Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Superlinear threshold detectors in quantum cryptography

We introduce the concept of a superlinear threshold detector, a detector that has a higher probability to detect multiple photons if it receives them simultaneously rather than at separate times. Highly superlinear threshold detectors in quantum key distribution systems allow eavesdropping the full secret key without being revealed. Here, we generalize the detector control attack, and analyze how it performs against quantum key distribution systems with moderately superlinear detectors. We quantify the superlinearity in superconducting single-photon detectors based on earlier published data, and gated avalanche photodiode detectors based on our own measurements. The analysis shows that quantum key distribution systems using detector(s) of either type can be vulnerable to eavesdropping. The avalanche photodiode detector becomes superlinear toward the end of the gate. For systems expecting substantial loss, or for systems not monitoring loss, this would allow eavesdropping using trigger pulses containing less than 120 photons per pulse. Such an attack would be virtually impossible to catch with an optical power meter at the receiver entrance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly Reliable, High-Speed, Unidirectional Serial Data Links

Highly reliable, high-speed, unidirectional serial data-communication subsystems have been proposed to be installed in an upgrade of the computing systems aboard the space shuttles. The basic design concept of these serial data links is also adaptable to terrestrial use in applications in which there are requirements for highly reliable serial data communications. The hardware and software aspects of the architecture of the data links are dictated largely by a requirement, in the original space-shuttle application, for one computer to monitor the memory transactions and memory contents of other computers in real time with high reliability and without reliance on requests for retransmission. To minimize weight while affording a capability to transfer data at a required rate of 2.56 x 10(exp 8) bits per second, it was decided that the links would be serial ones of the fiber-channel type. [Fiber channel denotes a type of serial computer bus that is used to connect a computer (usually a supercomputer) with a high-speed data storage device. Depending on the specific application, the physical connection between the transmitter and receiver could be made via an optical fiber or a twisted pair of wires.] Heretofore, fiber-channel links have ordinarily been bidirectional and have operated under protocols that provide for receiving stations to detect errors and request retransmission when necessary. In the present case, the time taken by processing to request retransmission would conflict with the requirement for real-time transfer of data. To ensure reliability without retransmission, a link according to the proposal would utilize a modified version of the normal fiberchannel character set in conjunction with forward error correction by means of a Reed-Solomon code (see figure). The Reed-Solomon encoding and decoding and the translations between the normal and modified character sets would be effected by logic circuitry external to the fiber-channel transmitter and receiver, which would be commercial off-the-shelf units. The receiving end of the link could detect and correct errors at a rate as high as 4 million times per second, if necessary. The receiver detects uncorrectable double-byte errors. It has been estimated that uncorrectable-error rate would amount to one failure in about 10(exp 19) characters.

Cole, Robert M.↗

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

Optical technology program

Optical and infrared technology developments for guidance, tracking, and communication in aerospace missions

SUPERHETERODYNE RECEIVER↗

Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection

A fiber-optic sensor system is designed to measure magnetic fields associated with a lightning stroke. Field vector magnitudes are detected and processed for multiple locations. Since physical limitations prevent the sensor elements from being located in close proximity to highly conductive materials such as aluminum, the copper wire sensor elements (3) are located inside a 4-cubic-in. (.66-cubic-cm) plastic housing sensor head and connected to a fiber-optic conversion module by shielded cabling, which is limited to the shortest length feasible. The signal path between the conversion module and the avionics unit which processes the signals are fiber optic, providing enhanced immunity from electromagnetic radiation incident in the vicinity of the measurements. The sensors are passive, lightweight, and much smaller than commercial B-dot sensors in the configuration which measures a three-dimensional magnetic field. The system is expandable, and provides a standard-format output signal for downstream processing. Inside of the sensor head, three small search coils, each having a few turns on a circular form, are mounted orthogonally inside the non-metallic housing. The fiber-optic conversion module comprises three interferometers, one for each search coil. Each interferometer has a high bandwidth optical phase modulator that impresses the signal received from its search coil onto its output. The output of each interferometer travels by fiber optic cable to the avionics unit, and the search coil signal is recovered by an optical phase demodulator. The output of each demodulator is fed to an analog-to-digital converter, whose sampling rate is determined by the maximum expected rate of rise and peak signal magnitude. The output of the digital processor is a faithful reproduction of the coil response to the incident magnetic field. This information is provided in a standard output format on a 50-ohm port that can be connected to any number of data collection and processing instruments and/or systems. The measurement of magnetic fields using fiber-optic signal processing is novel because it eliminates limitations of a traditional B-dot system. These limitations include the distance from the sensor to the measurement device, the potential for the signal to degrade or be corrupted by EMI from lightning, and the size and weight of the sensor and associated plate.

Gurecki, Jay↗

Synchronization for Optical PPM Signals

Method based on statistical properties of weak pulse-positionmodulated (PPM) signal enables synchronization of receiver clock with received-signal time base. Method applies to weak optical M-ary PPM signals, for which there is only one pulse of length Tp transmitted during one of timeslots of length T in each successive interval of M timeslots. Method requires small dead time, Td, at beginning and end of each timeslot, during which pulse amplitude is zero.

Vilnrotter, V. A.↗

OECD MCCI project enhancing instrumentation for reactor materials experiments, Rev. 0 September 3, 2002.

Reactor safety experiments for studying the reactions of a molten core (corium) with water and/or concrete involve materials at extremely high temperature. Such high temperature severely restricts the types of sensors that can be employed to measure characteristics of the corium itself. Yet there is great interest in improving instrumentation so that the state of the melt can be established with more precision. In particular, it would be beneficial to increase both the upper range limit and accuracy of temperature measurements. The poor durability of thermocouples at high temperature is also an important issue. For experiments involving a water-quenched melt, direct measurements of the growth rate of the crust separating the melt and water would be of great interest. This is a key element in determining the nature of heat transfer between the melt and coolant. Despite its importance, no one has been able to directly measure the crust thickness during such tests. This paper considers three specialized sensors that could be introduced to enhance melt characterization: (1) A commercially fabricated, single point infrared temperature measurement with the footprint of a thermowell. A lens assembly and fiber optic cable linked to a receiver and amplifier measures the temperature at the base of a tungsten thermowell. The upper range limit is 3000 C and accuracy is {+-}0.25% of the reading. (2) In-house development of an ultrasonic temperature sensor that would provide multipoint measurements at temperatures up to {approx}3000 C. The sensors are constructed from tungsten rods and have a high temperature durability that is superior to that of thermocouples. (3) In-house development of an ultrasonic probe to measure the growth rate of the corium crust. This ultrasonic sensor would include a tungsten waveguide that transmits ultrasonic pulses up through the corium melt towards the crust and detects reflections from the melt/crust interface. A measurement of the echo time delay would provide the location of the interface. These three sensors would provide a considerable upgrade of the instrumentation used in our reactor materials tests. The infracouple is a commercial product that could provide an immediate improvement in temperature measurements. The sensor could also serve to corroborate thermocouple data by providing a measurement based upon a different physical principle. The ultrasonic temperature sensor would involve a greater investment and longer time frame than the infracouple, but offers all the advantages of the infracouple along with miniaturization and the ability to measure at multiple locations. In addition, the UTS is the platform from which we would begin development of the crust detector. Of the three sensors, the crust detector requires the most effort and entails the greatest uncertainty. However, a real-time crust thickness measurement has never before been made and such data would be unique and of great benefit to reactor materials experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thickness measurement system for transparent plates using dual digital versatile disc (DVD) pickups

A low-cost high-precision thickness measurement system for transparent plates that uses dual digital versatile disc (DVD) pickups is proposed. The two DVD pickups are used as the transmitter and the receiver in the measurement system, respectively. One of the DVD pickups emits a laser to the other DVD pickup (receiver) and projects on the photodiode integrated circuit of the receiver. The transparent plate is placed in the optical path to change the focused point that will affect the focusing error signal (FES) of the receiver. Using the FES, a mathematical model for thickness measurement based on the geometric optical method is developed. The experimental results show that the accuracy is 1.5 {mu}m, and the uncertainty is estimated to be {+-}1.37 {mu}m for the measured thickness of 150{mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new method of relative radiometric calibration for hyperspectral imaging based on skylight monitor

A new method of relative radiometric calibration based on the skylight monitor is presented for airborne hyperspectral remote sensing to eliminate the negative effect on data resulting from the time-varying skylight during a long flight. In terms of large area operation of mapping or spectral imaging, a static radiation model hardly reveals actual cases as external environment keeps changing. Compared with common considerable factors, fluctuation of skylight is the primary one that may observably affect spectral imaging continuously leading to radiation changes upon flight lines. To get rid of the influence of skylight on spectral imagery and monitoring the variation during the flight, we assemble a set of skylight monitor fixed to the aircraft cabin for the sake of recording the semi-spherical skylight keeping synchronization with hyperspectral imaging system and the position and orientation system. The skylight monitor consists of a cosine corrector on the top receiving the skylight, a stable optical fiber and a visible and near-infrared linear array modular spectrometer. The corresponding matched data of skylight with each frame of images is used to correct related digital number after stripe non-uniformity correction, achieving mean relative standard deviation (coefficient of variation or CV) of under 6% for all 256 bands. The final result shows a satisfactory calibrated image of an appropriate evaluation criteria with contrast of the original image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temporal Evolution and Dose-Volume Histogram Predictors of Visual Acuity After Proton Beam Radiation Therapy of Uveal Melanoma

Purpose: To perform an in-depth temporal analysis of visual acuity (VA) outcomes after proton beam radiation therapy (PBRT) in a large, uniformly treated cohort of uveal melanoma (UM) patients, to determine trends in VA evolution depending on pretreatment and temporally defined posttreatment VA measurements; and to investigate the relevance of specific patient, tumor and dose-volume parameters to posttreatment vision loss. Methods and Materials: Uveal melanoma patients receiving PBRT were identified from a prospectively maintained database. Included patients (n=645) received 56 GyE in 4 fractions, had pretreatment best corrected VA (BCVA) in the affected eye of count fingers (CF) or better, with posttreatment VA assessment at specified post-PBRT time point(s). Patients were grouped according to the pretreatment BCVA into favorable (≥20/40) or unfavorable (20/50-20/400) and poor (CF) strata. Temporal analysis of BCVA changes was described, and univariate and forward stepwise multivariate logistic regression analyses were performed to identify predictors for VA loss. Results: Median VA follow-up was 53 months (range, 3-213 months). At 60-month follow up, among evaluable treated eyes with favorable pretreatment BCVA, 45% retained BCVA ≥20/40, whereas among evaluable treated eyes with initially unfavorable/poor BCVA, 21% had vision ≥20/100. Among those with a favorable initial BCVA, attaining BCVA of ≥20/40 at any posttreatment time point was associated with subsequent maintenance of excellent BCVA. Multivariate analysis identified volume of the macula receiving 28GyE (P<.0001) and optic nerve (P=.0004) as independent dose-volume histogram predictors of 48-month post-PBRT vision loss among initially favorable treated eyes. Conclusions: Approximately half of PBRT-treated UM eyes with excellent pretreatment BCVA assessed at 5 years after treatment will retain excellent long-term vision. 28GyE macula and optic nerve dose-volume histogram parameters allow for rational treatment planning optimization that may lead to improved visual outcomes. The detailed temporal analysis with intermediate as well as long-term functional prognosis, and the relationship of outcomes with clinical and treatment planning parameters, is critical for informed care of UM patients before and after PBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and data path integration test of the global Feature EXtractor for the ATLAS Level-1 calorimeter trigger system Phase-I upgrade

The global Feature Extractor (gFEX) is a component of the Phase-I upgrade of the Level-1 Calorimeter (L1Calo) trigger system for the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The gFEX is used to identify patterns of energy associated with the hadronic decays of high momentum Higgs, W and Z bosons, top quarks, and exotic particles in real time at the 40 MHz LHC bunch crossing rate. Three prototypes were implemented and tested from 2014 to 2017. With the lessons learned from the prototypes, the final gFEX production board has been implemented at the end of 2017. The gFEX receives up to 300 fiber optical links from the calorimeter and transmits trigger data on 96 links to the ATLAS Level-1 Topological [1] (L1Topo) trigger at a rate of up to 12.8 Gb/s. There are also 24 electrical links on board for communication between two FPGAs running at speeds of up to 25.6 Gb/s. Here, the hardware functionality and performance of the production board have been evaluated. A data path integration test between the Liquid Argon Digital Processing Blade (LDPB) [2] and the Front End LInk eXchange (FELIX) [3] was performed successfully at CERN in 2018.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modification of the collective Thomson scattering radiometer in the search for parametric decay on TEXTOR

Strong scattering of high-power millimeter waves at 140 GHz has been shown to take place in heating and current-drive experiments at TEXTOR when a tearing mode is present in the plasma. The scattering signal is at present supposed to be generated by the parametric decay instability. Here we describe the heterodyne detection system used to characterize the newly discovered signal measured at TEXTOR, and we present spectral shapes in which the signal can appear under different conditions. The radiation is collected by the receiver through a quasi-optical transmission line that is independent of the electron cyclotron resonance heating transmission line, and so the scattering geometry is variable. The signal is detected with 42 frequency channels ranging from 136 to 142 GHz. We demonstrate that the large signal does not originate from gyrotron spurious radiation. The measured signal agrees well with independent backscattering radiometer data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expectation-maximization algorithm for amplitude estimation of saturated optical transient signals

This paper addresses parameter estimation for an optical transient signal when the received data has been right-censored. We develop an expectation-maximization (EM) algorithm to estimate the amplitude of a Poisson intensity with a known shape in the presence of additive background counts, where the measurements are subject to saturation effects. We then compare the results of our algorithm with those of an EM algorithm that is unaware of the censoring.

47 OTHER INSTRUMENTATION↗

Analysis of laser heterodyne communications

Computer program, which predicts effects of optical aberrations on transmitters and receivers, includes effects of Gaussian pupil functions and utilizes algorithm that permits specification of number and location of output points for computed spread function results.

Cohen, S.↗

High resolution 10 mu spectrometry at different planetary latitudes. A practical Hadamard transform spectrometer for astronomical application

Infrared observations at different latitudes were studied in order to obtain spectra in the 10 micrometers region to understand differences in chemical composition or physical structure of the optical features. In order to receive such spectra of a rotating planet, simultaneous observations at different latitudes were made. A Hadamard transform spectrometer with 15 entrance slits was used to obtain 15 simultaneous spectra, at a resolution of 0.01 micrometers. The spectral band covered contained 255 spectral elements.

Tai, M. H.↗

An aircraft radiometer front end, addendum

A detailed description is given of a completely quasi-optical aircraft radiometer for use at frequencies of 150 GHz and above. The radiometer calibration and beam switching is described as well as a reflection isolator utilizing a reciprocating mirror and a quasi-optical local oscillator injection system. Receiver applications and performance levels are also given.

Gustincic, J. J.↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗