥ β ; When the conditions above are not satisfied, PTW and PTW_Mod1 have slightly different behavior in the phonon-drag regime, and should be treated as different models. PTW exhibits a discontinuity above the critical strain rate. PTW_Mod1 does not show such a discontinuity but implies a different strain-rate dependence at high strain rates. Examples of this behavior include older calibrations for stainless steel and depleted uranium; In the thermal-activation regime, some flexibility was introduced in the original PTW model to allow for different rate-dependent behaviors at intermediate strain rates. Example: copper. However, many material calibrations do not require this extra flexibility, and the complexity and ambiguity of the intended behavior can be partially blamed for the inconsistent model implementations across ASC codes; The limit for the material constant p going to zero is well defined and leads to a simplified flow-stress equation, discontinuity free; Modern calibrations of the PTW parameters are done using Impala. Constraints on the PTW parameters are enforced; Implementation of the PTW model in LANL ASC hydro-codes suffered of several shortcom ings. At the time of writing, FLAG and xRAGE contain consistent and correct implemen tations of the PTW and PTW_Mod1 models. Corresponding changes to Pagosa have been suggested.

36 MATERIALS SCIENCE↗

Advancing earth system model calibration: a diffusion-based method

Understanding of climate impact on ecosystems globally requires site-specific model calibration. Here we introduce a novel diffusion-based uncertainty quantification (DBUQ) method for efficient model calibration. DBUQ is a score-based diffusion model that leverages Monte Carlo simulation to estimate the score function and evaluates a simple neural network to quickly generate samples for approximating parameter posterior distributions. DBUQ is stable, efficient, and can effectively calibrate the model given diverse observations, thereby enabling rapid and site-specific model calibration on a global scale. This capability significantly advances Earth system modeling and our understanding of climate impacts on Earth systems. We demonstrate DBUQ's capability in E3SM land model calibration at the Missouri Ozark AmeriFlux forest site. Both synthetic and real-data applications indicate that DBUQ produces accurate parameter posterior distributions similar to those generated by Markov Chain Monte Carlo sampling but with 30X less computing time. This efficiency marks a significant stride in model calibration, paving the way for more effective and timely climate impact analyses.

Liu, Yanfang↗

Atmospheric drag model calibrations for spacecraft lifetime prediction

Although solar activity prediction uncertainty normally dominates decay prediction error budget for near-Earth spacecraft, the effect of drag force modeling errors for given levels of solar activity needs to be considered. Two atmospheric density models, the modified Harris-Priester model and the Jacchia-Roberts model, to reproduce the decay histories of the Solar Mesosphere Explorer (SME) and Solar Maximum Mission (SMM) spacecraft in the 490- to 540-kilometer altitude range were analyzed. Historical solar activity data were used in the input to the density computations. For each spacecraft and atmospheric model, a drag scaling adjustment factor was determined for a high-solar-activity year, such that the observed annual decay in the mean semimajor axis was reproduced by an averaged variation-of-parameters (VOP) orbit propagation. The SME (SMM) calibration was performed using calendar year 1983 (1982). The resulting calibration factors differ by 20 to 40 percent from the predictions of the prelaunch ballistic coefficients. The orbit propagations for each spacecraft were extended to the middle of 1988 using the calibrated drag models. For the Jaccia-Roberts density model, the observed decay in the mean semimajor axis of SME (SMM) over the 4.5-year (5.5-year) predictive period was reproduced to within 1.5 (4.4) percent. The corresponding figure for the Harris-Priester model was 8.6 (20.6) percent. Detailed results and conclusions regarding the importance of accurate drag force modeling for lifetime predictions are presented.

Binebrink, A. L.↗

Post-Launch Calibration and Testing of Space Weather Instruments on GOES-R Satellite

The Geostationary Operational Environmental Satellite - R (GOES-R) is the first of a series of satellites to be launched, with the first launch scheduled for October 2016. The three instruments - Solar Ultra Violet Imager (SUVI), Extreme ultraviolet and X-ray Irradiance Sensor (EXIS), and Space Environment In-Situ Suite (SEISS) provide the data needed as inputs for the product updates National Oceanic and Atmospheric Administration (NOAA) provides to the public. SUVI is a full-disk extreme ultraviolet imager enabling Active Region characterization, filament eruption, and flare detection. EXIS provides inputs to solar backgrounds/events impacting climate models. SEISS provides particle measurements over a wide energy-and-flux range that varies by several orders of magnitude and these data enable updates to spacecraft charge models for electrostatic discharge. EXIS and SEISS have been tested and calibrated end-to-end in ground test facilities around the United States. Due to the complexity of the SUVI design, data from component tests were used in a model to predict on-orbit performance. The ground tests and model updates provided inputs for designing the on-orbit calibration tests. A series of such tests have been planned for the Post-Launch Testing (PLT) of each of these instruments, and specific parameters have been identified that will be updated in the Ground Processing Algorithms, on-orbit parameter tables, or both. Some of SUVI and EXIS calibrations require slewing them off the Sun, while no such maneuvers are needed for SEISS. After a six-month PLT period the GOES-R is expected to be operational. The calibration details are presented in this paper.

On-orbit Calibration↗

Post-Launch Calibration and Testing of Space Weather Instruments on GOES-R Satellite

The Geostationary Operational Environmental Satellite - R (GOES-R) is the first of a series of satellites to be launched, with the first launch scheduled for October 2016. The three instruments Solar UltraViolet Imager (SUVI), Extreme ultraviolet and X-ray Irradiance Sensor (EXIS), and Space Environment In-Situ Suite (SEISS) provide the data needed as inputs for the product updates National Oceanic and Atmospheric Administration (NOAA) provides to the public. SUVI is a full-disk extreme ultraviolet imager enabling Active Region characterization, filament eruption, and flare detection. EXIS provides inputs to solar back-ground-sevents impacting climate models. SEISS provides particle measurements over a wide energy-and-flux range that varies by several orders of magnitude and these data enable updates to spacecraft charge models for electrostatic discharge. EXIS and SEISS have been tested and calibrated end-to-end in ground test facilities around the United States. Due to the complexity of the SUVI design, data from component tests were used in a model to predict on-orbit performance. The ground tests and model updates provided inputs for designing the on-orbit calibration tests. A series of such tests have been planned for the Post-Launch Testing (PLT) of each of these instruments, and specific parameters have been identified that will be updated in the Ground Processing Algorithms, on-orbit parameter tables, or both. Some of SUVI and EXIS calibrations require slewing them off the Sun, while no such maneuvers are needed for SEISS. After a six-month PLT period the GOES-R is expected to be operational. The calibration details are presented in this paper.

On-orbit Calibration↗