Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Illusion optics in chaotic light

The time-reversal process provides the possibility to counteract the time evolution of a physical system. Recent research has shown that such a process can occur in the first-order field correlation of chaotic light and result in the spatial interference and phase-reversal diffraction in an unbalanced interferometer. Here we report experimental investigations on the invisibility cloak and illusion phenomena in chaotic light. In an unbalanced interferometer illuminated by thermal light, we have observed the cloak effect and the optical transformation of one object into another object. The experimental results can be understood by the phase-reversal diffraction, and they demonstrate the theoretical proposal of similar effects in complementary media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗

mystic : software for autonomous discovery and design under uncertainty

Throughout the diverse range of science and engineering applications, there is a growing desire to develop computational methods that can reliably predict the behavior of complex systems. Specifically, there is a strategic need for tools that can robustly forecast the behavior of complex physical systems, where data may be high-dimensional, noisy, or sparse, and models of the system may be time-dependent or include uncertainty. We use mystic to build tools that leverage statistical learning, physics-informed learning, and active learning in the efficient generation of reliably predictive surrogates for complex physical systems. mystic is a robust, proven, open-source optimization and uncertainty quantification toolkit with over a decade of use in the design and optimization of neutron instrumentation, solar-powered drones, and gasguns, and in iterative tuning of models for Raman spectroscopy and elastoplastic materials strength. Recent developments have focused on automated learning of statistically robust surrogates under uncertainty, with applications in materials in extreme environments, nanostructures, materials simulations and strength models, and the failure of shielding under particle radiation. In 2020, McKerns demonstrated active learning of optimally robust surrogates with respect to new simulated data for molecular dynamics simulations of materials mixing in warm dense matter, and is currently applying active learning to the automated steering of particle accelerator beams and the optimal design and control of quantum optical sensor instrumentation.

42 ENGINEERING↗

A 10-Gb/s Driver/Receiver ASIC and Optical Modules for Particle Physics Experiments

We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE SOFT X-RAY AND NARROW-LINE EMISSION OF Mrk 573 ON KILOPARSEC SCALES

We present a study of the circumnuclear region of the nearby Seyfert galaxy Mrk 573 using Chandra, XMM-Newton, and Hubble Space Telescope (HST) data. We have studied the morphology of the soft (<2 keV) X-rays comparing it with the [O III] and H{alpha} HST images. The soft X-ray emission is resolved into a complex extended region. The X-ray morphology shows a biconical region extending up to 12 arcsec (4 kpc) in projection from the nucleus. A strong correlation between the X-rays and the highly ionized gas seen in the [O III]{lambda}5007 A image is reported. Moreover, we have studied the line intensities detected with the XMM-Newton Reflection Grating Spectrometer (RGS) and used them to fit the low-resolution EPIC/XMM-Newton and ACIS/Chandra spectra. The RGS/XMM-Newton spectrum is dominated by emission lines of C VI, O VII, O VIII, Fe XVII, and Ne IX, among other highly ionized species. A good fit is obtained using these emission lines found in the RGS/XMM-Newton spectrum as a template for Chandra spectra of the nucleus and extended emission, coincident with the cone-like structures seen in the [O III]/H{alpha} map. The photoionization model Cloudy provides a reasonable fit for both the nuclear region and the cone-like structures showing that the dominant excitation mechanism is photoionization. For the nucleus the emission is modeled using two phases: a high ionization [log (U) = 1.23] and a low ionization [log (U) = 0.13]. For the high-ionization phase the transmitted and reflected components are in a 1:2 ratio, whereas for the low ionization the reflected component dominates. For the extended emission, we successfully reproduced the emission with two phases. The first phase shows a higher ionization parameter for the northwest (log (U) = 0.9) than for the southeast cone (log (U) = 0.3). Moreover, this phase is transmission dominated for the southeast cone and reflection dominated for the northwest cone. The second phase shows a low-ionization parameter (log (U) = -3) and is rather uniform for northwest and southeast cones and equally distributed in reflection and transmission components. In addition, we have also derived the optical/infrared spectral energy distribution (SED) of the nucleus from high spatial resolution images of Mrk 573. The nuclear optical/infrared SED of the nucleus has been modeled by a clumpy torus model. The torus bolometric luminosity agrees very well with the active galactic nucleus (AGN) luminosity inferred from the observed hard X-ray spectrum. The optical depth along the line of sight expected from the torus modeling indicates a high neutral hydrogen column density in agreement with the classification of the nucleus of Mrk 573 as a Compton-thick AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface irregularities detected by flare inspection instrument

Portable fiber optics sensing device which detects surface irregularities in a specific tube flare, permits discrete dimensional measurements to be taken, scanned and read out with only one setup. Capabilities of the instrument can be expanded to include surface inspection of various kinds of tube flares.

Zoike, H. M.↗

Testing of fiber optic based sensors for advanced reactors in the Texas A&M University TRIGA reactor

An Optical Fiber Based Gamma Thermometer has been developed and tested at the Texas A&M University reactor as well as the Ohio State Research Reactor. This sensor technology provides temperature measurement of a thermal mass undergoing gamma heating, from which the gamma flux along the length of the sensor may be calculated. The gamma flux data from an array of OFBGTs could allow the determination of local power density within a nuclear reactor core in three dimensions. The design of the sensor makes use of optical fiber as a truly distributed temperature sensor with a spatial resolution less than 1mm and temperature accuracy of ±1°C. The testing program showed that the system provided the expected temperature data for each location. Overall, this sensor technology shows promise for current Light Water Reactors as well as advanced nuclear reactors by providing an unparalleled level of precision in reactor power measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hard X-ray nanoprobe beamline for nanoscale microscopy

The Hard X-ray Nanoprobe Beamline (or Nanoprobe Beamline) is an X-ray microscopy facility incorporating diffraction, fluorescence and full-field imaging capabilities designed and operated by the Center for Nanoscale Materials and the Advanced Photon Source at Sector 26 of the Advanced Photon Source at Argonne National Laboratory. This facility was constructed to probe the nanoscale structure of biological, environmental and material sciences samples. The beamline provides intense focused X-rays to the Hard X-ray Nanoprobe (or Nanoprobe) which incorporates Fresnel zone plate optics and a precision laser sensing and control system. The beamline operates over X-ray energies from 3 to 30 keV, enabling studies of most elements in the periodic table, with a particular emphasis on imaging transition metal

nanodiffraction↗

Optimization of quantum interferometric metrological sensors in the presence of photon loss

We optimize two-mode entangled number states of light in the presence of loss in order to maximize the extraction of the available phase information in an interferometer. Our approach optimizes over the entire available input Hilbert space with no constraints, other than fixed total initial photon number. We optimize to maximize the Fisher information, which is equivalent to minimizing the phase uncertainty. We find that in the limit of zero loss, the optimal state is the maximally path-entangled (so-called N00N) state, for small loss, the optimal state gradually deviates from the N00N state, and in the limit of large loss, the optimal state converges to a generalized two-mode coherent state, with a finite total number of photons. The results provide a general protocol for optimizing the performance of a quantum optical interferometer in the presence of photon loss, with applications to quantum imaging, metrology, sensing, and information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observing the next galactic supernova

No supernova (SN) in the Milky Way has been observed since the invention of the optical telescope, instruments for other wavelengths, neutrino detectors, or gravitational wave observatories. It would be a tragedy to miss the opportunity to fully characterize the next one. To aid preparations for its observations, we model the distance, extinction, and magnitude probability distributions of a successful Galactic core-collapse supernova (ccSN), its shock breakout radiation, and its massive star progenitor. We find, at very high probability (≅ 100%), that the next Galactic SN will easily be detectable in the near-IR and that near-IR photometry of the progenitor star very likely (≅ 92%) already exists in the Two Micron All Sky Survey. Most ccSNe (98%) will be easily observed in the optical, but a significant fraction (43%) will lack observations of the progenitor due to a combination of survey sensitivity and confusion. If neutrino detection experiments can quickly disseminate a likely position (∼3°), we show that a modestly priced IR camera system can probably detect the shock breakout radiation pulse even in daytime (64% for the cheapest design). Neutrino experiments should seriously consider adding such systems, both for their scientific return and as an added and internal layer of protection against false triggers. We find that shock breakouts from failed ccSNe of red supergiants may be more observable than those of successful SNe due to their lower radiation temperatures. We review the process by which neutrinos from a Galactic ccSN would be detected and announced. We provide new information on the EGADS system and its potential for providing instant neutrino alerts. We also discuss the distance, extinction, and magnitude probability distributions for the next Galactic Type Ia supernova (SN Ia). Based on our modeled observability, we find a Galactic ccSN rate of 3.2{sub −2.6}{sup +7.3} per century and a Galactic SN Ia rate of 1.4{sub −0.8}{sup +1.4} per century for a total Galactic SN rate of 4.6{sub −2.7}{sup +7.4} per century is needed to account for the SNe observed over the last millennium, which implies a Galactic star formation rate of 3.6{sub −3.0}{sup +8.3} M {sub ☉} yr{sup –1}.

79 ASTRONOMY AND ASTROPHYSICS↗

The Mars Reconnaissance Orbiter Mission Operations: Architecture and Approach

The Mars Reconnaissance Orbiter (MRO) was launched on August 12, 2005 by an Atlas V launch vehicle from Cape Canaveral Air Force Station. MRO will carry a rich set of science instruments to Mars and provide global, regional survey, and targeted observations. In addition, a set of engineering instruments providing optical navigation, Ka band telecommunication and UHF relay services to future Mars missions are part of the MRO payload. During the mission, the MRO operations teams are presented with two major challenges - unprecedented high data rate and data volumes, and complex science planning and resource sharing. MRO has the capability to communicate with earth at a maximum of six Megabits per second (> 50 times any previous Mars missions). With the current Deep Space Network (DSN) contact schedule of 19 eight-hour tracks per week, the baseline mission plan is for MRO to return 34 Terabits of raw science data during the two year primary science phase. Each of the science instruments has its unique requirements for global mapping, regional survey, and targeted observations. Some instruments prefer nadir-only observations, while others require off-nadir observations (especially for stereo viewing). The requirements from these Mars viewing instruments presented a significant challenge for the operations team to design the complex science planning and resource sharing/allocation process. This paper describes what MRO project is implementing to solve these challenges.

Mars Reconnaissance Orbiter (MRO)↗

Surface registration using a multi-beam optical probe and backscatter reflectometer

We introduce a technique for locating the position and orientation of an object surrounding a compound optical probe. The probe allows for simultaneous measurement of 150 points of laser velocimetry, and prior to a dynamic experiment it is important to know the initial position of the surface. Using an optical switch and a Luna OBR rangefinder, we measure the surface distance at hundreds of locations. These measurements are then combined with a dimensional inspection of the object and analysis routines to report the orientation and location of the inner surface relative to the probe. In addition, we present a technique to simultaneously measure the beam paths using a reference hemispherical surface and a number of distance measurements.

47 OTHER INSTRUMENTATION↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Experimental demonstration of nonlocal effects in the partial-collapse measurement and reversal process

We demonstrate experimentally the nonlocal reversal of a partial-collapse quantum measurement of a two-photon entangled state. Both the partial-collapse measurement and the reversal operation are implemented in linear optics with two displaced Sagnac interferometers, characterized by single-qubit quantum-process tomography. The recovered state is measured by quantum-state tomography, and its nonlocality is characterized by testing the Bell inequality. Our result will be helpful in quantum communication and quantum error correction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Star Wavefront Control with SCExAO Instrument: Demonstration with an Internal Source

Although only a small fraction of currently known exoplanets was found in binary and multiple systems, studies show that such stars do form planets, with an efficiency that is smaller, but within an order of magnitude of single stars. However, binaries are rarely considered as targets for exoplanet imaging space missions because of challenges of removing light from the second binary component. In our previous works it was shown how to solve two main issues that make exoplanet imaging in multiple systems impossible, namely, the mutual incoherence of speckles created by different binary components, and inability of a deformable mirror (DM) to control the starlight beyond the DM outer working angle/Nyquist limit. Feasibility of the developed Multi-Star Wavefront Control (MSWC) and Super-Nyquist Wavefront Control(SNWC) algorithms was demonstrated at the Ames Coronagraph Experiment (ACE) laboratory using a simple imaging system with a DM and no coronagraph. In this paper, we report the results our MSWC experiments using the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument that is part of our technology development effort. The main goal of these experiments is to validate MSWC on a real coronagraphic system by using an internal source to simulate at least one real representative binary target. In our demonstration narrow-band contrast of 4.1×10−6has been reached by using MSWC in a 12×6λ/D dark zone separated from the primary component of the simulated binary star (STF 3121 AB) by 4λ/D. This contrast is better by a factor of 13.2 than the contrast floor reached by standard single-star wavefront control (SSWC). We also discuss the main limiting factors that affect the MSWC performance in our experiments.

Binary stars↗

2D grating simulation for X-ray phase-contrast and dark-field imaging with a Talbot interferometer

Talbot interferometry is a recently developed and an extremely powerful X-ray phase-contrast imaging technique. Besides giving access to ultra-high sensitivity differential phase contrast images, it also provides the dark field image, which is a map of the scattering power of the sample. In this paper we investigate the potentialities of an improved version of the interferometer, in which two dimensional gratings are used instead of standard line grids. This approach allows to overcome the difficulties that might be encountered in the images produced by a one dimensional interferometer. Among these limitations there are the phase wrapping and quantitative phase retrieval problems and the directionality of the differential phase and dark-field signals. The feasibility of the 2D Talbot interferometer has been studied with a numerical simulation on the performances of its optical components under different circumstances. The gratings can be obtained either by an ad hoc fabrication of the 2D structures or by a superposition of two perpendicular linear grids. Through this simulation it has been possible to find the best parameters for a practical implementation of the 2D Talbot interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimating the performance of lithium beam measurements of current density and electron density in an H-mode pedestal

The lithium beam is an effective diagnostic tool for investigation of stability and particle transport in the pedestal. It was used successfully to measure edge current density on DIII-D, achieving qualitative agreement with neoclassical models. Electron density profiles were also measured. Proposed upgrades will continue these measurements with higher reliability as well as explore edge current measurements using spectroscopy. The optics will be redesigned to optimize throughput and aperture broadening and to replace the photomultiplier tubes with avalanche photodiodes. Here, the new system will yield detailed measurements of the pedestal, complementing existing diagnostics for investigating pedestal stability, edge localized mode cycle, and particle transport through the pedestal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗