Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

aThe need for single-shot diagnostics of the periodic longitudinal density modulation of relativistic electrons at the resonant wavelength (microbunching) in a free-electron laser (FEL) or at broadband visible wavelengths as in a laser-driven plasma accelerator (LPA) has been reaffirmed. In the self-amplified spontaneous emission (SASE) FEL case, statistical fluctuations in the microbunching occur in the startup- from-noise process. In the LPA, the plasma itself is chaotic and varies shot to shot. Fortunately, we have shown that coherent optical transition radiation (COTR) techniques, can assess beam size, divergence, spectral evolution, and z-dependent gain (100,000) of microbunched electrons in a past SASE FEL experiment at 530 nm*. Recently, the application to LPAs has been demonstrated with single-shot near-field (NF) and far-field (FF) COTR imaging done at the exit of an LPA for the first time**. In this case few-micron beam sizes and extensive fringes due to su b-mrad divergences were measured based on point-spread-function effects and an analytical model for COTR interferometry (COTRI), respectively. A new COTR-based diagnostics application to pre-bunched electron beams formed by co-propagating a laser pulse and the electron pulse in a short undulator (modulator) is also described.

43 PARTICLE ACCELERATORS↗

SUPERNOVA 1986J VERY LONG BASELINE INTERFEROMETRY. II. THE EVOLUTION OF THE SHELL AND THE CENTRAL SOURCE

We present new Very Long Baseline Interferometry (VLBI) images of supernova (SN) 1986J, taken at 5, 8.4, and 22 GHz between t = 22 and 25 yr after the explosion. The shell expands {proportional_to}{proportional_to}t {sup 0.69+}-{sup 0.03}. We estimate the progenitor's mass-loss rate at (4-10) x 10{sup -5} M{sub sun} yr{sup -1} (for v{sub w} = 10 km s{sup -1}). Two bright spots are seen in the images. The first, in the northeast, is now fading. The second, very near the center of the projected shell and unique to SN 1986J, is still brightening relative to the shell, and now dominates the VLBI images. It is marginally resolved at 22 GHz (diameter {approx}0.3 mas; {approx}5 x 10{sup 16} cm at 10 Mpc). The integrated VLA spectrum of SN 1986J shows an inversion point and a high-frequency turnover, both progressing downward in frequency and due to the central bright spot. The optically thin spectral index of the central bright spot is indistinguishable from that of the shell. The small proper motion of 1500 +- 1500 km s{sup -1} of the central bright spot is consistent with our previous interpretation of it as being associated with the expected black-hole or neutron-star remnant. Now, an alternate scenario seems also plausible, where the central bright spot, like the northeast one, results when the shock front impacts on a condensation within the circumstellar medium (CSM). The condensation would have to be so dense as to be opaque at cm wavelengths ({approx}10{sup 3}x denser than the average corresponding CSM) and fortuitously close to the center of the projected shell. We include a movie of the evolution of SN 1986J at 5 GHz from t = 0 to 25 yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Melt dynamics of aluminum irradiated with ultrafast laser radiation at large intensities

Ablation of bulk aluminum has been investigated in situ using ultrafast laser radiation produced by chirped-pulse amplification technique (t{sub p}=80 fs, lambda=800 nm). Melt dynamics and the contribution of the amplified spontaneous emission (ASE) to the ablation have been studied experimentally and numerically for laser fluences well above ablation threshold (F < or approx. 10{sup 3}xF{sub thr}). Using transient quantitative phase microscopy (TQPm), dimensions and volume of ejected vapor, melt droplets, and liquid jets has been investigated. Computational analysis of the optical phase images has been used to determine the total volume of ejected material. A series of time-resolved phase images of vaporized material and/or melt, which are induced by n=1.8 pulses on an aluminum target, are obtained by means of TQPm up to temporal delay tau=1.65 mus after irradiation. Increase in material ejection rate is observed at delays tauapprox =300 ns and tauapprox =1.1 mus after the incident pulse. For large irradiation intensities a considerable contribution of ASE to ablation dynamics has been detected. Ex situ measurements of the ablated material by means of white-light interferometry and scanning electron microscopy provides corresponding factual removed volumes and highlight the pulse-to-pulse morphology changes.

36 MATERIALS SCIENCE↗

Sub-melt nanosecond pulsed-laser induced densification and strain-field relaxation in single-crystal diamond

Dislocations and polishing-induced defect networks in synthetic diamond introduce local strain fields and broaden Raman features, limiting performance in optical, thermal, and electronic applications. Laser annealing is emerging as a promising approach to repair surface and near-surface defects in diamond without entering the melt regime, yet surface densification, defect-state modification, and associated structural changes have not been well quantified. In this work, we show that sub-melt nanosecond pulsed-laser annealing (PLA) induces near-surface densification and defect-mediated strain relaxation in single-crystal Chemical Vapor Deposition (CVD) diamond. Single- and two-pulse PLA were applied, and structural evolution was quantified using co-registered ISO 25,178 white-light interferometry, depth-resolved Raman spectroscopy, and cross-sectional STEM with geometric phase analysis (GPA). Across a 5 × 6 grid (n = 30), responsive regions exhibit large reductions in local slope (Sdq 45–65%), developed area (Sdr 60–90%), height spread (Sp, Sz 30–65%), void volume (Vv 57–60%), and roughness amplitude (Sa, Sq 48–57%), consistent with densification of ∼4–6.5 nm. Raman profiling shows narrowing of the diamond line and improved spectral uniformity to depths of ∼2–3 μm. Given that the Raman probing depth significantly exceeds the densified layer thickness, this response is interpreted as consistent with long-range strain-field redistribution originating from the near-surface region. STEM-GPA strain maps further support this interpretation, showing smoother strain fields, suppressed hotspots, and redistribution of localized strain concentrations following PLA. These results are consistent with defect-mediated strain relaxation and densification-driven modification of the near-surface energy state. The approach provides a scalable pathway for improving near-surface structural quality in diamond relevant to electronic, photonic, and quantum applications.

Areal surface metrology (ISO 25,178)↗

Benchmarking of hydrodynamic plasma waveguides for multi-GeV laser-driven electron acceleration

Hydrodynamic plasma waveguides initiated by optical field ionization have recently become a key component of multi-GeV laser wakefield accelerators. Here, we present the most complete and accurate experimental and simulation-based characterization to date, applicable to current multi-GeV experiments and future 100 GeV-scale laser plasma accelerators. Crucial to the simulations is the correct modeling of intense Bessel beam interaction with meter-scale gas targets, the results of which are used as initial conditions for hydrodynamic simulations. The simulations are in good agreement with our experiments measuring evolving plasma and neutral hydrogen density profiles using two-color short pulse interferometry, enabling realistic determination of the guided mode structure for application to laser-driven plasma accelerator design. Published by the American Physical Society 2024

Physics↗

Extreme temperature robust optical sensor designs and fault-tolerant signal processing

Silicon Carbide (SiC) probe designs for extreme temperature and pressure sensing uses a single crystal SiC optical chip encased in a sintered SiC material probe. The SiC chip may be protected for high temperature only use or exposed for both temperature and pressure sensing. Hybrid signal processing techniques allow fault-tolerant extreme temperature sensing. Wavelength peak-to-peak (or null-to-null) collective spectrum spread measurement to detect wavelength peak/null shift measurement forms a coarse-fine temperature measurement using broadband spectrum monitoring. The SiC probe frontend acts as a stable emissivity Black-body radiator and monitoring the shift in radiation spectrum enables a pyrometer. This application combines all-SiC pyrometry with thick SiC etalon laser interferometry within a free-spectral range to form a coarse-fine temperature measurement sensor. RF notch filtering techniques improve the sensitivity of the temperature measurement where fine spectral shift or spectrum measurements are needed to deduce temperature.

47 OTHER INSTRUMENTATION↗

Piezoelectric and optical setup to measure an electrical field: Application to the longitudinal near-field generated by a tapered coax

We propose a new setup to measure an electrical field in one direction. This setup is made of a piezoelectric sintered lead zinconate titanate film and an optical interferometric probe. We used this setup to investigate how the shape of the extremity of a coaxial cable influences the longitudinal electrical near-field generated by it. For this application, we designed our setup to have a spatial resolution of 100 {mu}m in the direction of the electrical field. Simulations and experiments are presented.

36 MATERIALS SCIENCE↗

Laser-interferometric detectors for gravitational wave backgrounds at 100 MHz: Detector design and sensitivity

Recently, observational searches for gravitational wave background (GWB) have been developed and given direct and indirect constraints on the energy density of GWB in a broad range of frequencies. These constraints have already rejected some theoretical models of large GWB spectra. However, at 100 MHz, there is no strict upper limit from direct observation, though the indirect limit by {sup 2}He abundance due to big-bang nucleosynthesis exists. In this paper, we propose an experiment with laser interferometers searching GWB at 100 MHz. We considered three detector designs and evaluated the GW response functions of a single detector. As a result, we found that, at 100 MHz, the most sensitive detector is the design, a so-called synchronous recycling interferometer, which has better sensitivity than an ordinary Fabry-Perot Michelson interferometer by a factor of 3.3 at 100 MHz. When we select the arm length of 0.75 m and realistic optical parameters, the best sensitivity achievable is h{approx_equal}7.8x10{sup -21} Hz{sup -1/2} at 100 MHz with bandwidth {approx}2 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable Bose-Einstein-condensate Sagnac interferometer in a linear trap

We demonstrate a two-dimensional atom interferometer in a harmonic magnetic waveguide using a Bose-Einstein condensate. Such an interferometer could measure rotation using the Sagnac effect. Compared to free space interferometers, larger interactions times and enclosed areas can in principle be achieved, since the atoms are not in free fall. In this implementation, we induce the atoms to oscillate along one direction by displacing the trap center. We then split and recombine the atoms along an orthogonal direction using an off-resonant optical standing wave. We enclose a maximum effective area of 0.1 mm{sup 2} limited by fluctuations in the initial velocity and by the coherence time of the interferometer. We argue that this arrangement is scalable to enclose larger areas by increasing the coherence time and then making repeated loops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometric control of parametrically amplified waveforms

Using atomic coherence, four-wave-mixing radiation is generated between the excited states of a ladder-type configuration in rubidium atomic vapor. By using all-optical phase control between the two frequency-swept driving beams connecting the two lower levels, the generated signal is phase modulated across its bandwidth. When homodyned with a local oscillator, such phase control looks promising for applications including waveform shaping and high-resolution metrology. Experimental observations of signal line shape symmetrization, linewidth narrowing, and bandwidth switching are demonstrated.

74 ATOMIC AND MOLECULAR PHYSICS↗

IMAGING DISK DISTORTION OF BE BINARY SYSTEM {delta} SCORPII NEAR PERIASTRON

The highly eccentric Be binary system {delta} Sco reached periastron during early 2011 July, when the distance between the primary and secondary was a few times the size of the primary disk in the H band. This opened a window of opportunity to study how the gaseous disks around Be stars respond to gravitational disturbance. We first refine the binary parameters with the best orbital phase coverage data from the Navy Precision Optical Interferometer. Then we present the first imaging results of the disk after the periastron, based on seven nights of five telescope observations with the MIRC combiner at the CHARA array. We found that the disk was inclined 27.{sup 0}6 {+-} 6.{sup 0}0 from the plane of the sky, had a half-light radius of 0.49 mas (2.2 stellar radii), and consistently contributed 71.4% {+-} 2.7% of the total flux in the H band from night to night, suggesting no ongoing transfer of material into the disk during the periastron. The new estimation of the periastron passage is UT 2011 July 3 07:00 {+-} 4:30. Re-analysis of archival VLTI-AMBER interferometry data allowed us to determine the rotation direction of the primary disk, constraining it to be inclined either {approx}119 Degree-Sign or {approx}171 Degree-Sign relative to the orbital plane of the binary system. We also detect inner disk asymmetries that could be explained by spot-like emission with a few percent of the disk total flux moving in Keplerian orbits, although we lack sufficient angular resolution to be sure of this interpretation and cannot yet rule out spiral density waves or other more complicated geometries.

79 ASTRONOMY AND ASTROPHYSICS↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Enhancing strontium clock atom interferometry using quantum optimal control

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. In conclusion, this could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrating and Live-time Radiation Dosimetry by Optical Crystal Damage, Initial Results with Neutrons

Radiation damage can be assessed through many techniques, though the assessment is usually offline and shows only integrated dose. Transparent crystals can be optically monitored for radiation damage nondestructively, to serve as a detector for both immediate dose and integrated dose for signatures of radiation exposure history. There is also some difference in gamma-ray and neutron interactions which can be observed. Gamma ray interactions primarily produce electron displacements, which are preserved as color centers in ionic crystals and produce specific spectral absorption lines. Neutron interactions strongly produce lattice displacements that affect the index of refraction. The differences may allow us to use inexpensive crystals for long time neutron monitoring. Spectroscopic absorption lines can be quantified using prior technology, but due to prior limits in phase sensitivity there was no previous use of index of refraction measurements. Using novel techniques based on intracavity phase interferometry to assess lattice displacements, we are able to examine neutron irradiation in CaF2 crystals. Initial results with neutrons will be presented.

99 GENERAL AND MISCELLANEOUS↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technology and times scales in Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based measurement amenable to a wide range of experimental conditions. Interference between two optical signals—one Doppler shifted and the other not—is the essential principle in these measurements. A confluence of commercial technologies, largely driven by the telecommunication industry, makes PDV particularly convenient at near-infrared wavelengths. This discussion considers how measurement time scales of interest relate to the design, operation, and analysis of a PDV measurement, starting from the steady state through nanosecond resolution. Benefits and outstanding challenges of PDV are summarized, with comparisons to related diagnostics.

47 OTHER INSTRUMENTATION↗

Demonstration of a tunable two-frequency projected fringe pattern with acousto-optic deflectors

We report on a fringe projector for three-dimensional shape measurement. The developed instrument is able to project a two-frequency fringe pattern, each frequency is independently controlled by electronics. Moreover, each phase of the two fringe patterns is also independently adjusted. The projection system is based on the use of a pair of custom large bandwidth (40 MHz) and high efficiency (60%) TeO{sub 2} deflectors. The developed instrument offers the combined advantages of a static two-frequency fringe projector and of a tunable single frequency fringe projector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental position-time entanglement with degenerate single photons

We report an experiment in which two-photon interference occurs between degenerate single photons that never meet. The two photons travel in opposite directions through our fiber-optic interferometer and interference occurs when the photons reach two different, spatially separated, two-by-two couplers at the same time. We show that this experiment is analogous to the conventional Franson-type entanglement experiment where the photons are entangled in position and time. We measure wave-function overlaps for the two photons as high as 94{+-}3%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗