Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An improved detailed chemical kinetic model for C3-C4 linear and iso-alcohols and their blends with gasoline at engine-relevant conditions

Propanol and butanol isomers have received significant research attention as promising fuel additives or neat biofuels. Robust chemical kinetic models are needed that can provide accurate and efficient predictions of combustion performance across a wide range of engine relevant conditions. Herein, this study seeks to improve the understanding of ignition and combustion behavior of pure C3-C4 linear and iso-alcohols, and their blends with gasoline at engine-relevant conditions. In this work, a kinetic model with improved thermochemistry and reaction kinetics was developed based on recent theoretical calculations of H-atom abstraction and peroxy radical reaction rates. Kinetic model validations are reported, and the current model reproduces the ignition delay times of the C3 and C4 alcohols well. Variations in reactivity over a wide range of temperatures and other operating conditions are also well predicted by the current model. Recent ignition delay time measurements from a rapid compression machine of neat iso-propanol and iso-butanol [Cheng et al., Proc. Combust Inst. (2020)] and blends with a research grade gasoline [Goldsborough et al., Proc. Combust Inst. (2020)] at elevated pressure (20–40 bar) and intermediate temperatures (780–950 K) were used to demonstrate the accuracy of the current kinetic model at conditions relevant to boosted spark-ignition engines. The effects of alcohol blending with gasoline on the autoignition behavior are discussed. The current model captures the suppression of reactivity in the low-temperature and negative-temperature-coefficient (NTC) region when either isopropanol and isobutanol are added to a research grade gasoline. Sensitivity and reaction flux analysis were performed to provide insights into the relevant fuel chemistry of the C3-C4 alcohols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Treatment of brackish water reverse osmosis brine using only solar energy

Post-treatment of brine produced by reverse osmosis (RO) is a great challenge as it often requires high energy input and works under extreme operating conditions. In this study, brine from a RO plant in El Paso, TX USA was successfully treated using a pilot-scale nanophotonics enhanced solar membrane distillation (NESMD) system. The novel NESMD reactor has a nanophotonic membrane surface area of 0.2 m 2 and an internal heat recovery system to recover the latent heat released during vapor condensation. By utilizing a sweeping gas operational mode under real solar irradiation (585–827 W m -2 ), the NESMD realized successful desalination of RO brine with the membrane flux reaching 0.45–0.65 kg m -2 h -1 and total dissolved solids (TDS) removal greater than 99.5% without an external heat condenser. The decrease in the feed flow rate to the evaporation channel of the NESMD system led to an increase in the gained output ratio (GOR) from 0.35 to 0.62. We report to the best of our knowledge, this is the largest photothermal reactor utilized for the desalination of real RO brine under practical solar irradiation. Compared with conventional brine treatment processes that require high temperature or pressure, the NESMD desalinates RO brine at near-ambient temperature and pressure with free solar energy, providing a promising approach for water desalination, and RO brine post treatment.

42 ENGINEERING↗

Laminar burning speed measurements for hydrogen enhanced natural gas in a spherical chamber

This work presents laminar burning speed measurements for natural gas and hydrogen enhanced natural gas in gas-turbine conditions using a spherical combustion chamber at an initial temperature and pressure of 296 K and 10 atm, respectively. Natural gas and hydrogen fuels were prepared and mixed with a synthetic air mixture comprised of oxygen, nitrogen, and helium. The experimental data collected during 10 atm ignition was used to predict the LBS at elevated pressures (30 bar) to approach gas-turbine operating conditions. A significant enhancing effect of combustion pressure on LBS was observed, as well as H2 dilution. This work provides fundamental combustion data relevant to sustainable fuels to reduce economic dependence on carbon-based fossil fuels and reduce anthropogenic climate effects through 2050.

Yovino, Louis↗

Advanced Coolant Enclosure Solutions for Micro Gas Cooled Reactors with Enhanced Efficiency and Safety

Argonne’s advanced high-pressure, high-temperature gas enclosures solutions were developed and tested for Light Water Reactor (LWR) fuel applications wherein pressure, temperature, fuel and working fluid are substantially different when compared to the operating conditions typical of gas cooled reactors (GCR). For LWR applications the coolant sleeve pressure exerted on the inner and outer walls of the sleeve may be equalized by pressurizing the fuel rod (e.g., with helium gas) to compensate for the coolant high pressure exerted on the outer walls of the sleeve. This results in a lower differential pressure. Micro-GCRs are reactor systems operated at elevated temperatures and pressure with gas as a working fluid. HolosGen’s Holos-Quad represent a type of Micro-GCR wherein the core is sleeved to segregate the fuel and other components from the working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Robust Distribution System Load Restoration With Time-Dependent Cold Load Pickup

Service restoration is one of the critical functions to enable the future self-healing distribution system. To restore the distribution system in a timely and reliable manner, the realistic system operating conditions need to be accurately characterized. Here, two main factors that have great impacts on distribution system restoration (DSR) in practice are investigated. First, cold load pickup (CLPU), generally caused by thermostatically controlled loads (TCLs), is a common phenomenon after an outage and shaped by the outage duration. However, the time-dependent behaviors of CLPU are rarely considered in literature. In this paper, the operating state evolution of TCLs after an outage is analyzed to characterize time-dependent CLPU. And the time-dependent CLPU is analytically embedded in DSR to accurately represent the actual behaviors of the restored loads. Second, it is difficult to predict loads that fluctuate during DSR due to the lack of real-time measurement data. Accordingly, a robust DSR based on the information gap decision theory (IGDT) is proposed to address this challenge, fully considering the uncertainty of CLPU. The proposed models are tested in IEEE 13-node and 123-node test feeders. Simulation results demonstrate that the time-dependent CLPU model and the uncertainty modeling of CLPU can accurately capture the actual behaviors of loads with TCLs after an outage, which greatly improves DSR decisions in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Experimental studies on the effects of sheet resistance and wettability of catalyst layer on electro-catalytic activities for oxygen evolution reaction in proton exchange membrane electrolysis cells

As the most important part of electrochemical reaction in proton exchange membrane electrolysis cells (PEMECs) for water splitting, oxygen evolution reaction (OER) occurs at the anode catalyst layer (CL). The distribution of the OER site is affected by many factors, such as properties of CL, operation parameters, procedures, etc. To study the effects of properties of CLs on the distribution of OER site on the CL, and consequently affect the performance of PEMECs, CLs with different sheet resistances are tested under different operation conditions. Furthermore, the phenomena of OER on CLs are captured by a high-speed and micro-scale visualization system in-situ and analysed coupled with electrochemical results. The results in this work show that both sheet resistance and wettability of CLs have significant impact on the distribution of the OER site, which can help optimize the design of membrane electrode assembly and improve the operating parameters for electrochemical devices.

08 HYDROGEN↗

Assessing Options for Particulate Measurement Tools to Advance Wood Heaters (CRADA Final Report)

For approximately 40 years, particulate matter (PM) from residential wood heaters has been certified in North America using an EPA dilution tunnel with a filter-based gravimetric measurement. While reasonably repeatable, this approach reports only a single value for the entire burn sequence and does not provide information on PM at different points within the sequence, which would support improved wood heater designs. PM monitors that report with high time resolution offer a potential solution, but their performance for various types of heaters and across heater operating conditions has not been extensively evaluated. In this 18-month collaborative project, the Hearth, Patio & Barbecue Association (HPBA) and Lawrence Berkeley National Laboratory (LBNL) tested five continuous PM instruments spanning three measurement principles—light-scattering, inertial mass (TEOM), and triboelectric—against gravimetric and size-resolved references on three residential heater types (cordwood, catalytic cordwood, and pellet) across startup, high-burn, and low-burn operating phases.

42 ENGINEERING↗

An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant

As a promising alternative to inefficient vapor-compression-based air conditioning, liquid desiccant dehumidification uses a liquid desiccant in contact with the humid air absorbing the moisture. However, it has not gained much market share due to the issues related to the carryover, corrosion, fouling, and crystallization of liquid desiccant. The research has developed a new membrane-based exchanger, which uses a non-corrosive ionic liquid desiccant and nonporous tubular membranes to address these issues. As the second generation of the prototype, the new exchanger was tested at various operating conditions. According to the experimental data, when it is used in the dehumidification loop, the new membrane-based exchanger achieves a specific vapor transportation rate of 778.6 g/(h–m 2 ) and an average water vapor flux of 0.316 g/(h-m 2 -Pa), which is a significant improvement compared with the previous designs using nonporous membranes. It also achieved a comparable or even better dehumidification performance compared with the dehumidifiers that use porous membrane and conventional liquid desiccants. However, the regeneration performance is not as good as its dehumidification. It is mainly caused by the high operating temperature required in the regeneration loop. The experimental data and findings provide first-hand experimental data and enhance the understanding of advanced membrane-based ionic liquid desiccant systems.

42 ENGINEERING↗

Four-Stage Multi-Physics Simulations to Assist Temperature Sensor Design for Industrial-Scale Coal-Fired Boiler

The growth of renewable energy sources presents a pressing challenge to the operation and maintenance of existing fossil fuel power plants, given that fossil fuel remains the predominant fuel source, responsible for over 60% of electricity generation in the United States. One of the main concerns within these fossil fuel power plants is the unpredictable failure of boiler tubes, resulting in emergency maintenance with significant economic and societal consequences. A reliable high-temperature sensor is necessary for in situ monitoring of boiler tubes and the safety of fossil fuel power plants. In this study, a comprehensive four-stage multi-physics computational framework is developed to assist the design, optimization installation, and operation of the high-temperature stainless-steel and quartz coaxial cable sensor (SSQ-CCS) for coal-fired boiler applications. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. With the simulation-guided sensor installation plan, the newly designed SSQ-CCSs have been employed for field testing for more than 430 days. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

42 ENGINEERING↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DOE CESER 6 GHz Interference Study

DOE CESER has sponsored Idaho National Laboratory (INL) to conduct an objective and independent study of potential 6 GHz interference from outdoor operation of unlicensed devices in the 6 GHz band on fixed service (FS) microwave communication links operated by electrical sector incumbents in that band. INL is collaborating with University of Notre Dame (UND), Electric Power Research Institute (EPRI), Lockard & White, Southern Company, and AT&T, to gather data with real-world 6 GHz interference experiments and identify (1) the potential for interference from unlicensed devices and (2) the interference necessary to cause harm to the incumbents. In addition to the functional assessment, a security assessment of the FCC mandated Automatic Frequency Coordination (AFC) System to regulate use of unlicensed 6 GHz standard power devices is also being conducted. A major objective is to create a science-based and defensible methodology used to produce the necessary data and to derive objective conclusions. This proven methodology can then be used to produce objective data and conclusions for other spectrum bands with similar incumbent uses including 4.4 – 4.9 GHz and 7.125 – 7.4 GHz, identified in the reconciliation bill that was adopted on July 4, 2025, as well as the National Spectrum Strategy discussions that are ongoing. This report contains 6 GHz field experiments and findings in the following real-world scenarios with commercial unlicensed standard power (SP) 6 GHz devices regulated by Automated Frequency Coordination (AFC): • University of Notre Dame (UND) Stadium with a capacity of 80,000 spectators, where Wi-Fi operating in 6 GHz has been deployed recently • Southern Company 6 GHz FS microwave link between Columbus and Fortson, Georgia Following are the following key findings from this study. 1. The AFC is under-protective of FS when line-of-sight exists along the path centerline. Data collected at Southern’s 6 GHz fixed link site shows significant erosion of as much as 21.4-24.4 dB of under-protection that can lead to potential service degradation under typical operating conditions. This first key finding is most likely the result of erroneous use of the RF propagation model. INL will collaborate with EPRI and the AFC Functional Requirements Working Group to submit a change request to the WinnForum TS-1014 standard towards correct use of the propagation model by the AFC. 2. There is additive interference effect of about 3 dB from nearly equal power interferers measured from simultaneous operation of two SP AP's operating co-channel with the FS receive from different locations along the path. This second key finding should be used to add the impact of additive interference of operation of multiple APs in the same geographical area, to the next generation of AFCs. INL will collaborate with FCC on the need for the AFC to consider additive interference. We also recommend that additional experiments are conducted on 6 GHz spectrum interference to further improve the AFC operation as the number of outdoor Wi-Fi devices continues to increase. These proposed steps and recommendations will make the co-existence of the incumbents and the 6 GHz outdoor Wi-Fi providers possible without any impact on the incumbents with a win-win outcome for all.

6 GHz↗

The performance evaluation of direct detection electron energy-loss spectroscopy at 200 kV and 80 kV accelerating voltages

Direct electron detectors (DeDs) have been widely used for imaging studies because of their higher beam sensitivity, lower noise, improved pixel resolution, etc. However, there have been limited studies related to the performance in spectroscopic applications for the direct electron detection. Hereby, taking the advantage of the DeD installed on a high-performance electron energy-loss spectrometer, we systematically studied the performance of a DeD (Gatan's K2 IS) fitted on an aberration-corrected transmission electron microscope (TEM) equipped with an electron monochromator. Using SrTiO3 as the model system, the point spread function in the zero-loss region of the spectrum and the performance for core loss spectroscopy have been investigated under both 200 kV and 80 kV operating conditions. We demonstrate that the K2 detector can achieve an overall better performance at 200 kV than a charge coupled device (CCD) detector. At 80 kV, the K2 DeD is still better than a CCD, except for the relative broad tails of the zero-loss peak. The signal-to-noise ratio is very close for DeD and CCD under 80 kV. Based on our data obtained at different operating voltages, it is clear that DeD will benefit the microscopy community and boost the development of cutting-edge materials science studies by pushing the frontiers in electron energy-loss spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Model Development for Multi-Component Fuel Vaporization and Flash Boiling

The objectives of this project are to improve the multi-component fuel droplet and film vaporization models used in internal combustion engine simulation, and to develop a comprehensive model to predict the characteristics of multi-component flash boiling spray. This work explores two approaches to fuel composition treatment for modeling multi-component fuel vaporization: one based on discretization and surrogates, and the other based on continuous thermodynamic distribution of fuel properties. The experimental data collected for model validation are done under three fuel form factors: droplet, spray, and thin film. The study on sprays also include experimentation under non-flash and flash boiling conditions, a phenomenon that enhances fuel vaporization. The main goals of this work are: Design and develop a multi-component fuel droplet and wall film vaporization model using both discrete and continuous thermodynamics methods. Design and develop an analytical model for multi-component flash boiling. Integrate the multi-component droplet and film model into multi-dimensional engine calculations to predict the fuel vaporization process under engine operation condition. Conduct multi-component droplet and fuel film vaporization experiments in a non-combusting chamber to verify the proposed vaporization models. Characterize flash boiling phenomena of multi-component fuel sprays by optical and laser diagnostic techniques. This report will detail the experimental setup and the numerical basis for developing a model to achieve the main goals listed above. Key features of observed multi-component fuel vaporization will be summarized at the end of each experimental sections, and corresponding model performance evaluation will be presented at the end of each model development section.

33 ADVANCED PROPULSION SYSTEMS↗

Machine Protection Studies of Fast Instability-Driven Beam Losses in the EIC Electron Storage Ring

Fast transverse beam instabilities represent one of the most challenging protection scenarios for the Electron-Ion Collider (EIC) electron storage ring (ESR). Coherent betatron oscillations driven by collective effects can grow rapidly and lead to substantial beam losses within only a few tens of turns, posing a threat to collimators, superconducting (SC) magnets, cryogenic systems, and detector components. A dedicated simulation framework based on distributed transverse excitations was developed to evaluate instability-driven beam losses in the ESR. A conservative instability rise time on the order of 10 turns was used to define a bounding protection scenario. Simulations show that the original two-collimator configuration is insufficient to localize losses under all operating conditions, whereas an optimized four-collimator configuration reduces loss leakage into protected regions by more than two orders of magnitude. Nevertheless, the most severe instability scenarios produce catastrophic beam impacts, with nearly half of the stored beam being intercepted by the collimators within a single turn, exceeding the preliminary estimated survivability limits of the baseline collimator design. The results demonstrate that collimation alone is insufficient to guarantee safe ESR operation and must be complemented by a fast machine-protection system. Dedicated turn-by-turn beam-position monitors and fast beam-loss monitors provide sufficient advance warning to detect instability growth and initiate a beam abort before equipment-damaging loss levels are reached. These findings establish quantitative requirements for the ESR machine-protection architecture and support the implementation of a multilayer protection strategy for both accelerator and detector systems.

43 PARTICLE ACCELERATORS↗